AzTrials
AzTrials

Implantable Cardioverter-DefibrillatorsECOSTNCT00989417

Benefits of Implantable Cardioverter Defibrillator Follow-up Using Remote Monitoring

A study testing ACTIVATION of HOME MONITORING in people with Implantable Cardioverter-Defibrillators and Ventricular Fibrillation, run by Biotronik SE & Co. KG at 1 site in France.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

In many aspects of every-day life, modern communication systems bring about a remarkable increase in comfort and safety by transmitting data and information in an easy and reliable manner. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
ACTIVATION of HOME MONITORING
Could I receive a placebo?
No, everyone receives an active treatment
How many people
473 participants
Where
1 siteFrance
Study dates
Jan 2007to Oct 2010
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Indication for single or dual chamber ICD

Who cannot join

  • NYHA class IV
  • Pregnant woman or woman who plan to become pregnant during the trial
  • Patient whose medical situation is not stable
  • Presence of any disease, other than patient's cardiac disease, associated with reduced likelihood of survival for the duration of the trial, e.g. cancer, uraemia (urea > 70mg/dl or creatinine >3mg/dl), liver failure, etc.
  • Age < 18 years
  • Patient unable to handle Home Monitoring system correctly
Show all 11Show fewer
  • The patient is not willing and able to comply with the protocol
  • Change of residence expected during study
  • Insufficient GSM coverage at patient's home
  • Participation in another clinical study
  • Patient unwilling to sign the consent for participation.

Trial locations and contacts

1 site in 1 country.

France1 site
  • CHRU de Lille- Hôpital Cardiologique

    Lille

Other trials in France

About this study

Official title: Effectiveness and Cost Of ICD Follow-up Schedule With Telecardiology

In many aspects of every-day life, modern communication systems bring about a remarkable increase in comfort and safety by transmitting data and information in an easy and reliable manner. In order to provide these advantages also to patients with implantable cardioverter-defibrillators, as well as to their physicians, BIOTRONIK has developed a long-distance implant telemetry to enable periodic trend and event-triggered transmissions of implant data and intracardiac electrogram over distances of several meters. The data is received by a patient device and subsequently automatically transferred to a BIOTRONIK Service Center that provides it to the physician on a password secured internet site. Hence, the physician receives diagnostic information without the patient having to visit the physician (Home Monitoring, HM). New possibilities will arise for a detailed medical and event-correlated supervision of the patient's therapy using electrically active implants.

Read the detailed description

State-of-the-art implantable cardioverter defibrillators (ICD) provide a variety of algorithms to optimize episode classification and to minimize the danger of delivering inadequate therapies. An important role in checking the correctness of episode detection, classification and treatment plays the intracardiac electrogram (IEGM), which is stored inside the ICD for every detected episode. However, to analyze the stored IEGM, the physician has to interrogate the implant, i.e. the patient has to visit the ICD ambulance for follow-up. As a result, follow-ups are performed principally to corroborate that the ICD has correctly classified and treated detected tachycardia episodes, to optimize the parameters and in case of adverse event detection, to modify the programmation.

The extension of BIOTRONIK Home Monitoring® by IEGM-Online® with LUMOS ICD offers a new possibility to meet the following challenge:

Due to its integrated long-distance telemetry, the implantable cardioverter defibrillator (ICD) LUMOS is capable of periodically transmitting data and IEGM-online from the ICD memory to the BIOTRONIK Service Center via patient device. The BIOTRONIK Service Center decodes the data and presents it to the physician on a password secured internet site. Additionally, in case certain event criteria are met, the most important Home Monitoring information is immediately faxed to the physician as an Event Report. These events can be customized by the physician. Thus, the physician will be able to closely monitor the patient and check the adequacy and efficiency of the ICD therapy without requiring the patient to visit the physician. The transmitted data comprise information on atrial and ventricular rhythm, atrioventricular conduction and system status.

The purpose of the present study is to evaluate the safety and economic impact of ICD follow-up schedule with Home Monitoring in France. For this assessment, the investigation compares two groups: For the ACTIVE group, after a first follow-up, the patients are only followed by Home Monitoring and one follow-up per year. The ICD follow-up or therapeutic intervention will be primarily based and triggered on event reports reception and after cardio reports and IEGM-online analysis on internet site. The findings from this group will be compared to those of a group receiving standard of care (CONTROL group). Both patient groups will be followed for 27 months and will have Home Monitoring switched on. The data from the CONTROL group will not be presented online to the attending physician, but a retrospective analysis on differences between the two groups will be performed. The clinical study will analyse, the incidence of significant serious adverse events (composite of all-cause mortality, cardiac and device related SAE), the costs reduction, the home-monitoring workload, the quality of life, the incremental Costs/Effectiveness ratio, the patient willing-to-pay, the delay of Home Monitoring to manage adverse events, the sensitivity of Home Monitoring to detect ICD dysfunctions, the inappropriate therapies rate and impact on hospitalization, the number of ICD charge and impact on battery longevity.

The trial will be conducted as a prospective, randomized, open, multicenter, national clinical trial. The enrolment of 400 patients in 40 clinical centres in France is anticipated

Being tested
ACTIVATION of HOME MONITORING
Keywords
Remote monitoring, Defibrillators, Implantable, Home monitoring, Shock, Implantable cardioverter-defibrillator Therapy
Medical subject headings
Ventricular Fibrillation, Tachycardia, Ventricular, Shock

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • ACTIVATION of HOME MONITORINGOther

    Both patient groups will be followed for 27 months and will have Home Monitoring switched on. The data from the CONTROL group will not be presented online to the attending physician, but a retrospective analysis on differences between the two groups will be performed.

Study groups in NCT00989417
Study groupRoleWhat they receive
CONTROL Group - Without Home MonitoringActive comparatorPatients receiving the standard of care. Due to safety concerns, the patients are followed every 6 months after a first follow-up, which is performed between 1 and 3 months after implantation.
Receives: Other: ACTIVATION of HOME MONITORING
ACTIVE GROUP With Home MonitoringExperimentalAfter a first follow-up (between 1 and 3 months after implantation), the patients are followed one time per year. Within this period, the additional ICD follow-up or therapeutic intervention will be primarily triggered on cardio-reports reception, Data/IEGM-online analysis on internet site or patient/physician call.
Receives: Other: ACTIVATION of HOME MONITORING

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of patients with more than one Significant Serious Adverse Event (SSAE) since home-monitoring activation. SSAE is a composite comprising all-cause mortality, cardiac or device related Serious Adverse Events

    Measured: 27 months

Secondary outcomes (5)
  1. Total costs minimization analyse

    Measured: 27 months

  2. Delay of Home Monitoring to manage adverse events

    Measured: 27 months

  3. Sensitivity of Home Monitoring to detect ICD dysfunction

    Measured: 27 months

  4. Number of capacitor charge and incidence on ICD-battery longevity

    Measured: 27 months

  5. Difference of cardiac and device related Adverse Event

    Measured: 27 Months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Oct 2009 (estimated)
  2. Study startJan 2007
  3. Primary completionOct 2010
  4. Study completionOct 2010

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Health services research
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
473 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00989417
Sponsor's protocol ID
FRA041
Acronym
ECOST
Status last verified
May 2011
First submitted
2 Oct 2009
Last updated
25 May 2011
Results posted
No
Data monitoring committee
Yes

Publications

  • Guedon-Moreau L, Lacroix D, Sadoul N, Clementy J, Kouakam C, Hermida JS, Aliot E, Kacet S; ECOST trial Investigators. Costs of remote monitoring vs. ambulatory follow-ups of implanted cardioverter defibrillators in the randomized ECOST study. Europace. 2014 Aug;16(8):1181-8. doi: 10.1093/europace/euu012. Epub 2014 Mar 9.

    PubMed 24614572
  • Guedon-Moreau L, Kouakam C, Klug D, Marquie C, Brigadeau F, Boule S, Blangy H, Lacroix D, Clementy J, Sadoul N, Kacet S. Decreased delivery of inappropriate shocks achieved by remote monitoring of ICD: a substudy of the ECOST trial. J Cardiovasc Electrophysiol. 2014 Jul;25(7):763-70. doi: 10.1111/jce.12405. Epub 2014 Apr 10.

    PubMed 24602062
  • Guedon-Moreau L, Lacroix D, Sadoul N, Clementy J, Kouakam C, Hermida JS, Aliot E, Boursier M, Bizeau O, Kacet S; ECOST trial Investigators. A randomized study of remote follow-up of implantable cardioverter defibrillators: safety and efficacy report of the ECOST trial. Eur Heart J. 2013 Feb;34(8):605-14. doi: 10.1093/eurheartj/ehs425. Epub 2012 Dec 13.

    PubMed 23242192

Questions about this trial

What is this clinical trial studying?

A study testing ACTIVATION of HOME MONITORING in people with Implantable Cardioverter-Defibrillators and Ventricular Fibrillation, run by Biotronik SE & Co. KG at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 25 May 2011. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of patients with more than one Significant Serious Adverse Event (SSAE) since home-monitoring activation. SSAE is a composite comprising all-cause mortality, cardiac or device related Serious Adverse Events (time frame: 27 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00989417, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 May 2011; AzTrials last refreshed its copy on 8 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in