Advanced Heart FailureNCT01210573
Prospective Observation of Exercise Parameters in Advanced Heart Failure
An observational study of Advanced Heart Failure, run by University of Minnesota at 1 site in United States.
Trial summary
To observe and document ventilation parameters in the advanced heart failure population, through the course of illness, which often includes cardiac resynchronization therapy (CRT), left ventricular assist device (LVAD), and transplant. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Advanced Heart Failure
- What is being tested?
- adjustment of LVAD or pacemaker
- Type of treatment
- Medical device
- How many people
- 20 participants
- Where
- 1 siteUnited States
- Study dates
- Apr 2010to Sep 2014
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Study population: Patients with, or suspected to have, advanced heart failure and who meet inclusion and exclusion criteria are eligible for participation. Those who have undergone LVAD implantation, heart transplantation or are on the transplant list, and those with biventricular pacemaker who meet study criteria are also eligible for study participation. Patients diagnosed with pulmonary hypertension and therefore at risk for developing right sided heart failure may also be included.
Who may be able to join
- Age ≥18 years
- Advanced heart failure suspected or diagnosed
Who cannot join
- Inability to ambulate at least one block
- Angina that has developed or a changed in pattern/symptoms since last physician visit.
- Recent life-threatening arrhythmia or diagnosis that suggests high-risk of exacerbation of arrhythmia with exercise (catecholaminergic polymorphic ventricular tachycardia, e.g.)
- LVAD driveline infection or suspected driveline infection
- Medical activity restriction that precludes ambulation
Trial locations and contacts
1 site in 1 country.
United States1 site
Masonic Clinical Research Unit
Minneapolis, Minnesota, 55455
About this study
To observe and document ventilation parameters in the advanced heart failure population, through the course of illness, which often includes cardiac resynchronization therapy (CRT), left ventricular assist device (LVAD), and transplant. Findings from this cohort are anticipated to be of sufficient interest to the scientific community to merit publication and are likely to provide preliminary data for future hypothesis generation and subsequent prospective, randomized controlled trials.
A compact, inexpensive apparatus has recently become commercially available for performing sub-maximal exercise testing (SHAPE Medical, St Paul, MN), including gas exchange analysis and will be used in this study. This apparatus is not investigational.
Read the detailed description
Cardiopulmonary exercise testing (CPXT) has a long history in the evaluation and management of cardiovascular diseases, particularly in patients with advanced heart failure.
Cardiovascular exercise testing is a safe, well-developed, and validated method for risk stratification and objective documentation of exercise capacity in patients with severe heart failure (1,2). Recent studies have also shown that exercise testing has prognostic power for heart failure hospitalization and mortality (3,4), but limited published data are available in a large group of advanced heart failure patients, such as those with cardiac resynchronization therapy (CRT) and left ventricular assist devices (LVAD)
Advanced or suspected advanced heart failure. Typical patients screened for this study will be patients who have been referred to the University of Minnesota for evaluation for advanced heart failure options, such as cardiac transplant or mechanical circulatory support. This is a somewhat heterogeneous population, but all have been diagnosed by referring physician as having sufficiently severe heart failure to seek tertiary care. Most are anticipated to have severely depressed ejection fraction (<30% and typically <20%), but patients with preserved ejection fraction and either hypertrophy or restrictive cardiomyopathy will also be eligible. Patients pulmonary hypertension, on any therapy (other than diuretics alone), are also felt to be at high risk of developing right heart failure and may also be included. Patients who have already undergone LVAD or cardiac transplant are also considered to have advanced heart failure and are eligible to participate, regardless of the severity of their symptoms at the time of enrollment.
Healthy volunteers may be included for comparison.
This is a non-randomized, observational investigation of sub-maximal exercise ventilation parameters in patient diagnosed with, or suspected to have, advanced heart failure.
Duration of follow-up will be up to five years. Some subjects will undergo only one exercise test. Patients who present with heart failure but subsequently undergo CRT implantation, LVAD implantation, or cardiac transplant will be asked to repeat the submaximal exercise test. The timing between any of these events is unpredictable, so the duration of follow-up cannot be predicted. Subjects will be followed for change of status for up to 5 years. The total number of tests that any one person could potentially have is 5 (baseline plus one after each therapy), although we expect that most participants would not be asked to undergo more than 3 tests.
For patients without a device: Patients start at rest for 2 minutes and will wear a face mask and breathing parameters are recorded using the SHAPE-HF system (SHAPE Medical St. Paul, MN) that measures respiratory airflow and the constituent respiratory gases, oxygen and carbon dioxide. The SHAPE-HF system will continue to monitor and the patient then will start walking on a treadmill with a variable speed of 1-3 mph and a variable grade of 0-6%. The total treadmill time will be no more than 10 minutes.
For patients with a device: patients will be at rest and the adjustments of their device will be made by a study physician or device coordinator, done routinely in clinical practice. This will take up to 15 minutes and during this time; participants will wear a face mask and breathing parameters are recorded using the SHAPE-HF system (SHAPE Medical St. Paul, MN) that measures respiratory airflow and the constituent respiratory gases, oxygen and carbon dioxide. Device parameters will be returned to baseline settings following this part of the test.
Sub-maximal exercise testing approximately 30 minutes in duration will be performed on a treadmill at a slow and constant pace, the speed of the treadmill will range from 1-2 mph and the grade will range from 0-2% depending on the patient's exercise tolerance. The exercise will be split into two rounds of exercise up to 15 minutes each. Subjects may rest as long as they would like between the two tests.
The first round, participants will wear a face mask and breathing parameters are recorded using the SHAPE-HF system. (See section 13B for sample report).
In the second round, every two minutes, up to 15 minutes, participants will be asked to take 8 breaths using a breathing bag containing a standard mixture of gases (0.7% acetylene, 21% oxygen, 9% Helium and the balance of nitrogen)-this gas mixture is routinely used in pulmonary function laboratories to measure lung function and has the same amount of oxygen as room air. Acetylene mass spectroscopy is then used to measure cardiac output noninvasively.
Neither the SHAPE-HF system, nor the methods of gas exchange during exercise are investigational.
Participants who are treated with cardiac resynchronization therapy and/or ventricular assist device may have minor adjustments made to their device parameters every 2 minutes during the testing. The adjustments will be made by a study physician or device coordinator, as mentioned before, done in routine practice. Device parameters will be returned to baseline settings following the test.
- Conditions
- Advanced Heart Failure
- Being tested
- adjustment of LVAD or pacemaker
- Keywords
- Heart Failure, Heart-Assist Devices, Left Ventricular Assist Device
- Medical subject headings
- Heart Failure
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
adjustment of LVAD or pacemakerDevice
Also called HeartMate 2, HeartWare, Biventricular pacemaker
For patients without a device: Patients start at rest for 2 minutes and will wear a face mask and breathing parameters are recorded using the SHAPE-HF system (SHAPE Medical St. Paul, MN) that measures respiratory airflow and the constituent respiratory gases, oxygen and carbon dioxide.
For patients with a device: patients will be at rest and the adjustments of their device will be made by a study physician or device coordinator, done routinely in clinical practice. This will take up to 15 minutes and during this time; participants will wear a face mask and breathing parameters are recorded using the SHAPE-HF system (SHAPE Medical St. Paul, MN) that measures respiratory airflow and the constituent respiratory gases, oxygen and carbon dioxide.
| Study group | Role | What they receive |
|---|---|---|
| Device adjustment | Advanced or suspected advanced heart failure. Most are anticipated to have severely depressed ejection fraction (<30% and typically <20%), but patients with preserved ejection fraction and either hypertrophy or restrictive cardiomyopathy will also be eligible. Patients pulmonary hypertension, on any therapy (other than diuretics alone), are also felt to be at high risk of developing right heart failure and may also be included. Patients who have already undergone LVAD or cardiac transplant are also considered to have advanced heart failure and are eligible to participate, regardless of the severity of their symptoms at the time of enrollment. Receives: Device: adjustment of LVAD or pacemaker |
What is being measured
The primary outcome is the main question the study is designed to answer.
Sub-maximal exercise ventilation parameters
Observational investigation of sub-maximal exercise ventilation parameters in patient diagnosed with, or suspected to have, advanced heart failure.
Measured: Pre and Post-LVAD placement
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted28 Sep 2010 (estimated)
- Study startApr 2010
- Primary completionSep 2014
- Study completionSep 2014
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Advanced Heart FailureStudies of the same condition, open and under way.
- More trials run by University of MinnesotaThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Prospective
- Enrolment
- 20 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Minnesota
- Sponsor type
- University, hospital or other
- Collaborators
- Shape Medical Systems, Inc.
- Responsible party
- Sponsor
- Investigators
- Peter M Eckman, MD, Principal investigator, University of Minnesota
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01210573
- Sponsor's protocol ID
- 1002M77542
- Status last verified
- Dec 2014
- First submitted
- 27 Sep 2010
- Last updated
- 18 Dec 2014
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 18 Dec 2014. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Prospective Observation of Exercise Parameters in Advanced Heart Failure
- ClinicalTrials.gov ID
- NCT01210573
- Acronym / sponsor ID
- 1002M77542
- Conditions
- Advanced Heart Failure
- Keywords
- Heart Failure, Heart-Assist Devices, Left Ventricular Assist Device
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 20 participants (actual)
- Lead sponsor
- University of MinnesotaUniversity, hospital or other
- Collaborators
- Shape Medical Systems, Inc.
- Study start
- Apr 2010
- Primary completion
- Sep 2014 (actual)
- Study completion
- Sep 2014 (actual)
- First posted
- 28 Sep 2010 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
To observe and document ventilation parameters in the advanced heart failure population, through the course of illness, which often includes cardiac resynchronization therapy (CRT), left ventricular assist device (LVAD), and transplant. Findings from this cohort are anticipated to be of sufficient interest to the scientific community to merit publication and are likely to provide preliminary data for future hypothesis generation and subsequent prospective, randomized controlled trials.
A compact, inexpensive apparatus has recently become commercially available for performing sub-maximal exercise testing (SHAPE Medical, St Paul, MN), including gas exchange analysis and will be used in this study. This apparatus is not investigational.
Detailed description
Cardiopulmonary exercise testing (CPXT) has a long history in the evaluation and management of cardiovascular diseases, particularly in patients with advanced heart failure.
Cardiovascular exercise testing is a safe, well-developed, and validated method for risk stratification and objective documentation of exercise capacity in patients with severe heart failure (1,2). Recent studies have also shown that exercise testing has prognostic power for heart failure hospitalization and mortality (3,4), but limited published data are available in a large group of advanced heart failure patients, such as those with cardiac resynchronization therapy (CRT) and left ventricular assist devices (LVAD)
Advanced or suspected advanced heart failure. Typical patients screened for this study will be patients who have been referred to the University of Minnesota for evaluation for advanced heart failure options, such as cardiac transplant or mechanical circulatory support. This is a somewhat heterogeneous population, but all have been diagnosed by referring physician as having sufficiently severe heart failure to seek tertiary care. Most are anticipated to have severely depressed ejection fraction (<30% and typically <20%), but patients with preserved ejection fraction and either hypertrophy or restrictive cardiomyopathy will also be eligible. Patients pulmonary hypertension, on any therapy (other than diuretics alone), are also felt to be at high risk of developing right heart failure and may also be included. Patients who have already undergone LVAD or cardiac transplant are also considered to have advanced heart failure and are eligible to participate, regardless of the severity of their symptoms at the time of enrollment.
Healthy volunteers may be included for comparison.
This is a non-randomized, observational investigation of sub-maximal exercise ventilation parameters in patient diagnosed with, or suspected to have, advanced heart failure.
Duration of follow-up will be up to five years. Some subjects will undergo only one exercise test. Patients who present with heart failure but subsequently undergo CRT implantation, LVAD implantation, or cardiac transplant will be asked to repeat the submaximal exercise test. The timing between any of these events is unpredictable, so the duration of follow-up cannot be predicted. Subjects will be followed for change of status for up to 5 years. The total number of tests that any one person could potentially have is 5 (baseline plus one after each therapy), although we expect that most participants would not be asked to undergo more than 3 tests.
For patients without a device: Patients start at rest for 2 minutes and will wear a face mask and breathing parameters are recorded using the SHAPE-HF system (SHAPE Medical St. Paul, MN) that measures respiratory airflow and the constituent respiratory gases, oxygen and carbon dioxide. The SHAPE-HF system will continue to monitor and the patient then will start walking on a treadmill with a variable speed of 1-3 mph and a variable grade of 0-6%. The total treadmill time will be no more than 10 minutes.
For patients with a device: patients will be at rest and the adjustments of their device will be made by a study physician or device coordinator, done routinely in clinical practice. This will take up to 15 minutes and during this time; participants will wear a face mask and breathing parameters are recorded using the SHAPE-HF system (SHAPE Medical St. Paul, MN) that measures respiratory airflow and the constituent respiratory gases, oxygen and carbon dioxide. Device parameters will be returned to baseline settings following this part of the test.
Sub-maximal exercise testing approximately 30 minutes in duration will be performed on a treadmill at a slow and constant pace, the speed of the treadmill will range from 1-2 mph and the grade will range from 0-2% depending on the patient's exercise tolerance. The exercise will be split into two rounds of exercise up to 15 minutes each. Subjects may rest as long as they would like between the two tests.
The first round, participants will wear a face mask and breathing parameters are recorded using the SHAPE-HF system. (See section 13B for sample report).
In the second round, every two minutes, up to 15 minutes, participants will be asked to take 8 breaths using a breathing bag containing a standard mixture of gases (0.7% acetylene, 21% oxygen, 9% Helium and the balance of nitrogen)-this gas mixture is routinely used in pulmonary function laboratories to measure lung function and has the same amount of oxygen as room air. Acetylene mass spectroscopy is then used to measure cardiac output noninvasively.
Neither the SHAPE-HF system, nor the methods of gas exchange during exercise are investigational.
Participants who are treated with cardiac resynchronization therapy and/or ventricular assist device may have minor adjustments made to their device parameters every 2 minutes during the testing. The adjustments will be made by a study physician or device coordinator, as mentioned before, done in routine practice. Device parameters will be returned to baseline settings following the test.
Study design
- Observational model
- Case only
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Device adjustment | – | Device: adjustment of LVAD or pacemakerAdvanced or suspected advanced heart failure. Most are anticipated to have severely depressed ejection fraction (<30% and typically <20%), but patients with preserved ejection fraction and either hypertrophy or restrictive cardiomyopathy will also be eligible. Patients pulmonary hypertension, on any therapy (other than diuretics alone), are also felt to be at high risk of developing right heart failure and may also be included. Patients who have already undergone LVAD or cardiac transplant are also considered to have advanced heart failure and are eligible to participate, regardless of the severity of their symptoms at the time of enrollment. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
- Study population
- Patients with, or suspected to have, advanced heart failure and who meet inclusion and exclusion criteria are eligible for participation. Those who have undergone LVAD implantation, heart transplantation or are on the transplant list, and those with biventricular pacemaker who meet study criteria are also eligible for study participation. Patients diagnosed with pulmonary hypertension and therefore at risk for developing right sided heart failure may also be included.
Key inclusion criteria (2 listed)
- Age ≥18 years
- Advanced heart failure suspected or diagnosed
Key exclusion criteria (5 listed)
- Inability to ambulate at least one block
- Angina that has developed or a changed in pattern/symptoms since last physician visit.
- Recent life-threatening arrhythmia or diagnosis that suggests high-risk of exacerbation of arrhythmia with exercise (catecholaminergic polymorphic ventricular tachycardia, e.g.)
- LVAD driveline infection or suspected driveline infection
- Medical activity restriction that precludes ambulation
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| adjustment of LVAD or pacemakerAlso: HeartMate 2, HeartWare, Biventricular pacemakerFor patients without a device: Patients start at rest for 2 minutes and will wear a face mask and breathing parameters are recorded using the SHAPE-HF system (SHAPE Medical St. Paul, MN) that measures respiratory airflow and the constituent respiratory gases, oxygen and carbon dioxide. For patients with a device: patients will be at rest and the adjustments of their device will be made by a study physician or device coordinator, done routinely in clinical practice. This will take up to 15 minutes and during this time; participants will wear a face mask and breathing parameters are recorded using the SHAPE-HF system (SHAPE Medical St. Paul, MN) that measures respiratory airflow and the constituent respiratory gases, oxygen and carbon dioxide. | Device | Device adjustment |
Primary outcome
Sub-maximal exercise ventilation parameters
Time frame: Pre and Post-LVAD placement
Observational investigation of sub-maximal exercise ventilation parameters in patient diagnosed with, or suspected to have, advanced heart failure.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 18 Dec 2014.
Related trials for Advanced Heart Failure
Not yet recruiting
RELIEVE-HFrEF TRIAL: REducing Lung congestIon Symptoms Using the v-wavE Shunt in adVancEd Heart Failure With Reduced EF
Heart Failure and Reduced Ejection Fraction, Heart Failure Chronic
Recruiting
Trial to Evaluate Safety And Effectiveness of Mechanical Circulatory Support in Patients With Advancing Heart Failure
Heart Failure, Heart Diseases
Not yet recruiting
Inspiratory Muscle Training in Hospitalized Patients With Heart Failure Awaiting Advanced Therapies
Heart Failure, Heart Failure New York Heart Association Class III
Not yet recruiting
TORCH-LATAM-003: Regional Advanced-Therapy Pathways for Congenital Heart Disease
Congenital Heart Disease, Advanced Heart Failure
Not yet recruiting
TORCH-LATAM-004: Regional Advanced-Therapy Pathways for Adults With Acquired or Structural Heart Disease
Advanced Heart Failure, Acquired Heart Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Peter M Eckman, MD principal investigator
University of Minnesota
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Advanced Heart Failure, run by University of Minnesota at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 18 Dec 2014. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Sub-maximal exercise ventilation parameters (time frame: Pre and Post-LVAD placement). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Dec 2014.