A Roentgen Stereophotogrammetric Analysis on Migration of Knee Prostheses.

A study testing Tibial component in people with Osteoarthritis, run by University of Aarhus at 1 site in Denmark.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to compare the early migration of two uncemented total knee arthroplasties with different metal coating. Only the tibial prosthesis plateau varies. One is made out of tantalum and has two short pegs for fixation into the tibia while the other is covered by titanium fiber-mesh on the… Read more about this study

Who is it for?
Ages 18 to 70 years
Conditions the study is for
Osteoarthritis
What is being tested?
Tibial component
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
50 participants
Where
1 siteDenmark
Study dates
Nov 2003to Apr 2010
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 70 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients with one- or double-sided primary knee arthrosis.
  • Patients with a sufficient bone quality for implantation of an uncemented prosthesis.
  • Informed and written patient consent.

Who cannot join

  • Patients with neuromuscular or vascular diseases in the affected leg.
  • Patients who peroperatively are estimated unsuitable for an uncemented knee arthroplasty e.g. due to bone cysts or dilution of the bone mass.
  • Patients who use non-steroid anti-inflammatory drugs (NSAID) and cannot refrain from taking them postoperatively (this includes COX-2-inhibitors).
  • Patients with osteoporosis estimated from the preoperative x-ray or former diagnosis of osteoporosis.
  • Patients with fracture sequelae.
  • Women, who are pregnant or are at risk of getting pregnant.

Trial locations and contacts

1 site in 1 country.

Denmark1 site
  • Orthopaedic Center, Aarhus University Hospital.

    Aarhus, 8200

Other trials in Denmark

About this study

Official title: A Roentgen Stereophotogrammetric Analysis on Migration of Knee Prostheses. A Randomised Prospective Study of Tantalum Versus Titanium Implants.

The purpose of this study is to compare the early migration of two uncemented total knee arthroplasties with different metal coating. Only the tibial prosthesis plateau varies. One is made out of tantalum and has two short pegs for fixation into the tibia while the other is covered by titanium fiber-mesh on the bone-near site and has 4 short pegs for screw fixation into the tibia.

Read the detailed description

Around 4% of total knee arthroplasties (TKA) are revised 15 years after the primary operation, most due to loosening of the implant. The use of uncemented prostheses are expected to extend the fixation time and thereby the years of TKA survival. When a cementless implant is inserted, direct bone ingrowth to the implant depends on a complete primary stabilisation. Movement between the bone and implant will cause a fibrous membrane leading to micromotions. Micromotions can be evaluated by radiophotogrammetric analysis (RSA) in early follow-up and they have been shown to be a prognostic marker for painful loosening of the implant.

Tantalum is a fairly new biomaterial designed with a high and bone-binding porosity. Tantalum has already proven to be a good prosthesis material facilitating fast bone-ingrowth and supplying mechanical qualities in the bone-prosthesis interface that surpasses the qualities of regular prosthesis materials by uncemented method. Titanium on the other hand has been used as a prosthesis coating for years and also promote prosthesis fixation by osteointegration.

The purpose of this study is to compare the early migration of two uncemented total knee implants with different metal coating and fixation method. Only the tibial prosthesis plateau varies in design. One plateau is a 2 pegged tantalum monobloc and the other plateau is a modular titanium fiber-mesh coating with 4 short pegs for screw fixation into the tibia.

Furthermore the extend of the expected micromovements between the polyethylene liner and the metal backing of the titanium plateau will be compared to the stable tantalum monobloc.

Theoretically tantalum should allow a more optimal coating for bone ingrowth, but as primary stability is also important for longterm prostheses survival the method of primary fixation could alså play a role.

To evaluate both the plateau-bone micromotions and the polyethylene-prosthesis micromovements metal markers have been placed on the prosthesis pre-operatively and furthermore into the tibial bone and into the tibial polyethylene during surgery allowing us to evaluate stereo x-rays by a photogrammetric analyses called RSA at the Orthopaedic Center, Aarhus University Hospital. Follow-up stereo x-rays will be scheduled for 1 week, 3 months, 6 month, 1 years, 2 years and 5 years post-surgery.

Conditions
Osteoarthritis
Being tested
Tibial component
Keywords
RSA, Genoarthrosis, Knee arthroplasty, Micromotion of polyethylene liner
Medical subject headings
Osteoarthritis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Tibial componentDevice

    Also called NexGen Tantalum Tibial Plate, NexGen Titanium Tibial Plate, screw fixed

    Tibial component inserted at the time of surgery

Study groups in NCT00138853
Study groupRoleWhat they receive
Tantalum kneeActive comparatorTantalum Tibial component, uncemented
Receives: Device: Tibial component
Titanium KneeActive comparatorTitanium Tibial Component, screw fixed
Receives: Device: Tibial component

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Polyethylene wear (mm) of the medial and lateral knee prosthesis compartments at 5 years followup measured with model-based radiostereometry

    Measured: Up to 5 years

Secondary outcomes (3)
  1. Difference in MPTM (mm) tibial component migration from 2-5 years (stabilization 3) measured with model-based radiostereometry

    Measured: up to 5 years

  2. Number of implants migrating above 0.2mm MTPM from 1-2 years (stabilization 2) and 2-5 years (stabilization 3) measured with model-based radiostereometry

    Measured: Up to 5 years

  3. Osteolysis (radiolucent lines >1 mm) in the tibial periprosthetic region measured on radiographs

    Measured: Up to 5 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted30 Aug 2005 (estimated)
  2. Study startNov 2003
  3. Primary completionApr 2010
  4. Study completionApr 2010

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
50 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00138853
Sponsor's protocol ID
20030119
Acronym
Ti-Tan
Status last verified
Feb 2020
First submitted
29 Aug 2005
Last updated
19 Dec 2022
Results posted
No
Data monitoring committee
Yes

Questions about this trial

What is this clinical trial studying?

A study testing Tibial component in people with Osteoarthritis, run by University of Aarhus at 1 site in Denmark.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Dec 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Denmark. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Polyethylene wear (mm) of the medial and lateral knee prosthesis compartments at 5 years followup measured with model-based radiostereometry (time frame: Up to 5 years). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Dec 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in