Comparison of Neointimal Coverage Between Zotarolimus Eluting Stent and Everolimus Eluting Stent

A Phase 4 study testing Zotarolimus eluting stent (Endeavor resoulte - ZES resolute) and Everolimus eluting stent (Xience - EES) in people with Coronary Artery Disease, run by Yonsei University at 3 sites in South Korea.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Stent thrombosis is an important issue in drug eluting stents. Incomplete endothelial coverage and neointimal coverage over strut after drug eluting stent (DES) implantation could be a possible cause of stent thrombosis. Read more about this study

Who is it for?
Ages 20 to 80 years
Conditions the study is for
Coronary Artery Disease
What is being tested?
Zotarolimus eluting stent (Endeavor resoulte - ZES resolute) and Everolimus eluting stent (Xience - EES)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
40 participants
Where
3 sitesSouth Korea
Study dates
Dec 2008to not given
Phase
Phase 4
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Significant coronary de novo lesion (> 70% by quantitative angiographic analysis)
  • Patients with stable or acute coronary syndrome considered for coronary revascularization
  • Reference vessel diameter of 2.5 to 3.5 mm by operator assessment

Who cannot join

  • The criteria for exclusion were contraindication to anti-platelet agents
  • Proximal lesion within 15 mm from ostium
  • Different DES in other vessel simultaneously
  • Creatinine level 2.0 mg/dL or ESRD
  • Severe hepatic dysfunction (3 times normal reference values)
  • Pregnant women or women with potential childbearing
Show all 11Show fewer
  • Life expectancy 1 year
  • Complex lesion morphologies (aorto-ostial, bifurcation with > 2.0 mm side branch, unprotected left main, thrombus, severe calcification, chronic total occlusion)
  • Target lesion is vein graft lesion
  • Reference vessel < 2.5 mm or > 4.0 mm diameter by visual
  • Long lesion that require more than two stents

Trial locations and contacts

3 sites in 1 country.

South Korea3 sites
  • Dongsan Medical Center, Keimyung University

    Daegu, 700-712

  • Severance Hospital, Yonsei University

    Seoul, 120-752

  • Samsung Medical Center

    Seoul, 135-710

Other trials in South Korea

About this study

Official title: ComparisiOn of Neointimal coVerage betwEen zotaRolimus Eluting Stent and Everolimus Eluting Stent Using Optical Coherence Tomography at 9 Months (COVER OCT)

Stent thrombosis is an important issue in drug eluting stents. Incomplete endothelial coverage and neointimal coverage over strut after drug eluting stent (DES) implantation could be a possible cause of stent thrombosis. Therefore, theoretically dual antiplatelet therapy should be continued to prevent the stent thrombosis until complete reendothelialization. But, detection of endothelial coverage over stent is not possible with the available intravascular devices in clinical practice. Among currently available intravascular devices, intravascular optical coherence tomography (OCT) could give a more clear identification for a thin layer of neointima with high-resolution (10-20 μm) compared to intravascular ultrasound (100-150 μm). Previous OCT studies showed the significant different pattern of neointimal coverage between bare metal stent (BMS) and DES. In the investigators' experience, there were also some differences in neointimal coverage among the DESs, especially zotarolimus eluting stent (ZES). ZES has been known to be associated with significantly more neointimal coverage than SES at 8 months intravascular ultrasound (IVUS). Both everolimus eluting stent (EES) and ZES resolute were recently introduced. The efficacy to suppress the neointimal growth for ZES resolute and EES might be improved, but safety for neointimal coverage needs to evaluate in human coronary artery. Therefore, this study will investigate the pattern of neointimal coverage over stent in ZES resolute and EES at 9 months after stent implantation.

Read the detailed description

Recent autopsy study showed the most important histological and morphometric predictors of stent thrombosis were endothelial coverage and the ratio of uncovered to total strut after drug eluting stent (DES) implantation. Although there have been some controversies, incomplete stent apposition might be possible cause of very late stent thrombosis after DES implantation. Therefore, theoretically dual antiplatelet therapy should be continued to prevent the stent thrombosis until complete reendothelialization. But, detection of endothelial coverage over stent are no possible with available intravascular devices in clinical practice. Among currently available intravascular devices, intravascular optical coherence tomography (OCT) could give a more clear identification for a thin layer of NIH and malapposition with high-resolution (10 -20 μm) compared to intravascular ultrasound (100-150 μm). Previous OCT studies showed the significant different pattern of neointimal coverage between bare metal stent (BMS) and DES. In our experience, there was also some differences in neointimal coverage among the DESs, especially zotarolimus eluting stent (ZES). ZES have been known to be associated with significantly more neointimal coverage than SES at 8 months intravascular ultrasound (IVUS). This finding might be related with strut thickness and drug elution property. In our data, neointima was covered at 99.7% of stent strut in ZES, but 93.2% in sirolimus eluting stent (SES) at 9 month follow OCT. This difference was more distinct in patients with acute myocardial infarction (99.3% in ZES vs.79.9% in SES).

Both everolimus eluting stent (EES) was recently introduced and ZES resolute also will be available in the near future in Korea. Previous phosphorylcholine polymer was replaced with new, proprietary polymer which can provide extended elution kinetics in ZES resolute. Therefore, efficacy to suppress the neointimal growth might be improved but, safety for neointimal coverage needs to evaluate in human coronary artery. Both new DESs are cobalt chromium stent with thin stent strut and reported similar efficacy for suppressing the neointima growth. Also, endothelial coverage over stent strut occurred earlier compared to previous DESs (SES or PES) in animal experiments. But, there has been no data for neointimal coverage and malapposition of ZES resolute and EES using OCT in human coronary artery.

Recent paper according to Kubo et al reported that serial OCT examinations demonstrated markedly different vascular response up to 9 months after SES implantation between unstable angina and stable angina patients. These findings implied that initial native vessel status, which covered with stent, might be important and related with neointimal coverage and malapposition. But, there is little data evaluated the relationship between initial lesion status and neointimal coverage or late malapposition with OCT.

Therefore, this study investigates: 1) the relationship of the initial lesion and neointimal coverage or late malapposition and 2) the neointimal coverage and malapposition at 9 month after ZES resolute and EES implantation and 3) compare them between ZES resolute and EES at 9 months after stent implantation.

Study Objectives:

This study is a prospective open labeled randomized study to compare the neointimal coverage of ZES resolute (Endeavor® resolute) and EES (Xience®) in 9 month after stent implantation by OCT.

  1. Primary end point:
  • The primary endpoint is to compare the neointimal coverage of ZES resolute (Endeavor® resolute) and EES (Xience®) at 9 months after stent implantation by OCT.
  1. Secondary end points:
  • To investigate the relationship between initial lesion and neointimal coverage and malapposition at 9 months, and
  • To compare of neointimal growth between ZES resolute and EES at 9 months and to compare the difference in early and late malapposition between ZES resolute and EES at 9 months.
Being tested
Zotarolimus eluting stent (Endeavor resoulte - ZES resolute), Everolimus eluting stent (Xience - EES)
Medical subject headings
Coronary Artery Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Zotarolimus eluting stent (Endeavor resoulte - ZES resolute)Device

    Zotarolimus eluting stent (ZES)

  • Everolimus eluting stent (Xience - EES)Device

    Everolimus eluting stent (EES)

Study groups in NCT00894062
Study groupRoleWhat they receive
1Active comparatorZES resolute (Endeavor® resolute)
Receives: Device: Zotarolimus eluting stent (Endeavor resoulte - ZES resolute)
2Active comparatorEES (Xience®)
Receives: Device: Everolimus eluting stent (Xience - EES)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Evaluation of neointimal coverage of ZES resolute (Endeavor® resolute) and EES Xience®) by OCT.

    Measured: at 9 months after stent implantation

Secondary outcomes (2)
  1. Investigate the relationship between initial lesion and neointimal coverage and malapposition at 9 months.

    Measured: 9 months after stent implantation

  2. Comparison of neointimal growth between ZES resolute and EES at 9 months.

    Measured: 9 months after stent implantation

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 May 2009 (estimated)
  2. Study startDec 2008

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
40 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00894062
Sponsor's protocol ID
4-2008-0483
Acronym
COVER OCT
Status last verified
Jul 2009
First submitted
5 May 2009
Last updated
24 Mar 2010
Results posted
No
Data monitoring committee
Yes

Publications

  • Kim JS, Kim BK, Jang IK, Shin DH, Ko YG, Choi D, Hong MK, Cho YK, Nam CW, Hur SH, Choi JH, Song YB, Hahn JY, Choi SH, Gwon HC, Jang Y. ComparisOn of neointimal coVerage betwEen zotaRolimus-eluting stent and everolimus-eluting stent using Optical Coherence Tomography (COVER OCT). Am Heart J. 2012 Apr;163(4):601-7. doi: 10.1016/j.ahj.2011.10.016.

    PubMed 22520526

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing Zotarolimus eluting stent (Endeavor resoulte - ZES resolute) and Everolimus eluting stent (Xience - EES) in people with Coronary Artery Disease, run by Yonsei University at 3 sites in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 24 Mar 2010. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Evaluation of neointimal coverage of ZES resolute (Endeavor® resolute) and EES Xience®) by OCT. (time frame: at 9 months after stent implantation). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00894062, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Mar 2010; AzTrials last refreshed its copy on 7 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in