Sudden Cardiac DeathPhase 4NCT00626093

'Effect of CRT on Defibrillation Threshold Estimates' Study

A Phase 4 study testing Cardiac Resynchronization Therapy - Defibrillator (CRT-D) in people with Sudden Cardiac Death, run by Abbott Medical Devices at 2 sites in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this prospective study is to evaluate the effect of cardiac resynchronization therapy (CRT) on the defibrillation threshold (DFT) estimates in cardiac resynchronization therapy defibrillators (CRT-D) patients. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Sudden Cardiac Death
What is being tested?
Cardiac Resynchronization Therapy - Defibrillator (CRT-D)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
77 participants
Where
2 sitesUnited States
Study dates
Jan 2008to Apr 2010
Phase
Phase 4
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patient meets standard indications for a Cardiac Resynchronization Therapy - Defibrillator (CRT-D).
  • Patient will be implanted with an FDA approved St Jude Medical (SJM) Cardiac Resynchronization Therapy - Defibrillator (CRT-D) and compatible defibrillation lead system.
  • Patient is able to tolerate defibrillation threshold (DFT) testing.
  • Patient is geographically stable and willing to comply with the required follow-up schedule.
  • Patient has a life expectancy of greater than 6 months from the time of implant.
  • Patient has stable heart failure (HF) medications at least one month prior to enrollment.

Who cannot join

  • Inability to successfully implant an intravascular lead Cardiac Resynchronization Therapy - Defibrillator (CRT-D) device. (i.e. exclude epicardial leads).
  • Patient is getting his Cardiac Resynchronization Therapy - Defibrillator (CRT-D) device replaced.
  • Inability to successfully obtain the defibrillation threshold (DFT) at implant.
  • Currently participating in a clinical trial that includes an active treatment arm or another data collection registry.
  • Recent (within 24 hours) administration of Nesiritide™.
  • Patient is on amiodarone (other antiarrhythmic agents known to affect defibrillation thresholds - DFTs) at the time of enrollment.
  • Patient is pregnant.
  • Patient is less than 18 years old.

Trial locations and contacts

2 sites in 1 country.

United States2 sites
  • Penrose Hospital

    Colorado Springs, Colorado, 80907

  • Pacific Heart Institute

    Santa Monica, California, 90404

Other trials in United States

About this study

Official title: Effect of Cardiac Resynchronization Therapy (CRT) on the Defibrillation Threshold (DFT) Estimates

The purpose of this prospective study is to evaluate the effect of cardiac resynchronization therapy (CRT) on the defibrillation threshold (DFT) estimates in cardiac resynchronization therapy defibrillators (CRT-D) patients. The hypothesis of the study is that defibrillation threshold (DFT) will decrease with 6 months of cardiac resynchronization therapy (CRT).

Read the detailed description

Cardiac Resynchronization Therapy (CRT) has emerged as a promising therapeutic addition in patients with drug refractory heart failure (HF). Along with providing relief of symptoms of HF, cardiac resynchronization therapy defibrillators (CRT-D) are used for the prevention of sudden cardiac death (SCD). Although there are concerns that the defibrillation threshold (DFT) estimates are elevated in the heart failure (HF) patient population due to lower LV ejection fraction (EF) and left ventricular (LV) dysfunction, there is paucity of data available to evaluate this theory.

Recently, two different studies in a retrospective manner evaluated the energy requirements in patients receiving cardiac resynchronization therapy defibrillators (CRT-D). Burke et al analyzed DFTs in 50 patients each implanted with a cardiac resynchronization therapy defibrillators (CRT-D) device and an implantable cardioverter defibrillator (ICD). Although the ejection fraction (EF) in cardiac resynchronization therapy defibrillators (CRT- D) group was lower than the implantable cardioverter defibrillator (ICD) group, the mean defibrillation thresholds (DFTs) between the two groups were not significantly different (10.2 ± 6.1 J for the cardiac resynchronization therapy (CRT) group vs. 9.5 ± 5.0 J for the control group)14. In the ASSURE study, Doshi et al. showed that patients receiving cardiac resynchronization therapy defibrillators (CRT-D) devices do not have higher energy requirements when compared to patients receiving modern single or dual chamber implantable cardioverter defibrillators (ICDs). Although, there was a trend toward higher energy requirements found among patients with higher degrees of heart failure.

Major cardiac resynchronization therapy (CRT) trials have showed that cardiac resynchronization therapy (CRT) therapy has positive effects on ejection fraction (EF) and the heart failure (HF) condition of the patient over time. But, there is no study that has evaluated the defibrillation thresholds (DFTs) in the heart failure (HF) patients over time of receiving cardiac resynchronization therapy (CRT). This information will help the clinicians decide if they need to perform more invasive procedures during device implant to lower DFTs in patients who do not meet the defibrillation safety margin or they should just wait over time for the CRT to reduce the defibrillation threshold (DFT). Also, there is no published data about the stability of defibrillation thresholds (DFTs) in heart failure (HF) patients over time. The results from this study will also help to clarify whether it is safe to never test the defibrillation thresholds (DFTs) post-implant in this patient population.

Being tested
Cardiac Resynchronization Therapy - Defibrillator (CRT-D)
Medical subject headings
Death, Sudden, Cardiac

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Cardiac Resynchronization Therapy - Defibrillator (CRT-D)Device

    Also called Epic HF,Atlas+ HF,Epic II HF,Atlas II HF,Promote CRT-D

    • Patients in the study who receive Cardiac Resynchronization Therapy - Defibrillator (CRT-D) are indicated for Cardiac Resynchronization Therapy (CRT).
    • Patient undergoes Defibrillation threshold (DFT) testing at implant and at 6 months. Defibrillation threshold (DFT) testing will include 3 ventricular fibrillation (VF) inductions.
Study groups in NCT00626093
Study groupRoleWhat they receive
Cardiac Resynchronization Therapy - Defibrillator (CRT-D)OtherPatients in the study who received a Cardiac Resynchronization Therapy - Defibrillator (CRT-D) are indicated for it. It's a single arm study in which patients underwent defibrillation threshold (DFT) testing at implant and 6 months.
Receives: Device: Cardiac Resynchronization Therapy - Defibrillator (CRT-D)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Defibrillation Threshold Difference Obtained in Volts (V) Between Implant and 6 Months

    All patients underwent defibrillation threshold testing at cardiac resynchronization therapy-defibrillator (CRT-D) implant and then at 6 months. The outcome measure is the difference in DFT (defibrillation threshold) in volts between implant and 6 months.

    Measured: Baseline and 6 months

Secondary outcomes (1)
  1. Defibrillation Threshold Difference Obtained in Joules (J)

    Measured: Baseline and 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Feb 2008 (estimated)
  2. Study startJan 2008
  3. Primary completionApr 2010
  4. Study completionApr 2010

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
77 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00626093
Sponsor's protocol ID
CRD 388
Status last verified
Feb 2019
First submitted
7 Feb 2008
Last updated
5 Feb 2019
Data monitoring committee
No

Publications

  • Gold MR, Hedayati A, Alaeddini J, Payne JP, Bailin S, Sturdivant JJ, Pradhan S, Oza AL. Temporal stability of defibrillation thresholds with cardiac resynchronization therapy. Heart Rhythm. 2011 Jul;8(7):1008-13. doi: 10.1016/j.hrthm.2011.02.006. Epub 2011 Feb 9.

    PubMed 21315841

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing Cardiac Resynchronization Therapy - Defibrillator (CRT-D) in people with Sudden Cardiac Death, run by Abbott Medical Devices at 2 sites in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 5 Feb 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Yes. Results are posted in the registry (first posted 21 Jan 2013). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Defibrillation Threshold Difference Obtained in Volts (V) Between Implant and 6 Months (time frame: Baseline and 6 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00626093, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Feb 2019.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in