DiabetesNCT01264016
Performance of a New Glucose Meter System
A study testing Investigational Blood Glucose Monitoring System in people with Diabetes, run by Ascensia Diabetes Care at 1 site in United States.
Trial summary
The purpose of this study is to evaluate the performance and acceptability of a new blood glucose monitoring system, which includes meter and sensor strip. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Diabetes
- What is being tested?
- Investigational Blood Glucose Monitoring System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 96 participants
- Where
- 1 siteUnited States
- Study dates
- Nov 2010to Dec 2010
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Type 1 or 2 diabetes
- Age 18 years or older
- Routinely performs blood glucose self testing at home, at least once per day
- Able to speak, read, and understand English.
- Is willing to complete all study procedures
Who cannot join
- Currently pregnant
- Hemophilia or any other bleeding disorder
- Taking prescription anticoagulants or has clotting problems that may prolong bleeding. Taking aspirin daily is not excluded
- Subject employee of competitive medical device company
- Cognitive disorder or other condition, which in the opinion of the investigator, would put the person at risk or seriously compromise the integrity of the study
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Performance of the TATSU/Tradewind Blood Glucose Monitoring System
The purpose of this study is to evaluate the performance and acceptability of a new blood glucose monitoring system, which includes meter and sensor strip.
- Conditions
- Diabetes
- Being tested
- Investigational Blood Glucose Monitoring System
- Medical subject headings
- Diabetes Mellitus
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Investigational Blood Glucose Monitoring SystemDevice
Untrained subjects with diabetes performed Blood Glucose (BG) tests with subject's capillary fingerstick using the investigational Tradewind meter and investigational sensor. Study staff tested subject venous blood. All BG Results were compared to a reference laboratory glucose method. Subjects' success at performing basic tasks using only the User Guide were rated by study staff.
| Study group | Role | What they receive |
|---|---|---|
| Intended Users of the Monitoring System | Experimental | Untrained subjects with diabetes use an investigational blood glucose monitoring system. Receives: Device: Investigational Blood Glucose Monitoring System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Percent of Capillary Blood Glucose (BG) Results Within +/- 5 to 20mg/dL (<75 mg/dL) or Within +/- 5% to 20% (>=75 mg/dL) of Laboratory Glucose Method
Subjects with diabetes used an investigational blood glucose monitoring system (BGMS) with subject capillary blood. BGM results were compared to a reference lab glucose method - Yellow Springs Instrument (YSI) Analyzer. BG results were used to calculate the number of BG results within +/- 5 to 20 mg/dL (for reference BG results <75mg/dL) or +/- 5 to 20% (for reference BG results >=75mg/dL) of the reference method results.
Measured: 2 hours
Percent of Venous Blood Glucose (BG) Results Within +/- 5 to 20 mg/dL (<75 mg/dL) or Within +/- 5% to 20% (>=75 mg/dL) of Laboratory Glucose Method
Healthcare professionals (study staff) used an investigational blood glucose monitoring system (BGMS) with subject venous blood. BGM results were compared to a reference lab glucose method - Yellow Springs Instrument (YSI) Analyzer. BG results were used to calculate the number of BG results within +/- 5 to 20 mg/dL (for reference BG results <75mg/dL) or +/- 5% to 20% (for reference BG results >=75mg/dL) of the reference method results.
Measured: 2 hours
Secondary outcomes (1)
Number of Subjects Rated as<=3 Performing Basic Meter Tasks (Labeling Comprehension)
Subjects reviewed the instructions for use (User Guide and Quick Reference Guide) to learn to use the system. Study staff then observed and rated the subjects (1 to 4) on their success at performing five tasks. Scale: 1.Success in performing tasks correctly without assistance. 2.Successful with additional review of User Guide. 3.Successful with additional review and study staff assist similar to review of a specific function during a Customer Service call. 4.Subject did not perform task correctly and study staff intervention was required.
Measured: 2 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted21 Dec 2010 (estimated)
- Study startNov 2010
- Primary completionDec 2010
- Study completionDec 2010
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for DiabetesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 96 participants (actual)
Sponsor and investigators
- Lead sponsor
- Ascensia Diabetes Care
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Timothy Bailey, MD, Principal investigator, AMCR Institute
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01264016
- Sponsor's protocol ID
- CTD-2010-004-01
- Status last verified
- Jan 2016
- First submitted
- 18 Dec 2010
- Last updated
- 29 Feb 2016
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 29 Feb 2016. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Performance of the TATSU/Tradewind Blood Glucose Monitoring System
- ClinicalTrials.gov ID
- NCT01264016
- Acronym / sponsor ID
- CTD-2010-004-01
- Conditions
- Diabetes
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 96 participants (actual)
- Lead sponsor
- Ascensia Diabetes CareIndustry (pharma, biotech, devices)
- Study start
- Nov 2010
- Primary completion
- Dec 2010 (actual)
- Study completion
- Dec 2010 (actual)
- First posted
- 21 Dec 2010 (estimated)
- Results
- Posted 1 May 2012
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to evaluate the performance and acceptability of a new blood glucose monitoring system, which includes meter and sensor strip.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Intended Users of the Monitoring System | Experimental | Device: Investigational Blood Glucose Monitoring SystemUntrained subjects with diabetes use an investigational blood glucose monitoring system. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Type 1 or 2 diabetes
- Age 18 years or older
- Routinely performs blood glucose self testing at home, at least once per day
- Able to speak, read, and understand English.
- Is willing to complete all study procedures
Key exclusion criteria (5 listed)
- Currently pregnant
- Hemophilia or any other bleeding disorder
- Taking prescription anticoagulants or has clotting problems that may prolong bleeding. Taking aspirin daily is not excluded
- Subject employee of competitive medical device company
- Cognitive disorder or other condition, which in the opinion of the investigator, would put the person at risk or seriously compromise the integrity of the study
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Investigational Blood Glucose Monitoring SystemUntrained subjects with diabetes performed Blood Glucose (BG) tests with subject's capillary fingerstick using the investigational Tradewind meter and investigational sensor. Study staff tested subject venous blood. All BG Results were compared to a reference laboratory glucose method. Subjects' success at performing basic tasks using only the User Guide were rated by study staff. | Device | Intended Users of the Monitoring System |
Primary outcome
Percent of Capillary Blood Glucose (BG) Results Within +/- 5 to 20mg/dL (<75 mg/dL) or Within +/- 5% to 20% (>=75 mg/dL) of Laboratory Glucose Method
Time frame: 2 hours
Subjects with diabetes used an investigational blood glucose monitoring system (BGMS) with subject capillary blood. BGM results were compared to a reference lab glucose method - Yellow Springs Instrument (YSI) Analyzer. BG results were used to calculate the number of BG results within +/- 5 to 20 mg/dL (for reference BG results <75mg/dL) or +/- 5 to 20% (for reference BG results >=75mg/dL) of the reference method results.
Percent of Venous Blood Glucose (BG) Results Within +/- 5 to 20 mg/dL (<75 mg/dL) or Within +/- 5% to 20% (>=75 mg/dL) of Laboratory Glucose Method
Time frame: 2 hours
Healthcare professionals (study staff) used an investigational blood glucose monitoring system (BGMS) with subject venous blood. BGM results were compared to a reference lab glucose method - Yellow Springs Instrument (YSI) Analyzer. BG results were used to calculate the number of BG results within +/- 5 to 20 mg/dL (for reference BG results <75mg/dL) or +/- 5% to 20% (for reference BG results >=75mg/dL) of the reference method results.
1 secondary outcome
Number of Subjects Rated as<=3 Performing Basic Meter Tasks (Labeling Comprehension)
Time frame: 2 hours
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 29 Feb 2016.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
Related trials for Diabetes
RecruitingObservational study
Genetics of Type 2 Diabetes in West Africans
Hypertension, Diabetes
Not yet recruiting
A Study to Lower Blood Pressure One Year After Childbirth in Women Who Had Preeclampsia
Adverse Pregnancy Outcomes, Cardiovascular Diseases
Not yet recruitingPhase 3
A Study Comparing SHR-3167 With Insulin Degludec in Adults With Type 2 Diabetes Currently Treated With Basal Insulin
Diabetes Mellitus, Type 2
Not yet recruiting
Different Aerobic-to-Resistance Training Ratios in Adults Aged 50 Years and Older With Prediabetes
Prediabetes
Active, not recruiting
Adapting FAMS to Optimize CGM Use Among Emerging Adults With Type 1 Diabetes
Type 1 Diabetes
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Timothy Bailey, MD principal investigator
AMCR Institute
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Investigational Blood Glucose Monitoring System in people with Diabetes, run by Ascensia Diabetes Care at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 29 Feb 2016. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 1 May 2012). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Percent of Capillary Blood Glucose (BG) Results Within +/- 5 to 20mg/dL (<75 mg/dL) or Within +/- 5% to 20% (>=75 mg/dL) of Laboratory Glucose Method (time frame: 2 hours). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Feb 2016.