Diabetes Mellitus, Type 1SWITCHNCT00598663

SWITCH - Sensing With Insulin Pump Therapy to Control HbA1c

A study testing insulin pump with continuous glucose sensing (Paradigm Real-Time Insulin Pump System) and insulin pump and blinded continuous glucose sensing (Paradigm Real-Time insulin pump) in people with Diabetes Mellitus, Type 1, run by Medtronic MiniMed, Inc. at 8 sites in 7 countries.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The primary objective of this study is to evaluate whether the patients with Type 1 diabetes mellitus in sub-optimal glycemic control can achieve better glycemic control by using the Medtronic MiniMed Paradigm® REAL-Time Pump System with continuous glucose monitoring versus the Medtronic MiniMed Paradigm® REAL-Time… Read more about this study

Who is it for?
Ages 6 to 70 yearsHealthy volunteers can take part
Conditions the study is for
Diabetes Mellitus, Type 1
What is being tested?
insulin pump with continuous glucose sensing (Paradigm Real-Time Insulin Pump System) and insulin pump and blinded continuous glucose sensing (Paradigm Real-Time insulin pump)
Could I receive a placebo?
No, everyone receives an active treatment
How many people
153 participants
Where
8 sitesin 7 countries
Study dates
Jan 2008to Jul 2010
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 6 to 70 years
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • Type 1 diabetes mellitus diagnosed for at least 12 months prior to signature of informed consent,
  • Sub-optimal glycemic control (7.5%<HbA1c<9.5%).
  • Patient treated by continuous subcutaneous insulin infusion (CSII) for at least 6 months prior signature of informed consent.
  • Patient treated within the practice of the investigator's center at least 6 months prior signature of informed consent.
  • Patient has no preliminary experience with the sensor function of the Paradigm REAL-Time or the Guardian® REAL-Time for the 4 months prior signature of informed consent.

Who cannot join

  • Existing pregnancy or intention to conceive (as assessed by investigator).
  • Hearing or vision impairment so that glucose display and alarms cannot be recognized.
  • Three or more incidents in the last 12 months of severe hypoglycaemia with documented Blood Glucose below 50mg/dL (if possible), resulting in unconsciousness, hospitalisation or third party assistance, where recovery follows treatment with glucose or glucagon or similar.
  • History of hypoglycemic unawareness as assessed by the investigator.
  • Alcohol or drug abuse, other than nicotine.
  • Documented cutaneous allergy or disease (allergy to sensor or components of the sensor, psoriasis, staphylococcus, exanthema etc.).
Show all 11Show fewer
  • Any documented concomitant chronic disease known to affect diabetes control (e.g. altered renal function, active cancer undergoing treatment, Crohn's disease, ulcerative colitis, Mb Addison disease) or any concomitant pharmacological treatment that might modify glycemic values (e.g chronic corticosteroid therapy), eating disorders and morbid obesity (defined as adults : Body Mass Index >35 and children Body Mass Index > 2 standard deviations. for age) as assessed by the investigator.
  • Any other medical, social or psychological condition that, in the investigator's opinion, makes the patient unable to comply with the study protocol and all study procedures.
  • For pediatric subjects: does not have a reliable support person.
  • Plans to travel for extended periods (3+ weeks) where the devices cannot be supplied or replaced and/or medical support is limited (eg. exotic countries, remote places).
  • Participation in another clinical study, on-going or completed less than 3 months prior to signature of Patient Informed Consent.

Trial locations and contacts

8 sites in 7 countries.

8 sites in 7 countries

Denmark2 sites
  • Steno Diabetes Center

    Copenhagen

  • Glostrup Hospital

    Glostrup Municipality

Other trials in Denmark

Austria1 site
  • Hospital Hietzing

    Vienna

Other trials in Austria

Italy1 site
  • Clinica Pediatrica, Policlinico Umberto I

    Rome

Other trials in Italy

Luxembourg1 site
  • Center Hospitalier de Luxembourg

    Luxembourg

Other trials in Luxembourg

Netherlands1 site
  • Groene Hart Ziekenhuis

    Gouda

Other trials in Netherlands

Slovenia1 site
  • University Children's Hospital

    Ljubljana

Other trials in Slovenia

Spain1 site
  • Hospital Clinic i Universitari

    Barcelona

Other trials in Spain

About this study

Official title: Randomized, Cross Over, Controlled, Multi-centric Study to Assess Whether Type 1 Diabetic Patients in Sub-optimal Glycemic Control Can Improve Using the Continuous Glucose Values of the MiniMed Paradigm REAL-Time Insulin Pump System Versus the MiniMed Paradigm Insulin Pump

The primary objective of this study is to evaluate whether the patients with Type 1 diabetes mellitus in sub-optimal glycemic control can achieve better glycemic control by using the Medtronic MiniMed Paradigm® REAL-Time Pump System with continuous glucose monitoring versus the Medtronic MiniMed Paradigm® REAL-Time Pump alone with Self Monitoring Blood Glucose (SMBG).Our null hypothesis is there is a 0% reduction in HbA1c from baseline compared to control group, after 6 months of treatment.

Being tested
insulin pump with continuous glucose sensing (Paradigm Real-Time Insulin Pump System), insulin pump and blinded continuous glucose sensing (Paradigm Real-Time insulin pump)
Keywords
Type 1 diabetes
Medical subject headings
Diabetes Mellitus, Type 1

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • insulin pump with continuous glucose sensing (Paradigm Real-Time Insulin Pump System)Device

    Also called Paradigm Real-Time Insulin Pump System, Medtronic MMT-522 or MMT-722 + MMT7707WW

    6 months of pump plus continuous glucose sensing in conjunction to SMBG

  • insulin pump and blinded continuous glucose sensing (Paradigm Real-Time insulin pump)Device

    Also called Paradigm Real-Time insulin pump, Guardian Real-Time clinical, MMT-522 or MMT-722 + MMT7707WW + CSS7100

    insulin pump with smbg to be worn for 6 months. 15 days in each 6 week period blinded continuous glucose sensing will be conducted.

Study groups in NCT00598663
Study groupRoleWhat they receive
Off/OnExperimental6 month-Period Off: Continuous Subcutaneous Insulin Infusion (CSII) and Self Monitoring Blood Glucose [Device: Paradigm® Real-Time pump with Sensor Off feature] 4 month wash out period 6 month-Period On: Continuous Subcutaneous Insulin Infusion (CSII) + personal continuous glucose monitoring (personal CGM) [Device: Paradigm® Real-Time pump with Sensor On feature continuously]
Receives: Device: insulin pump with continuous glucose sensing (Paradigm Real-Time Insulin Pump System)
On/OffExperimental6 month-Period On: Continuous Subcutaneous Insulin Infusion (CSII) + personal continuous glucose monitoring (personal CGM) [Device: Paradigm® Real-Time pump with Sensor On feature continuously] 4 month wash out period 6 month-Period Off: Continuous Subcutaneous Insulin Infusion (CSII) and Self Monitoring Blood Glucose [Device: Paradigm® Real-Time pump with Sensor Off feature]
Receives: Device: insulin pump and blinded continuous glucose sensing (Paradigm Real-Time insulin pump)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. HbA1c at 6 Month

    The end of period difference in HbA1c after 6 months of treatment

    Measured: 6 months

Secondary outcomes (6)
  1. Glycemic Variability

    24 h SD of glucose values (mg/dl)

    Measured: 6 months

  2. Number of Severe Hypoglycemia Events

    Measured: 6 months

  3. Daily Min Spent in Euglycaemia (3.9-10.0 mmol/l)

    Measured: 6 months

  4. Postprandial Glycaemia

    Breakfast Postprandial glycaemia

    Measured: 6 months

  5. Pediatric Quality of Life Inventory (Vers 4.0; PedsQL)

    This questionnaire is a validated assessment of health-related quality of life in children developed by J.W. Varni, (1998).

    Scores are transformed on a scale from 0 to 100. higher values represent a better outcome

    Measured: 6 months

  6. Diabetic Ketoacidosis Events

    A diabetic ketoacidosis event (DKE) is defined as a hyperglycemia (blood glucose >250 mg/dL) with either low serum bicarbonate (<15 mEq/L) and/or low pH (<7.3) and either ketonemia or ketonuria and requiring treatment within a health-care facility.

    Measured: 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Jan 2008 (estimated)
  2. Study startJan 2008
  3. Primary completionJul 2010
  4. Study completionJul 2010

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
153 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00598663
Sponsor's protocol ID
EUR03
Other IDs
ISRCTN09806152
Acronym
SWITCH
Status last verified
Aug 2019
First submitted
5 Dec 2007
Last updated
16 Sep 2019
Data monitoring committee
No

Publications

  • Battelino T, Conget I, Olsen B, Schutz-Fuhrmann I, Hommel E, Hoogma R, Schierloh U, Sulli N, Bolinder J; SWITCH Study Group. The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trial. Diabetologia. 2012 Dec;55(12):3155-62. doi: 10.1007/s00125-012-2708-9. Epub 2012 Sep 11.

    PubMed 22965294

Questions about this trial

What is this clinical trial studying?

A study testing insulin pump with continuous glucose sensing (Paradigm Real-Time Insulin Pump System) and insulin pump and blinded continuous glucose sensing (Paradigm Real-Time insulin pump) in people with Diabetes Mellitus, Type 1, run by Medtronic MiniMed, Inc. at 8 sites in 7 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 16 Sep 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 8 sites in Denmark, Austria, Italy, Luxembourg, Netherlands and 2 more countries. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 16 Sep 2019). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

HbA1c at 6 Month (time frame: 6 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00598663, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Sep 2019; AzTrials last refreshed its copy on 31 Oct 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in