Clinical Assessment of a Customized Free-form Progressive Addition Lens Spectacle

A study testing Standard, non-free-form, non-customized PAL spectacles and Individually customized free-form surfaced PAL spectacles in people with Presbyopia, run by University of California, Berkeley at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study was to compare objective clinical measures of visual performance and subjective measures of satisfaction and preference between standard progressive addition lens (PAL) spectacles and a new type of free-form surfaced, optically customized PAL spectacle. Read more about this study

Who is it for?
Ages 39 to 80 yearsHealthy volunteers can take part
Conditions the study is for
Presbyopia
What is being tested?
Standard, non-free-form, non-customized PAL spectacles and Individually customized free-form surfaced PAL spectacles
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
95 participants
Where
1 siteUnited States
Study dates
Feb 2009to Oct 2009
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 39 to 80 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Presbyope
  • Experienced PAL spectacle wearer
  • Correctable to at least 20/25 in both eyes
  • Able and willing to use Test and Control spectacles for 1 week each as primary form of presbyopia correction
  • Able and willing to complete all laboratory measurements and questionnaire batteries

Who cannot join

  • Purchasing free-form PAL spectacles from the UC Berkeley Eyewear Center
  • Having eye conditions or diseases that could potentially cause a decrease in visual acuity over the course of participation in the study
  • Having eye conditions or diseases that could potentially interfere with ability to use Test and Control spectacles as primary form of presbyopia correction

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Clinical Research Center, School of Optometry, University of California, Berkeley

    Berkeley, California, 94720-2020

Other trials in United States

About this study

The purpose of this study was to compare objective clinical measures of visual performance and subjective measures of satisfaction and preference between standard progressive addition lens (PAL) spectacles and a new type of free-form surfaced, optically customized PAL spectacle.

Read the detailed description

In a double-masked crossover trial, 95 experienced wearers wore customized free-form PAL spectacles (Test) and standard non-free-form PAL spectacles (Control) for one week each. All subjects wore both Test and Control spectacles, and the pair to be worn first was randomly assigned. At dispensing and after 1 week of wear, subjects were tested for distance and near visual acuity (VA) under both high and low contrast; in addition, 30 degree off-axis VA was measured using a novel apparatus, as was the horizontal extent of undistorted vision at reading distance. Subjects also completed a set of questionnaires detailing their satisfaction levels, adaptation times, and preferences for Test or Control spectacles for different visual tasks.

Conditions
Presbyopia
Being tested
Standard, non-free-form, non-customized PAL spectacles, Individually customized free-form surfaced PAL spectacles
Keywords
Progressive addition lenses, Customized free-form, Presbyopia, Bifocals, Subjective assessment, Visual performance, Visual acuity, Amsler grid
Medical subject headings
Presbyopia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Standard, non-free-form, non-customized PAL spectaclesDevice

    Control spectacles include several different PAL brands as selected by patients in the UC Berkeley Optometry Clinic and purchased in the Eyewear Center; after successful fitting and purchase, potential subjects were recruited for the trial.

  • Individually customized free-form surfaced PAL spectaclesDevice

    Also called Zeiss Individual, Carl Zeiss Vision, Inc., Germany

    Test spectacles are Zeiss Individual, free-form surfaced, and customized using the iTerminal device to account for individual back vertex distance, wrap angle and pantoscopic tilt

Study groups in NCT01234207
Study groupRoleWhat they receive
Randomized Order of Interventions 1Active comparatorRandomized to first wear standard, non-free-form, non-customized PAL spectacles, then second, crossover to wear individually customized free-form surfaced PAL spectacles
Receives: Device: Standard, non-free-form, non-customized PAL spectacles; Device: Individually customized free-form surfaced PAL spectacles
Randomized Order of Interventions 2Active comparatorRandomized to first wear individually customized free-form surfaced PAL spectacles, then second, crossover to wear standard, non-free-form, non-customized PAL spectacles
Receives: Device: Standard, non-free-form, non-customized PAL spectacles; Device: Individually customized free-form surfaced PAL spectacles

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Visual Acuity, High Contrast, Distance Chart

    Standard assessment of high contrast visual acuity at distance, as in normal clinical practice, using Baily-Lovey charts and the M\&S Technologies Smart System II visual acuity projection system.

    Measured: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles

  2. Visual Acuity, Low Contrast, Distance Chart

    Standard assessment of low contrast visual acuity at distance, as in normal clinical practice, using Baily-Lovey charts and the M\&S Technologies Smart System II visual acuity projection system.

    Measured: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles

  3. Visual Acuity, High Contrast, Near Chart

    Standard assessment of high contrast visual acuity at near, as in normal clinical practice, using Baily-Lovey charts and the M\&S Technologies Smart System II visual acuity projection system.

    Measured: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles

  4. Visual Acuity, Low Contrast, Near Chart

    Standard assessment of low contrast visual acuity at near, as in normal clinical practice, using Baily-Lovey charts and the M\&S Technologies Smart System II visual acuity projection system.

    Measured: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles

  5. 30-degree Off-axis Distance Visual Acuity, High Contrast Chart

    Measured with subject immobilized in specially designed apparatus, keeping head pointed straight forward and moving only the eyes to left or right to view the off-axis chart

    Measured: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles

  6. 30-degree Off-axis Distance Visual Acuity, Low Contrast Chart

    Measured with subject immobilized in specially designed apparatus, keeping head pointed straight forward and moving only the eyes to left or right to view the off-axis chart

    Measured: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles

  7. Horizontal Extent of Undistorted Vision at Reading Distance

    Novel apparatus designed to immobilize head and allow subject to indicate point of peripheral optical distortion on a modified Amsler-type grid

    Measured: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles

  8. Questionnaire Battery

    Forced-choice Likert scale preference questionnaire

    Measured: At study exit, after both Test and Control spectacles had been worn for 1 week each

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Nov 2010 (estimated)
  2. Study startFeb 2009
  3. Primary completionOct 2009
  4. Study completionOct 2009

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
Double blind
Who is masked
Participant, Investigator
Enrolment
95 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01234207
Sponsor's protocol ID
CZV_PAL1
Acronym
CZV_PAL1
Status last verified
Apr 2017
First submitted
3 Nov 2010
Last updated
18 Apr 2017
Data monitoring committee
No

Publications

  • Han SC, Graham AD, Lin MC. Clinical assessment of a customized free-form progressive add lens spectacle. Optom Vis Sci. 2011 Feb;88(2):234-43. doi: 10.1097/OPX.0b013e31820846ac.

    PubMed 21217408

Questions about this trial

What is this clinical trial studying?

A study testing Standard, non-free-form, non-customized PAL spectacles and Individually customized free-form surfaced PAL spectacles in people with Presbyopia, run by University of California, Berkeley at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 18 Apr 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 18 Apr 2017). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Visual Acuity, High Contrast, Distance Chart (time frame: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles). The study lists 8 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01234207, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Apr 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in