Computed TomographyChrysalisNCT01261559

Breast Displacement and CT Radiation Dose

A study testing Chrysalis breast displacement device in people with Computed Tomography and Radiation Dosage, run by University of Washington at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The primary hypothesis of this study is that breast displacement out of the direct plane of imaging during computed tomography (CT) of the abdomen will reduce effective radiation dose to the female breast. Secondary hypotheses are that image noise and artifacts will also be decreased. Read more about this study

Who is it for?
Ages 18 to 60 years, women only
Conditions the study is for
Computed Tomography, Radiation Dosage
What is being tested?
Chrysalis breast displacement device
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
72 participants
Where
1 siteUnited States
Study dates
Dec 2010to Feb 2012
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 60 years
  • Women only
  • No healthy volunteers
  • Adult

Who may be able to join

  • scheduled for CT of the abdomen and pelvis at Harborview Medical Center
  • able to provide written informed consent

Who cannot join

  • Inability to provide written consent for self (minor, intubated, sedated, mentally incapacitated, in excessive physical distress)
  • Chest or breast surgery within the previous 8 weeks
  • Breast implants
  • Open wounds to the chest wall
  • Fractures of the ribs or spine within the previous 3 months
  • Patients requiring oxygen therapy
Show all 10Show fewer
  • Mastectomy
  • Breast radiation therapy
  • Scarring to the breasts which would prevent displacement
  • Claustrophobia is not an absolute exclusion criterion, but patient comfort will be a primary concern.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Harborview Medical Center

    Seattle, Washington, 98104

Other trials in United States

About this study

Official title: Effect of Displacement During Computed Tomography on Breast Radiation Dose and Image Quality

The primary hypothesis of this study is that breast displacement out of the direct plane of imaging during computed tomography (CT) of the abdomen will reduce effective radiation dose to the female breast. Secondary hypotheses are that image noise and artifacts will also be decreased.

Read the detailed description

Computed tomography (CT) is a significant source of medical-related radiation, and radiation-related cancer risk is increasingly recognized in the medical and lay community. One of the groups at greatest risk for radiation-induced malignancies is young females due to the radiosensitivity of female breast tissue. Breast tissue frequently lies within the imaging plane for CT of the abdomen with limited gain in diagnostic information. We propose displacing this breast tissue out of the direct imaging plane will decrease unnecessary radiation exposure and may also indirectly improve image quality.

A device called Chrysalis has been designed and received FDA approval for the purposes of displacing female breast tissue during CT.

Being tested
Chrysalis breast displacement device
Keywords
Computed tomography, Radiation dose, Dose reduction, Breast displacement, Chrysalis device, Image quality

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Chrysalis breast displacement deviceDevice

    Chrysalis is a cloth device secured with velcro and buckles around the upper abdomen and chest following manual cephalad breast displacement.

Study groups in NCT01261559
Study groupRoleWhat they receive
Standard CTNo interventionWomen assigned to undergo CT using the standard dose reduction methods (including bismuth shielding and tube current modulation) but without the Chrysalis device.
Chrysalis CTExperimentalWomen assigned to undergo CT using the standard dose reduction methods (including bismuth shielding and tube current modulation) plus application of the Chrysalis device for breast displacement.
Receives: Device: Chrysalis breast displacement device

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Skin Entrance Radiation Dose During Computed Tomography (CT)

    Skin entrance radiation doses will be measured with Thermoluminescent dosimeters (TLDs) affixed to the subject's chest and breast during CT of the abdomen. TLD #1 is at the inframammary fold, serving as internal control for each subject. Three additional TLDs (#2-4) are affixed to the subject's breast at 3 pre-ascribed locations. The same is done for the right and left breasts (8 TLDs total). TLDs will then be submitted to Landaeur for measurement.

    Measured: from time potential subject approached about possible enrollment to time device and TLDs were removed, on average 1 hour

  2. Relative Skin Entrance Radiation Dose in % During Computed Tomography (CT)

    Relative skin entrance dose at the breast (group mean of patient's average skin entrance dose at TLDs 2-4) divided by skin entrance dose at the inframammary TLD (TLD 1) in %. For each patient, doses at TLDs 2-4 were averaged, and then the group mean of this was divided by the group mean at the inframammary TLD, then multiplied by 100 to get % dose. A relative dose of 20% means that the skin entrance dose at the breast was 20% of the skin entrance dose at the inframammary fold.

    Measured: from time potential subject approached about possible enrollment to time device and TLDs were removed, on average 1 hour

Secondary outcomes (2)
  1. CT Image Noise

    To evaluate image noise, mean of the Standard deviation (SD) of the pixel values, measured in Hounsfield units (HU), will be measured in Picture Archiving and Communication System (PACS) using a region of interest (ROI) measuring 90-110 mm^2 in size drawn over each of these body regions: hepatic dome, spleen, renal cortex, retroperitoneal fat, subcutaneous fat, paraspinal muscles, and if present, breast tissue, avoiding vascular structures in each case. SD for ROI measuring 90-110 mm^2 in size will also be drawn over the aorta and inferior vena cava (IVC), remote from contrast mixing artifact, and over medullary bone of the spine.

    HU is the linear scale by which digital image data are displayed in PACS and reflect relative attenuation compared to distilled water at a standard temperature and pressure (STP) (defined as 0 HU) and of pure air at STP (defined as -1000HU). Within a drawn ROI, the PACS will give the mean attenuation (in HU) and the standard deviation of HU (reflecting

    Measured: two months

  2. Number of Participants With Presence of Artifacts Based on CT Image Quality

    CT images acquired will be reviewed for the presence of artifacts that might be attributed to the displacement device or to the presence of the breast tissue.

    To evaluate for artifacts, the exam will be qualitatively reviewed by a board certified radiologist for imaging artifacts, such as streak artifact. It will be noted on a per participant basis whether any imaging artifacts are identified.

    Measured: two months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 Dec 2010 (estimated)
  2. Study startDec 2010
  3. Primary completionFeb 2012
  4. Study completionFeb 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
72 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01261559
Sponsor's protocol ID
39071
Acronym
Chrysalis
Status last verified
Jun 2018
First submitted
8 Dec 2010
Last updated
6 Jul 2018
Data monitoring committee
No

Publications

  • Berrington de Gonzalez A, Mahesh M, Kim KP, Bhargavan M, Lewis R, Mettler F, Land C. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med. 2009 Dec 14;169(22):2071-7. doi: 10.1001/archinternmed.2009.440.

    PubMed 20008689
  • Smith-Bindman R, Lipson J, Marcus R, Kim KP, Mahesh M, Gould R, Berrington de Gonzalez A, Miglioretti DL. Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med. 2009 Dec 14;169(22):2078-86. doi: 10.1001/archinternmed.2009.427.

    PubMed 20008690
  • Hurwitz LM, Yoshizumi TT, Reiman RE, Paulson EK, Frush DP, Nguyen GT, Toncheva GI, Goodman PC. Radiation dose to the female breast from 16-MDCT body protocols. AJR Am J Roentgenol. 2006 Jun;186(6):1718-22. doi: 10.2214/AJR.04.1917.

    PubMed 16714665
  • Parker MS, Hui FK, Camacho MA, Chung JK, Broga DW, Sethi NN. Female breast radiation exposure during CT pulmonary angiography. AJR Am J Roentgenol. 2005 Nov;185(5):1228-33. doi: 10.2214/AJR.04.0770.

    PubMed 16247139
  • Pajor L, Kalman E, Koszegi T. Cholesteryl hemisuccinate's inductive effect on membrane rigidization regarding both, its remodelling of the cells' surface receptor pattern and its decreasing the natural killer susceptibility of K-562 cells. Acta Biol Hung. 1991;42(4):371-83.

    PubMed 1841487
  • Yilmaz MH, Albayram S, Yasar D, Ozer H, Adaletli I, Selcuk D, Akman C, Altug A. Female breast radiation exposure during thorax multidetector computed tomography and the effectiveness of bismuth breast shield to reduce breast radiation dose. J Comput Assist Tomogr. 2007 Jan-Feb;31(1):138-42. doi: 10.1097/01.rct.0000235070.50055.e6.

    PubMed 17259846
  • Kang M, Ragan BG, Park JH. Issues in outcomes research: an overview of randomization techniques for clinical trials. J Athl Train. 2008 Apr-Jun;43(2):215-21. doi: 10.4085/1062-6050-43.2.215.

    PubMed 18345348

Questions about this trial

What is this clinical trial studying?

A study testing Chrysalis breast displacement device in people with Computed Tomography and Radiation Dosage, run by University of Washington at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 10 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 6 Jul 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 5 Nov 2013). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Skin Entrance Radiation Dose During Computed Tomography (CT) (time frame: from time potential subject approached about possible enrollment to time device and TLDs were removed, on average 1 hour). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01261559, which also lists 7 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Jul 2018.