AzTrials
AzTrials

Coronary Heart DiseasePhase 4NCT00350454

Rapamycin-Eluting Stents With Different Polymer Coating to Reduce Restenosis (ISAR-TEST-3)

A Phase 4 study testing rapamycin-eluting Stent with permanent polymer, rapamycin-eluting stent with biodegradable polymer and polymer-free, rapamycin-eluting stent in people with Coronary Heart Disease, run by Deutsches Herzzentrum Muenchen at 2 sites in Germany.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to evaluate the efficacy of 3 different rapamycin-eluting-stent platforms to reduce coronary artery reblockage after stent implantation Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Coronary Heart Disease
What is being tested?
rapamycin-eluting Stent with permanent polymer, rapamycin-eluting stent with biodegradable polymer and polymer-free, rapamycin-eluting stent
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
605 participants
Where
2 sitesGermany
Study dates
Jun 2006to Oct 2007
Phase
Phase 4
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients older than age 18 with ischemic symptoms or evidence of myocardial ischemia in the presence of ≥50% de novo stenosis located in native coronary vessels.
  • Written, informed consent by the patient or her/his legally-authorized representative for participation in the study.

Who cannot join

  • Target lesion located in the left main trunk or bypass graft.
  • In-stent restenosis.
  • Cardiogenic shock.
  • Malignancies or other comorbid conditions (for example severe liver, renal and pancreatic disease) with life expectancy less than 12 months or that may result in protocol non-compliance.
  • Known allergy to the study medications: aspirin, clopidogrel, rapamycin, stainless steel.
  • Pregnancy (present, suspected or planned) or positive pregnancy test.
  • Previous enrollment in this trial.
  • Patient's inability to fully cooperate with the study protocol.

Trial locations and contacts

2 sites in 1 country.

Germany2 sites
  • 1. Medizinische Klinik, Klinikum rechts der Isar

    München, 81675

  • Deutsches Herzzentrum Muenchen

    Munich, 80636

Other trials in Germany

About this study

Official title: Prospective, Randomized Trial of 3 Rapamycin-Eluting Stents With Different Polymer Coating Strategies For The Reduction of Coronary Restenosis (ISAR-TEST-3)

The purpose of this study is to evaluate the efficacy of 3 different rapamycin-eluting-stent platforms to reduce coronary artery reblockage after stent implantation

Read the detailed description

Coronary artery reblockage remains still a drawback of percutaneous coronary interventions even in the era of drug-eluting stents (DES). DESs working principle consists of the delivery of controlled amounts of antiproliferative agents at the local level, which results in the suppression of neointimal proliferation, the main cause of lumen re-narrowing after stent implantation. At present, several DES platforms have been developed and evaluated for clinical use. They differ between them with regard to the stent type, anti-proliferative drug, presence of polymers employed for drug storage and modification of drug-release kinetics as well as type of polymer used for this purpose. Although their mid-term efficacy has been well-established, there is an ongoing debate on the potential of an increased incidence of late stent thrombosis, particularly after discontinuation of thienopyridine therapy, as well as of delayed onset of restenosis or catch-up phenomenon with DESs. Based on animal and human pathological data, investigators have linked the above-mentioned concerns to the presence of polymers in DESs, which have a proinflammatory and prothrombinogenic potential, and sometimes may induce a hypersensitivity reaction. This trial will compare the anti-restenotic efficacy of the permanent polymer (PP), biodegradable polymer (BP) and polymer-free (PF) rapamycin-eluting stents in patients with coronary artery disease. Cypher stent (PP) is a stainless steel stent coated with sirolimus with use of permanent polymers while the ISAR stent is a rough surface stainless steel stent which allows not only polymeric coating (for example biodegradable polymer, BP ISAR stent) but also coating without the need of polymer (PF ISAR stent) in the cath lab.

Being tested
rapamycin-eluting Stent with permanent polymer, rapamycin-eluting stent with biodegradable polymer, polymer-free, rapamycin-eluting stent
Medical subject headings
Coronary Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • rapamycin-eluting Stent with permanent polymerDevice

    due to randomization, rapamycin-eluting stent with permanent polymer will be implanted

  • rapamycin-eluting stent with biodegradable polymerDevice

    due to randomization, rapamycin-eluting stent with biodegradable polymer will be implanted

  • polymer-free, rapamycin-eluting stentDevice

    due to randomization, polymer-free.rapamycin-eluting stent will be implanted

Study groups in NCT00350454
Study groupRoleWhat they receive
AActive comparatorDrug eluting stent using biodegradable polymer BP stent
Receives: Device: rapamycin-eluting stent with biodegradable polymer
BActive comparatorpolymer-free drug eluting stent PF stent
Receives: Device: polymer-free, rapamycin-eluting stent
CActive comparatorpermanent polymer using stents PP stent
Receives: Device: rapamycin-eluting Stent with permanent polymer

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. in-stent late luminal loss

    Measured: at 6 to 8-month follow-up angiogram

Secondary outcomes (4)
  1. In-segment binary angiographic restenosis

    Measured: at 6 to 8-month follow-up angiogram

  2. Need of target lesion revascularization

    Measured: at 9-month follow-up

  3. Combined incidence of death or myocardial infarction

    Measured: at 9-month follow-up

  4. Incidence of stent thrombosis.

    Measured: at 9-month follow-up

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted10 Jul 2006 (estimated)
  2. Study startJun 2006
  3. Primary completionSep 2007
  4. Study completionOct 2007

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
605 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00350454
Sponsor's protocol ID
GE IDE No. S02306
Status last verified
Jan 2008
First submitted
7 Jul 2006
Last updated
11 Jan 2008
Results posted
No
Data monitoring committee
Yes

Publications

  • Sousa JE, Serruys PW, Costa MA. New frontiers in cardiology: drug-eluting stents: Part I. Circulation. 2003 May 6;107(17):2274-9. doi: 10.1161/01.CIR.0000069330.41022.90. No abstract available.

    PubMed 12732594
  • Babapulle MN, Joseph L, Belisle P, Brophy JM, Eisenberg MJ. A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents. Lancet. 2004 Aug 14-20;364(9434):583-91. doi: 10.1016/S0140-6736(04)16850-5.

    PubMed 15313358
  • Kastrati A, Dibra A, Eberle S, Mehilli J, Suarez de Lezo J, Goy JJ, Ulm K, Schomig A. Sirolimus-eluting stents vs paclitaxel-eluting stents in patients with coronary artery disease: meta-analysis of randomized trials. JAMA. 2005 Aug 17;294(7):819-25. doi: 10.1001/jama.294.7.819.

    PubMed 16106007
  • Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, Airoldi F, Chieffo A, Montorfano M, Carlino M, Michev I, Corvaja N, Briguori C, Gerckens U, Grube E, Colombo A. Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA. 2005 May 4;293(17):2126-30. doi: 10.1001/jama.293.17.2126.

    PubMed 15870416
  • McFadden EP, Stabile E, Regar E, Cheneau E, Ong AT, Kinnaird T, Suddath WO, Weissman NJ, Torguson R, Kent KM, Pichard AD, Satler LF, Waksman R, Serruys PW. Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy. Lancet. 2004 Oct 23-29;364(9444):1519-21. doi: 10.1016/S0140-6736(04)17275-9.

    PubMed 15500897
  • Wessely R, Kastrati A, Schomig A. Late restenosis in patients receiving a polymer-coated sirolimus-eluting stent. Ann Intern Med. 2005 Sep 6;143(5):392-4. doi: 10.7326/0003-4819-143-5-200509060-00119. Epub 2005 Aug 16. No abstract available.

    PubMed 16106033
  • Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T, Mihalcsik L, Tespili M, Valsecchi O, Kolodgie FD. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation. 2004 Feb 17;109(6):701-5. doi: 10.1161/01.CIR.0000116202.41966.D4. Epub 2004 Jan 26.

    PubMed 14744976
  • Grube E, Sonoda S, Ikeno F, Honda Y, Kar S, Chan C, Gerckens U, Lansky AJ, Fitzgerald PJ. Six- and twelve-month results from first human experience using everolimus-eluting stents with bioabsorbable polymer. Circulation. 2004 May 11;109(18):2168-71. doi: 10.1161/01.CIR.0000128850.84227.FD. Epub 2004 May 3.

    PubMed 15123533
  • Hausleiter J, Kastrati A, Wessely R, Dibra A, Mehilli J, Schratzenstaller T, Graf I, Renke-Gluszko M, Behnisch B, Dirschinger J, Wintermantel E, Schomig A; investigators of the individualizable durg-eluting Stent System to Abrogate Restenosis Project. Prevention of restenosis by a novel drug-eluting stent system with a dose-adjustable, polymer-free, on-site stent coating. Eur Heart J. 2005 Aug;26(15):1475-81. doi: 10.1093/eurheartj/ehi405. Epub 2005 Jun 23.

    PubMed 15975990
  • Mehilli J, Kastrati A, Wessely R, Dibra A, Hausleiter J, Jaschke B, Dirschinger J, Schomig A; Intracoronary Stenting and Angiographic Restenosis--Test Equivalence Between 2 Drug-Eluting Stents (ISAR-TEST) Trial Investigators. Randomized trial of a nonpolymer-based rapamycin-eluting stent versus a polymer-based paclitaxel-eluting stent for the reduction of late lumen loss. Circulation. 2006 Jan 17;113(2):273-9. doi: 10.1161/CIRCULATIONAHA.105.575977. Epub 2006 Jan 3.

    PubMed 16391155
  • Wessely R, Hausleiter J, Michaelis C, Jaschke B, Vogeser M, Milz S, Behnisch B, Schratzenstaller T, Renke-Gluszko M, Stover M, Wintermantel E, Kastrati A, Schomig A. Inhibition of neointima formation by a novel drug-eluting stent system that allows for dose-adjustable, multiple, and on-site stent coating. Arterioscler Thromb Vasc Biol. 2005 Apr;25(4):748-53. doi: 10.1161/01.ATV.0000157579.52566.ee. Epub 2005 Jan 27.

    PubMed 15681298
  • Dibra A, Kastrati A, Mehilli J, Pache J, Schuhlen H, von Beckerath N, Ulm K, Wessely R, Dirschinger J, Schomig A; ISAR-DIABETES Study Investigators. Paclitaxel-eluting or sirolimus-eluting stents to prevent restenosis in diabetic patients. N Engl J Med. 2005 Aug 18;353(7):663-70. doi: 10.1056/NEJMoa044372. Epub 2005 Aug 16.

    PubMed 16105990
  • Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE; SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003 Oct 2;349(14):1315-23. doi: 10.1056/NEJMoa035071.

    PubMed 14523139

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing rapamycin-eluting Stent with permanent polymer, rapamycin-eluting stent with biodegradable polymer and polymer-free, rapamycin-eluting stent in people with Coronary Heart Disease, run by Deutsches Herzzentrum Muenchen at 2 sites in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 11 Jan 2008. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

in-stent late luminal loss (time frame: at 6 to 8-month follow-up angiogram). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00350454, which also lists 13 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Jan 2008.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in