BronchiectasisNCT00656721

Respiratory Mechanics Effects of Flutter Valve in Bronchiectasis Patients

A study testing Flutter Valve in people with Bronchiectasis, run by Universidade Federal do Rio de Janeiro at 2 sites in Brazil.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Considering that respiratory physiotherapy lack scientific evidence to support its application in the treatment of several obstructive diseases, this investigation was designed to evaluate the hypothesis that Flutter Valve can improve the airway clearance of hypersecretive bronchiectasis patients. Read more about this study

Who is it for?
Ages 28 to 92 years
Conditions the study is for
Bronchiectasis
What is being tested?
Flutter Valve
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
8 participants
Where
2 sitesBrazil
Study dates
Sep 2004to Jun 2006
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 28 to 92 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • patients with clinical and high-resolution computerized tomography diagnosis.

Who cannot join

  • chest pain,
  • acute hemoptysis,
  • recent history of rib fracture or pneumothorax (less than 1 year),
  • respiratory infection in the four weeks before measurements,
  • asthma,
  • cystic fibrosis,
  • daily sputum production lower than 25 mL/day

Trial locations and contacts

2 sites in 1 country.

Brazil2 sites
  • Universidade Federal do Rio de Janeiro

    Rio de Janeiro, Rio de Janeiro, 21941-902

  • Hospital Universitário Clementino Fraga Filho

    Rio de Janeiro, Rio de Janeiro, 21949-900

Other trials in Brazil

About this study

Official title: Flutter Valve Improves Respiratory Mechanics and Sputum Production in Bronchiectasis Patients

Considering that respiratory physiotherapy lack scientific evidence to support its application in the treatment of several obstructive diseases, this investigation was designed to evaluate the hypothesis that Flutter Valve can improve the airway clearance of hypersecretive bronchiectasis patients.

Read the detailed description

The application of airway clearance techniques is considered an important component in the treatment of bronchiectasis patients (Van der Shans, 1997). For this purpose, a number of techniques has been introduced in the last decades. The Flutter Valve was initially proposed for the treatment of children with cystic fibrosis (CF) (Lindemann, 1992), but there is not enough evidence about its utilization in patients with bronchiectasis (Van der Shans \& cols, 1999).

The effects of the Flutter Valve on respiratory mechanics of patients with bronchiectasis have been evaluated by forced spirometry (Pryor e cols, 1994; Gondor e cols, 1999; Thompson e cols, 2002). This approach however, does not allow the characterization of mucus transportation along the airways (Williams, 1994). The forced oscillation technique (FOT), a non-invasive alternative to characterize respiratory mechanics, allows the evaluation of respiratory mechanics at different frequencies without special maneuvers (Dubois e cols., 1956). According to eligibility criteria and in a randomized order, the patients were submitted to two protocols (control and Flutter Valve intervention), with one-week interval between them (washout). Respiratory mechanics and expectorated sputum volume were assessed before and after each intervention, in order to assess the Flutter Valve effect on tracheobronchial sputum removal.

Conditions
Bronchiectasis
Being tested
Flutter Valve
Keywords
bronchiectasis, physiotherapy, flutter valve, impulse oscillation technique
Medical subject headings
Bronchiectasis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Flutter ValveDevice

    Also called FLUTTER® Mucus Clearance Device

    Flutter Valve (Scandipharm, Birmingham, AL) is shaped like a pipe with a hardened plastic mouthpiece at one end, a plastic protective, perforated cover at the other end, and a high-density stainless steel ball resting in a plastic circular cone on the inside. When the patient expires, a vibratory effect is transmitted to airways by the steel ball oscillation in order to facilitate mucociliary clearance.

    In our study, the use of the equipment was guided by a registered physical therapist, but the position (angle) was determined by the patient, according to his/her adaptation and perception of effectiveness of sputum clearance. The patients remained comfortably seated, breathing through the device for 15 minutes, starting from the total pulmonary capacity, and being free to cough. Thereafter, a 5-minute session of cough was done.

Study groups in NCT00656721
Study groupRoleWhat they receive
Flutter ValveExperimentalThis a crossover study, so all subjects performed both, control and experimental interventions. In Flutter Valve intervention the subjects remained comfortably seated, breathing through the device for 15 minutes, starting off from the total pulmonary capacity, and being free to cough. Thereafter, a 5-min session of cough ensued. In the control intervention the subjects followed the same sequence of the Flutter Valve intervention, but the metallic sphere and the cover of the device were removed. Since the patients were not acquainted with the valve, they did not know its proper assembly. As in the Flutter Valve intervention, during 15 minutes the patients could expectorate spontaneously and return to the device. A 5-min coughing session took place.
Receives: Device: Flutter Valve

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Expectorated sputum volume.

    Measured: After each evaluated procedure (control and Flutter Valve intervention)

Secondary outcomes (1)
  1. Respiratory mechanics (spectral data recorded by impulse oscillation technique).

    Measured: Before and after each applied procedure (control and Flutter Valve intervention)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted11 Apr 2008 (estimated)
  2. Study startSep 2004
  3. Primary completionNov 2005
  4. Study completionJun 2006

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
8 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00656721
Sponsor's protocol ID
002434-UFRJ
Status last verified
Jun 2015
First submitted
7 Apr 2008
Last updated
22 Jun 2015
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Flutter Valve in people with Bronchiectasis, run by Universidade Federal do Rio de Janeiro at 2 sites in Brazil.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 22 Jun 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Brazil. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Expectorated sputum volume. (time frame: After each evaluated procedure (control and Flutter Valve intervention)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Jun 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in