AzTrials
AzTrials

Sudden Cardiac DeathPhase 4NCT00311181

POWER (Pulse Width Optimized Waveform Evaluation Trial)

A Phase 4 study testing Implantable Cardioverter Defibrillator (ICD), Cardiac Resynchronization Therapy (CRT-D) in people with Sudden Cardiac Death, run by Abbott Medical Devices at 2 sites in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The objective of this study is to compare the ULV (Upper Limit of Vulnerability)/DFT (Defibrillation Threshold) efficacy between the 2.5, 3.5 and 4.5 ms membrane time constant based biphasic defibrillation waveforms. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Sudden Cardiac Death
What is being tested?
Implantable Cardioverter Defibrillator (ICD), Cardiac Resynchronization Therapy (CRT-D)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
217 participants
Where
2 sitesUnited States
Study dates
Aug 2006to Apr 2008
Phase
Phase 4
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patient is a candidate for ICD/CRT-D implantation.
  • Patient has a compatible transvenous defibrillation lead system.
  • Patient has had an echocardiogram, MUGA, or cath procedure within 6 months of ICD/CRT-D implant.
  • Patient is able to tolerate ULV guided DFT testing.

Who cannot join

  • Patient has a mechanical valve in the tricuspid position.
  • Patient has epicardial defibrillation electrodes.
  • Patient is pregnant.
  • Patient is less than 18 years old.

Trial locations and contacts

2 sites in 1 country.

United States2 sites
  • Baptist Medical Center Montclair

    Birmingham, Alabama, 35212

  • Pacific Heart Institute

    Santa Monica, California, 90404

Other trials in United States

About this study

Official title: Phase 4 Study That Compares the DFT (Defibrillation Threshold) Efficacy of 3 Different Membrane Time Constant Based Biphasic Defibrillation Waveforms

The objective of this study is to compare the ULV (Upper Limit of Vulnerability)/DFT (Defibrillation Threshold) efficacy between the 2.5, 3.5 and 4.5 ms membrane time constant based biphasic defibrillation waveforms. This comparison will result in identifying the optimal membrane time constant when programming the "tuned" defibrillation waveform.

Read the detailed description

Sudden cardiac death (SCD) continues to be a significant cause of cardiac mortality with annual deaths ranging from 250,000 to 400,000 in the United States. Accordingly, implantable cardioverter-defibrillators (ICD's) have proven to be an important therapeutic option for patients susceptible to SCD. Successful therapy and generator longevity are greatly dependent on proper defibrillation threshold (DFT) determination.

All modern ICD's utilize a biphasic waveform for defibrillation. It has been clearly shown that biphasic waveforms reduce the energy required for internal defibrillation of the heart. However, there is no consensus on which pulse widths are best for defibrillation.

St. Jude Medical ICD's (implantable cardioverter defibrillators) have programmable pulse widths, which allow the physician multiple options in dealing with ICD patients. By implanting ICD's with programmable pulse widths, this study utilizes the Tissue RC Resistance/Capacitance) model to try to identify the optimal pulse widths.

To determine the efficacy of an optimal membrane time constant estimate for the "tuned" waveform, defibrillation testing must be performed. Upper limit of vulnerability (ULV) has been proposed as an alternative means of predicting the DFT and it has been shown that ULV guided DFT testing can achieve a defibrillation success rate of 95%.

Being tested
Implantable Cardioverter Defibrillator (ICD), Cardiac Resynchronization Therapy (CRT-D)
Keywords
ICD, Defibrillation, ULV, Tuned
Medical subject headings
Death, Sudden, Cardiac

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Implantable Cardioverter Defibrillator (ICD), Cardiac Resynchronization Therapy (CRT-D)Device

    Patients that are indicated for an ICD or CRT-D receive one of these devices.

Study groups in NCT00311181
Study groupRoleWhat they receive
2.5/3.5/4.5 ms defibrillation waveformExperimentalNot described
Receives: Device: Implantable Cardioverter Defibrillator (ICD), Cardiac Resynchronization Therapy (CRT-D)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Defibrillation Thresholds (DFTs) (3.5 ms Waveform)

    Measured: Implant

  2. DFT (2.5 ms Waveform)

    Measured: Implant

  3. DFT (4.5 ms Waveform)

    Measured: Implant

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Apr 2006 (estimated)
  2. Study startAug 2006
  3. Primary completionApr 2008
  4. Study completionApr 2008

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Single group
Masking
Single blind
Who is masked
Participant
Enrolment
217 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00311181
Sponsor's protocol ID
CRD 324
Status last verified
Feb 2019
First submitted
3 Apr 2006
Last updated
20 Feb 2019
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing Implantable Cardioverter Defibrillator (ICD), Cardiac Resynchronization Therapy (CRT-D) in people with Sudden Cardiac Death, run by Abbott Medical Devices at 2 sites in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 20 Feb 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Yes. Results are posted in the registry (first posted 30 Aug 2012). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Defibrillation Thresholds (DFTs) (3.5 ms Waveform) (time frame: Implant). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Feb 2019.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in