AzTrials
AzTrials

Cerebrovascular AccidentDefinityNCT00239525

3-D Transcranial Ultrasound Analysis Study

A study testing 3-D ultrasound scanner and Perflutren Protein-Type A Microspheres for injection in people with Cerebrovascular Accident and Intracranial Hypertension, run by Duke University at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to investigate real time 3-D ultrasound imaging of the brain for the diagnosis and evaluation of stroke. Read more about this study

Who is it for?
Ages 18 to 65 yearsHealthy volunteers can take part
What is being tested?
3-D ultrasound scanner and Perflutren Protein-Type A Microspheres for injection
How many people
28 participants
Where
1 siteUnited States
Study dates
May 2006to Dec 2013
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 65 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

None listed.

Who cannot join

  • persons <18 years old
  • pregnant or nursing women
  • history of neurological disease
  • congenital heart defect
  • severe liver dysfunction
  • respiratory distress syndrome
  • hypersensitivity or an allergic reaction to blood products.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Duke University Medical Center

    Durham, North Carolina, 27710

Other trials in United States

About this study

Official title: 3-D Transcranial Ultrasound Analysis Using Definity Injectable Suspension

The purpose of this study is to investigate real time 3-D ultrasound imaging of the brain for the diagnosis and evaluation of stroke.

Read the detailed description

The objective of this proposal is to extend our previous advances to investigate real time 3-D ultrasound imaging of the brain for the diagnosis and evaluation of stroke. Over the last decade, with the availability of color flow Doppler combined with effective ultrasound contrast agents, a renaissance has occurred in transcranial sonography as a low cost, bedside method for evaluation and management of patients with cerebrovascular disease in spite of the image degrading properties of the skull. Our hypothesis is that we can combine new generations of 2D array transducers with ultrasound contrast agents and phase aberration correction to enable real time 3D ultrasound imaging and 3D color flow Doppler of the brain with a factor of 10 improvement in spatial resolution compared to conventional transcranial sonography for improved diagnosis and evaluation of stroke.

Being tested
3-D ultrasound scanner, Perflutren Protein-Type A Microspheres for injection
Keywords
Cerebrovascular Accident, Intracranial Hypertension
Medical subject headings
Stroke, Intracranial Hypertension

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • 3-D ultrasound scannerDevice

    The availability of color flow Doppler combined with effective ultrasound contrast agents in transcranial sonography serves as a low cost, bedside method for evaluation and management of patients with cerebrovascular disease in spite of the image degrading properties of the skull.

  • Perflutren Protein-Type A Microspheres for injectionDrug

    Also called Definity

    Activated DEFINITY® (Perflutren Lipid Microsphere) Injectable Suspension is indicated for use in patients with suboptimal echocardiograms to opacify the left ventricular chamber and to improve the delineation of the left ventricular endocardial border.Bolus: The recommended dose for activated DEFINITY® is 10 microliters (μL)/kg of the activated product by intravenous bolus injection within 30-60 seconds, followed by a 10 mL saline flush. If necessary, a second 10 microliters (μL)/kg dose followed by a second 10 mL saline flush may be administered 30 minutes after the first injection to prolong contrast enhancement. Infusion: The recommended dose for activated DEFINITY® is via an IV infusion of 1.3 mL added to 50 mL of preservative-free saline. The rate of infusion should be initiated at 4.0 mL/minute, but titrated as necessary to achieve optimal image enhancement, not to exceed 10 mL/minute.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Phase aberration correction of skull bone

    This study will look to improve adaptive signal processing techniques for phase aberration correction of the skull while incorporating ultrasound contrast agent to increase signal to noise ratio in an ultrasound B-scan system with high speed RF data acquisition and 2-D arrays.In addition,we hope to develop adaptive transcranial real time 3D ultrasound and real time 3D color flow Doppler scanning of the brain incorporating ultrasound contrast agent to increase signal to noise ratio. A clinical evaluation of adaptive transcranial ultrasound imaging of the brain with phase aberration correction and ultrasound contrast agent will be conducted.

    Measured: 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Oct 2005 (estimated)
  2. Study startMay 2006
  3. Primary completionApr 2007
  4. Study completionDec 2013

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
28 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00239525
Sponsor's protocol ID
Pro00008393
Acronym
Definity
Status last verified
Apr 2014
First submitted
13 Oct 2005
Last updated
11 Apr 2014
Results posted
No
Data monitoring committee
Yes

Publications

  • Lindsey BD, Light ED, Nicoletto HA, Bennett ER, Laskowitz DT, Smith SW. The ultrasound brain helmet: new transducers and volume registration for in vivo simultaneous multi-transducer 3-D transcranial imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2011 Jun;58(6):1189-202. doi: 10.1109/TUFFC.2011.1929.

    PubMed 21693401
  • Ivancevich NM, Pinton GF, Nicoletto HA, Bennett E, Laskowitz DT, Smith SW. Real-time 3-D contrast-enhanced transcranial ultrasound and aberration correction. Ultrasound Med Biol. 2008 Sep;34(9):1387-95. doi: 10.1016/j.ultrasmedbio.2008.01.015. Epub 2008 Apr 18.

    PubMed 18395321
  • Smith SW, Ivancevich NM, Lindsey BD, Whitman J, Light E, Fronheiser M, Nicoletto HA, Laskowitz DT. The ultrasound brain helmet: feasibility study of multiple simultaneous 3D scans of cerebral vasculature. Ultrasound Med Biol. 2009 Feb;35(2):329-38. doi: 10.1016/j.ultrasmedbio.2008.08.016. Epub 2008 Oct 23.

    PubMed 18947918

Questions about this trial

What is this clinical trial studying?

A study testing 3-D ultrasound scanner and Perflutren Protein-Type A Microspheres for injection in people with Cerebrovascular Accident and Intracranial Hypertension, run by Duke University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 0 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 11 Apr 2014. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Phase aberration correction of skull bone (time frame: 6 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00239525, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Apr 2014.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
3-D Transcranial Ultrasound Analysis Study | AzTrials