Labour PainNCT00426725
Testing the Efficiency of a Device Meant to Relieve Labour Pain
A study testing EasyLabour in people with Labour Pain, run by ACU Medical Technologies Ltd at 1 site in Israel.
Trial summary
The suggested research is aimed to test the effectiveness of an external mechanical device to be applied and used by the parturient herself in pain relieving during labour . The research is to be performed in a controlled closely observed way, to ensure the safety of the involved parturient and newborn. Read more about this study
- Who is it for?
- Ages 18 years and older, women onlyHealthy volunteers can take part
- Conditions the study is for
- Labour Pain
- What is being tested?
- EasyLabour
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 64 participants
- Where
- 1 siteIsrael
- Study dates
- Feb 2007to Dec 2007
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- Women only
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Women with low-risk normal pregnancies.
- Healthy women, age 18 years or more.
- Single pregnancy
- At active labour, with contractions and labour pain.
Who cannot join
- Women at high risk pregnancies (with Diabetes Mellitus, Arterial Hypertension, multiple fetal pregnancy, abnormal amniotic fluid index, Intra Uterine growth restriction(IUGR), or any situation which might imply placental insufficiency)
- Caesarean sections in the past
- Any contraindication to vaginal delivery (as breech presentation or Placenta Previa).
- Any active illness, abnormal body temperature, Fatigue, etc.
- Women complaining of any pain nonrelated to labour.
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Protocol for Testing the Efficiency of a Device Meant to Relieve Labour Pain
The suggested research is aimed to test the effectiveness of an external mechanical device to be applied and used by the parturient herself in pain relieving during labour . The research is to be performed in a controlled closely observed way, to ensure the safety of the involved parturient and newborn.
Read the detailed description
Clinical Trial Design A prospective controlled study meant to scientifically test the feasibility of a device to alleviate labour pain.
- Every woman will sign an informed consent form.
- Guidance for proper and safe use of the device will be given by specially trained midwives.
- The study will be performed at the Laniado Hospital-Sanz Medical Center, Netanya, Israel.
- The study group will consist of 60 women, 30 in each group.
- Eligibility : Ages Eligible for study is 18 years and up.
Participants:
- The study group shall consists of 30 parturients at active labour, with contractions, demanding to receive analgesia. The device will be given, with guidance from a pre-trained midwife and under professional supervision. This study group will include also women choosing to continue using it till the application of epidural analgesia.
- The control group shall consists of 30 parturients at active labour, with contractions, choosing to receive epidural analgesia.
Inclusion criteria:
- Women with low-risk normal pregnancies.
- Healthy women, age 18 years or more.
- Single pregnancy
- At active labour, with contractions and labour pain.
Exclusion criteria:
- Women at high risk pregnancies (with Diabetes Mellitus, Arterial Hypertension, multiple fetal pregnancy, abnormal amniotic fluid index, Intra Uterine growth restriction(IUGR), or any situation which might imply placental insufficiency)
- Caesarean sections in the past
- Any contraindication to vaginal delivery (as breech presentation or Placenta Previa).
- Any active illness, abnormal body temperature, Fatigue, etc.
- Women complaining of any pain nonrelated to labour.
Criteria for taking out of the study:
Upon parturient's demand. Analgesia will be given upon parturient demand.
Method:
Parturients arriving at the delivery room and fitting the criteria will randomly divided into two groups: the study group, which will use the device, and the control group.
Intensity of pain will be measured in five different stages:
- Before they put on the device.
- Five minutes after starting to use the device.
- After 30 minutes of use.
- The device will be turned off for the duration of three consecutive contractions after which pain intensity will be measured.
- The device will be turned on and pain intensity will be measured after 5 minutes of renewed use.
- Pain intensity will be measured and defined by the participants using the Mosby Pain Rating Scale (see attached document).
- The device will be attached to participants with uterine contractions with a frequency of at least 3 contractions every 10 minutes and cervical dilatation of at least 2 cm.
- Both groups will be divided according to 3 age subgroups: 18 to 30, 31 to 40, and 41 to 45.
- A further division will be according to BMI: below BMI 20, 20 to 25, and above a BMI of 25.
In both groups 6 indexes will be measured:
- Comparison of pain intensity between subjects of both groups.
- Stage of application of analgesia, epidural or other.
- Length of second stage of birth.
- Rate of instrumental deliveries.
- Rate of Caesarean Sections due to non-advancement progressive labour, arrest of cervical dilatation, or arrest of fetal head descent .
Rate of fetal non reassuring monitor, like fetal deceleration or low variability.
Study length:
The study may take around one year, or till enough cases are collected in both groups.
Definition of success:
Success will be defined as proof of labour pain relief achievement, measured as a difference between the study and control groups, among participants in the study group, according to statistical criteria as are customary in similar studies. Exceptional success will be considered if statistical proof could be observed that using the device shortens delivery length of time, or, that using of the device diminishes the usage of epidural analgesia.
- Conditions
- Labour Pain
- Being tested
- EasyLabour
- Keywords
- labor, pain, relief, labour, device
- Medical subject headings
- Labor Pain, Pain
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
EasyLabourDevice
According to the trial protocol
| Study group | Role | What they receive |
|---|---|---|
| A | Experimental | This group uses the EasyLabour device according to the protocol Receives: Device: EasyLabour |
| Control | No intervention | Not described Receives: Device: EasyLabour |
What is being measured
The primary outcome is the main question the study is designed to answer.
Mosby Pain Rating Scale (VAS)
Measured: 6 Months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted25 Jan 2007 (estimated)
- Study startFeb 2007
- Primary completionDec 2007
- Study completionDec 2007
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Labour PainStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Supportive care
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 64 participants (actual)
Sponsor and investigators
- Lead sponsor
- ACU Medical Technologies Ltd
- Sponsor type
- Industry (pharma, biotech, devices)
- Investigators
- Shay Kevorkian, MD, Principal investigator, Laniado Sanz Hospital - Netanya - Israel
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT00426725
- Sponsor's protocol ID
- ACUMT-07-KS-3811-CTIL
- Other IDs
- HTA3811
- Status last verified
- Jul 2008
- First submitted
- 23 Jan 2007
- Last updated
- 1 Aug 2008
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 1 Aug 2008. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Protocol for Testing the Efficiency of a Device Meant to Relieve Labour Pain
- ClinicalTrials.gov ID
- NCT00426725
- Acronym / sponsor ID
- ACUMT-07-KS-3811-CTIL
- Conditions
- Labour Pain
- Keywords
- labor, pain, relief, labour, device
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 64 participants (actual)
- Lead sponsor
- ACU Medical Technologies LtdIndustry (pharma, biotech, devices)
- Study start
- Feb 2007
- Primary completion
- Dec 2007 (actual)
- Study completion
- Dec 2007 (actual)
- First posted
- 25 Jan 2007 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The suggested research is aimed to test the effectiveness of an external mechanical device to be applied and used by the parturient herself in pain relieving during labour . The research is to be performed in a controlled closely observed way, to ensure the safety of the involved parturient and newborn.
Detailed description
Clinical Trial Design A prospective controlled study meant to scientifically test the feasibility of a device to alleviate labour pain.
- Every woman will sign an informed consent form.
- Guidance for proper and safe use of the device will be given by specially trained midwives.
- The study will be performed at the Laniado Hospital-Sanz Medical Center, Netanya, Israel.
- The study group will consist of 60 women, 30 in each group.
- Eligibility : Ages Eligible for study is 18 years and up.
Participants:
- The study group shall consists of 30 parturients at active labour, with contractions, demanding to receive analgesia. The device will be given, with guidance from a pre-trained midwife and under professional supervision. This study group will include also women choosing to continue using it till the application of epidural analgesia.
- The control group shall consists of 30 parturients at active labour, with contractions, choosing to receive epidural analgesia.
Inclusion criteria:
- Women with low-risk normal pregnancies.
- Healthy women, age 18 years or more.
- Single pregnancy
- At active labour, with contractions and labour pain.
Exclusion criteria:
- Women at high risk pregnancies (with Diabetes Mellitus, Arterial Hypertension, multiple fetal pregnancy, abnormal amniotic fluid index, Intra Uterine growth restriction(IUGR), or any situation which might imply placental insufficiency)
- Caesarean sections in the past
- Any contraindication to vaginal delivery (as breech presentation or Placenta Previa).
- Any active illness, abnormal body temperature, Fatigue, etc.
- Women complaining of any pain nonrelated to labour.
Criteria for taking out of the study:
Upon parturient's demand. Analgesia will be given upon parturient demand.
Method:
Parturients arriving at the delivery room and fitting the criteria will randomly divided into two groups: the study group, which will use the device, and the control group.
Intensity of pain will be measured in five different stages:
- Before they put on the device.
- Five minutes after starting to use the device.
- After 30 minutes of use.
- The device will be turned off for the duration of three consecutive contractions after which pain intensity will be measured.
- The device will be turned on and pain intensity will be measured after 5 minutes of renewed use.
- Pain intensity will be measured and defined by the participants using the Mosby Pain Rating Scale (see attached document).
- The device will be attached to participants with uterine contractions with a frequency of at least 3 contractions every 10 minutes and cervical dilatation of at least 2 cm.
- Both groups will be divided according to 3 age subgroups: 18 to 30, 31 to 40, and 41 to 45.
- A further division will be according to BMI: below BMI 20, 20 to 25, and above a BMI of 25.
In both groups 6 indexes will be measured:
- Comparison of pain intensity between subjects of both groups.
- Stage of application of analgesia, epidural or other.
- Length of second stage of birth.
- Rate of instrumental deliveries.
- Rate of Caesarean Sections due to non-advancement progressive labour, arrest of cervical dilatation, or arrest of fetal head descent .
Rate of fetal non reassuring monitor, like fetal deceleration or low variability.
Study length:
The study may take around one year, or till enough cases are collected in both groups.
Definition of success:
Success will be defined as proof of labour pain relief achievement, measured as a difference between the study and control groups, among participants in the study group, according to statistical criteria as are customary in similar studies. Exceptional success will be considered if statistical proof could be observed that using the device shortens delivery length of time, or, that using of the device diminishes the usage of epidural analgesia.
Study design
- Primary purpose
- Supportive care
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| A | Experimental | Device: EasyLabourThis group uses the EasyLabour device according to the protocol |
| Control | No intervention | Device: EasyLabour |
Who may qualify
- Ages
- 18 years and older
- Sex
- Female only
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Women with low-risk normal pregnancies.
- Healthy women, age 18 years or more.
- Single pregnancy
- At active labour, with contractions and labour pain.
Key exclusion criteria (5 listed)
- Women at high risk pregnancies (with Diabetes Mellitus, Arterial Hypertension, multiple fetal pregnancy, abnormal amniotic fluid index, Intra Uterine growth restriction(IUGR), or any situation which might imply placental insufficiency)
- Caesarean sections in the past
- Any contraindication to vaginal delivery (as breech presentation or Placenta Previa).
- Any active illness, abnormal body temperature, Fatigue, etc.
- Women complaining of any pain nonrelated to labour.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| EasyLabourAccording to the trial protocol | Device | A, Control |
Primary outcome
Mosby Pain Rating Scale (VAS)
Time frame: 6 Months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 1 Aug 2008.
Related trials for Labour Pain
Recruiting
The Effect Of Partner-Assısted Rebozo Technıque On Labor Paın And Satısfactıon In Prımary Pregnant Women
Labor Pains
RecruitingPhase 4
Analgesic Efficacy and Obstetric Effects of Tramadol, Paracetamol and Placebo in Active Labor
Labor Pain
Not yet recruiting
The Effect of Music Play and Stress Ball Application on Placental Separation Time, Episious Pain and Breastfeeding Success
Primiparity (First-Time Mothers), Breastfeeding
Recruiting
Pain Neuroscience-Based Education for Labor Pain in Pregnant Women
Labor Pain and Anxiety
Not yet recruiting
The 90% Effective Initial Volume for Labor Analgesia Under Double Dural Puncture Epidural Technique
Labor Pain
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Shay Kevorkian, MD principal investigator
Laniado Sanz Hospital - Netanya - Israel
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing EasyLabour in people with Labour Pain, run by ACU Medical Technologies Ltd at 1 site in Israel.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 1 Aug 2008. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Israel. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Mosby Pain Rating Scale (VAS) (time frame: 6 Months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Aug 2008.