The AVB Study: Prospective Study Comparing the Ahmed Valve and the Baerveldt Implant for Treating Refractory Glaucoma

A study testing Ahmed FP7 Valve and Baerveldt-350 Tube in people with Glaucoma, run by Credit Valley EyeCare at 6 sites in 3 countries.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to compare the safety and efficacy of the Ahmed valve and the Baerveldt implant in treating refractory glaucoma. Eligible patients will be recruited from multiple study centers and randomized to a glaucoma drainage device for implantation. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Glaucoma
What is being tested?
Ahmed FP7 Valve and Baerveldt-350 Tube
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
238 participants
Where
6 sitesin 3 countries
Study dates
Jul 2005to Apr 2015
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age greater than or equal to 18.
  • Inadequately controlled glaucoma determined as intraocular pressure (IOP) greater than target, which has not responded to conventional medical and surgical therapy.
  • Patients with significant conjunctival scarring or high-risk disease (active neovascular glaucoma) precluding antimetabolite trabeculectomy will be included in the study.
  • Provide written informed consent to participate in the study.

Who cannot join

  • Age less than 18.
  • Patient will undergo an additional procedure at the time of glaucoma drainage device implantation (i.e. lensectomy, penetrating keratoplasty)
  • No light perception vision.
  • Patient has already been enrolled in the study in the contralateral eye.
  • Patient is unwilling or unable to provide informed consent to participate in the study, or adhere to the study requirements including implant randomization and required follow-up visits.

Trial locations and contacts

6 sites in 3 countries.

6 sites in 3 countries

United States3 sites
  • Eugene and Marilyn Glick Eye Institute

    Indianapolis, Indiana, 46202

  • Drs. Massaro and Kalenak

    Milwaukee, Wisconsin, 53226

  • Vanderbilt Eye Institute

    Nashville, Tennessee, 37232

Other trials in United States

Canada2 sites
  • Montreal Glaucoma Institute

    Montreal, Quebec, H1V 1G5

  • Credit ValleyEC

    Toronto, Ontario, L5L 1W8

Other trials in Canada

Chile1 site
  • Clinic of Las Condes

    Santiago

Other trials in Chile

About this study

Official title: The Ahmed Versus Baerveldt (AVB) Study: Prospective, Multicenter Trial Comparing the Ahmed-FP7 Valve With the Baerveldt-350 Implant in Treating Refractory Glaucoma

The purpose of this study is to compare the safety and efficacy of the Ahmed valve and the Baerveldt implant in treating refractory glaucoma. Eligible patients will be recruited from multiple study centers and randomized to a glaucoma drainage device for implantation. They will be followed long-term based upon outcome measures including intraocular pressure, glaucoma medication use, visual acuity, complications of the surgery and further treatments required.

Read the detailed description

Introduction:

The use of a glaucoma drainage device (GDD) is indicated in cases of refractory glaucoma not responsive to conventional medication, laser and surgical therapy. Most of these patients are at high risk for surgical failure, with serious concomitant ocular and systemic diseases. GDD's are increasingly being used to obtain low target intraocular pressures (IOP) in patients who have failed antimetabolite trabeculectomy or have active neovascular glaucoma.

Since Molteno's original design, several drainage devices have become commercially available for implantation. Currently, the two most commonly used devices are the Ahmed Glaucoma Valve (AGV) (New World Medical, Inc., Rancho Cucamonga, CA), and the Baerveldt Glaucoma Device (BGD) (Advanced Medical Optics, Santa Ana, CA). The AGV, with a venture-based flow-restrictive valve is helpful in minimizing postoperative hypotony and complications associated with hypotony, including flat anterior chamber, choroidal effusions, and suprachoroidal hemorrhage. However, there appears to be a high rate of encapsulation and hypertension associated with this device, and increased requirement of postoperative glaucoma medication use. The BGD, a non-valved device, requires early ligature of flow by the use of a suture restriction to allow adequate time for bleb formation. Although this can result in an initial post-operative hypertension phase, it results in less encapsulation and theoretically fewer postoperative glaucoma medications and better IOP control. However, the lack of a flow-restrictor and the large filtering surface area may result in a greater risk for hypotony related complications.

Although several studies comparing the AGV and BGD have been reported, they have all been retrospective, nonrandomized, small scale, and compare different patient populations. The results have been inconclusive and conflicting in evaluating the relative efficacy and characteristics of these two devices, and further research needs to be done in order to answer these questions.

Objective:

The Ahmed vs. Baerveldt (AVB) Study is the first multicenter prospective randomized clinical trial comparing the Ahmed FP7 valve and the Baerveldt-350 tube shunt glaucoma drainage devices. Primary outcome is surgical failure, a composite criteria evaluating the intraocular pressure lowering effect of the devices, complications of the surgery, treatments for complications, glaucoma medication use, and the preservation of visual acuity. Secondary outcomes will evaluate these variables individually, and any non-glaucoma related ocular pathology and required interventions.

AVB Study Manual:

An AVB Study Manual including the study design and protocol, standardized surgical technique, patient education and consent form, and data collection protocol was distributed to each clinical site. The contents of the manual received ethics approval by the Institutional Review Board (IRB) at the primary site.

Study Organization:

  1. Investigator Committee (IC): Composed of study investigators and under the leadership of the Study Chair. The IC's responsibilities are defined below:
  2. Designing the study protocol to ensure valid scientific method and proper ethical conduct.
  3. Overseeing clinical centers to ensure that the protocol and ethical standards of the study are being upheld.
  4. Overseeing the Data Acquisition \& Statistical Center to ensure that all practices are in accordance with those outlined in the protocol, and meet the ethical standards of the study.
  5. Drafting and editing study documents critically for intellectual content and ethical considerations.
  6. Clinical Centers (CC): Composed of study sites led by a Site Primary Investigator, whose responsibilities are defined below:
  7. Enrolling patients in the study after determining eligibility and providing patient education. Informed consent must be written.
  8. Ensuring that the study protocol and ethical standards of the study are upheld.
  9. Ensuring that the study adheres to the policies set forth by the local Institutional/Ethical Review Board.
  10. Acquiring study data and making it available to the Data Monitoring \& Statistics Committee.
  11. Data Acquisition \& Statistical Center (DASC): Composed of Study Director and Study Statistician, with the following responsibilities:
  12. Acquiring study data from each Clinical Center using the online study database (http://www.avsbstudy.com)
  13. Statistical analysis of the study data.

Methods:

Patient Enrollment and Treatment Assignment:

Patients were recruited from 7 study sites by 10 surgeons. After patient eligibility and written informed consent was obtained by the Site PI, randomization to placement of an Ahmed FP7 valve or a Baerveldt-350 tube shunt was made by coin toss.

Pre-operative data collection:

The following data was collected in the 3 months prior to surgery: date of birth, gender, race, glaucoma diagnosis and etiology, past ocular history (diagnoses, surgical and laser procedures), best corrected visual acuity, intraocular pressure, glaucoma medication use, abnormal slit lamp findings, and abnormal fundus exam findings.

Surgical Procedure:

The surgical procedures used for the AVB Study are standardized, and any complications during surgery will be noted and defined.

Ahmed FP7 valve implantation:

A superior or inferior corneal traction suture with 8-0 Vicryl was placed for globe fixation as required. A 90-degree conjunctival peritomy was followed by blunt dissection to mobilize a fornix or limbus-based conjunctival flap over the area of intended device implantation. Non-preserved lidocaine 1% was injected under the conjunctival flap, posteriorly, and under the extraocular muscle bellies with a blunt cannula. Gentle cautery was used to obtain hemostasis.

The Ahmed Glaucoma Valve model FP-7 was primed with balanced salt solution, and placed in the intended quadrant. The plate was sutured to sclera 8-10mm posterior to the limbus with two 8-0 or 10-0 Nylon sutures.

A paracentesis was made if required, and a viscoelastic agent used to form the anterior chamber. A 22-gauge needle was used to create needle tract into the anterior chamber.

The tube was trimmed, and placed into the anterior chamber through the needle tract. The tube was attached to the sclera using a 10-0 Nylon suture if required. A sclera or corneal graft was placed over the tube and sutured to the sclera with 10-0 Nylon.

The conjunctival flap was closed with 8-0 or 10-0 Vicryl suture. At the conclusion of the case, Maxitrol ointment was placed on the eye. No patients were patched, although shields were given to patients. That day, patients were started on antibiotic and steroid eye drops. A cycloplegic was used as indicated.

Baerveldt-350 tube shunt implantation:

A superior or inferior corneal traction suture with 8-0 Vicryl was placed for globe fixation. A 90 to 120-degree conjunctival peritomy was followed by blunt dissection to mobilize a fornix or limbus-based conjunctival flap over the area of intended device implantation. Non-preserved lidocaine 1% was injected under the conjunctival flap, posteriorly, and under the extraocular muscle bellies with a blunt cannula. Gentle cautery was used to obtain hemostasis.

Both adjacent extraocular muscles were isolated using a muscle hook. 4-0 silk sutures were used for fixation if necessary.

The Baerveldt drainage device model BG101-350 was checked with balanced salt solution, and a 4-0 Nylon releasable intraluminal suture was placed. A 7-0 or 8-0 Vicryl ligature suture was placed around the tube. The plate was placed in the intended quadrant and under the muscle bellies. The plate was sutured to the sclera 8-12mm posterior to the limbus with two 8-0 or 10-0 Nylon sutures.

A paracentesis was made if it was required, and a viscoelastic agent used to form the anterior chamber. A 22-gauge needle was used to create needle tract into the anterior chamber. The tube was trimmed, and placed into the anterior chamber through the needle tract. The tube was attached to the sclera using a 10-0 Nylon suture if required. A sclera or corneal graft was placed over the tube and sutured to the sclera.

The conjunctival flap was closed with an 8-0 or 10-0 Vicryl suture. At the conclusion of the case, Atropine 1% drops and Maxitrol ointment was placed on the eye. No patients were patched, although shields were given to patients. On the day of surgery, patients were started on antibiotics and steroid eye drops. A cycloplegic agent was used as indicated.

Post-operative data collection:

Patients were seen post-operatively at a minimum of 1 day, 1 week, 2 weeks, 1 month, 2 months, 3 months, 6 months, 12 months, 18 months 2 years, 3 years, 4 years and 5 years. Further visits were made as deemed necessary. At each visit, the following data was collected:

  1. Intraocular pressure (IOP) by Goldmann Applanation Tonometry
  2. Visual Acuity (VA) using a Snellen Chart or Low Vision Chart
  3. Glaucoma Medication Use
  4. Slit Lamp Biomicroscopy \& Ophthalmoscopy
  5. Complications of Surgery
  6. Interventions/Treatment of Complications

Outcome measures:

Based upon the pre-operative data and post-operative results, a study outcome will be assigned to each patient, as defined below:

Complete Success: (requires all of the following criteria)

  1. IOP: 5 mmHg <= IOP <= 18 mmHg with a reduction in IOP of 20% or greater from baseline at every visit after 3 months.
  2. Medications: No anti-glaucoma medications are required.
  3. Complications: No vision threatening complications related to the implant/surgery.
  4. Interventions: No additional glaucoma surgery or laser procedures are allowed.
  5. Vision: No greater than a doubling of the mean angle of resolution (logMAR), which corresponds to approximately 2 Snellen lines.

Qualified Success: (requires all of the following criteria)

  1. IOP: 5 mmHg <= IOP <= 18 mmHg with a reduction in IOP of 20% or greater from baseline, with no two consecutive visits after 3 months which do not meet this criterion.
  2. Medications: Anti-glaucoma medications may be used.
  3. Surgery/Complications: No vision threatening complications or surgery occurred after implantation of the GDD.
  4. Interventions: Surgical and laser interventions to correct non-vision threatening complications of implant/surgery are allowed, but no additional glaucoma procedures are allowed.
  5. Vision: No progression to no light perception.

Failure: (if any of the following criteria are met)

  1. IOP: IOP <5 mmHg or >18 mmHg or reduction <20% from pre-operative IOP in two consecutive visits after 3 months.
  2. Surgery/Complications: Vision threatening complications or surgery required that is related to the implant. This includes severe choroidal effusions requiring drainage, suprachoroidal hemorrhage, endophthalmitis or malignant glaucoma requiring surgery.
  3. Interventions: An additional glaucoma procedure is required (e.g. cyclodestruction, gold shunt implantation).
  4. Vision: Progression to no light perception.
Conditions
Glaucoma
Being tested
Ahmed FP7 Valve, Baerveldt-350 Tube
Keywords
Glaucoma Drainage Device, Aqueous Shunt Implant, Ahmed Valve, Baerveldt Tube, Refractory Glaucoma
Medical subject headings
Glaucoma

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Ahmed FP7 ValveDevice

    Also called New World Medical, AGV FP7

    Implantation of Ahmed FP7 Valve to lower intraocular pressure in refractory glaucoma.

  • Baerveldt-350 TubeDevice

    Also called Advanced Medical Optics, BG 101-350

    Implantation of Baerveldt-350 Tube to lower intraocular pressure in refractory glaucoma.

Study groups in NCT00940823
Study groupRoleWhat they receive
Ahmed FP7 ValveActive comparatorAhmed valve glaucoma drainage device implant for treatment of refractory glaucoma.
Receives: Device: Ahmed FP7 Valve
Baerveldt-350 TubeActive comparatorBaerveldt tube glaucoma drainage device implant for treatment of refractory glaucoma.
Receives: Device: Baerveldt-350 Tube

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of Participants With Surgical Failure (Composite Measure)

    1. IOP out of target range (5-18 mmHg inclusive) or <20% reduction from baseline for 2 consecutive visits after 3 months.
    2. De novo glaucoma surgery required (e.g., cyclodestructive procedure, additional tube shunt).
    3. Removal of the implant.
    4. Severe vision loss related to the surgery (endophthalmitis, suprachoroidal hemorrhage with vision loss, enucleation, evisceration, or phthisis bulbi) or progression to no light perception for any reason.

    Measured: 5 years

Secondary outcomes (5)
  1. Intraocular Pressure (IOP)

    Measured: 5 years

  2. Anti-glaucoma Medications

    Measured: 5 years

  3. LogMAR Snellen Visual Acuity

    Visual acuity (VA) was tested monocularly (one eye at a time) using the manifest refraction adjusted for optical infinity using a standard Snellen Visual Acuity chart at 20 feet. Normal vision, or 20/20 vision, means that the participant can see at 20 feet what a healthy control can also see at 20 feet. Legal blindness, or 20/200 vision, means the participant can see at 20 feet what a healthy control can see at 200 feet. Hence, an increasing denominator implies visual impairment. Counting fingers was designated as 20/2000 vision, hand motions was 20/16000, light perception was 20/32000 and no light perception was 20/64000. To allow for appropriate statistical analysis, logMAR Snellen Visual Acuity was calculated using the formula: -logMAR (Snellen Acuity). This means that normal vision (20/20) would correspond to a value of 0, legal blindness (20/200) would correspond to a value of 1, and no light perception (20/64000) would correspond to 3.5.

    Measured: 5 years

  4. Number of Participants With Complications During or After Surgery

    Measured: 5 years

  5. Number of Participants With Interventions After Surgery

    Measured: 5 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 Jul 2009 (estimated)
  2. Study startJul 2005
  3. Primary completionApr 2014
  4. Study completionApr 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
238 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00940823
Sponsor's protocol ID
CVEC-AVB
Other IDs
GRSC-2005
Status last verified
Mar 2018
First submitted
15 Jul 2009
Last updated
13 Mar 2018
Data monitoring committee
No

Publications

  • Syed HM, Law SK, Nam SH, Li G, Caprioli J, Coleman A. Baerveldt-350 implant versus Ahmed valve for refractory glaucoma: a case-controlled comparison. J Glaucoma. 2004 Feb;13(1):38-45. doi: 10.1097/00061198-200402000-00008.

    PubMed 14704542
  • Wang JC, See JL, Chew PT. Experience with the use of Baerveldt and Ahmed glaucoma drainage implants in an Asian population. Ophthalmology. 2004 Jul;111(7):1383-8. doi: 10.1016/j.ophtha.2003.11.005.

    PubMed 15234141
  • Tsai JC, Johnson CC, Dietrich MS. The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma: a single-surgeon comparison of outcome. Ophthalmology. 2003 Sep;110(9):1814-21. doi: 10.1016/S0161-6420(03)00574-8.

    PubMed 13129882
  • Tsai JC, Johnson CC, Kammer JA, Dietrich MS. The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma II: longer-term outcomes from a single surgeon. Ophthalmology. 2006 Jun;113(6):913-7. doi: 10.1016/j.ophtha.2006.02.029.

    PubMed 16751034
  • Goulet RJ 3rd, Phan AD, Cantor LB, WuDunn D. Efficacy of the Ahmed S2 glaucoma valve compared with the Baerveldt 250-mm2 glaucoma implant. Ophthalmology. 2008 Jul;115(7):1141-7. doi: 10.1016/j.ophtha.2007.10.034. Epub 2007 Dec 27.

    PubMed 18164068
  • Coleman AL, Hill R, Wilson MR, Choplin N, Kotas-Neumann R, Tam M, Bacharach J, Panek WC. Initial clinical experience with the Ahmed Glaucoma Valve implant. Am J Ophthalmol. 1995 Jul;120(1):23-31. doi: 10.1016/s0002-9394(14)73755-9.

    PubMed 7611326
  • Huang MC, Netland PA, Coleman AL, Siegner SW, Moster MR, Hill RA. Intermediate-term clinical experience with the Ahmed Glaucoma Valve implant. Am J Ophthalmol. 1999 Jan;127(1):27-33. doi: 10.1016/s0002-9394(98)00394-8.

    PubMed 9932995
  • Krishna R, Godfrey DG, Budenz DL, Escalona-Camaano E, Gedde SJ, Greenfield DS, Feuer W, Scott IU. Intermediate-term outcomes of 350-mm(2) Baerveldt glaucoma implants. Ophthalmology. 2001 Mar;108(3):621-6. doi: 10.1016/s0161-6420(00)00537-6.

    PubMed 11237919
  • Lloyd MA, Baerveldt G, Fellenbaum PS, Sidoti PA, Minckler DS, Martone JF, LaBree L, Heuer DK. Intermediate-term results of a randomized clinical trial of the 350- versus the 500-mm2 Baerveldt implant. Ophthalmology. 1994 Aug;101(8):1456-63; discussion 1463-4. doi: 10.1016/s0161-6420(94)31152-3.

    PubMed 8058290
  • Britt MT, LaBree LD, Lloyd MA, Minckler DS, Heuer DK, Baerveldt G, Varma R. Randomized clinical trial of the 350-mm2 versus the 500-mm2 Baerveldt implant: longer term results: is bigger better? Ophthalmology. 1999 Dec;106(12):2312-8. doi: 10.1016/S0161-6420(99)90532-8.

    PubMed 10599663
  • Nouri-Mahdavi K, Caprioli J. Evaluation of the hypertensive phase after insertion of the Ahmed Glaucoma Valve. Am J Ophthalmol. 2003 Dec;136(6):1001-8. doi: 10.1016/s0002-9394(03)00630-5.

    PubMed 14644209
  • Law SK, Nguyen A, Coleman AL, Caprioli J. Comparison of safety and efficacy between silicone and polypropylene Ahmed glaucoma valves in refractory glaucoma. Ophthalmology. 2005 Sep;112(9):1514-20. doi: 10.1016/j.ophtha.2005.04.012.

    PubMed 16005977
  • Ayyala RS, Harman LE, Michelini-Norris B, Ondrovic LE, Haller E, Margo CE, Stevens SX. Comparison of different biomaterials for glaucoma drainage devices. Arch Ophthalmol. 1999 Feb;117(2):233-6. doi: 10.1001/archopht.117.2.233.

    PubMed 10037569
  • Ayyala RS, Michelini-Norris B, Flores A, Haller E, Margo CE. Comparison of different biomaterials for glaucoma drainage devices: part 2. Arch Ophthalmol. 2000 Aug;118(8):1081-4. doi: 10.1001/archopht.118.8.1081.

    PubMed 10922202
  • Gedde SJ, Schiffman JC, Feuer WJ, Parrish RK 2nd, Heuer DK, Brandt JD; Tube Versus Trabeculectomy Study Group. The tube versus trabeculectomy study: design and baseline characteristics of study patients. Am J Ophthalmol. 2005 Aug;140(2):275-87. doi: 10.1016/j.ajo.2005.03.031.

    PubMed 16086949

Questions about this trial

What is this clinical trial studying?

A study testing Ahmed FP7 Valve and Baerveldt-350 Tube in people with Glaucoma, run by Credit Valley EyeCare at 6 sites in 3 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 13 Mar 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 6 sites in United States, Canada, Chile. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 13 Mar 2018). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of Participants With Surgical Failure (Composite Measure) (time frame: 5 years). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00940823, which also lists 21 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Mar 2018; AzTrials last refreshed its copy on 29 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in