The Reduction of Aspiration Rate in Intubated PatientsNCT01058928

Effects of Tracheal Tube Size on Pulmonary Aspiration

An observational study of The Reduction of Aspiration Rate in Intubated Patients, run by Seoul National University Bundang Hospital at 1 site in South Korea.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Fluid leak around the cuff is minimized when the endotracheal tube size is small relative to the size of the trachea. In the current study, the investigators assess the influence of different HVLP endotracheal tube size on fluid leakage around the cuff in a benchtop model and in anesthetized patients. Read more about this study

Who is it for?
Ages 20 to 65 years, men only
What is being tested?
Observation of fluid leakage around tracheal tube cuffs
How many people
36 participants
Where
1 siteSouth Korea
Study dates
Feb 2010to Oct 2010
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 to 65 years
  • Men only
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients,scheduled for elective cardiac surgery under general anesthesia

Who may be able to join

  • Male patients, aged 20-65 yr scheduled for elective cardiac surgery under general anesthesia

Who cannot join

  • Patients with an upper airway and vocal cord disease, pneumonia before surgery, a history of tracheostomy and tracheal stenosis.

Trial locations and contacts

1 site in 1 country.

Jin-Young Hwang, M.D. contact

82-16-746-4750

mistyblue15@naver.com

South Korea1 site
  • Seoul National University Bundang Hospital

    Gyeonggi-do, 463-707

Other trials in South Korea

About this study

Official title: Effects of Tracheal Tube Size on Pulmonary Aspiration Different Endotracheal Tube Size Influences Pulmonary Aspiration

Fluid leak around the cuff is minimized when the endotracheal tube size is small relative to the size of the trachea. In the current study, the investigators assess the influence of different HVLP endotracheal tube size on fluid leakage around the cuff in a benchtop model and in anesthetized patients.

Read the detailed description

The use of a high-volume and low-pressure (HVLP) endotracheal cuff has reduced the cuff-induced tracheal damage because the cuff conforms passively to tracheal contours as it expands during inflation and the cuff inflation pressure is assumed to be equal to cuff-to-trachea pressure. However, longitudinal folds of a HVLP cuff occur on inflation within the trachea, as the diameter of the cuff is greater than that of the trachea, and these folds provide channels for an aspiration or gas leakage.

Silent aspiration of upper airway secretions has been reported in patients undergoing general anesthesia and in the intensive care unit (ICU). A previous study reported the 83% aspiration of subglottic dye detected by bronchoscopy in anesthetized patients, and other study of intubated patients with HVLP cuffs in the ICU showed 87% aspiration rate.

Intubation-related (ventilator associated pneumonia) pneumonia is a leading cause of prolongation of hospital stay, mortality and morbidity during the postoperative period and in the ICU. Therefore, it is important to achieve a better seal around the cuff without tracheal damage, which would reduce the incidence of pneumonia in intubated patients.

A previous benchtop study demonstrated that the leak around the cuff is minimized when the endotracheal tube size is small relative to the size of the trachea. In the current study, we assess the influence of different HVLP endotracheal tube size on fluid leakage around the cuff in a benchtop model and in anesthetized patients.

Being tested
Observation of fluid leakage around tracheal tube cuffs
Keywords
Tracheal tube, Size

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Observation of fluid leakage around tracheal tube cuffsOther

    One milliliter of Evans blue diluted in 3.5 mL of saline solution is carefully instilled on the top of the tracheal tube cuff. In the operating room, one hour and five hours after intubation, fiberoptic bronchoscopy was performed to detect the possible presence of blue dye in the trachea. If a blue spot was seen on the trachea caudal to the tube's tip on any occasion, leakage was confirmed and the experiment was finished.

Study groups in NCT01058928
Study groupRoleWhat they receive
Group ID 7.5Patients with a tracheal tube ID (internal diameter) 7.5 mm
Receives: Other: Observation of fluid leakage around tracheal tube cuffs
Group ID 8.0Patients with a tracheal tube ID 8.0 mm
Receives: Other: Observation of fluid leakage around tracheal tube cuffs

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Aspiration rate

    Measured: during 5 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Jan 2010 (estimated)
  2. Study startFeb 2010
  3. Primary completionAug 2010 (estimated)
  4. Study completionOct 2010 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case-control
Time perspective
Prospective
Enrolment
36 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01058928
Sponsor's protocol ID
B-0912-090-012
Status last verified
Dec 2009
First submitted
28 Jan 2010
Last updated
29 Jan 2010
Results posted
No
Data monitoring committee
Yes

Publications

  • Seegobin RD, van Hasselt GL. Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs. Br Med J (Clin Res Ed). 1984 Mar 31;288(6422):965-8. doi: 10.1136/bmj.288.6422.965.

    PubMed 6423162
  • Pavlin EG, VanNimwegan D, Hornbein TF. Failure of a high-compliance low-pressure cuff to prevent aspiration. Anesthesiology. 1975 Feb;42(2):216-9. doi: 10.1097/00000542-197502000-00019. No abstract available.

    PubMed 1115375
  • Blunt MC, Young PJ, Patil A, Haddock A. Gel lubrication of the tracheal tube cuff reduces pulmonary aspiration. Anesthesiology. 2001 Aug;95(2):377-81. doi: 10.1097/00000542-200108000-00019.

    PubMed 11506109

Questions about this trial

What is this clinical trial studying?

An observational study of The Reduction of Aspiration Rate in Intubated Patients, run by Seoul National University Bundang Hospital at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 29 Jan 2010. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Jin-Young Hwang, M.D. (82-16-746-4750, mistyblue15@naver.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Aspiration rate (time frame: during 5 hours). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01058928, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Jan 2010.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in