AzTrials
AzTrials

Respiratory Distress SyndromeNCT00887731

Clinical Evaluation of a Closed Loop Oxygen Controller for Neonatal Respiratory Care

An observational study of Respiratory Distress Syndrome and Hyperoxia, run by University of Utah at 2 sites in United States.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Nearly forty years ago Berran and coworkers tested an analog oxygen controller to maintain incubator oxygen levels for infants suffering neonatal respiratory disease in order to prevent hyperoxia. Read more about this study

Who is it for?
Ages Up to 3 months
How many people
20 participants
Where
2 sitesUnited States
Study dates
Aug 2009to Mar 2013
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Up to 3 months
  • All sexes
  • No healthy volunteers
  • Child

Study population: Any neonatal intensive care patient who is requiring oxygen therapy as part of their respiratory treatment course will be eligible for this study.

Who may be able to join

  • Any neonatal intensive care patient who is requiring oxygen therapy as part of their respiratory treatment course will be eligible for this study.
  • Parental consent

Who cannot join

  • Infant on room air

Trial locations and contacts

2 sites in 1 country.

United States2 sites
  • Primary Children's Medical Center

    Salt Lake City, Utah, 84113

  • University of Utah Health Sciences Center

    Salt Lake City, Utah, 84132

Other trials in United States

About this study

Nearly forty years ago Berran and coworkers tested an analog oxygen controller to maintain incubator oxygen levels for infants suffering neonatal respiratory disease in order to prevent hyperoxia.

There are at least three clinical issues that this technology addresses: the first is avoidance of episodic hyperoxia; the second is decreasing episodic hypoxia; and the third is lowering cumulative oxygen exposure.

Read more

Clinical trials which have used target SpO2 ranging probably help improve all of these problems, but so far there have been no direct measurements of continuous arterial oxygen levels, nor clinical studies which establish the degree to which improving control over blood oxygen saturation decreases the cumulative amount of oxygen exposure. This study will address the later and is an important step in the process of incorporating closed-loop oxygen control technology as a routine standard of neonatal respiratory care.

OBJECTIVES:

PART 1: Test and modify the instruction set for the computerized oxygen controller to achieve a goal of less than six (6) operator required interruptions per hour for oxygen saturation deviations outside of study guidelines.

PART 2: Perform a within patient cross-over trial of the computerized oxygen controller versus standard of care (the patient's care team adjusts the patient's oxygen level) and evaluate the area under the time curve for oxygen exposure between the two control methods.

PART 3:(After successful completion of PART 2) Continuation of the within patient cross-over study with a randomized cross-over sequence. Studies will last 4 to 12 hours divided in two (2) equal time blocks with one cross-over to either automatic or manual control modes. Provision for up to an additional twenty (20) patients to be studied.

Read the detailed description

Nearly forty years ago Berran and coworkers tested an analog oxygen controller to maintain incubator oxygen levels for infants suffering neonatal respiratory disease in order to prevent hyperoxia.

  1. The system was able to regulate to within 1% of the set inspired oxygen level and resulted in stable infant arterial oxygen levels measured transcutaneously. Twenty years later, with the advent of pulse oximetry and computer technology, open loop control of infant oxygen saturation was studied in newborns using computer programs incorporating fuzzy logic and clinical algorithms.
  2. During computer-assisted inspired oxygen adjustment there was less variability in pulse oximeter oxygen saturation levels (SpO2) and patients spent more time within the target oxygen saturation range. The next technology step was to move from open to closed loop control, as was done by Claure et al in 2001.
  3. These investigators found that closed loop control of inspired oxygen was at least as effective as a fully dedicated nurse in maintaining SpO2 within the target range, and that it may be more effective than a nurse working under routine conditions. Percent of recording time spent at normoxia increased from 66% to 75%. Other bench research suggests that closed loop oxygen controllers based on SpO2 monitoring can have response times within 20 seconds and be able to maintain SpO2 within three percent saturation.
  4. In a clinical crossover trial it was shown that compared to routine inspired oxygen control management by bedside personnel, closed loop control of inspired oxygen concentration significantly increased time within target saturation range from 82% to 91%.
  5. The importance of controlling oxygen exposure in neonates has been long standing, especially as it relates to retinopathy of prematurity and bronchopulmonary dysplasia. The prospect for decreasing oxygen related morbidities is still a real and an ongoing topic for process change directed to overcoming treatment barriers.
  6. Maintaining oxygen saturation tightly within appropriate treatment ranges appears to improve both short and long term outcomes, including developmental indices.
  7. Given the improvement in oxygen exposure that can be realized by closed-loop control of inspired oxygen concentration as demonstrated above, the development of commercial devices that incorporate this technology is highly desirable and a positive move toward uniform control of oxygen exposure for neonates. There are at least three clinical issues that this technology addresses: the first is avoidance of episodic hyperoxia; the second is decreasing episodic hypoxia; and the third is lowering cumulative oxygen exposure.
Keywords
closed loop oxygen controller, premature infants, oxygen exposure
Medical subject headings
Respiratory Distress Syndrome, Hyperoxia, Premature Birth

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

Study groups in NCT00887731
Study groupRoleWhat they receive
Part 1 groupObservational study with a convenience sample of ten (10) patients. PART 1 will end when at least 3 of 4 consecutive patients achieve the goal of less than six (6) operator required interruptions per hour for oxygen saturation deviations from study guidelines, or at ten (10) patients.
Part 2 group(After successful completion of PART 1) Within patient cross-over study with a randomized cross-over sequence. Sequential data analysis methods will be used to help minimize the patient sample size which will be no more than twenty (20) patients plus up to a maximum of seven (7) who might be eligible from PART 1.
Part 3 Group(After successful completion of PART 2) Within patient cross-over study with a randomized cross-over sequence. Studies will last 4 to 12 hours divided in two (2) equal time blocks with one cross-over to either automatic or manual control modes.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. PART 1: Test and modify the instruction set for the computerized oxygen controller to achieve a goal of less than six (6) operator required interruptions per hour for oxygen saturation deviations outside of study guidelines.

    Measured: 2-4 hours

Secondary outcomes (2)
  1. PART 2: Perform a within patient cross-over trial of the computerized oxygen controller versus standard of care and evaluate the area under the time curve for oxygen exposure between the two control methods.

    Measured: 12 hours

  2. Part 3

    Perform a within patient cross-over trial of the computerized oxygen controller versus standard of care and evaluate the area under the time curve for oxygen exposure between the two control methods. Studies will last 4 to 12 hours divided in two (2) equal time blocks with one cross-over to either automatic or manual control modes.

    Measured: 12 hrs

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Apr 2009 (estimated)
  2. Study startAug 2009
  3. Primary completionMar 2013
  4. Study completionMar 2013

Why it stopped: slow enrollment

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case crossover
Time perspective
Prospective
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00887731
Sponsor's protocol ID
30125
Status last verified
Sep 2013
First submitted
22 Apr 2009
Last updated
12 Sep 2013
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

An observational study of Respiratory Distress Syndrome and Hyperoxia, run by University of Utah at 2 sites in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 12 Sep 2013. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: slow enrollment). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

PART 1: Test and modify the instruction set for the computerized oxygen controller to achieve a goal of less than six (6) operator required interruptions per hour for oxygen saturation deviations outside of study guidelines. (time frame: 2-4 hours). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Sep 2013.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.