AzTrials
AzTrials

StentsPhase 3NCT00180479

SPIRIT III Clinical Trial of the XIENCE V® Everolimus Eluting Coronary Stent System (EECSS)

A Phase 3 study testing XIENCE V® Everolimus Eluting Coronary Stent and TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent in people with Stents and Coronary Artery Disease, run by Abbott Medical Devices at 65 sites in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study is divided into 5 arms: 1. Randomized Clinical Trial (RCT): Prospective, randomized, active-controlled, single blind, parallel two-arm multi-center clinical trial in the United States (US) comparing XIENCE V® Everolimus Eluting Coronary Stent System (CSS) (2.5, 3.0, 3.5 mm diameter stents) to the Food and… Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
XIENCE V® Everolimus Eluting Coronary Stent and TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
1,002 participants
Where
65 sitesUnited States
Study dates
Jun 2005to Nov 2011
Phase
Phase 3
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Target lesion(s) must be located in a native epicardial vessel with visually estimated diameter between >= 2.25 mm and <= 4.25 mm and a lesion length <= 32 mm
  • The target lesion(s) must be in a major artery or branch with a visually estimated stenosis of >= 50% and < 100% with a thrombolysis in myocardial infarction (TIMI) flow of >= 1
  • Non-study, percutaneous intervention for lesions in a non-target vessel is allowed if done >= 90 days prior to the index procedure (subjects who received brachytherapy will be excluded from the trial)

Who cannot join

  • Located within an arterial or saphenous vein graft or distal to a diseased (vessel irregularity per angiogram and > 20% stenosed lesion by visual estimation) arterial or saphenous vein graft
  • Lesion involving a bifurcation >= 2 mm in diameter or ostial lesion > 50% stenosed by visual estimation or side branch requiring predilatation
  • Located in a major epicardial vessel that has been previously treated with brachytherapy
  • Located in a major epicardial vessel that has been previously treated with percutaneous intervention < 9 months prior to index procedure
  • Total occlusion (TIMI flow 0), prior to wire passing
  • The target vessel contains thrombus
  • Another significant lesion (> 40% diameter stenosis [DS]) is located in the same epicardial vessel as the target lesion

Trial locations and contacts

65 sites in 1 country.

65 sites in 1 country

United States65 sites
  • Presbyterian Hospital

    Albuquerque, New Mexico, 28204

  • Emory Crawford Long Hospital

    Atlanta, Georgia, 30308

  • Piedmont Hospital

    Atlanta, Georgia, 30309

  • Saint Joseph's Hospital of Atlanta

    Atlanta, Georgia, 30342

  • Heart Hospital of Austin

    Austin, Texas, 78756

  • Johns Hopkins Hospital

    Baltimore, Maryland, 21287

  • Baptist Medical Center Princeton

    Birmingham, Alabama, 35211

  • Baptist Health System - Montclair

    Birmingham, Alabama, 35213

  • Brigham & Women's Hospital

    Boston, Massachusetts, 02115

  • Beth Israel Deaconess Medical Center

    Boston, Massachusetts, 02215

  • Fletcher Allen Health Care

    Burlington, Vermont, 05401

  • Medical University of South Carolina

    Charleston, South Carolina, 29403

  • Presbyterian Hospital

    Charlotte, North Carolina, 87106

  • Rush University Medical Center

    Chicago, Illinois, 60612

  • The Christ Hospital

    Cincinnati, Ohio, 45219

  • Riverside Methodist Hospital

    Columbus, Ohio, 43214

  • Medical City Dallas Hospital

    Dallas, Texas, 75230

  • St John Hospital & Medical Center

    Detroit, Michigan, 48236

  • Duke University Medical Center

    Durham, North Carolina, 27710

  • Elmhurst Memorial Hospital

    Elmhurst, Illinois, 60148

  • EMH Regional Medical Center

    Elyria, Ohio, 44035

  • Sacred Heart Medical Center

    Eugene, Oregon, 97401

  • Poudre Valley Hospital

    Fort Collins, Colorado, 80528

  • Holy Cross Medical Center (prev. North Ridge MC)

    Fort Lauderdale, Florida, 33308

  • Spectrum Health Hospital

    Grand Rapids, Michigan, 49503

  • Hackensack Medical Center

    Hackensack, New Jersey, 07601

  • Pinnacle Health @ Harrisburg Hospital

    Harrisburg, Pennsylvania, 17043

  • Methodist Hospital

    Houston, Texas, 77030

  • The Heart Center of IN, LLC

    Indianapolis, Indiana, 46290

  • Borgess Medical Center

    Kalamazoo, Michigan, 49048

  • St. Luke's Hospital

    Kansas City, Missouri, 64111

  • Scripps Memorial Hospital

    La Jolla, California, 92037

  • Dartmouth-Hitchcock Medical Center

    Lebanon, New Hampshire, 03756

  • Nebraska Heart Hospital

    Lincoln, Nebraska, 68526

  • Good Samaritan Hospital

    Los Angeles, California, 87106

  • Jewish Hospital

    Louisville, Kentucky, 40202

  • Baptist Hospital of Miami

    Miami, Florida, 33176

  • St. Luke's Medical Center

    Milwaukee, Wisconsin, 53215

  • Abbott Northwestern Hospital

    Minneapolis, Minnesota, 55407

  • St. Patrick Hospital

    Missoula, Montana, 59802

  • Long Island Jewish Medical Center

    New Hyde Park, New York, 11040

  • Ochsner Clinic Foundation

    New Orleans, Louisiana, 70121

  • Columbia University Medical Center

    New York, New York, 10032

  • Alta Bates Summit Medical Center

    Oakland, California, 94609

  • The University of Oklahoma Health Sciences Center

    Oklahoma City, Oklahoma, 73104

  • Integris Baptist Medical, Inc.

    Oklahoma City, Oklahoma, 73112

  • Northern Michigan Hospital

    Petoskey, Michigan, 49770

  • Arizona Heart Hospital

    Phoenix, Arizona, 85016

  • Allegheny General Hospital

    Pittsburgh, Pennsylvania, 15212

  • Providence St. Vincent Medical Center

    Portland, Oregon, 97225

  • Rhode Island Hospital

    Providence, Rhode Island, 02903

  • The Miriam Hospital

    Providence, Rhode Island, 02906

  • Wake Medical Center

    Raleigh, North Carolina, 27610

  • The Valley Hospital

    Ridgewood, New Jersey, 07450

  • Mercy General Hospital

    Sacramento, California, 95819

  • TexSan Heart Hospital

    San Antonio, Texas, 78215

  • Swedish Medical Center

    Seattle, Washington, 98104

  • St. John's Hospital

    Springfield, Illinois, 62701

  • Barnes Jewish Hospital

    St Louis, Missouri, 63110

  • St. Joseph's Hospital Health Center

    Syracuse, New York, 13203

  • Washington Adventist Hospital

    Takoma Park, Maryland, 20912

  • St. Joseph Medical Center

    Towson, Maryland, 21204

  • North Mississippi Medical Center

    Tupelo, Mississippi, 38801

  • Washington Hospital Center

    Washington D.C., District of Columbia, 20010

  • Wake Forest University Baptist Medical Center

    Winston-Salem, North Carolina, 27157

Other trials in United States

About this study

Official title: SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V® Everolimus Eluting Coronary Stent System (EECSS) in the Treatment of Subjects With de Novo Native Coronary Artery Lesions

This study is divided into 5 arms:

  1. Randomized Clinical Trial (RCT): Prospective, randomized, active-controlled, single blind, parallel two-arm multi-center clinical trial in the United States (US) comparing XIENCE V® Everolimus Eluting Coronary Stent System (CSS) (2.5, 3.0, 3.5 mm diameter stents) to the Food and Drug Administration (FDA) approved commercially available active control TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent (TAXUS® EXPRESS2™ PECS) System
  2. US 2.25 mm non-randomized arm using 2.25 mm diameter XIENCE V® Everolimus Eluting CSS
  3. US 4.0 mm non-randomized arm using 4.0 mm diameter XIENCE V® Everolimus Eluting CSS
  4. US 38 mm non-randomized arm using 38 mm in length XIENCE V® Everolimus Eluting CSS
  5. Japanese non-randomized arm using XIENCE V® Everolimus Eluting CSS (2.5, 3.0, 3.5, 4.0 mm diameter stents) in Japan

The TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent System is Manufactured by Boston Scientific.

Read the detailed description

The purpose of the SPIRIT III clinical trial is to evaluate the safety and efficacy of the XIENCE V® Everolimus Eluting Coronary Stent System (XIENCE V® EECSS). The XIENCE V® EECS (XIENCE V® arm) will be compared to an active control group represented by the FDA approved commercially available Boston Scientific TAXUS® EXPRESS2™ Paclitaxel-Eluting Coronary Stent (TAXUS® EXPRESS2™ PECS) System (TAXUS® arm).

The SPIRIT III clinical trial consists of a randomized clinical trial (RCT) in the US which will enroll approximately 1,002 subjects (2:1 randomization XIENCE V® EECS : TAXUS® EXPRESS2™ PECS) with a maximum of two de novo native coronary artery lesion treatment within vessel sizes >= 2.5 mm and <= 3.75 mm.

The SPIRIT III clinical trial also consists of three concurrent US non-randomized arms (2.25 mm diameter stent, 4.0 mm diameter stent and 38 mm length stent arms) and one Japanese non-randomized arm as follows:

  1. 105 subjects with a maximum of two de novo native coronary artery lesion within vessel sizes > 2.25 mm and < 2.5 mm and lesion length <= 22 mm will be enrolled concurrently in the US 2.25 mm non-randomized treatment arm
  2. 80 subjects with a maximum of two de novo native coronary artery lesion within vessel sizes > 3.75 mm and >= 4.25 mm and lesion length <= 28 mm will be enrolled concurrently in the US 4.0 mm non-randomized treatment arm
  3. 105 subjects with a maximum of two de novo native coronary artery lesion within vessel sizes > 3.0 mm and < 4.25 mm and lesion length > 24 mm and < 32 mm will be enrolled concurrently in the US 38 mm non-randomized treatment arm.
  4. 88 Japanese subjects with a maximum of two de novo native coronary artery lesions within vessel sizes >= 2.5 mm and <= 4.25 mm and lesion length <= 28 mm will be enrolled concurrently in the non-randomized Japanese arm.

All subjects in the RCT and the four non-randomized arms will be screened per the protocol required inclusion/exclusion criteria. The data collected will be compared to data from the subjects enrolled into the TAXUS® arm of US RCT.

Subjects enrolled in the US RCT will be sub-grouped based on whether they will have an angiographic and/or an intravascular ultrasound (IVUS) follow-up at 240 days as follows:

Group A: Angiographic and IVUS follow-up at 240 days (N=240) Group B: Angiographic follow-up at 240 days (N=324) Group C: No angiographic or IVUS follow-up (N=438)

All subjects will have clinical follow-up at 30, 180, 240 and 270 days (Data collected through 270 days will be submitted as the primary data set for US and Japanese market approval), and 1, 2, 3, 4, and 5 years (for annual reports).

All subjects enrolled into three US non-randomized arms (N=105 for 2.25 mm arm, N=80 for 4.0 mm arm and N=105 for 38 mm stent arm) will have clinical follow-up at 30, 180, 240, and 270 days, and angiographic follow-up at 240 days. No IVUS follow-up is required for subjects enrolled in these arms.

All subjects enrolled into the Japanese non-randomized arm (N=88) will have clinical follow-up at 30, 180, 240, and 270 days, and angiographic and IVUS follow-up at 240 days.

All subjects who receive a bailout stent will be assigned to Group A follow-up subgroup (angiographic and IVUS follow-up at 240 days after the index procedure), regardless of their primary assignment at randomization. At sites without IVUS capability, subjects receiving bailout stent will be assigned to Group B follow-up subgroup (angiographic follow-up at 240 days after the index procedure). Angiographic follow-up is required for all bailout subjects at 240 days.

Data from the US RCT will be submitted to the FDA as the primary data set for product approval for RVD >= 2.5 mm and <= 3.75 mm (2.5 mm, 3.0 mm and 3.5 mm stents). Combined data of the US trial/Japanese non-randomized arm will be submitted to the Japanese Ministry of Health, Labor and Welfare (MHLW) for Japanese approval for RVD>=2.5 mm and <= 4.25 mm (2.5 mm, 3.0 mm 3.5 mm and 4.0 mm stents). Data from the Japanese non-randomized arm will be submitted to the FDA as additional safety data. Data from the US non-randomized arms of the trial will be the primary data sets for approval for 2.25 mm diameter stent (RVD > 2.25 mm and < 2.5 mm), 4.0 mm diameter stent (RVD > 3.75 mm and <= 4.25 mm) and 38 mm length stent (RVD > 3.0 mm and <= 4.25 mm and lesion length > 24 mm and <= 32 mm), respectively in the US.

A pharmacokinetic substudy will be carried out in a minimum of 5 pre-determined sites in the US and a minimum of 5 pre-determined sites in Japan. In the US, the pharmacokinetics (PK) of everolimus, as delivered by the XIENCE V® EECS will be analyzed in a subset of 15 subjects (minimum) with single vessel/lesion treatment, and up to 20 subjects with dual vessel/lesion treatment, respectively. In Japan, a minimum of 10 subjects with single vessel/lesion treatment and up to 20 subjects with dual vessel/lesion treatment will have a PK measurements performed. These subsets will include subjects receiving overlapping stents.

Being tested
XIENCE V® Everolimus Eluting Coronary Stent, TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent
Keywords
Everolimus
Medical subject headings
Coronary Artery Disease, Coronary Restenosis, Vascular Diseases, Myocardial Ischemia, Coronary Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • XIENCE V® Everolimus Eluting Coronary StentDevice

    Also called XIENCE V® Everolimus Eluting Coronary Stent System

    Drug eluting stent implantation stent in the treatment of coronary artery disease.

  • TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary StentDevice

    Also called TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent System

    Drug eluting stent implantation stent in the treatment of coronary artery disease.

Study groups in NCT00180479
Study groupRoleWhat they receive
1ExperimentalXIENCE V® Everolimus Eluting Coronary Stent System
Receives: Device: XIENCE V® Everolimus Eluting Coronary Stent
2Active comparatorTAXUS® EXPRESS2™Paclitaxel Eluting Coronary Stent System
Receives: Device: TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Primary Endpoint: In-segment Late Loss (LL)

    In-segment minimal lumen diameter (MLD) post-procedure minus (-) in segment MLD at 240 day follow-up and 5 mm proximal and 5mm distal to the stent equals Late Loss. MLD defined: The average of two orthogonal views (when possible) of the narrowest point within the area of assessment.

    Measured: 240 days

Secondary outcomes (43)
  1. Major Secondary Endpoint: Ischemia Driven Target Vessel Failure (ID-TVF)

    The composite endpoint comprised of:

    • Cardiac death (death in which a cardiac cause cannot be excluded)
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI
    • Ischemia-driven target vessel revascularization (TVR) by CABG or PCI

    Measured: 270 days

  2. Target Vessel Failure (TVF)

    The composite endpoint comprised of:

    • Cardiac death (death in which a cardiac cause cannot be excluded)
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI
    • Ischemia-driven target vessel revascularization (TVR) by CABG or PCI

    Measured: 30 days

  3. Target Vessel Failure (TVF)

    The composite endpoint comprised of:

    • Cardiac death (death in which a cardiac cause cannot be excluded)
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI
    • Ischemia-driven target vessel revascularization (TVR) by CABG or PCI

    Measured: 180 days

  4. Target Vessel Failure (TVF)

    The composite endpoint comprised of:

    • Cardiac death (death in which a cardiac cause cannot be excluded)
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI
    • Ischemia-driven target vessel revascularization (TVR) by CABG or PCI

    Measured: 1 year

  5. Target Vessel Failure (TVF)

    The composite endpoint comprised of:

    • Cardiac death (death in which a cardiac cause cannot be excluded)
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI
    • Ischemia-driven target vessel revascularization (TVR) by CABG or PCI

    Measured: 2 year

  6. Target Vessel Failure (TVF)

    The composite endpoint comprised of:

    • Cardiac death (death in which a cardiac cause cannot be excluded)
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI
    • Ischemia-driven target vessel revascularization (TVR) by CABG or PCI

    Measured: 3 year

  7. Target Vessel Failure (TVF)

    The composite endpoint comprised of:

    • Cardiac death (death in which a cardiac cause cannot be excluded)
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI
    • Ischemia-driven target vessel revascularization (TVR) by CABG or PCI

    Measured: 4 year

  8. Ischemia Driven Target Lesion Revascularization (ID-TLR)

    Revascularization @ target lesion associated w/ any of following:

    (+) functional ischemia study Ischemic symptoms \& angiographic diameter stenosis ≥50% by core lab quantitative coronary angiography (QCA) Revascularization of a target lesion w/ angiographic diameter stenosis ≥70% by core laboratory QCA without angina or (+) functional study

    Measured: 30 days

  9. Ischemia Driven Target Lesion Revascularization (ID-TLR)

    Revascularization @ target lesion associated w/ any of following:

    (+) functional ischemia study Ischemic symptoms \& angiographic diameter stenosis ≥50% by core lab quantitative coronary angiography (QCA) Revascularization of a target lesion w/ angiographic diameter stenosis ≥70% by core laboratory QCA without angina or (+) functional study

    Measured: 180 days

  10. Ischemia Driven Target Lesion Revascularization (ID-TLR)

    Revascularization @ target lesion associated w/ any of following:

    (+) functional ischemia study Ischemic symptoms \& angiographic diameter stenosis ≥50% by core lab quantitative coronary angiography (QCA) Revascularization of a target lesion w/ angiographic diameter stenosis ≥70% by core laboratory QCA without angina or (+) functional study

    Measured: 270 days

  11. Ischemia Driven Target Lesion Revascularization (ID-TLR)

    Revascularization @ target lesion associated w/ any of following:

    (+) functional ischemia study Ischemic symptoms \& angiographic diameter stenosis ≥50% by core lab quantitative coronary angiography (QCA) Revascularization of a target lesion w/ angiographic diameter stenosis ≥70% by core laboratory QCA without angina or (+) functional study

    Measured: 1 years

  12. Ischemia Driven Target Lesion Revascularization (ID-TLR)

    Revascularization @ target lesion associated w/ any of following:

    (+) functional ischemia study Ischemic symptoms \& angiographic diameter stenosis ≥50% by core lab quantitative coronary angiography (QCA) Revascularization of a target lesion w/ angiographic diameter stenosis ≥70% by core laboratory QCA without angina or (+) functional study

    Measured: 2 years

  13. Ischemia Driven Target Lesion Revascularization (ID-TLR)

    Revascularization @ target lesion associated w/ any of following:

    (+) functional ischemia study Ischemic symptoms \& angiographic diameter stenosis ≥50% by core lab quantitative coronary angiography (QCA) Revascularization of a target lesion w/ angiographic diameter stenosis ≥70% by core laboratory QCA without angina or (+) functional study

    Measured: 3 year

  14. Ischemia Driven Target Lesion Revascularization (ID-TLR)

    Revascularization @ target lesion associated w/ any of following:

    (+) functional ischemia study Ischemic symptoms \& angiographic diameter stenosis ≥50% by core lab quantitative coronary angiography (QCA) Revascularization of a target lesion w/ angiographic diameter stenosis ≥70% by core laboratory QCA without angina or (+) functional study

    Measured: 4 year

  15. Ischemia Driven Target Vessel Revascularization (ID-TVR)

    Revascularization at the target vessel associated with any of the following

    • Positive functional ischemia study
    • Ischemic symptoms and angiographic diameter stenosis ≥ 50% by core laboratory QCA
    • Revascularization of a target vessel with angiographic diameter stenosis ≥ 70% by core laboratory QCA without angina or positive functional study

    Derived from Non-Hierarchical Subject Counts of Adverse Events

    Measured: 30 days

  16. Ischemia Driven Target Vessel Revascularization (ID-TVR)

    Revascularization at the target vessel associated with any of the following

    • Positive functional ischemia study
    • Ischemic symptoms and angiographic diameter stenosis ≥ 50% by core laboratory QCA
    • Revascularization of a target vessel with angiographic diameter stenosis ≥ 70% by core laboratory QCA without angina or positive functional study

    Derived from Non-Hierarchical Subject Counts of Adverse Events

    Measured: 180 days

  17. Ischemia Driven Target Vessel Revascularization (ID-TVR)

    Revascularization at the target vessel associated with any of the following

    • Positive functional ischemia study
    • Ischemic symptoms and angiographic diameter stenosis ≥ 50% by core laboratory QCA
    • Revascularization of a target vessel with angiographic diameter stenosis ≥ 70% by core laboratory QCA without angina or positive functional study

    Derived from Non-Hierarchical Subject Counts of Adverse Events

    Measured: 270 days

  18. Ischemia Driven Target Vessel Revascularization (ID-TVR)

    Revascularization at the target vessel associated with any of the following

    • Positive functional ischemia study
    • Ischemic symptoms and angiographic diameter stenosis ≥ 50% by core laboratory QCA
    • Revascularization of a target vessel with angiographic diameter stenosis ≥ 70% by core laboratory QCA without angina or positive functional study

    Derived from Non-Hierarchical Subject Counts of Adverse Events

    Measured: 1 year

  19. Ischemia Driven Target Vessel Revascularization (ID-TVR)

    Revascularization at the target vessel associated with any of the following

    • Positive functional ischemia study
    • Ischemic symptoms and angiographic diameter stenosis ≥ 50% by core laboratory QCA
    • Revascularization of a target vessel with angiographic diameter stenosis ≥ 70% by core laboratory QCA without angina or positive functional study

    Derived from Non-Hierarchical Subject Counts of Adverse Events

    Measured: 2 years

  20. Ischemia Driven Target Vessel Revascularization (ID-TVR)

    Revascularization at the target vessel associated with any of the following

    • Positive functional ischemia study
    • Ischemic symptoms and angiographic diameter stenosis ≥ 50% by core laboratory QCA
    • Revascularization of a target vessel with angiographic diameter stenosis ≥ 70% by core laboratory QCA without angina or positive functional study

    Derived from Non-Hierarchical Subject Counts of Adverse Events

    Measured: 3 years

  21. Ischemia Driven Target Vessel Revascularization (ID-TVR)

    Revascularization at the target vessel associated with any of the following

    • Positive functional ischemia study
    • Ischemic symptoms and angiographic diameter stenosis ≥ 50% by core laboratory QCA
    • Revascularization of a target vessel with angiographic diameter stenosis ≥ 70% by core laboratory QCA without angina or positive functional study

    Derived from Non-Hierarchical Subject Counts of Adverse Events

    Measured: 4 years

  22. Ischemia Driven Major Adverse Cardiac Event (MACE)

    The composite endpoint comprised of:

    • Cardiac death
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI

    Measured: 30 days

  23. Ischemia Driven Major Adverse Cardiac Event (MACE)

    The composite endpoint comprised of:

    • Cardiac death
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI

    Measured: 180 days

  24. Ischemia Driven Major Adverse Cardiac Event (MACE)

    The composite endpoint comprised of:

    • Cardiac death
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI

    Measured: 270 days

  25. Ischemia Driven Major Adverse Cardiac Event (MACE)

    The composite endpoint comprised of:

    • Cardiac death
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI

    Measured: 1 year

  26. Ischemia Driven Major Adverse Cardiac Event(MACE)

    The composite endpoint comprised of:

    • Cardiac death
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI

    Measured: 2 years

  27. Ischemia Driven Major Adverse Cardiac Event (MACE)

    The composite endpoint comprised of:

    • Cardiac death
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI

    Measured: 3 year

  28. Ischemia Driven Major Adverse Cardiac Event (MACE)

    The composite endpoint comprised of:

    • Cardiac death
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI

    Measured: 4 year

  29. In-stent % Angiographic Binary Restenosis (% ABR) Rate

    Percent of subjects with a follow-up in-stent percent diameter stenosis of ≥ 50% per quantitative coronary angiography (QCA)

    Measured: at 240 days

  30. In-segment % Angiographic Binary Restenosis (% ABR) Rate

    Percent of subjects with a follow-up in-segment percent diameter stenosis of ≥ 50% per QCA

    Measured: 240 days

  31. Persisting Incomplete Stent Apposition, Late-acquired Incomplete Stent Apposition, Aneurysm, Thrombosis, and Persisting Dissection

    Incomplete Apposition (Persisting \& Late acquired): Failure to completely appose vessel wall w/ ≥1 strut separated from vessel wall w/ blood behind strut per ultrasound. Aneurysm: Abnormal vessel expansion ≥ 1.5 of reference vessel diameter. Thrombus: Protocol \& ARC definition.

    Persisting dissection @ follow-up, present post-procedure.

    Measured: at 240 days

  32. Acute Success: Clinical Device

    Successful delivery and deployment of 1st implanted study stent/s @ the intended target lesion and successful withdrawal of the stent delivery system with final residual stenosis < 50%.

    Measured: In-hospital

  33. Acute Success: Clinical Procedure

    Successful delivery and deployment of study stent/s @ the intended target lesion and successful withdrawal of the stent delivery system with final residual stenosis < 50%.

    Measured: In-hospital

  34. Proximal Late Loss

    Proximal Minimum Lumen Diameter (MLD) post-procedure minus proximal MLD at follow-up (proximal defined as within 5 mm of healthy tissue proximal to stent placement)

    Measured: at 240 days

  35. Distal Late Loss

    Distal MLD post-procedure minus distal MLD at follow-up (distal defined as within 5 mm of healthy tissue distal to stent placement)

    Measured: 240 days

  36. In-stent Late Loss

    In-stent MLD post-procedure minus in-stent MLD at follow-up (in-stent defined as within the margins of the stent)

    Measured: at 240 days

  37. % Volume Obstruction (% VO)

    Defined as stent intimal hyperplasia and calculated as 100*(Stent Volume - Lumen Volume)/Stent Volume by IVUS.

    Measured: at 240 days

  38. In-stent % Diameter Stenosis (% DS)

    In-stent: Within the margins of the stent, the value calculated as 100 * (1 - in-stent MLD/RVD) using the mean values from two orthogonal views (when possible) by QCA.

    Measured: at 240 days

  39. In-segment % Diameter Stenosis (% DS)

    Within the margins of the stent, 5 mm proximal and 5 mm distal to the stent, the value calculated as 100 * (1 - in-segment MLD/RVD) using the mean values from two orthogonal views (when possible) by QCA.

    Measured: 240 days

  40. Target Vessel Failure (TVF)

    The composite endpoint comprised of:

    • Cardiac death (death in which a cardiac cause cannot be excluded)
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI
    • Ischemia-driven target vessel revascularization (TVR) by CABG or PCI

    Measured: 5 years

  41. Ischemia Driven Target Lesion Revascularization (ID-TLR)

    Revascularization @ target lesion associated w/ any of following:

    (+) functional ischemia study Ischemic symptoms \& angiographic diameter stenosis ≥50% by core lab quantitative coronary angiography (QCA) Revascularization of a target lesion w/ angiographic diameter stenosis ≥70% by core laboratory QCA without angina or (+) functional study

    Measured: 5 years

  42. Ischemia Driven Target Vessel Revascularization (ID-TVR)

    Revascularization at the target vessel associated with any of the following

    • Positive functional ischemia study
    • Ischemic symptoms and angiographic diameter stenosis ≥ 50% by core laboratory QCA
    • Revascularization of a target vessel with angiographic diameter stenosis ≥ 70% by core laboratory QCA without angina or positive functional study

    Derived from Non-Hierarchical Subject Counts of Adverse Events

    Measured: 5 years

  43. Ischemia Driven Major Adverse Cardiac Event (MACE)

    The composite endpoint comprised of:

    • Cardiac death
    • Myocardial infarction (MI, classified as Q-wave and non-Q wave)
    • Ischemia-driven target lesion revascularization (TLR) by CABG or PCI

    Measured: 5 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 Sep 2005 (estimated)
  2. Study startJun 2005
  3. Primary completionDec 2006
  4. Study completionNov 2011

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 3
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
1,002 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00180479
Sponsor's protocol ID
03-360
Status last verified
Nov 2011
First submitted
13 Sep 2005
Last updated
23 Nov 2011
Data monitoring committee
Yes

Publications

  • Stone GW, Midei M, Newman W, Sanz M, Hermiller JB, Williams J, Farhat N, Mahaffey KW, Cutlip DE, Fitzgerald PJ, Sood P, Su X, Lansky AJ; SPIRIT III Investigators. Comparison of an everolimus-eluting stent and a paclitaxel-eluting stent in patients with coronary artery disease: a randomized trial. JAMA. 2008 Apr 23;299(16):1903-13. doi: 10.1001/jama.299.16.1903.

    PubMed 18430909
  • Stone GW, Midei M, Newman W, Sanz M, Hermiller JB, Williams J, Farhat N, Caputo R, Xenopoulos N, Applegate R, Gordon P, White RM, Sudhir K, Cutlip DE, Petersen JL; SPIRIT III Investigators. Randomized comparison of everolimus-eluting and paclitaxel-eluting stents: two-year clinical follow-up from the Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients with de novo Native Coronary Artery Lesions (SPIRIT) III trial. Circulation. 2009 Feb 10;119(5):680-6. doi: 10.1161/CIRCULATIONAHA.108.803528. Epub 2009 Jan 26.

    PubMed 19171853
  • Lansky AJ, Ng VG, Mutlu H, Cristea E, Guiran JB, Midei M, Newman W, Sanz M, Sood P, Doostzadeh J, Su X, White R, Cao S, Sudhir K, Stone GW. Gender-based evaluation of the XIENCE V everolimus-eluting coronary stent system: clinical and angiographic results from the SPIRIT III randomized trial. Catheter Cardiovasc Interv. 2009 Nov 1;74(5):719-27. doi: 10.1002/ccd.22067.

    PubMed 19530147
  • Genereux P, Rutledge DR, Palmerini T, Caixeta A, Kedhi E, Hermiller JB, Wang J, Krucoff MW, Jones-McMeans J, Sudhir K, Simonton CA, Serruys PW, Stone GW. Stent Thrombosis and Dual Antiplatelet Therapy Interruption With Everolimus-Eluting Stents: Insights From the Xience V Coronary Stent System Trials. Circ Cardiovasc Interv. 2015 May;8(5):e001362. doi: 10.1161/CIRCINTERVENTIONS.114.001362.

    PubMed 25940520
  • Muramatsu T, Onuma Y, van Geuns RJ, Chevalier B, Patel TM, Seth A, Diletti R, Garcia-Garcia HM, Dorange CC, Veldhof S, Cheong WF, Ozaki Y, Whitbourn R, Bartorelli A, Stone GW, Abizaid A, Serruys PW; ABSORB Cohort B Investigators; ABSORB EXTEND Investigators; SPIRIT FIRST Investigators; SPIRIT II Investigators; SPIRIT III Investigators; SPIRIT IV Investigators. 1-year clinical outcomes of diabetic patients treated with everolimus-eluting bioresorbable vascular scaffolds: a pooled analysis of the ABSORB and the SPIRIT trials. JACC Cardiovasc Interv. 2014 May;7(5):482-93. doi: 10.1016/j.jcin.2014.01.155. Epub 2014 Apr 16.

    PubMed 24746650
  • Claessen BE, Smits PC, Kereiakes DJ, Parise H, Fahy M, Kedhi E, Serruys PW, Lansky AJ, Cristea E, Sudhir K, Sood P, Simonton CA, Stone GW. Impact of lesion length and vessel size on clinical outcomes after percutaneous coronary intervention with everolimus- versus paclitaxel-eluting stents pooled analysis from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials. JACC Cardiovasc Interv. 2011 Nov;4(11):1209-15. doi: 10.1016/j.jcin.2011.07.016.

    PubMed 22115661
  • Planer D, Smits PC, Kereiakes DJ, Kedhi E, Fahy M, Xu K, Serruys PW, Stone GW. Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) Trials. JACC Cardiovasc Interv. 2011 Oct;4(10):1104-15. doi: 10.1016/j.jcin.2011.06.018.

    PubMed 22017936
  • Kereiakes DJ, Sudhir K, Hermiller JB, Gordon PC, Ferguson J, Yaqub M, Sood P, Su X, Yakubov S, Lansky AJ, Stone GW. Comparison of everolimus-eluting and paclitaxel-eluting coronary stents in patients undergoing multilesion and multivessel intervention: the SPIRIT III (A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With De Novo Native Coronary Artery Lesions) and SPIRIT IV (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With De Novo Native Coronary Artery Lesions) randomized trials. JACC Cardiovasc Interv. 2010 Dec;3(12):1229-39. doi: 10.1016/j.jcin.2010.09.014.

    PubMed 21232716
  • Caixeta A, Lansky AJ, Serruys PW, Hermiller JB, Ruygrok P, Onuma Y, Gordon P, Yaqub M, Miquel-Hebert K, Veldhof S, Sood P, Su X, Jonnavithula L, Sudhir K, Stone GW; SPIRIT II and III Investigators. Clinical follow-up 3 years after everolimus- and paclitaxel-eluting stents: a pooled analysis from the SPIRIT II (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) and SPIRIT III (A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With De Novo Native Coronary Artery Lesions) randomized trials. JACC Cardiovasc Interv. 2010 Dec;3(12):1220-8. doi: 10.1016/j.jcin.2010.07.017.

    PubMed 21232715

Questions about this trial

What is this clinical trial studying?

A Phase 3 study testing XIENCE V® Everolimus Eluting Coronary Stent and TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent in people with Stents and Coronary Artery Disease, run by Abbott Medical Devices at 65 sites in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 23 Nov 2011. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 65 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 3 studies compare the treatment with the current standard treatment or a placebo in a large group, to confirm how well it works and watch for side effects.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Yes. Results are posted in the registry (first posted 15 Dec 2008). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Primary Endpoint: In-segment Late Loss (LL) (time frame: 240 days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00180479, which also lists 9 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Nov 2011.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in