Coronary Artery DiseasePhase 2NCT00299026
A Randomized, Double-Blind, Controlled Study of the Safety and Performance of the NIRx™ Paclitaxel-Coated Conformer Coronary Stent
A Phase 2 study testing NIRx(TM) Paclitaxel-Coated Conformer Coronary Stent System in people with Coronary Artery Disease, run by Boston Scientific Corporation at 1 site in Italy.
Trial summary
The clinical investigation is an international, prospective, double-blind, randomized safety and efficacy study. The purpose of this study is to evaluate the safety and performance of the NIRx(TM) Paclitaxel-Coated Stent (1.0µg/mm2 of paclitaxel incorporated into slow- and moderate-release formulation of a triblock… Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Coronary Artery Disease
- What is being tested?
- NIRx(TM) Paclitaxel-Coated Conformer Coronary Stent System
- Type of treatment
- Medical device
- How many people
- 532 participants
- Where
- 1 siteItaly
- Study dates
- Jun 2001to Feb 2007
- Phase
- Phase 2
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
General Inclusion Criteria:
- Patient >= 18 years old.
- Eligible for percutaneous transluminal coronary angioplasty (PTCA).
- Patient (or legal guardian) understands the study requirements and the stent treatment procedure and provides written Informed Consent before any study-specific tests or procedures are performed.
- Willing to comply with all specified follow-up evaluations.
- Documented stable angina pectoris (Canadian Cardiovascular Society Classification [CCS] 1, 2, 3, or 4), unstable angina pectoris with documented ischemia (Braunwald Class IB - C, IIB - C, or IIIB - C), or documented silent ischemia.
- Acceptable candidate for CABG.
Angiographic Inclusion Criteria:
- Target lesion is located within a native coronary vessel.
- Target lesion is de novo (i.e., a coronary lesion not previously treated).
- Target lesion diameter stenosis >= 50% and <= 99% (visual estimate or on-line QCA).
- Target lesion <= 12 mm in length (visual estimate or on-line QCA).
- Target vessel >= 3.0 mm and <= 3.5 mm in diameter (visual estimate or on-line QCA).
General Exclusion Criteria:
- Known sensitivity to paclitaxel.
- Patient has received paclitaxel or other anti-mitogenic agent within 12 months prior to planned enrollment in the study.
- Patient has previous stent procedure with any drug-coated or drug-eluting stent device.
- Patient has undergone any coronary intervention within 30 days prior to stent placement associated with this protocol.
- Patient anticipates planned additional intervention (staged procedure) to any non-target coronary vessel within 45 days after the stent placement associated with this protocol.
- MI within 72 hours of planned stent placement.
- Left ventricular ejection fraction (LVEF) of < 30%.
- Stroke within the past 6 months.
- Acute or chronic renal dysfunction (creatinine >1.7 mg/mL or >150 µmol/L).
- Acetylsalicylic acid and/or clopidogrel and/or ticlopidine are contraindicated.
- Leukopenia (leukocytes <3.5 x 109/liter).
- Thrombocytopenia (platelets <100,000/mm3).
- Active peptic ulcer or active gastrointestinal (GI) bleeding.
- Known allergy to stainless steel.
- Previously enrolled in the NIRx(TM) Coronary Stent Clinical Safety and Performance Study.
- Currently enrolled in another investigational device or drug study and has not completed the required follow-up period, or has completed all other study-required follow-up less than 30 days prior to enrollment in this study.
- Patient is lactating, has a positive pregnancy test within 7 days of planned stent placement, or intends to become pregnant during the study (only applies to female patients of child-bearing potential).
- Life expectancy of less than 24 months because of other medical conditions.
- Co-morbid condition(s) that could limit the patient's ability to participate in the study or comply with follow-up requirements or co-morbid condition(s) that could impact the scientific integrity of the study.
Angiographic Exclusion Criteria:
- Unprotected left main coronary artery disease (or obstruction greater than 50% in the left main coronary artery that is not protected by at least 1 non-obstructed bypass graft to the left anterior descending [LAD] or circumflex artery or a branch thereof).
- Target lesion is in a previously stented segment.
- Target vessel was treated with directional coronary atherectomy, laser, or transluminal extraction catheter prior to stent placement.
- Target lesion is ostial in location (within 3 mm of vessel origin).
- Target site of stent placement has side branches >2.0 mm in diameter.
- Target lesion is severely calcified (by visual estimate)
- Target vessel has closed abruptly or is threatening closure.
- Target lesion is located within or immediately distal to a >60° bend in the vessel.
- Target vessel has diffuse disease requiring more than one 15 mm stent for full lesion coverage.
- Target lesion involves a bifurcation where a branch vessel greater than 2.0 mm in diameter originates (either stenosis of both main vessel and major branch or stenosis of just major branch).
- Target lesion has excessive tortuosity unsuitable for stent delivery and deployment.
- Target lesion is located within a saphenous vein bypass graft.
- Target lesion is located in a vessel section supplied by distal graft.
Trial locations and contacts
1 site in 1 country.
About this study
Official title: TAXUS II: A Randomized, Double-Blind, Controlled Study of the Safety and Performance of the NIRx™ Paclitaxel-Coated Conformer Coronary Stent
The clinical investigation is an international, prospective, double-blind, randomized safety and efficacy study. The purpose of this study is to evaluate the safety and performance of the NIRx(TM) Paclitaxel-Coated Stent (1.0µg/mm2 of paclitaxel incorporated into slow- and moderate-release formulation of a triblock copolymer carrier system)in patients who present for stenting of de novo lesions of a native coronary artery.
Read the detailed description
The primary objective of this study is to evaluate the safety and performance of coronary artery stenting with the NIRx(TM) Paclitaxel-Coated Stent (1.0µg/mm2 of paclitaxel incorporated into slow- and moderate-release formulation of a triblock copolymer carrier system) for the treatment of de novo lesions in native vessels. Patients in 2 sequential cohorts will be randomised to receive either the NIRx(TM) Paclitaxel-Coated Stent or the uncoated control stent. In cohort 1, the slow-release formulation NIRx(TM) Paclitaxel-Coated Stent will be studied. If the safety profile is acceptable, the moderate-release formulation NIRx(TM) Paclitaxel-Coated Stent will be studied in Cohort 2. In each f the 2 cohorts, 133 patients will be treated with the NIRx(TM) paclitaxel-Coated Stent and 133 with the uncoated control stent (1.1 ratio), for a total of 532 patients in study.
- Conditions
- Coronary Artery Disease
- Being tested
- NIRx(TM) Paclitaxel-Coated Conformer Coronary Stent System
- Keywords
- Coronary Artery Disease, Percutaneous Coronary Intervention, Stent Implant, Drug-coated Stent
- Medical subject headings
- Coronary Artery Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
NIRx(TM) Paclitaxel-Coated Conformer Coronary Stent SystemDevice
What is being measured
The primary outcome is the main question the study is designed to answer.
Mean percent in-stent net volume obstruction at 6 months post-procedure as measured by IVUS
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted6 Mar 2006 (estimated)
- Study startJun 2001
- Primary completionMay 2003
- Study completionFeb 2007
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- More trials run by Boston Scientific CorporationThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 2
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind
- Enrolment
- 532 participants
Sponsor and investigators
- Lead sponsor
- Boston Scientific Corporation
- Sponsor type
- Industry (pharma, biotech, devices)
- Investigators
- Antonio Colombo, MD, Principal investigator, Ospedale San Raffaele del Monte Tabor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT00299026
- Sponsor's protocol ID
- TAXUS II
- Other IDs
- S2003
- Status last verified
- Mar 2017
- First submitted
- 3 Mar 2006
- Last updated
- 3 Mar 2017
- Results posted
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Silber S, Colombo A, Banning AP, Hauptmann K, Drzewiecki J, Grube E, Dudek D, Baim DS. Final 5-year results of the TAXUS II trial: a randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for de novo coronary artery lesions. Circulation. 2009 Oct 13;120(15):1498-504. doi: 10.1161/CIRCULATIONAHA.109.849877. Epub 2009 Sep 28.
PubMed 19786634
Study at a glance
From the registry record, last updated by the sponsor on 3 Mar 2017. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- TAXUS II: A Randomized, Double-Blind, Controlled Study of the Safety and Performance of the NIRx™ Paclitaxel-Coated Conformer Coronary Stent
- ClinicalTrials.gov ID
- NCT00299026
- Acronym / sponsor ID
- TAXUS II
- Conditions
- Coronary Artery Disease
- Keywords
- Coronary Artery Disease, Percutaneous Coronary Intervention, Stent Implant, Drug-coated Stent
- Phase
- Phase 2
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 532 participants
- Lead sponsor
- Boston Scientific CorporationIndustry (pharma, biotech, devices)
- Study start
- Jun 2001
- Primary completion
- May 2003 (actual)
- Study completion
- Feb 2007 (actual)
- First posted
- 6 Mar 2006 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The clinical investigation is an international, prospective, double-blind, randomized safety and efficacy study. The purpose of this study is to evaluate the safety and performance of the NIRx(TM) Paclitaxel-Coated Stent (1.0µg/mm2 of paclitaxel incorporated into slow- and moderate-release formulation of a triblock copolymer carrier system)in patients who present for stenting of de novo lesions of a native coronary artery.
Detailed description
The primary objective of this study is to evaluate the safety and performance of coronary artery stenting with the NIRx(TM) Paclitaxel-Coated Stent (1.0µg/mm2 of paclitaxel incorporated into slow- and moderate-release formulation of a triblock copolymer carrier system) for the treatment of de novo lesions in native vessels. Patients in 2 sequential cohorts will be randomised to receive either the NIRx(TM) Paclitaxel-Coated Stent or the uncoated control stent. In cohort 1, the slow-release formulation NIRx(TM) Paclitaxel-Coated Stent will be studied. If the safety profile is acceptable, the moderate-release formulation NIRx(TM) Paclitaxel-Coated Stent will be studied in Cohort 2. In each f the 2 cohorts, 133 patients will be treated with the NIRx(TM) paclitaxel-Coated Stent and 133 with the uncoated control stent (1.1 ratio), for a total of 532 patients in study.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| NIRx(TM) Paclitaxel-Coated Conformer Coronary Stent System | Device | – |
Primary outcome
Mean percent in-stent net volume obstruction at 6 months post-procedure as measured by IVUS
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 3 Mar 2017.
- Derived from this study: PubMed 19786634Silber S, Colombo A, Banning AP, Hauptmann K, Drzewiecki J, Grube E, Dudek D, Baim DS. Final 5-year results of the TAXUS II trial: a randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for de novo coronary artery lesions. Circulation. 2009 Oct 13;120(15):1498-504. doi: 10.1161/CIRCULATIONAHA.109.849877. Epub 2009 Sep 28.
- Individual participant dataSharing planned: No
Related trials for Coronary Artery Disease
Not yet recruitingObservational study
Assessment of Transnational Performance of the Universal Cardiac Surgical Risk Score Across International Sites
Heart Valve Diseases, Cardiac Surgical Procedures
Not yet recruiting
Sirolimus-Coated Versus Paclitaxel-Coated Balloon for Recurrent Coronary In-Stent Restenosis After Prior Paclitaxel-Coated Balloon Treatment (SPRIT)
Coronary In-stent Restenosis, Coronary Artery Disease
RecruitingObservational study
Norepinephrine in the Management of General Anesthesia-Induced Arterial Hypotension in Chronic Heart Failure Patients
Hypotension
Active, not recruitingObservational study
The CoPenHagen PREeClampsia and cardIOvascUlar diSease Study
Pre-Eclampsia, Atherosclerosis
RecruitingObservational study
Cardiovascular Risk Assessment For Kidney Transplantation - Utility of Computed Tomography Coronary Angiography in the Assessment of Patients Awaiting Kidney Transplantation
Cardiovascular Diseases, Kidney Transplant; Complications
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Antonio Colombo, MD principal investigator
Ospedale San Raffaele del Monte Tabor
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 2 study testing NIRx(TM) Paclitaxel-Coated Conformer Coronary Stent System in people with Coronary Artery Disease, run by Boston Scientific Corporation at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 3 Mar 2017. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Mean percent in-stent net volume obstruction at 6 months post-procedure as measured by IVUS. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT00299026, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 3 Mar 2017; AzTrials last refreshed its copy on 6 Nov 2026.