Despite recent advances in stent technology and clot reducing drug therapy, acute stent occlusion or thrombosis (ST), still occurs and can be life threatening. It has been shown that certain features of how the stent relates to the artery wall may predict ST. Read more about this study

Who is it for?
Ages 18 to 90 years
Conditions the study is for
Coronary Artery Disease
What is being tested?
Coronary Stent Cypher and Coronary stent Xience
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
40 participants
Where
1 siteUnited Kingdom
Study dates
Sep 2010to Jul 2011
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Presence of a coronary artery stenosis undergoing percutaneous coronary intervention and stenting (PCI).
  • Eligibility for drug eluting stent (DES) deployment.
  • Stable or unstable coronary syndrome presentation, including ST elevation myocardial infarction (STEMI).
  • Aged 18-90

Who cannot join

  • Contraindication to the use of a DES.
  • Target lesion located within previous stent (in stent restenosis).
  • Sustained haemodynamic instability following stent deployment (Systolic BP 90≤ mmHg or sustained ventricular arrhythmia).

Trial locations and contacts

1 site in 1 country.

United Kingdom1 site
  • Harefield Hospital

    Harefield, Middlesex, UB96JH

Other trials in United Kingdom

About this study

Official title: Comparison of Rates of Strut Malapposition Between Everolimus and Sirolimus Eluting Stents - A Randomised Optical Coherence Tomography Study

Despite recent advances in stent technology and clot reducing drug therapy, acute stent occlusion or thrombosis (ST), still occurs and can be life threatening. It has been shown that certain features of how the stent relates to the artery wall may predict ST. One such feature, so-called stent strut malapposition (SSM), can be assessed after implantation but current imaging techniques are relatively unreliable. Optical Coherence Tomography (OCT) is a newer technology that can be performed safely and easily after angioplasty and may allow the stent struts to be assessed more accurately and reliably.

This study will use OCT to examine how two different types of commonly used drug-eluting stents relate to the artery wall. The Xience V (Abbott Vascular, USA) stent has thinner struts and a more open frame than the Cypher (Cordis, USA) stent. We hypothesise therefore that the potentially more pliable structure of the Xience V stent will be associated with greater contact with the vessel wall. This may have a bearing on the relative rate of SSM, although large studies have shown the rate to be low in both the Cypher and the Xience V stent. We believe that OCT imaging of SSM and symmetry of the stent immediately after angioplasty will compliment conventional visual assessment and may identify those patients in whom further improvement of stent with a balloon is necessary.

This study will involve the random allocation of forty patients requiring coronary angioplasty to one of the Cypher or Xience V stent. The procedure will be performed in the usual manner as indicated clinically and will include imaging of the stented artery segment with OCT once the operator is satisfied with the visual result by angiography.

Being tested
Coronary Stent Cypher, Coronary stent Xience
Keywords
Percutaneous Coronary Intervention, Coronary Artery Stenosis, Acute Myocardial Infarction, Coronary Artery Stent, Optical Coherence Tomography
Medical subject headings
Coronary Artery Disease, Coronary Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Coronary Stent CypherDevice

    The angioplasty will then be performed in a usual fashion in accordance with the operator's discretion and local protocols.

  • Coronary stent XienceDevice

    The angioplasty will then be performed in a usual fashion in accordance with the operator's discretion and local protocols

Study groups in NCT01201369
Study groupRoleWhat they receive
Cypher™ StentActive comparatorParticipants in the Cypher arm will be randomised to receive a Cypher™ (Cordis, Miami Lake, USA) coronary stent
Receives: Device: Coronary Stent Cypher
Xience™ StentActive comparatorPatients in the Xience™ arm will receive a Xience™ Stent(Abbott Vascular, Santa Clara, USA.
Receives: Device: Coronary stent Xience

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Stent strut malapposition (SSM)

    SSM will be quoted as the percentage of malapposed stent struts as a proportion of the total number of struts analysed within each stent group.

    Measured: Immediate post stent deployment during the same angiographic procedure within 60 minutes

Secondary outcomes (2)
  1. Stent eccentricity index (SEI)

    This is a commonly used measure that is designed to quantify the uniformity and symmetry of the stent after it has been deployed in the coronary artery. It is calculated as the minimum diameter of the stent divided by the maximum diameter of the stent at a preset point. The mean SEI will be compared between two stent type groups.

    Measured: Immediate post stent deployment during the same angiographic procedure within 60 minutes

  2. Degree of stent embedding

    This relates to what degree, if at all, the stent strut is 'buried' within the coronary artery wall. The proportion of each strut that is buried or embedded will be calculated and then averaged for each stent group. A strut that is buried in the vessel wall for more than half its thickness will be defined as 'embedded'.

    Measured: Immediate post stent deployment during the same angiographic procedure within 60 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Sep 2010 (estimated)
  2. Study startSep 2010
  3. Primary completionJul 2011
  4. Study completionJul 2011

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
40 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01201369
Sponsor's protocol ID
ORCA-2
Acronym
ORCA-2
Status last verified
Jul 2011
First submitted
24 Aug 2010
Last updated
12 Jul 2011
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Coronary Stent Cypher and Coronary stent Xience in people with Coronary Artery Disease, run by Royal Brompton & Harefield NHS Foundation Trust at 1 site in United Kingdom.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 12 Jul 2011. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Stent strut malapposition (SSM) (time frame: Immediate post stent deployment during the same angiographic procedure within 60 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.