Distal Radius FracturesPhase 4VALCP2010NCT01103297
2.4 mm Variable Angle LCP Two-Column Volar Distal Radius
A Phase 4 study testing Variable Angle Distal Radius Plate ® (Surgery) in people with Distal Radius Fractures, run by AO Clinical Investigation and Publishing Documentation at 6 sites in 3 countries.
Trial summary
The purpose of this study is to is to evaluate the postoperative loss of reduction rate in patients with distal radius fractures treated using the 2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate ®. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Distal Radius Fractures
- What is being tested?
- Variable Angle Distal Radius Plate ® (Surgery)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 74 participants
- Where
- 6 sitesin 3 countries
- Study dates
- Jun 2010to May 2014
- Phase
- Phase 4
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patients aged ≥ 18 years
- Patients with closed, partial or complete articular distal radius fractures classified as: AO 23 B3 and AO 23 C1, C2, C3 confirmed by CT scan
- Definitive primary fracture treatment with a VA LCP DR
- The patient is willing and able to participate in the study follow-up examinations according to the protocol
- The patient is able to understand and read the local language at an elementary level
- The patient or his/her legal guardian is willing and able to give his informed consent to participate in the study
Show all 12Show fewer
- Woman must be one of the following:
- Postmenopausal defined as amenorrhea for at least 6 months before screening and a serum follicle stimulating hormone (FSH) level consistent with postmenopausal status
- Surgically sterile, (have had a hysterectomy or bilateral oophorectomy, tubal ligation, or otherwise be incapable of pregnancy)
- Abstinent (at the discretion of the investigator) or,
- If sexually active, be practicing an effective method of birth control such as hormonal prescription oral contraceptives, progesterone implants or injections, intrauterine device (IUD), a double-barrier method such as condoms, diaphragms or cervical caps with spermicidal foam, cream or gel, or male partner with a vasectomy.
- Women of childbearing potential must have a negative serum β-human chorionic gonadotropin (β-hCG) pregnancy test, or a negative urine pregnancy test at screening.
Who cannot join
- Previous ipsilateral distal radius fracture
- Other fractures of the ipsilateral side (except ulna)
- Pathologic fracture due to malignancy
- The patient suffers from a polytrauma
- The patient is affected by drug or alcohol abuse
- The patient suffers from active malignancy
Show all 10Show fewer
- Neurological and psychiatric disorders
- The patient has participated in any other device or drug related clinical trial within the previous month
- The patient is a prisoner
- Breast feeding woman
Trial locations and contacts
6 sites in 3 countries.
6 sites in 3 countries
Switzerland3 sites
Universitätsspital Basel
Basel, Basel, 4056
Luzerner Kantonsspital
Lucerne, Canton of Lucerne, 6000
Spital Zollikerberg
Zurich, 8008
Germany2 sites
Charite Berlin
Berlin
Universitätssklinikum Münster
Münster, 48149
About this study
Official title: A Prospective Multicenter Case-series of Patients Treated With the 2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate ®
The purpose of this study is to is to evaluate the postoperative loss of reduction rate in patients with distal radius fractures treated using the 2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate ®.
Read the detailed description
The treatment of choice for distal radius fractures is anatomic reduction with stable fixation. This is commonly achieved via open reduction and internal fixation with angle-stable designed locking plates using either a volar or dorsal approach. Frequent complications of tendinitis are associated with the latter approach. Palmar application of angle-stable plates reduces this problem of extensor tendon irritation; however a high incidence of fracture collapse has been documented. Currently, there are no existing locking plates that provide sufficient stability particularly for complex fractures. Insufficient fragment fixation can result in loss of reduction due to interfragmentary movement and lead to mal- or nonunion.
The Variable Angle LCP Two-Column Volar DR plate (VA LCP DR) is a novel development of the LCP Distal Radius Plate System, which is designed to treat a wide variety of distal radius fracture patterns. Because of its design (ie, low plate and screw profile, polished surface, rounded edges, various locking options), not only can the potential for tendon adhesions and soft tissue irritation be minimized, the plate can address fragments individually for each fracture type. Thus, the versatility of VA LCP facilitates the reduction and stabilization of even the most complex fractures, including those in osteoporotic bone.
This prospective case-series will evaluate the performance of the new VA LCP DR plate in the treatment of complex articular fractures of the distal radius. The primary objective of this study involves the documentation of postoperative loss of reduction; functional outcomes, quality of life and rate of complications associated with fracture fixation will also be assessed as part of the secondary study aims.
- Conditions
- Distal Radius Fractures
- Being tested
- Variable Angle Distal Radius Plate ® (Surgery)
- Keywords
- Distal radius fracture, Double row plate, Volar approach, DVR plate, Postoperative complications [MeSH]
- Medical subject headings
- Wrist Fractures
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Variable Angle Distal Radius Plate ® (Surgery)Device
Also called 2.4 Variable Angle LCP Two-Column Volar Distal Radius Plate®
Fracture reduction with distal radius plate
| Study group | Role | What they receive |
|---|---|---|
| Variable Angle Distal Radius Plate | Other | Not described Receives: Device: Variable Angle Distal Radius Plate ® (Surgery) |
What is being measured
The primary outcome is the main question the study is designed to answer.
Loss of reduction
Loss of reduction will be defined as the change in measurement* determined to 0.5 mm or 1 degree of accuracy:
*Any change in angles, length or secondary fragment displacement (ie, radial height (length), radial inclination, ulnar variance, gap, step-off, palmar tilt (inclination) / dorsal tilt, scapholunate angle, teardrop angle, and the AP distance).
Measured: over 1 year
Secondary outcomes (14)
Rate of fracture fixation complications
Measured: Baseline
Wrist function
Bilateral Range of motion (ROM)
Measured: 12 weeks
Grip strength
With Jamar dynamometer
Measured: 12 weeks
Wrist pain and disability in functional activities
Patient self-assessment of wrist function questionnaire (PRWE)
Measured: Baseline
Quality of Life
Health-related quality of life (EQ5D)
Measured: Baseline
Implantation and system feedback
Measured: Baseline
Rate of fracture fixation complications
Measured: 12 weeks
Rate of fracture fixation complications
Measured: 1 year
Wrist function
Bilateral Range of motion (ROM)
Measured: 1 year
Grip strength
With Jamar dynamometer
Measured: 1 year
Wrist pain and disability in functional activities
Patient self-assessment of wrist function questionnaire (PRWE)
Measured: 12 weeks
Wrist pain and disability in functional activities
Patient self-assessment of wrist function questionnaire (PRWE)
Measured: 1 year
Quality of Life
Health-related quality of life (EQ5D)
Measured: 12 weeks
Quality of Life
Health-related quality of life (EQ5D)
Measured: 1 year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted14 Apr 2010 (estimated)
- Study startJun 2010
- Primary completionFeb 2014
- Study completionMay 2014
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Distal Radius FracturesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 4
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 74 participants (actual)
Sponsor and investigators
- Lead sponsor
- AO Clinical Investigation and Publishing Documentation
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Jesse B Jupiter, MD, Principal investigator, Massachusetts General Hospital, Orthopaedic Surgery, Yawkey Center, Suite 2100, 55 Fruit Street, Boston, MA 02114, USAAndreas Schierz, MD, Principal investigator, Spital Zollikerberg, Unfallchirurgie, Trichtenhauserstrasse 20, CH-8125 Zollikerberg, Switzerland
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01103297
- Sponsor's protocol ID
- VALCPDR
- Acronym
- VALCP2010
- Status last verified
- Sep 2014
- First submitted
- 25 Mar 2010
- Last updated
- 19 Sep 2014
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 19 Sep 2014. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Prospective Multicenter Case-series of Patients Treated With the 2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate ®
- ClinicalTrials.gov ID
- NCT01103297
- Acronym / sponsor ID
- VALCP2010 / VALCPDR
- Conditions
- Distal Radius Fractures
- Keywords
- Distal radius fracture, Double row plate, Volar approach, DVR plate, Postoperative complications [MeSH]
- Phase
- Phase 4
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 74 participants (actual)
- Lead sponsor
- AO Clinical Investigation and Publishing DocumentationUniversity, hospital or other
- Study start
- Jun 2010
- Primary completion
- Feb 2014 (actual)
- Study completion
- May 2014 (actual)
- First posted
- 14 Apr 2010 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to is to evaluate the postoperative loss of reduction rate in patients with distal radius fractures treated using the 2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate ®.
Detailed description
The treatment of choice for distal radius fractures is anatomic reduction with stable fixation. This is commonly achieved via open reduction and internal fixation with angle-stable designed locking plates using either a volar or dorsal approach. Frequent complications of tendinitis are associated with the latter approach. Palmar application of angle-stable plates reduces this problem of extensor tendon irritation; however a high incidence of fracture collapse has been documented. Currently, there are no existing locking plates that provide sufficient stability particularly for complex fractures. Insufficient fragment fixation can result in loss of reduction due to interfragmentary movement and lead to mal- or nonunion.
The Variable Angle LCP Two-Column Volar DR plate (VA LCP DR) is a novel development of the LCP Distal Radius Plate System, which is designed to treat a wide variety of distal radius fracture patterns. Because of its design (ie, low plate and screw profile, polished surface, rounded edges, various locking options), not only can the potential for tendon adhesions and soft tissue irritation be minimized, the plate can address fragments individually for each fracture type. Thus, the versatility of VA LCP facilitates the reduction and stabilization of even the most complex fractures, including those in osteoporotic bone.
This prospective case-series will evaluate the performance of the new VA LCP DR plate in the treatment of complex articular fractures of the distal radius. The primary objective of this study involves the documentation of postoperative loss of reduction; functional outcomes, quality of life and rate of complications associated with fracture fixation will also be assessed as part of the secondary study aims.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Variable Angle Distal Radius Plate | Other | Device: Variable Angle Distal Radius Plate ® (Surgery) |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (12 listed)
- Patients aged ≥ 18 years
- Patients with closed, partial or complete articular distal radius fractures classified as: AO 23 B3 and AO 23 C1, C2, C3 confirmed by CT scan
- Definitive primary fracture treatment with a VA LCP DR
- The patient is willing and able to participate in the study follow-up examinations according to the protocol
- The patient is able to understand and read the local language at an elementary level
Key exclusion criteria (10 listed)
- Previous ipsilateral distal radius fracture
- Other fractures of the ipsilateral side (except ulna)
- Pathologic fracture due to malignancy
- The patient suffers from a polytrauma
- The patient is affected by drug or alcohol abuse
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Variable Angle Distal Radius Plate ® (Surgery)Also: 2.4 Variable Angle LCP Two-Column Volar Distal Radius Plate®Fracture reduction with distal radius plate | Device | Variable Angle Distal Radius Plate |
Primary outcome
Loss of reduction
Time frame: over 1 year
Loss of reduction will be defined as the change in measurement* determined to 0.5 mm or 1 degree of accuracy: *Any change in angles, length or secondary fragment displacement (ie, radial height (length), radial inclination, ulnar variance, gap, step-off, palmar tilt (inclination) / dorsal tilt, scapholunate angle, teardrop angle, and the AP distance).
14 secondary outcomes
Rate of fracture fixation complications
Time frame: Baseline
Wrist function
Time frame: 12 weeks
Grip strength
Time frame: 12 weeks
Wrist pain and disability in functional activities
Time frame: Baseline
Quality of Life
Time frame: Baseline
Implantation and system feedback
Time frame: Baseline
Rate of fracture fixation complications
Time frame: 12 weeks
Rate of fracture fixation complications
Time frame: 1 year
Wrist function
Time frame: 1 year
Grip strength
Time frame: 1 year
Wrist pain and disability in functional activities
Time frame: 12 weeks
Wrist pain and disability in functional activities
Time frame: 1 year
Quality of Life
Time frame: 12 weeks
Quality of Life
Time frame: 1 year
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 19 Sep 2014.
Related trials for Distal Radius Fractures
RecruitingPhase 1
Impact of Early ADL Education on Outcomes Post DRF ORIF
Distal Radius Fractures
Recruiting
Optimal Duration of Longitudinal Mechanical Traction in Displaced Radius Fractures: a Prospective Non-inferiority Study
Distal Radius Fracture
Recruiting
Home-Based Photobiomodulation Effects in the Postoperative Period of Distal Radius Fractures
Distal Radius Fracture
Not yet recruiting
X-BS Ortho Bone Graft Study
Orthopedic Disorder, Trauma Injury
Active, not recruitingPhase 4
Brachial Plexus Nerve Block Versus Haematoma Block for Closed Reduction of Distal Radius Fracture in Adults - The BLOCK Trial. A Multicentre Randomised Controlled Trial.
Distal Radius Fractures, Fracture Dislocation
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Jesse B Jupiter, MD principal investigator
Massachusetts General Hospital, Orthopaedic Surgery, Yawkey Center, Suite 2100, 55 Fruit Street, Boston, MA 02114, USA
Andreas Schierz, MD principal investigator
Spital Zollikerberg, Unfallchirurgie, Trichtenhauserstrasse 20, CH-8125 Zollikerberg, Switzerland
6 sites in 3 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 4 study testing Variable Angle Distal Radius Plate ® (Surgery) in people with Distal Radius Fractures, run by AO Clinical Investigation and Publishing Documentation at 6 sites in 3 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 12 inclusion and 10 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 19 Sep 2014. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 6 sites in Switzerland, Germany, Austria. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Loss of reduction (time frame: over 1 year). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Sep 2014.