Clinical Study of Thoracic Aortic Aneurysm Exclusion

A study testing Valiant Endoluminal Stent-Graft Stent-Graft Balloon Catheter in people with Thoracic Aortic Aneurysm, run by Arizona Heart Institute at 1 site in United States.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The Valiant stent-graft system is a flexible, implantable vascular stent-graft endoluminal device preloaded in a delivery system that is used to exclude thoracic aortic lesions (thoracic aneurysms, thoracic dissections, penetrating ulcers, traumatic transections and both traumatic and degenerative pseudoaneurysms. Read more about this study

Who is it for?
Ages 18 to 90 years
Conditions the study is for
Thoracic Aortic Aneurysm
What is being tested?
Valiant Endoluminal Stent-Graft Stent-Graft Balloon Catheter
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
1 siteUnited States
Study dates
Oct 2002to Sep 2012
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Subject is ≥ 18 years of age.
  • Subject is not pregnant or lactating. Females of child-bearing potential must practice a reliable method of contraception.
  • Subject is diagnosed with one of the following conditions of the descending thoracic aorta. All conditions must be verified by diagnostic imaging [ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI) or angiography].
  • A true (i.e., atherosclerotic) supraceliac aneurysm (fusiform or saccular type) with or without a co-existing aortic dissection or penetrating aortic ulcer;
  • Aortic dissection of DeBakey Type I or II (Stanford A, proximal) in the absence of an aneurysm; or
  • Penetrating aortic ulcer in the absence of an aneurysm; or
Show all 15Show fewer
  • Traumatic transection; or
  • Pseudoaneurysm - traumatic or degenerative (i.e., one that does not involve all layers of the vessel and is not atherosclerotic in origin.
  • Subject's anatomy is suitable for placement of the TALENT endoluminal stent-graft, with a distinct proximal aneurysm neck of 10 mm or more in length and a distal aneurysm neck of at least 10 mm.
  • Subject has a TAA that is dilated to ≥ 5 cm in diameter, ≥ 1.5 times the diameter of the adjacent native/non-aneurysmal aorta, or is symptomatic.
  • Subject has a proximal and distal aortic neck diameter ≥ 18 mm and ≤ 42 mm.
  • Subject has an arterial access site, either peripherally or via infrarenal abdominal aorta that is adequate for introduction of the stent-graft delivery system.
  • Subject has signed the informed consent.
  • Subject will be available for the periodic follow-up (surveillance) after the procedure.
  • Aortic.

Who cannot join

  • Subject has TAA with less than 10 mm proximal fixation length.
  • Subject has an aneurysm that would require exclusion by the stent-graft of the segment of the aorta that gives rise to dominant spinal cord/intercostal arteries.
  • Subject has a lesion that prevents delivery or expansion of the device.
  • Subject has systemic infection, or is suspected of having systemic infection.
  • Subject has a known mycotic aneurysm.
  • Subject is not available or is not willing to come back for periodic follow-up (surveillance) after the procedure.

Trial locations and contacts

1 site in 1 country.

United States1 site, 1 recruiting
  • Arizona Heart Institute

    Phoenix, Arizona, 85006

    Edward B Diethrich, M.D.

    Julio Rodriguez-Lopez, M.D.

    Recruiting

Other trials in United States

About this study

Official title: Clinical Study of Thoracic Aortic Aneurysm Exclusion Using the VALIANT System

The Valiant stent-graft system is a flexible, implantable vascular stent-graft endoluminal device preloaded in a delivery system that is used to exclude thoracic aortic lesions (thoracic aneurysms, thoracic dissections, penetrating ulcers, traumatic transections and both traumatic and degenerative pseudoaneurysms.

Read the detailed description

A vascular aneurysm is a permanent, localized dilatation of a blood vessel at least 1 1/2 to 2 times the normal vessel diameter. The aorta is the most frequent site for aneurysms, with approximately 10% of aortic aneurysms located above the renal arteries in the thoracic segment. Thoracic aortic aneurysms (TAAs) are less common than abdominal aorta, however, detection of TAAs is increasing, perhaps due to an aging population, increased diagnostic capability or an increase in prevalence.

Untreated thoracic aneurysms can be life-threatening. As many as 78% of untreated patients with TAA die within 5 years after diagnosis, most often from rupture of the aneurysm. Conventional surgical treatment, either tube graft placement or patch aortoplasty, is a high risk surgical procedure. Repair of the thoracic descending aorta is performed with a thoracotomy and cross-clamping of the aorta, with or without a shunt by-pass to maintain distal perfusion.

As an alternative to conventional surgery, a less invasive endovascular procedure has been developed that may be used to treat certain aneurysms. A collapsed stent-graft, a metal stent coupled with a fabric graft, is introduced into the vasculature, advanced to the size of the aneurysm, and deployed to span the aneurysm. The device creates a new aortic lumen, excluding the aneurysm sac from blood flow while maintaining flow within the stent-graft. This less invasive technique is designed to prevent or decrease the need for open surgery, to reduce the need for blood transfusion, to decrease the use of anesthetics and other drugs, and to speed recovery time. A reduction in intensive care and total hospital stay should result, leading to an increase quality of life following the procedure and a reduction in cost.

The primary objective of this investigational plan is to determine the safety of the Valiant endoluminal device when used to exclude thoracic lesions: true descending thoracic aortic aneurysms, dissections, penetrating ulcers, traumatic transections and traumatic and degenerative pseudoaneurysms from blood flow in high risk and low risk patients who are candidates for endoluminal repair.

Patients should be heparinized during the implant procedure (recommended activated clotting time is 200-300 seconds). During implantation of the Valiant endoluminal stent-graft, the pre-implant angiogram and CT scan are used together with (on-the-table) intravascular ultrasound (IVUS), digital subtraction angiography (DAS), roadmapping, and angiography for proper implant positioning. The Valiant endoluminal stent-graft endoprosthesis is inserted by delivery catheter and introducer sheath via a surgical cutdown (e.g., external iliac artery, femoral artery, common iliac artery conduit, etc.) approach. The introducer sheath and delivery catheter containing the stent-graft is inserted over a guidewire and advanced into the aorta and above the aneurysm. With the delivery catheter in the correct position, the introducer sheath is then withdrawn further until the stent-graft is completely deployed. A separate stent-graft balloon catheter system is provided with the device and may be used along the full length of the implanted device to model the springs against the vessel wall and to unravel possible wrinkles in the graft fabric. After deployment of the stent-graft, angiography is performed to verify implant position and to check for the presence of endoleaks.

Subjects will undergo an evaluation of the Valiant endoluminal stent-graft to determine the safety and efficacy of the device as indicated by the adverse event rate, and to determine the risk factors that are most predictive of a successful outcome when used to exclude thoracic aortic aneurysms that require suprarenal fixation in high risk and low risk patients. Follow-up will be completed at 1, 6, 12, 24, 36, 48, and 60 months. Subject evaluation at 1 month will include a Complete Physical Exam, Labs (BUN and Creatinine), and a Thoracic Spiral CT with and without IV contrast 2.5 mm. Subject evaluation at 6, 12, 24, 36, 48, and 60 months will include a Complete Physical Exam, Chest X-ray (AP, Lateral), Labs (BUN and Creatinine), and a Thoracic Spiral CT with and without IV contrast 2.5 mm.

Being tested
Valiant Endoluminal Stent-Graft Stent-Graft Balloon Catheter
Medical subject headings
Aortic Aneurysm, Thoracic

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Valiant Endoluminal Stent-Graft Stent-Graft Balloon CatheterDevice

    VALIANT stent-graft endoprosthesis is inserted by the Xcelerant Delivery System via a surgical cutdown (e.g., external iliac artery, femoral artery, common iliac artery conduit, etc.) approach. The insertion method depends on each patient's anatomy and is determined by the Clinical Investigator.

Study groups in NCT00549315
Study groupRoleWhat they receive
1ExperimentalNot described
Receives: Device: Valiant Endoluminal Stent-Graft Stent-Graft Balloon Catheter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Determine the proportion in whom successful implantation is achieved, as indicated by aneurysm exclusion and graft patency.

    Measured: At implant, time of discharge, and 1, 6, and 12 months.

Secondary outcomes (2)
  1. Determine the proportion of patients who experience adverse events.

    Measured: During and after implantation.

  2. Determine the proportion of patients who experience comorbidities and overall mortality rates.

    Measured: During and after implantation.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted25 Oct 2007 (estimated)
  2. Study startOct 2002
  3. Primary completionSep 2012 (estimated)
  4. Study completionSep 2012 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
60 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00549315
Sponsor's protocol ID
G020150
Acronym
Valiant
Status last verified
May 2009
First submitted
24 Oct 2007
Last updated
15 May 2009
Results posted
No
Data monitoring committee
No

Publications

  • Coselli JS, S Buket, and ES Crawford. 1996. Thoracic aortic aneurysms. In: Haimovicis Vascular Surgery, 4th ed, H Haimovici, E Ascer, LH Hollier, DE Strandness, and JB Towne, eds. Blackwell Science, chapter 57.

  • Coselli JS and SA LeMaire. 1995. Diseases of the thoracic aorta. In: Current Diagnosis and Treatment in Vascular Surgery, 1st ed, RH Dean, JST Yao, and DC Brewster, eds. Appleton & Lange, Norwalk, CT, chapter 11.

  • Dake MD, Miller DC, Semba CP, Mitchell RS, Walker PJ, Liddell RP. Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med. 1994 Dec 29;331(26):1729-34. doi: 10.1056/NEJM199412293312601.

    PubMed 7984192
  • Mitchell RS, Miller DC, Dake MD. Stent-graft repair of thoracic aortic aneurysms. Semin Vasc Surg. 1997 Dec;10(4):257-71.

    PubMed 9431597
  • Moreno-Cabral CE, Miller DC, Mitchell RS, Stinson EB, Oyer PE, Jamieson SW, Shumway NE. Degenerative and atherosclerotic aneurysms of the thoracic aorta. Determinants of early and late surgical outcome. J Thorac Cardiovasc Surg. 1984 Dec;88(6):1020-32.

    PubMed 6503314
  • Najafi H. Thoracic aortic aneurysm: evaluation and surgical management. Compr Ther. 1994;20(5):282-8. No abstract available.

    PubMed 8045085
  • Pressler V, McNamara JJ. Thoracic aortic aneurysm: natural history and treatment. J Thorac Cardiovasc Surg. 1980 Apr;79(4):489-98. No abstract available.

    PubMed 7359927
  • Skeens JL and MD Dake. 1997. Thoracic aortic aneurysm stent-grafts. Eighth Complex Peripheral Angioplasty Course. Paris, May 20-23, 1997, pp. 289-295.

  • Nienaber CA, Fattori R, Lund G, Dieckmann C, Wolf W, von Kodolitsch Y, Nicolas V, Pierangeli A. Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. N Engl J Med. 1999 May 20;340(20):1539-45. doi: 10.1056/NEJM199905203402003.

    PubMed 10332015
  • White RA, Donayre CE, Walot I, Lippmann M, Woody J, Lee J, Kim N, Kopchok GE, Fogarty TJ. Endovascular exclusion of descending thoracic aortic aneurysms and chronic dissections: Initial clinical results with the AneuRx device. J Vasc Surg. 2001 May;33(5):927-34. doi: 10.1067/mva.2001.114998.

    PubMed 11331830

Questions about this trial

What is this clinical trial studying?

A study testing Valiant Endoluminal Stent-Graft Stent-Graft Balloon Catheter in people with Thoracic Aortic Aneurysm, run by Arizona Heart Institute at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 15 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 15 May 2009. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Russell Williams (602-266-2200 ext. 3604, rwilliams@azheart.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Determine the proportion in whom successful implantation is achieved, as indicated by aneurysm exclusion and graft patency. (time frame: At implant, time of discharge, and 1, 6, and 12 months.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00549315, which also lists 10 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 May 2009.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in