Heart Transplant PatientsNCT01122810
Scanner and Transplant Heart Patients Protocol
A study testing Coronary scanner in people with Heart Transplant Patients, run by French Cardiology Society at 1 site in France.
Trial summary
Coronary vasculopathy remains the leading cause of decreased survival after the first year post-transplantation. It is mainly asymptomatic because of the denervation of the heart transplant. Currently, annual invasive coronary angiogram is performed to ensure the lack of coronary narrowing. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Heart Transplant Patients
- What is being tested?
- Coronary scanner
- Type of treatment
- Surgery or procedure
- How many people
- 102 participants
- Where
- 1 siteFrance
- Study dates
- Jun 2008to Nov 2010
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Transplant heart patients
- Years > 18
- Informed Content
Who cannot join
- < 18 years old
- Renal failure (Creatinine > 150 µmol/l)
- Patient in complete arrhythmia due to auricular fibrillation
- Patient with a Cardiac Basic frequency > 100 / min
- Iodine Allergy
- Patient hospitalized except the frame of the annual systematic monitoring
Show all 9Show fewer
- Pregnancy
- People unable to sign the informed content such as major under supervision
- Patients non affiliated to the social security system
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Head to Head Comparison of Multidetector Coronary Tomography and Conventional Coronary Angiogram in the Setting of Systematic Screening of Coronary Vasculopathy After Orthotopic Heart Transplantation.
Coronary vasculopathy remains the leading cause of decreased survival after the first year post-transplantation. It is mainly asymptomatic because of the denervation of the heart transplant. Currently, annual invasive coronary angiogram is performed to ensure the lack of coronary narrowing. But invasive coronary angiography caries risks of serious adverse events and some concern rise from its repetition in that population. Recent advance in coronary multidetector computed tomography (CT) may allow non invasive visualization of the coronary tree. But, it remains unknown if the encouraging data observed in native coronary artery analysis can be extrapolated to transplant heart recipients. Indeed, only very small sample size studies (20 patients) have been conducted in this particular setting. Thus, the investigators decide to assess the diagnostic accuracy of the 64-row CT and 256-row CT compared to the gold standard coronary angiogram in a larger sample size study. The practice aim of this study is to determine if the conventional invasive coronarography can be switched by the 64-row CT or the 256-row CT to assess coronary anatomy especially for the patient without any coronary artery disease (CAD) or those with CAD not suitable for percutaneous coronary intervention.
Read the detailed description
Background:
Heart transplantation is a major advance in the care of patient with terminal heart failure. But, despite the spectacular prognosis improvement obtained with this treatment, coronary vasculopathy remains the leading cause of decreased survival after the first year post-transplantation (8% of death at 1 year, 42% at 5 years). This coronary artery disease (CAD) has a particular feature involving immunological and inflammatory process, also favoured by classical risk factors in the context of immunosuppression, with rapid and diffuse involvement. Because of the denervation of the transplant heart, it remains mainly asymptomatic and let non invasive stress tests with poor accuracy for CAD screening. It explains the current use of systematic coronary angiogram to transplant heart recipient's survey.
But coronary angiogram remains an invasive technique and exposed to potential serious adverse events.
The recent advance in coronary multidetector computed tomography (CT) may allow non invasive visualization of the coronary tree. Indeed, 64-row CT has already showed its accuracy for the screening of CAD in symptomatic patient in sinus rhythm. However, they are very few studies in the setting of heart transplantation with small sample size and mainly using 16-row CT. Only two small sample size studies (20 patients each) have been conducted using 64-row CT in the setting of heart transplant recipients. None of them compared X-Ray and contrast iodine exposure.
Aim :
Our primary aim is to compare the diagnostic accuracy value of the 64-row CT and 256-row CT to the gold standard (conventional coronary angiogram) in the setting of CAD screening in a large population of heart transplant recipients (= 110 pts). We make the assumption that the sensitivity of CT is enough to allow switching the coronary angiogram by CT for the screening of asymptomatic CAD in heart transplant recipients without CAD or with CAD not suitable for revascularization.
We plan also to compare X-Ray and contrast agent exposure.
Methods :
All the transplant heart patients systematically followed in the cardiovascular and thoracic surgery service will be prospectively included. All the patients will sign the informed consent, then CT will be performed 24 H before the coronary angiogram.
multidetector coronary computed tomography : The Electrocardiogram (ECG)-gated contrast-enhanced multidetector computed tomography coronary angiography will be performed with a 64 or 256-row CT Philips, Brilliance. The contrast medium (Iomeron*, ioméprol, Bracco-Altana Pharma GmbH) mean quantity used is 80-100 ml. The CT scan parameters, adapted to the patient's weight, include 120 kV, 800mA, 0.625 mm slice thickness, 0.42-s rotation time and 0.2 pitch. To determine X-Ray exposure, Dose Length Product (Gycm) will be measured.
After the scan, the reconstruction will be performed at 40 and 75 % of the cycle using ECG gating. Additional reconstructions at different phase can be performed in case of coronary calcification or motion artefacts.
A semi quantitative analyse (N=normal, I=intermediate, S=stenosis) of coronary narrowing will be performed blindly to coronary angiogram results by two experienced radiologists. The CT quality will be determined using a quality scale (scale from 1 to 5).
A Calcification score will also be determined. A segment analyse will be performed according to AHA classification (17 segments model). Only more than 1.5 mm diameter vessel segments will be analysed.
Coronary angiogram :
According to good practice, patients will receive 0.9 % saline serum intravenously at a dose of 1000 ml per 12 H before and 1000 ml per 12 H after contrast medium injection.
Coronary angiogram will be performed according to standard protocol, using radial access with 4 or 5 French sheath under continuous invasive survey of blood pressure and ECG monitoring. The contrast medium quantity used (Hexabrix*, sodium and méglumine ioxaglate, Guerbet) as the X-Ray dose era product (Gy.cm²) will be measured.
Quantitative coronary analysis will be performed by two experienced interventional cardiologists blind to the CT results. Significant stenosis is defined by a > 50% vessel narrowing.
Serum creatinine will be controlled the day before, the day after and 72 H after the coronary angiogram.
Statistical analysis :
Comparison of the two techniques will be done by segments, by artery and by patients with determination of the sensitivity, specificity, positive and negative predictive value of CT for the screening of significant coronary stenosis (> 50%). Statistical analysis will be made with Statview 5.0.
Ethical comity :
All the patient receive and sign an informed consent. The ethical comity (CPP Ile-de-France VI) approves the protocol and the French Society of Cardiology supported the study.
Expected Calendar :
We plan to perform the CT during systematic annual hospitalisation for invasive coronary angiogram. In the cardiovascular department, approximately 8 patients benefit from coronary angiogram per week. Thus we plan to include 110 patients within 30 months, taking in account the exclusion criteria and the availability of both techniques.
- Conditions
- Heart Transplant Patients
- Being tested
- Coronary scanner
- Keywords
- Diagnostic accuracy of coronary angiography, Transplant heart patients, X-Ray and contrast agent exposure, Coronary stenosis
- Medical subject headings
- Coronary Stenosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Coronary scannerProcedure or surgery
Also called 64 ou 256 row coronary computed tomography
The ECG-gated contrast-enhanced multidetector computed tomography coronary angiography will be performed with a 64 or 256-row CT Philips, Brilliance. The contrast medium mean quantity used is 80-100 ml. The CT scan parameters, adapted to the patient's weight, include 120 kV, 800mA, 0.625 mm slice thickness, 0.42-s rotation time and 0.2 pitch. To determine X-Ray exposure, Dose Length Product (Gycm) will be measured. Reconstruction will be performed at 40 and 75 % of the cycle using ECG gating. A semi quantitative analyse of coronary narrowing will be performed blindly to coronary angiogram results by two experienced radiologists. The CT quality will be determined using a quality scale from 1 to 5. A Calcification score will also be determined. A segment analyse will be performed according to AHA classification. Only more than 1.5 mm diameter vessel segments will be analysed.
What is being measured
The primary outcome is the main question the study is designed to answer.
sensitivity of CT : Frequency of stenosis diagnosed by CT in comparison with frequency of stenosis diagnosed by coronarography
Measured: Day 1
Secondary outcomes (2)
specificity, positive predictive value, negative predictive value of CT
Measured: Day 1
X-Ray and contrast agent exposure
Measured: Day 1
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 May 2010 (estimated)
- Study startJun 2008
- Primary completionNov 2010
- Study completionNov 2010
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Heart Transplant PatientsStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Non-randomised
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 102 participants (actual)
Sponsor and investigators
- Lead sponsor
- French Cardiology Society
- Sponsor type
- University, hospital or other
- Collaborators
- French Federation of Cardiology
- Investigators
- Olivier Barthelemy, MD, Principal investigator, Pitié-Salpêtrière Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01122810
- Sponsor's protocol ID
- 2007-07
- Status last verified
- Mar 2011
- First submitted
- 2 Mar 2010
- Last updated
- 9 Mar 2011
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 9 Mar 2011. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Head to Head Comparison of Multidetector Coronary Tomography and Conventional Coronary Angiogram in the Setting of Systematic Screening of Coronary Vasculopathy After Orthotopic Heart Transplantation.
- ClinicalTrials.gov ID
- NCT01122810
- Acronym / sponsor ID
- 2007-07
- Conditions
- Heart Transplant Patients
- Keywords
- Diagnostic accuracy of coronary angiography, Transplant heart patients, X-Ray and contrast agent exposure, Coronary stenosis
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 102 participants (actual)
- Lead sponsor
- French Cardiology SocietyUniversity, hospital or other
- Collaborators
- French Federation of Cardiology
- Study start
- Jun 2008
- Primary completion
- Nov 2010 (actual)
- Study completion
- Nov 2010 (actual)
- First posted
- 13 May 2010 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Coronary vasculopathy remains the leading cause of decreased survival after the first year post-transplantation. It is mainly asymptomatic because of the denervation of the heart transplant. Currently, annual invasive coronary angiogram is performed to ensure the lack of coronary narrowing. But invasive coronary angiography caries risks of serious adverse events and some concern rise from its repetition in that population. Recent advance in coronary multidetector computed tomography (CT) may allow non invasive visualization of the coronary tree. But, it remains unknown if the encouraging data observed in native coronary artery analysis can be extrapolated to transplant heart recipients. Indeed, only very small sample size studies (20 patients) have been conducted in this particular setting. Thus, the investigators decide to assess the diagnostic accuracy of the 64-row CT and 256-row CT compared to the gold standard coronary angiogram in a larger sample size study. The practice aim of this study is to determine if the conventional invasive coronarography can be switched by the 64-row CT or the 256-row CT to assess coronary anatomy especially for the patient without any coronary artery disease (CAD) or those with CAD not suitable for percutaneous coronary intervention.
Detailed description
Background:
Heart transplantation is a major advance in the care of patient with terminal heart failure. But, despite the spectacular prognosis improvement obtained with this treatment, coronary vasculopathy remains the leading cause of decreased survival after the first year post-transplantation (8% of death at 1 year, 42% at 5 years). This coronary artery disease (CAD) has a particular feature involving immunological and inflammatory process, also favoured by classical risk factors in the context of immunosuppression, with rapid and diffuse involvement. Because of the denervation of the transplant heart, it remains mainly asymptomatic and let non invasive stress tests with poor accuracy for CAD screening. It explains the current use of systematic coronary angiogram to transplant heart recipient's survey.
But coronary angiogram remains an invasive technique and exposed to potential serious adverse events.
The recent advance in coronary multidetector computed tomography (CT) may allow non invasive visualization of the coronary tree. Indeed, 64-row CT has already showed its accuracy for the screening of CAD in symptomatic patient in sinus rhythm. However, they are very few studies in the setting of heart transplantation with small sample size and mainly using 16-row CT. Only two small sample size studies (20 patients each) have been conducted using 64-row CT in the setting of heart transplant recipients. None of them compared X-Ray and contrast iodine exposure.
Aim :
Our primary aim is to compare the diagnostic accuracy value of the 64-row CT and 256-row CT to the gold standard (conventional coronary angiogram) in the setting of CAD screening in a large population of heart transplant recipients (= 110 pts). We make the assumption that the sensitivity of CT is enough to allow switching the coronary angiogram by CT for the screening of asymptomatic CAD in heart transplant recipients without CAD or with CAD not suitable for revascularization.
We plan also to compare X-Ray and contrast agent exposure.
Methods :
All the transplant heart patients systematically followed in the cardiovascular and thoracic surgery service will be prospectively included. All the patients will sign the informed consent, then CT will be performed 24 H before the coronary angiogram.
multidetector coronary computed tomography : The Electrocardiogram (ECG)-gated contrast-enhanced multidetector computed tomography coronary angiography will be performed with a 64 or 256-row CT Philips, Brilliance. The contrast medium (Iomeron*, ioméprol, Bracco-Altana Pharma GmbH) mean quantity used is 80-100 ml. The CT scan parameters, adapted to the patient's weight, include 120 kV, 800mA, 0.625 mm slice thickness, 0.42-s rotation time and 0.2 pitch. To determine X-Ray exposure, Dose Length Product (Gycm) will be measured.
After the scan, the reconstruction will be performed at 40 and 75 % of the cycle using ECG gating. Additional reconstructions at different phase can be performed in case of coronary calcification or motion artefacts.
A semi quantitative analyse (N=normal, I=intermediate, S=stenosis) of coronary narrowing will be performed blindly to coronary angiogram results by two experienced radiologists. The CT quality will be determined using a quality scale (scale from 1 to 5).
A Calcification score will also be determined. A segment analyse will be performed according to AHA classification (17 segments model). Only more than 1.5 mm diameter vessel segments will be analysed.
Coronary angiogram :
According to good practice, patients will receive 0.9 % saline serum intravenously at a dose of 1000 ml per 12 H before and 1000 ml per 12 H after contrast medium injection.
Coronary angiogram will be performed according to standard protocol, using radial access with 4 or 5 French sheath under continuous invasive survey of blood pressure and ECG monitoring. The contrast medium quantity used (Hexabrix*, sodium and méglumine ioxaglate, Guerbet) as the X-Ray dose era product (Gy.cm²) will be measured.
Quantitative coronary analysis will be performed by two experienced interventional cardiologists blind to the CT results. Significant stenosis is defined by a > 50% vessel narrowing.
Serum creatinine will be controlled the day before, the day after and 72 H after the coronary angiogram.
Statistical analysis :
Comparison of the two techniques will be done by segments, by artery and by patients with determination of the sensitivity, specificity, positive and negative predictive value of CT for the screening of significant coronary stenosis (> 50%). Statistical analysis will be made with Statview 5.0.
Ethical comity :
All the patient receive and sign an informed consent. The ethical comity (CPP Ile-de-France VI) approves the protocol and the French Society of Cardiology supported the study.
Expected Calendar :
We plan to perform the CT during systematic annual hospitalisation for invasive coronary angiogram. In the cardiovascular department, approximately 8 patients benefit from coronary angiogram per week. Thus we plan to include 110 patients within 30 months, taking in account the exclusion criteria and the availability of both techniques.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Non-randomised
- Intervention model
- Single group
- Masking
- None (open label)
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Transplant heart patients
- Years > 18
- Informed Content
Key exclusion criteria (9 listed)
- < 18 years old
- Renal failure (Creatinine > 150 µmol/l)
- Patient in complete arrhythmia due to auricular fibrillation
- Patient with a Cardiac Basic frequency > 100 / min
- Iodine Allergy
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Coronary scannerAlso: 64 ou 256 row coronary computed tomographyThe ECG-gated contrast-enhanced multidetector computed tomography coronary angiography will be performed with a 64 or 256-row CT Philips, Brilliance. The contrast medium mean quantity used is 80-100 ml. The CT scan parameters, adapted to the patient's weight, include 120 kV, 800mA, 0.625 mm slice thickness, 0.42-s rotation time and 0.2 pitch. To determine X-Ray exposure, Dose Length Product (Gycm) will be measured. Reconstruction will be performed at 40 and 75 % of the cycle using ECG gating. A semi quantitative analyse of coronary narrowing will be performed blindly to coronary angiogram results by two experienced radiologists. The CT quality will be determined using a quality scale from 1 to 5. A Calcification score will also be determined. A segment analyse will be performed according to AHA classification. Only more than 1.5 mm diameter vessel segments will be analysed. | Procedure or surgery | – |
Primary outcome
sensitivity of CT : Frequency of stenosis diagnosed by CT in comparison with frequency of stenosis diagnosed by coronarography
Time frame: Day 1
2 secondary outcomes
specificity, positive predictive value, negative predictive value of CT
Time frame: Day 1
X-Ray and contrast agent exposure
Time frame: Day 1
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 Mar 2011.
Related trials for Heart Transplant Patients
Not yet recruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
Enrolling by invitation
Feasibility of Physical Prehabilitation for High-Risk Patients Undergoing Cardiac Surgery Via Sternotomy
Prehabilitation, Cardiac Surgery
RecruitingObservational study
CytOSorb TreatMent Of Critically Ill PatientS Registry
Septic Shock, Acute Respiratory Distress Syndrome
Active, not recruiting
Oral Water Ingestion in Heart Transplant Patients
Blood Pressure, Cardiac Transplantation
Not yet recruiting
Serratus Anterior Plane Block for Recovery After Minimally Invasive CABG
Postoperative Pain Control, Coronary Artery Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Olivier Barthelemy, MD principal investigator
Pitié-Salpêtrière Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Coronary scanner in people with Heart Transplant Patients, run by French Cardiology Society at 1 site in France.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 9 Mar 2011. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
sensitivity of CT : Frequency of stenosis diagnosed by CT in comparison with frequency of stenosis diagnosed by coronarography (time frame: Day 1). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Mar 2011.