Virtual Ports, Ltd., has developed a lens cleaning device, EndoClear, which is attached to the internal abdominal wall at the beginning of a surgical case and remains in position until completion of the surgery, enabling the surgeon to clean the camera lens without removing it from the abdominal cavity. Read more about this study
- Who is it for?
- Ages 18 to 85 years
- Conditions the study is for
- Laparoscopic Abdominal Surgery
- What is being tested?
- EndoClear Lens Cleaning Device
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 20 participants
- Where
- 1 siteUnited States
- Study dates
- Mar 2009to Mar 2010
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 85 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- >18 years of age
- Patients undergoing laparoscopic abdominal surgery
Who cannot join
- Patients with known coagulopathy or bleeding tendencies
- Intra-abdominal abscesses
- Pregnancy
- Non-elective laparoscopic surgery.
Trial locations and contacts
1 site in 1 country.
About this study
Virtual Ports, Ltd., has developed a lens cleaning device, EndoClear, which is attached to the internal abdominal wall at the beginning of a surgical case and remains in position until completion of the surgery, enabling the surgeon to clean the camera lens without removing it from the abdominal cavity. The purpose of this study is to evaluate the efficacy and safety of using the EndoClear device as a laparoscopic lens cleaning device.
Read the detailed description
The ability to perform laparoscopic surgery safely and effectively depends on the uninterrupted progression of the operation. Any interruptions to the normal workflow of the procedure threatens to cause distraction which in the least can lengthen the operative time leading to increased hospital operating costs and exposing the patient to unnecessary excess anesthesia and associated risks. At worst, interruptions can cause errors in judgment and/or technique resulting in injury to the patient.
Interruptions in the operating room can take many forms, from conversations to equipment malfunction. The goal of this study is to focus on one particular type of interruption unique to laparoscopic surgery - lens cleaning. It is quite common during the course of the procedure for the laparoscopic scope lens to become obscured by bodily fluids or steam from cautery devices. This necessitates having to remove the camera from the patient, cleaning it outside of the body, applying de-fog solution, reinserting it into the body, and having to reacquire the original camera position and image. This can be quite dangerous particularly in the middle of operative step, such as when there is ongoing bleeding, or when there are sharp or hot instruments within the body. Pilot data from own group demonstrates that the camera may have to be cleaned up to 20 times during a case adding upwards of 10-15 minutes to an operation.
- Conditions
- Laparoscopic Abdominal Surgery
- Being tested
- EndoClear Lens Cleaning Device
- Keywords
- Laparoscopic, EndoClear, Lens Cleaning Device
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
EndoClear Lens Cleaning DeviceDevice
Also called Virtual Ports, Ltd
EndoClear Lens Cleaning Device is used during a laparoscopic abdominal surgery.
| Study group | Role | What they receive |
|---|---|---|
| EndoClear used | Active comparator | The EndoClear device is used during a laparoscopic abdominal surgery. Receives: Device: EndoClear Lens Cleaning Device |
| Control | No intervention | EndoClear Lens Cleaning Device not used during a laparoscopic abdominal surgery. |
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted9 Sep 2010 (estimated)
- Study startMar 2009
- Primary completionMar 2010
- Study completionMar 2010
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Laparoscopic Abdominal SurgeryStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Supportive care
- Allocation
- Randomised
- Intervention model
- Single group
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 20 participants (actual)
Sponsor and investigators
- Lead sponsor
- The Oregon Clinic
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Lee Swanstrom, The Oregon Clinic
- Investigators
- Lee L Swanstrom, MD, Principal investigator, The Oregon Clinic
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01197222
- Sponsor's protocol ID
- 940
- Status last verified
- Aug 2019
- First submitted
- 8 Sep 2010
- Last updated
- 3 Sep 2019
- Results posted
- No
- Data monitoring committee
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 3 Sep 2019. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of Safety and Efficacy of Using EndoClear-Endoscopic Lens Cleaning Device
- ClinicalTrials.gov ID
- NCT01197222
- Acronym / sponsor ID
- 940
- Conditions
- Laparoscopic Abdominal Surgery
- Keywords
- Laparoscopic, EndoClear, Lens Cleaning Device
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 20 participants (actual)
- Lead sponsor
- The Oregon ClinicUniversity, hospital or other
- Study start
- Mar 2009
- Primary completion
- Mar 2010 (actual)
- Study completion
- Mar 2010 (actual)
- First posted
- 9 Sep 2010 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Virtual Ports, Ltd., has developed a lens cleaning device, EndoClear, which is attached to the internal abdominal wall at the beginning of a surgical case and remains in position until completion of the surgery, enabling the surgeon to clean the camera lens without removing it from the abdominal cavity. The purpose of this study is to evaluate the efficacy and safety of using the EndoClear device as a laparoscopic lens cleaning device.
Detailed description
The ability to perform laparoscopic surgery safely and effectively depends on the uninterrupted progression of the operation. Any interruptions to the normal workflow of the procedure threatens to cause distraction which in the least can lengthen the operative time leading to increased hospital operating costs and exposing the patient to unnecessary excess anesthesia and associated risks. At worst, interruptions can cause errors in judgment and/or technique resulting in injury to the patient.
Interruptions in the operating room can take many forms, from conversations to equipment malfunction. The goal of this study is to focus on one particular type of interruption unique to laparoscopic surgery - lens cleaning. It is quite common during the course of the procedure for the laparoscopic scope lens to become obscured by bodily fluids or steam from cautery devices. This necessitates having to remove the camera from the patient, cleaning it outside of the body, applying de-fog solution, reinserting it into the body, and having to reacquire the original camera position and image. This can be quite dangerous particularly in the middle of operative step, such as when there is ongoing bleeding, or when there are sharp or hot instruments within the body. Pilot data from own group demonstrates that the camera may have to be cleaned up to 20 times during a case adding upwards of 10-15 minutes to an operation.
Study design
- Primary purpose
- Supportive care
- Allocation
- Randomised
- Intervention model
- Single group
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| EndoClear used | Active comparator | Device: EndoClear Lens Cleaning DeviceThe EndoClear device is used during a laparoscopic abdominal surgery. |
| Control | No intervention | –EndoClear Lens Cleaning Device not used during a laparoscopic abdominal surgery. |
Who may qualify
- Ages
- 18 to 85 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- >18 years of age
- Patients undergoing laparoscopic abdominal surgery
Key exclusion criteria (4 listed)
- Patients with known coagulopathy or bleeding tendencies
- Intra-abdominal abscesses
- Pregnancy
- Non-elective laparoscopic surgery.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| EndoClear Lens Cleaning DeviceAlso: Virtual Ports, LtdEndoClear Lens Cleaning Device is used during a laparoscopic abdominal surgery. | Device | EndoClear used |
Primary outcome
Not reported in the source record.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 3 Sep 2019.
Related trials for Laparoscopic Abdominal Surgery
Recruiting
Tramadol Versus Morphine for Postoperative Pain Relief Following Laparoscopic Abdominal Surgery
Multimodal Analgesia, Tramadol
Not yet recruiting
Effect of Laryngeal Mask Airway vs Endotracheal Tube on Hypothermia in Laparoscopic Hernia Surgery
Perioperative Hypothermia, Hernia, Inguinal
Enrolling by invitationObservational study
Intestinal Obstruction Surgery. Acute Abdominal Pathology. №9:05/05/2026
Small Bowel Adhesion, Obstruction Bowel
Recruiting
The Impact of a Dexmedetomidine Perfusion on Intraoperative Remifentanil Consumption
Dexmedetomidine, Total Intravenous Anesthesia
Recruiting
Comparison of Two Surgical Techniques for Indirect Inguinal Hernia Repair
Indirect Inguinal Hernia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Lee L Swanstrom, MD principal investigator
The Oregon Clinic
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing EndoClear Lens Cleaning Device in people with Laparoscopic Abdominal Surgery, run by The Oregon Clinic at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 3 Sep 2019. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 3 Sep 2019.