Pharmaceutical sponsor
Cochlear Clinical Trials
Studies where Cochlear is the lead sponsor: its pipeline by phase, what is enrolling now and where. Studies it supports as a collaborator are in the search.
In numbers
Open to volunteers: recruiting, not yet recruiting or enrolling by invitation. Active adds studies under way that have stopped recruiting.
Open to volunteers
All 9Sensorineural Hearing Loss, Tinnitus
Effect of a Totally Implantable Cochlear Implant on Tinnitus Severity in Adults With Preoperative Tinnitus
The purpose of this study is to investigate the degree of benefit to tinnitus symptoms by using a Totally Implantable cochlear implant (TICI) in a group of patients who have moderate-to-severe tinnitus pre-operatively.
- Trial name
- EXCITE (NCT07893860)
- Testing
- Cochlear implant
- Where
- Spain
- Volunteers
- 14 people
- Sponsor
- Cochlear
Hearing Loss, Hearing Implants
A Study to Evaluate Clinical Benefit, Performance and Safety of Cochlear Implants in Adults
The aim of this clinical investigation is to demonstrate the performance, clinical benefit and safety of commercial cochlear implant systems.
- Trial name
- ORBIT-MU (NCT07338864)
- Testing
- Cochlear Nucleus Nexa Cochlear implant (CI1032), Cochlear Nucleus Nexa Cochlear implant (CI1022), Cochlear Nucleus Nexa Cochlear implant (CI1012)
- Where
- Germany
- Volunteers
- 66 people
- Sponsor
- Cochlear
Bone Conduction, Hearing Loss, Conductive
Post-market Evaluation of the Transition From the Baha Connect System to the Osia System in Adult Bone Conduction Implant Recipients
The goal of this interventional study is to confirm the safety and performance of the latest generation Osia System and to examine its benefits compared to the Baha Connect System in adults with mixed or conductive hearing loss…
- Conditions
- Bone Conduction, Hearing Loss, Conductive, Hearing Loss, Mixed
- Trial name
- OSIRIS (NCT07130136)
- Testing
- Cochlear™ Osia® System, Cochlear™ Baha® System
- Where
- 3 sites in United Kingdom
- Volunteers
- 20 people
- Sponsor
- Cochlear
Cochlear Implant Users
Investigating the Acceptance and Performance of Low Energy Audio Streaming in Nucleus 8 and Kanso 3 Sound Processors by Experienced Cochlear Implant Users
This study aims to investigate acceptance and performance of the Bluetooth Low Energy Audio-enabled (LE Audio) firmware in the Nucleus 8 Processing Unit, Kanso 3 Nexa Sound Processor, and the Kanso 3 Sound Processor.
- Trial name
- STREAM (NCT07262827)
- Testing
- Nucleus 8 Sound Processor streaming via MultiMic+, Nucleus 8 Sound Processor microphones, Nucleus 8 Sound Processor streaming via Roger 20
- Where
- Australia
- Volunteers
- 20 people
- Sponsor
- Cochlear
Hearing Loss
New Algorithms to Signal Processing for Speech Enhancement in Adult Cochlear Implant Recipients.
The purpose of this clinical investigation is to develop pre-processing strategies to enhance speech and reduce noise for CI listeners.
- Trial name
- PRESENCE-MU (NCT06100393)
- Testing
- Investigational Pre-Processing Algorithm (Sub A), Cochlear Limited standard-of-care pre-processing algorithms, Investigational Pre-Processing Algorithm (Sub B)
- Where
- 2 sites in Australia
- Volunteers
- 150 people
- Sponsor
- Cochlear
Hearing Impairment
A Study Examining Acceptability of Auditory Implant Fitting Software Technologies
Auditory implant fitting software is used by hearing healthcare professionals to adjust and optimize hearing implant systems for people with hearing loss.
- Trial name
- SUNRISE-MU (NCT07763873)
- Testing
- Investigational Software
- Where
- 2 sites in United States, Australia
- Volunteers
- 200 people
- Sponsor
- Cochlear
Vestibulopathy, Moderate to Severe Hearing Loss
A Study to Evaluate the Safety and Performance of a Vestibular Implant in Adults to Provide Balance Restoration
The main aim of this study is to understand if an experimental vestibular implant system can improve balance performance. The system consists of a vestibular implant combined with a cochlear implant sound processor and…
- Conditions
- Vestibulopathy, Moderate to Severe Hearing Loss, Normal Hearing, Balance Deficits
- Trial name
- BionicVEST2 (NCT06805175)
- Testing
- vestibular implant
- Where
- 3 sites in Belgium, Spain
- Volunteers
- 18 people
- Sponsor
- Cochlear
Sensorineural Hearing Loss, Bilateral Hearing Loss
Long-term Follow-up of a Cochlear Implant With Dexamethasone Eluting Electrode Array
A long-term follow-up of Cochlear's cochlear implant electrode array which passively elutes dexamethasone for a defined period of time to help reduce inflammatory responses.
- Trial name
- CI-DEX-LTFU (NCT06936449)
- Testing
- CI632D, CI632
- Where
- 3 sites in United States
- Volunteers
- 19 people
- Sponsor
- Cochlear
Tinnitus, Hearing Loss, Bilateral or Unilateral
Evaluating How a Tinnitus Implant Affects Tinnitus Loudness in Adults With Chronic Tinnitus and Varying Levels of Hearing Loss
This study will test an experimental Tinnitus Implant System that consists of a cochlear implant, sound processor and programming software.
- Conditions
- Tinnitus, Hearing Loss, Bilateral or Unilateral, Normal Hearing
- Trial name
- TINIS (NCT06641999)
- Testing
- Tinnitus Implant System
- Where
- 2 sites in Belgium, Netherlands
- Volunteers
- 16 people
- Sponsor
- Cochlear
Completed, with results posted
All 54Hearing Loss
Nucleus Hybrid L24 Extended Duration Post Approval Study
This post approval study evaluates the long term safety and efficacy of the Nucleus Hybrid L24 Implant System in a group of already implanted recipients.
- Trial name
- HED (NCT02379273)
- Testing
- Nucleus Hybrid L24 Implant
- Volunteers
- 35 people
- Sponsor
- Cochlear
Sensorineural Hearing Loss, Low-Frequency Residual Hearing
Perimodiolar Implant Performance in Adults With Low-Frequency Residual Hearing
The purpose of the feasibility study is to investigate hearing performance (audiometry and speech perception) using the CI632 in a group of adults (n=15) with low-frequency residual hearing who meet inclusion criteria.
- Trial name
- NCT04741009
- Testing
- CI632 Slim Modiolar Electrode
- Where
- 4 sites in United States
- Volunteers
- 10 people
- Sponsor
- Cochlear
Hearing Impairment, Sensorineural
A Feasibility Study Evaluating the Performance of Focused Multipolar Stimulation and Sound Coding in Adults.
The purpose of this early feasibility study is to explore several facets of hearing performance of Focused Multipolar stimulation in adult cochlear implant users.
- Trial name
- SASC (NCT05641155)
- Testing
- Focused Multipolar Stimulation (FMS) strategy
- Where
- 5 sites in United States, Belgium
- Volunteers
- 18 people
- Sponsor
- Cochlear
Hearing Loss
Comparing the Performance of a Categorical Loudness Scaling Based Fitting With a Behavioural Fitting in Adults With a Nucleus Cochlear Implant 3 Months Post-activation
This study aims to collect data in newly implanted cochlear implant-recipients to inform future development of fitting methods to optimally and efficiently program a cochlear implant.
- Trial name
- CALOS4 (NCT05709223)
- Testing
- Categorical loudness scaling based fitting using the research fitting system., Behavioural fitting using Custom Sound Suite (CSS 6.3) Software
- Where
- 4 sites in United States, Australia and 1 more
- Volunteers
- 17 people
- Sponsor
- Cochlear
Hearing Loss, Sensorineural
Investigating Stimulation Parameter and Electrode Mode Changes on Speech Perception in Experienced Adult Cochlear Implant Recipients
This study aims to investigate the effect of stimulation parameters and different electrode modes on speech perception in adult cochlear implant recipients.
- Trial name
- DUAL (NCT06298396)
- Testing
- Program using default MAP, Program using low-power 1 (LP1) MAP, Program using low-power 2 (LP2) MAP
- Where
- Australia
- Volunteers
- 20 people
- Sponsor
- Cochlear