Ischemic and Nonischemic Cardiomyopathy, With Primary and Secondary Implant IndicationsPropRNCT01032577
A Study Comparing the Sensed R Wave in Bipolar and Extended Bipolar Configurations
An observational study of Ischemic and Nonischemic Cardiomyopathy, With Primary and Secondary Implant Indications, run by Trinity Health Of New England at 1 site in United States.
Trial summary
The PropR study will evaluate sensing during ventricular fibrillation (VF) in both bipolar and extended bipolar configurations, in order to evaluate if both can be used interchangeably in caring for patients. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Ischemic and Nonischemic Cardiomyopathy, With Primary and Secondary Implant Indications
- How many people
- 50 participants
- Where
- 1 siteUnited States
- Study dates
- Dec 2009to Jul 2011
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: The patient population will include approximately 30-50 volunteers age >18, male and female, both ischemic and nonischemic cardiomyopathy, with primary and secondary implant indications.
Who may be able to join
- age > 18 with ability to give informed consent,
- patients who are expected to live more than one year,
- patients with indication for defibrillator implant,
- patients who are not pacemaker dependent,
- patients with either ischemic or nonischemic cardiomyopathy.
Who cannot join
- age < 18,
- inability to give informed consent,
- life expectancy less than one year,
- pacemaker dependence, or use of preexisting lead for sensing,
- any condition which would preclude ICD testing at the end of the implant,
- patients who are undergoing upgrade to an ICD from a pacemaker will also be excluded,
- patients with inherited arrhythmias or ion channel related arrhythmias will be excluded from the study.
Trial locations and contacts
1 site in 1 country.
United States1 site
St Francis Hospital and Medical Center
Hartford, Connecticut, 06105
About this study
Official title: Prospective Study Comparing the Sensed R Wave in Bipolar and Extended Bipolar Configurations
The PropR study will evaluate sensing during ventricular fibrillation (VF) in both bipolar and extended bipolar configurations, in order to evaluate if both can be used interchangeably in caring for patients. In addition, follow up evaluation of R wave amplitude over time would allow us to determine whether one configuration is more likely to be associated with change. This understanding would be important in selecting the proper configuration at the time of implant.
Read the detailed description
Hypothesis:
Sensing in bipolar and extended bipolar configurations are the same. However, sensing in bipolar over time is more likely to decrease when compared to extended bipolar.
Objectives:
- To compare bipolar sensing and extended bipolar sensing in VF.
- Compare sensing in bipolar and extended bipolar over time.
Methods:
- This study will be a randomized comparison of bipolar and extended bipolar sensing. As per usual standard of care, at the end of ICD implantation two sensing tests in VF will be performed. Patients will be randomized to sensing in VF through the device. Each patient will undergo testing in one randomized configuration followed by a second test in the other configuration. After testing at the time of implant, each patient will be seen at one month in follow up. Sensing of each configuration will be reevaluated at that time in sinus rhythm.
- Each patient will serve as their own control, as data for sensing in both configurations will be obtained in VF at the time of implant. During testing both signals types will be recorded simultaneously through the ICD. The primary endpoint will be duration of sensing (time to detection) in VF at the time of implant.
- The secondary endpoint will be sensing in sinus rhythm at one month.
- The patient population will include approximately 30-50 volunteers age >18, male and female, both ischemic and nonischemic cardiomyopathy, with primary and secondary implant indications.
- Patients will be recruited when being evaluated for defibrillator implant.
- Inclusion criteria: age >18 with ability to give informed consent, who are expected to live more than one year, with indication for defibrillator implant and who are not pacemaker dependent. Patients will have either ischemic or nonischemic cardiomyopathy.
- Exclusion criteria: age <18, inability to give informed consent, or life expectancy less than one year, pacemaker dependence, or use of preexisting lead for sensing, any condition which would preclude ICD testing at the end of the implant. Patients who are undergoing upgrade to an ICD from a pacemaker will also be excluded. In addition, patients with inherited arrhythmias or ion channel related arrhythmias will be excluded from the study.
- Withdrawal criteria: inability to implant device, implant lead at the RV apex, or make follow up appointment (living out of state), patient death at time of implant, elevated DFT (<10 J margin between DFT and maximum output of the device) requiring additional procedures, subcutaneous array etc.
- Duration of patient participation would be one month.
- Duration of study would be one year.
Procedures:
- Procedures to be followed would include screening of all eligible patients undergoing implant of a Medtronic defibrillator for either primary or secondary prevention. If patients meet inclusion criteria they would then undergo informed consent and if willing be enrolled in the study. Defibrillator implant and testing would be performed as per usual practice of the implanting physician. The RV lead will be placed at the RV apex as is usual for regular implantation of devices. However, if a lead is placed elsewhere, the patient will need to be withdrawn from the study.
- When VF induction is performed, sensing configuration would be tested in a randomized fashion, unblinded to the operator. The untested configuration would then be tested during second VF induction. Both tests would be performed at a sensitivity setting of 1.2mV, with a number of intervals to detection (NID) of 24/32. Final programming polarity will be left at the initially tested polarity (first DFT test), unless the operator sees a need to program differently for patient safety reasons.
- Medtronic defibrillators with both sensing configurations available will be used. Data collection will be performed by Dr. Tolat, Dr. Berns, Dr. Lippman, Dr. Dell'Orfano, and the study coordinator involved with the study. A data collection form and spreadsheet will be kept for use when collecting data for analysis. Follow up will be performed at one month post implant in the office.
Risk Analysis:
- Anticipated risks are no more than that anticipated with usual ICD implant. To date, usual implant includes induction of VF with analysis of sensing in VF and evaluation of defibrillation threshold by delivery of shock.
- There is no expected increased exposure to risk by performing this study.
- Potential benefits would include gathering additional information on sensing in VF in both configurations instead of performing the two sensing tests in one configuration. This may directly benefit the patient by allowing for reprogramming defibrillator without bringing the patient back to the hospital for further testing.
Data Analysis:
- Data collection will include patient information kept in a database with name kept confidential. Patients will only be identified by number in keeping with privacy laws and practice. In addition to usual patient characteristics, data variables to be collected in both configurations will include: R wave amplitude in sinus rhythm, time to detection in VF, total episode duration (time to Vfib detection and charge delivered), number of "drop outs" (undersensing) in VF, and follow up R wave amplitude in one month.
- Statistical Methods will compare bipolar sensing configuration to the extended bipolar configuration at baseline, sensing in VF (as measured by "drop out", time to detection), and follow up amplitude of the R wave at one month.
- The current expected sample size with this pilot study is 30 patients. This may require reevaluation depending on results at the time of interim analysis.
- Keywords
- ischemic cardiomyopathy, nonischemic cardiomyopathy, implant, bipolar sensing, extended bipolar sensing
- Medical subject headings
- Ischemia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
| Study group | Role | What they receive |
|---|---|---|
| cardiomyopathy, with implant indications | 30-50 volunteers age >18, male and female with ability to give informed consent, who are expected to live more than one year, with indication for defibrillator implant and who are not pacemaker dependent. |
What is being measured
The primary outcome is the main question the study is designed to answer.
Duration of sensing (time to detection) in VF at the time of implant.
Measured: At implant
Secondary outcomes (1)
Sensing in sinus rhythm at one month
Measured: One month post implant
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted15 Dec 2009 (estimated)
- Study startDec 2009
- Primary completionJul 2011
- Study completionJul 2011
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Ischemic and Nonischemic Cardiomyopathy, With Primary and Secondary Implant IndicationsStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 50 participants (actual)
Sponsor and investigators
- Lead sponsor
- Trinity Health Of New England
- Sponsor type
- University, hospital or other
- Collaborators
- Medtronic
- Responsible party
- Sponsor
- Investigators
- Aneesh Tolat, MD, Principal investigator, Attending Cardiac Electrophysiologist, St Francis Hospital and Medical Center
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01032577
- Sponsor's protocol ID
- 10-01-005-E
- Acronym
- PropR
- Status last verified
- Feb 2012
- First submitted
- 14 Dec 2009
- Last updated
- 28 Feb 2012
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 28 Feb 2012. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Prospective Study Comparing the Sensed R Wave in Bipolar and Extended Bipolar Configurations
- ClinicalTrials.gov ID
- NCT01032577
- Acronym / sponsor ID
- PropR / 10-01-005-E
- Keywords
- ischemic cardiomyopathy, nonischemic cardiomyopathy, implant, bipolar sensing, extended bipolar sensing
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 50 participants (actual)
- Lead sponsor
- Trinity Health Of New EnglandUniversity, hospital or other
- Collaborators
- Medtronic
- Study start
- Dec 2009
- Primary completion
- Jul 2011 (actual)
- Study completion
- Jul 2011 (actual)
- First posted
- 15 Dec 2009 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The PropR study will evaluate sensing during ventricular fibrillation (VF) in both bipolar and extended bipolar configurations, in order to evaluate if both can be used interchangeably in caring for patients. In addition, follow up evaluation of R wave amplitude over time would allow us to determine whether one configuration is more likely to be associated with change. This understanding would be important in selecting the proper configuration at the time of implant.
Detailed description
Hypothesis:
Sensing in bipolar and extended bipolar configurations are the same. However, sensing in bipolar over time is more likely to decrease when compared to extended bipolar.
Objectives:
- To compare bipolar sensing and extended bipolar sensing in VF.
- Compare sensing in bipolar and extended bipolar over time.
Methods:
- This study will be a randomized comparison of bipolar and extended bipolar sensing. As per usual standard of care, at the end of ICD implantation two sensing tests in VF will be performed. Patients will be randomized to sensing in VF through the device. Each patient will undergo testing in one randomized configuration followed by a second test in the other configuration. After testing at the time of implant, each patient will be seen at one month in follow up. Sensing of each configuration will be reevaluated at that time in sinus rhythm.
- Each patient will serve as their own control, as data for sensing in both configurations will be obtained in VF at the time of implant. During testing both signals types will be recorded simultaneously through the ICD. The primary endpoint will be duration of sensing (time to detection) in VF at the time of implant.
- The secondary endpoint will be sensing in sinus rhythm at one month.
- The patient population will include approximately 30-50 volunteers age >18, male and female, both ischemic and nonischemic cardiomyopathy, with primary and secondary implant indications.
- Patients will be recruited when being evaluated for defibrillator implant.
- Inclusion criteria: age >18 with ability to give informed consent, who are expected to live more than one year, with indication for defibrillator implant and who are not pacemaker dependent. Patients will have either ischemic or nonischemic cardiomyopathy.
- Exclusion criteria: age <18, inability to give informed consent, or life expectancy less than one year, pacemaker dependence, or use of preexisting lead for sensing, any condition which would preclude ICD testing at the end of the implant. Patients who are undergoing upgrade to an ICD from a pacemaker will also be excluded. In addition, patients with inherited arrhythmias or ion channel related arrhythmias will be excluded from the study.
- Withdrawal criteria: inability to implant device, implant lead at the RV apex, or make follow up appointment (living out of state), patient death at time of implant, elevated DFT (<10 J margin between DFT and maximum output of the device) requiring additional procedures, subcutaneous array etc.
- Duration of patient participation would be one month.
- Duration of study would be one year.
Procedures:
- Procedures to be followed would include screening of all eligible patients undergoing implant of a Medtronic defibrillator for either primary or secondary prevention. If patients meet inclusion criteria they would then undergo informed consent and if willing be enrolled in the study. Defibrillator implant and testing would be performed as per usual practice of the implanting physician. The RV lead will be placed at the RV apex as is usual for regular implantation of devices. However, if a lead is placed elsewhere, the patient will need to be withdrawn from the study.
- When VF induction is performed, sensing configuration would be tested in a randomized fashion, unblinded to the operator. The untested configuration would then be tested during second VF induction. Both tests would be performed at a sensitivity setting of 1.2mV, with a number of intervals to detection (NID) of 24/32. Final programming polarity will be left at the initially tested polarity (first DFT test), unless the operator sees a need to program differently for patient safety reasons.
- Medtronic defibrillators with both sensing configurations available will be used. Data collection will be performed by Dr. Tolat, Dr. Berns, Dr. Lippman, Dr. Dell'Orfano, and the study coordinator involved with the study. A data collection form and spreadsheet will be kept for use when collecting data for analysis. Follow up will be performed at one month post implant in the office.
Risk Analysis:
- Anticipated risks are no more than that anticipated with usual ICD implant. To date, usual implant includes induction of VF with analysis of sensing in VF and evaluation of defibrillation threshold by delivery of shock.
- There is no expected increased exposure to risk by performing this study.
- Potential benefits would include gathering additional information on sensing in VF in both configurations instead of performing the two sensing tests in one configuration. This may directly benefit the patient by allowing for reprogramming defibrillator without bringing the patient back to the hospital for further testing.
Data Analysis:
- Data collection will include patient information kept in a database with name kept confidential. Patients will only be identified by number in keeping with privacy laws and practice. In addition to usual patient characteristics, data variables to be collected in both configurations will include: R wave amplitude in sinus rhythm, time to detection in VF, total episode duration (time to Vfib detection and charge delivered), number of "drop outs" (undersensing) in VF, and follow up R wave amplitude in one month.
- Statistical Methods will compare bipolar sensing configuration to the extended bipolar configuration at baseline, sensing in VF (as measured by "drop out", time to detection), and follow up amplitude of the R wave at one month.
- The current expected sample size with this pilot study is 30 patients. This may require reevaluation depending on results at the time of interim analysis.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| cardiomyopathy, with implant indications | – | –30-50 volunteers age >18, male and female with ability to give informed consent, who are expected to live more than one year, with indication for defibrillator implant and who are not pacemaker dependent. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- The patient population will include approximately 30-50 volunteers age >18, male and female, both ischemic and nonischemic cardiomyopathy, with primary and secondary implant indications.
Key inclusion criteria (5 listed)
- age > 18 with ability to give informed consent,
- patients who are expected to live more than one year,
- patients with indication for defibrillator implant,
- patients who are not pacemaker dependent,
- patients with either ischemic or nonischemic cardiomyopathy.
Key exclusion criteria (7 listed)
- age < 18,
- inability to give informed consent,
- life expectancy less than one year,
- pacemaker dependence, or use of preexisting lead for sensing,
- any condition which would preclude ICD testing at the end of the implant,
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
Duration of sensing (time to detection) in VF at the time of implant.
Time frame: At implant
1 secondary outcome
Sensing in sinus rhythm at one month
Time frame: One month post implant
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 28 Feb 2012.
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Aneesh Tolat, MD principal investigator
Attending Cardiac Electrophysiologist, St Francis Hospital and Medical Center
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Ischemic and Nonischemic Cardiomyopathy, With Primary and Secondary Implant Indications, run by Trinity Health Of New England at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 28 Feb 2012. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Duration of sensing (time to detection) in VF at the time of implant. (time frame: At implant). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Feb 2012.