Atrial FibrillationTOCCATANCT01223469

TOCCATA - Touch+™ for Catheter Ablation

A study testing Contact force assisted irrigated RF ablation in people with Atrial Fibrillation and Tachycardia, Supraventricular, run by Abbott Medical Devices.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The main objective of this study is to demonstrate the clinical safety of a contact force sensing RF ablation catheter when used for the treatment of supraventricular tachycardia and atrial fibrillation. Read more about this study

Who is it for?
Ages 18 to 75 years
What is being tested?
Contact force assisted irrigated RF ablation
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
77 participants
Where
No sites listed yet
Study dates
Sep 2008to Feb 2010
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 75 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients with right-sided SVT (including: atrioventricular nodal re entry tachycardia [AVNRT], accessory pathway Wolff Parkinson White [WPW] syndrome, atrial tachycardia or isthmus-dependent atrial flutter) or paroxysmal atrial fibrillation

Who cannot join

  • Recent (within 3 months) cardiac events including myocardial infarction, acute coronary syndrome, percutaneous coronary intervention, or valve or coronary bypass graft surgery
  • Moderate or severe structural heart disease (ventricular dysfunction or valve disease) as demonstrated by transthoracic (TTE) or transesophageal echocardiogram (TEE) of all four chambers of the heart
  • Known cerebrovascular disease, including a history of stroke or transient ischemic attack
  • Left ventricular ejection fraction of <35%
  • Previous heart ablation procedure (surgical or catheter) to the target chamber

About this study

Official title: A Prospective Safety, Performance and Preliminary Effectiveness, Multi-centre, Clinical Investigation Using the Irrigated TactiCath™ Percutaneous Ablation Catheter for the Treatment of Supra-Ventricular Tachyarrhythmia Using RF Ablation

The main objective of this study is to demonstrate the clinical safety of a contact force sensing RF ablation catheter when used for the treatment of supraventricular tachycardia and atrial fibrillation. In addition, the study will characterize the use and value of contact force measurement during ablation, and the long term success (12 months) of the ablation procedure using this technology.

Read the detailed description

Safety: The primary safety endpoint assesses the incidence of procedure or device related SAEs from procedure to 7 (±1) days post-procedure or hospital discharge, whichever is longer, for patients with right-sided SVT or 3 months (±2 weeks) post-procedure for patients with atrial fibrillation. Secondary safety objectives were to demonstrate safety (operative and post-operative complications) over the 12 months post-procedure.

Performance: The primary performance endpoint is to demonstrate successful catheter deployment, irrigation and ablation at the target area during supra-ventricular cardiac ablation. The secondary performance endpoint is to demonstrate successful and effective contact force reading between catheter tip and heart wall during mapping and ablation at all locations and all angulations.

Efficacy: Secondary effectiveness objectives will consider acute and chronic elimination of the target arrhythmia, the cost-effectiveness of the system and procedure-related parameters

Being tested
Contact force assisted irrigated RF ablation
Keywords
Atrial Fibrillation, Supraventricular Tachycardia, Contact Force, RF Ablation, Radiofrequency, Pulmonary Vein Isolation, Paroxysmal Atrial Fibrillation
Medical subject headings
Atrial Fibrillation, Tachycardia, Supraventricular

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Contact force assisted irrigated RF ablationDevice

    Also called TactiCath®, TactiSys®

    radiofrequency ablation of atrial fibrillation or SVT

Study groups in NCT01223469
Study groupRoleWhat they receive
Atrial FibrillationExperimentalNot described
Receives: Device: Contact force assisted irrigated RF ablation
Right-sided Supraventricular TachycardiaExperimentalNot described
Receives: Device: Contact force assisted irrigated RF ablation

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of Subjects With Operative and Post-operative Serious Adverse Events

    For Right SVT patients 7 days (±1 day) following the index procedure or until hospital discharge whichever is longer.

    For AF patients 3 months (±2 weeks)following the index procedure.

    Measured: 3 months for AF arm; 7 days for the right SVT arm

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Oct 2010 (estimated)
  2. Study startSep 2008
  3. Primary completionFeb 2010
  4. Study completionFeb 2010

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Non-randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
77 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01223469
Sponsor's protocol ID
VP-001 147
Acronym
TOCCATA
Status last verified
Jan 2019
First submitted
18 Oct 2010
Last updated
30 Jan 2019
Data monitoring committee
Yes

Publications

  • Reddy VY, Shah D, Kautzner J, Schmidt B, Saoudi N, Herrera C, Jais P, Hindricks G, Peichl P, Yulzari A, Lambert H, Neuzil P, Natale A, Kuck KH. The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm. 2012 Nov;9(11):1789-95. doi: 10.1016/j.hrthm.2012.07.016. Epub 2012 Jul 20.

    PubMed 22820056
  • Kuck KH, Reddy VY, Schmidt B, Natale A, Neuzil P, Saoudi N, Kautzner J, Herrera C, Hindricks G, Jais P, Nakagawa H, Lambert H, Shah DC. A novel radiofrequency ablation catheter using contact force sensing: Toccata study. Heart Rhythm. 2012 Jan;9(1):18-23. doi: 10.1016/j.hrthm.2011.08.021. Epub 2011 Aug 26.

    PubMed 21872560

Questions about this trial

What is this clinical trial studying?

A study testing Contact force assisted irrigated RF ablation in people with Atrial Fibrillation and Tachycardia, Supraventricular, run by Abbott Medical Devices.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 30 Jan 2019. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 3 Jun 2014). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of Subjects With Operative and Post-operative Serious Adverse Events (time frame: 3 months for AF arm; 7 days for the right SVT arm). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01223469, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Jan 2019; AzTrials last refreshed its copy on 30 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in