Carotid Artery DiseasesPROOFNCT01264419
Silk Road Medical First in Man Study - Neuroprotection During Carotid Stenting and Angioplasty
A study testing Silk Road Embolic Protection System in people with Carotid Artery Diseases, run by Silk Road Medical at 1 site in Germany.
Trial summary
Cerebral embolization during carotid artery stenting (CAS) can often precipitate severe adverse neurological effects. Most major clinical studies of CAS have used distal filters for cerebral protection and have compared the neurologic complication rates with those of carotid endarterectomy (CEA). Read more about this study
- Who is it for?
- Ages 21 years and older
- Conditions the study is for
- Carotid Artery Diseases
- What is being tested?
- Silk Road Embolic Protection System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 75 participants
- Where
- 1 siteGermany
- Study dates
- Mar 2009to Jul 2012
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 21 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Subject must be > 21 years of age.
- Subject has the ability to understand and cooperate with study procedures and agrees to return for all required follow-up visits, tests and exams.
- Subjects taking warfarin may be included if their dosage is reduced before the procedure to result in an International Normalized Ratio (INR) of 1.5 or less. Warfarin may be restarted to therapeutic dose after the procedure.
- The subject must sign a written informed consent prior to the procedure, using a form that is approved by the local medical ethics committee (EC).
- The life expectancy of the subject is at least one year.
- The subject has a lesion located in the internal carotid artery (ICA); the carotid bifurcation may be involved.
- The subject must have a minimum distance of 5 cm between the clavicle and bifurcation, as assessed by duplex Doppler ultrasound, computed axial tomographic (CT) angiography or magnetic resonance (MR) angiography.
Who cannot join
- The subject was participating in another investigational trial that would interfere with the conduct or result of this study.
- The subject had dementia or a neurological illness that may confound the neurological evaluation.
- Presence of any one of the following anatomic risk factors:
- Previous radiation treatment to the neck or radical neck dissection
- Tracheostomy or tracheal stoma
- Laryngectomy
Show all 30Show fewer
- Contralateral laryngeal nerve palsy
- Severe tandem lesions
- Inability to extend the head due to cervical arthritis or other cervical disorders
- A total occlusion of the target vessel.
- There was an existing, previously placed stent in the target artery.
- The subject had a known life-threatening allergy to the contrast media that cannot be treated.
- Subject had history of intolerance or allergic reaction to any of the study medications including aspirin, Clopidogrel bisulfate (Plavix®) or Ticlopidine (Ticlid®), heparin or Bivalrudin (Angiomax™). Subject was unable to tolerate a combination of aspirin and Clopidogrel/Ticlopidine.
- The subject had a GI bleed that would interfere with antiplatelet therapy.
- The subject had known cardiac source of potential emboli.
- Subject had a Hemoglobin (Hgb) level less than 8 gm/dL (unless on dialysis), platelet count < 50,000/mm3, or known heparin associated thrombocytopenia.
- Subject had documented atrial fibrillation in the 90 days prior to the procedure.
- The subject had a history of bleeding diathesis or coagulopathy including thrombocytopenia or an inability to receive heparin in amounts sufficient to maintain an Activated Clot Time (ACT) at > 250, or will refuse blood transfusion.
- The subject had atherosclerotic disease involving in the ipsilateral common carotid artery that precluded safe placement of the arterial sheath.
- The subject has other abnormal angiographic findings that indicate the subject is at risk for a stroke due to a problem other than that of the target lesion, such as: ipsilateral arterial stenosis greater in severity than the target lesion, cerebral aneurysm, or arteriovenous malformation of the cerebral vasculature.
- There is evidence of a carotid artery dissection prior to the initiation of the procedure.
- There is an angiographically visible thrombus.
- There is any condition that precludes proper angiographic assessment or makes percutaneous arterial access unsafe, e.g. morbid obesity, sustained systolic blood pressure > 180 mm Hg, tortuosity, occlusive disease, vessel anatomy, aortic arch anatomy, or cerebral protective system.
- Occlusion (TIMI 0 flow), or string sign of the ipsilateral common or internal carotid artery.
- There is evidence of bilateral carotid stenosis that would require intervention within 30 days of procedure.
- There is evidence of a stroke within the previous 30 days of the procedure.
- There is a planned treatment of a non-target lesion within 30 days post procedure.
- There is a history of intracranial hemorrhage within the previous 3 months, including hemorrhagic transformation of an ischemic stroke.
- There is a history of an ipsilateral stroke with fluctuating neurologic symptoms within one year of the procedure.
- Female subjects who are pregnant or may become pregnant.
Trial locations and contacts
1 site in 1 country.
About this study
Official title: SILK ROAD™ MEDICAL EMBOLIC PROTECTION SYSTEM: FIRST IN MAN STUDY "The PROOF Study"
Cerebral embolization during carotid artery stenting (CAS) can often precipitate severe adverse neurological effects. Most major clinical studies of CAS have used distal filters for cerebral protection and have compared the neurologic complication rates with those of carotid endarterectomy (CEA). Many currently available embolic protection devices, however, have limited efficacy in capturing microembolic debris that is liberated during stenting, pre-dilatation and post-dilatation. Distal protection systems are furthermore limited by the need to cross the lesion prior to deployment. Some studies have shown a relatively high incidence of cerebral infarction even when distal protection devices are employed.
Cerebral protection with carotid flow reversal is a method that was developed by Parodi, et al., as an alternative to the use of distal protection devices. While novel in its approach, this method too has its limitations. Criado, et al., developed a derivative technique that employs carotid flow reversal prior to traversing the stenosis and can be accomplished by directly accessing carotid anatomy without the use of the transfemoral approach. Major benefits to this method include the ability to perform the procedure on patients with severe carotid tortuosity and difficult aortic arch anatomy.
Read the detailed description
Carotid artery disease is known to increase the risk of neurologic consequences such as transient ischemic attacks (TIA), ischemic stroke, or death due to the release of embolic particles in the vessels supplying the brain. Two principal treatments, carotid endarterectomy (CEA), and carotid artery stenting (CAS), are used to treat this disease. Embolic protection devices, both distal filters and occlusive devices, are employed during the CAS procedure to reduce the risk of carotid plaque embolus secondary to instrumentation during carotid intervention. Existing embolic protection devices are placed using a transfemoral approach and thus have potential for particle embolization while crossing the aortic arch, supraaortic trunk and the carotid lesion before cerebral protection is in place. Other limitations of these devices include the potential for carotid intimal injury, dissection or spasm during deployment, and release of emboli during retrieval.
Noting that carotid embolization remains the "Achilles heel" of carotid artery stenting, an alternative approach to embolic protection was developed by Juan Parodi. The system works by balloon occlusion of the common carotid artery and external carotid artery. An arteriovenous fistula is created with sheaths and catheters and provides retrograde (reverse) blood flow from the internal carotid artery (ICA) and the common carotid artery (CCA) to the femoral vein.
Embolic particles released during CAS pass retrograde through a catheter into a 180 micron filter before the blood re-enters the venous system. (Parodi, Ferreira et al. 2005) A variation of the reverse flow approach utilizing a surgical, transcervical approach to the carotid artery was developed to address challenges and risks associated with the placement and use of existing embolic protection devices. Criado et al. (2004) describe the use of flow reversal during CAS via a transcervical surgical cutdown, access and proximal occlusion of the CCA and establishment of a carotid artery - internal jugular (IJ) vein fistula. (Criado, Doblas et al. 2004).
A difference between the transfemoral-based Parodi approach and the transcervical-based Criado approach is the removal by Criado of the ECA occlusion step. In the Criado approach, the procedure is designed such that the flow is reversed in both the internal and the external carotid arteries, whereas in the Parodi procedure, flow reversal occurs only in the ICA. Another difference in the Criado system is the shorter length and larger diameter tubing afforded by the transcervical approach. The rate of flow reversal enabled by the Criado arteriovenous shunt is higher and is designed to overcome the potential for antegrade flow from the ECA to the ICA.
However, as reported by both Parodi and Criado, active aspiration is often utilized during critical periods of the procedure, to guarantee robust reversal of flow in the ICA.
Similarly in 2004, Chang, et al., reported the use of a direct transcervical approach through a 2cm incision at the base of the neck in 21 CAS patients with a 0% technical failure rate and a 0% thirty-day combined stroke or mortality rate. A similar approach of direct access to the low common carotid artery and the creation of a shunt to the internal jugular was used with carotid occlusion leading to a state of flow reversal. In some cases in this series, a balloon was placed in the external carotid artery. (Chang et al, 2004) Subsequently, Criado et al reported in the Journal of Vascular Surgery in 2004 on a series of fifty patients who underwent carotid artery stenting via this transcervical approach. Using the technique described above, flow was reversed in the ICA by occluding the CCA and establishing a carotid-jugular vein fistula. There was technical success in all 50 procedures and no strokes or deaths occurred. The procedure was tolerated by all but two (4%) of patients. Complications included major and minor carotid artery dissections, which resolved after stent placement. Two transient ischemic attacks (TIA) occurred, one in a patient in whom flow reversal was not successful, and one patient with a contralateral ICA occlusion who suffered a contralateral TIA.(Criado, Doblas et al. 2004).
Criado et al. further report in the Journal of Vascular Surgery in 2004 on a series of 10 awake patients undergoing transcervical carotid artery stenting with flow reversal. Procedural success was achieved in all 10 cases and flow reversal was well tolerated. Cerebral oxygenation during ICA flow reversal was comparable to that during CCA occlusion. ICA angioplasty balloon inflation produced a decrease in SVO2 significantly greater than that occurring during ICA flow reversal. (Criado, Doblas et al. 2004) Finally, Criado et al report on the perioperative and 3 year follow up results of 103 consecutive carotid artery stenting procedures done with a transcervical approach using carotid flow reversal for cerebral protection performed over a 28 month period in 97 patients. Technical success was achieved in 100 cases (97%). No major strokes or deaths occurred. Three awake patients (4%) did not tolerate flow reversal and complications included one ipsilateral TIA, one contralateral TIA, and two minor strokes. There were two wound complications and one major arterial complication. Mean flow reversal time was 21 minutes. At 40 months, the stent patency rate on an intention-to-treat basis was 95%, and the stroke-free survival was 91%. (Criado, Fontcuberta et al. 2007).
In 2006, Ribo and colleagues monitored transcranial doppler (TCD) as part of their standard carotid practice where 23 of 65 patients underwent transcervical carotid stenting using Criado's technique. Mean reversal time was about 15 minutes and well tolerated. TCD monitoring showed an absence of air/solid emboli during stent deployment and angioplasty confirming the presence of reverse flow. Baseline middle cerebral artery (MCA) flow by TCD of 47 cm/sec was substantially decreased with clamping of the common carotid (representing reversal of internal carotid flow). Initial mean antegrade MCA velocity of 30 cm/sec was present post clamping suggesting that there was adequate hemispheric blood flow to be clinically tolerated (Ribo et al. 2006).
Silk Road Medical has developed a system of sheaths, shunts and flow regulators, called the SRM Embolic Protection System, to apply the demonstrated benefits of the Criado and Chang approaches and improve further on ease of use and effectiveness. Silk Road Medical has provided an arteriovenous shunt with the ability to regulate from a low, baseline flow to a higher flow rate. This is accomplished by modulating the flow resistance of a shunt line which connects an arterial and a venous sheath. Because of potential patient intolerance to long periods of high reverse flow, the flow controller enables the user the set the shunt high flow only during periods of the procedure which are high risk for embolic debris (angiography, angioplasty, stent placement). This system eliminates the need for an active aspiration step, and theoretically enables the user to balance patient tolerance needs with optimal embolic protection.
The conclusion from the series of above literature is that transcervical CAS with carotid flow reversal can be accomplished with a high rate of technical success, a very low rate of major adverse events, and an excellent 3 year stroke free survival and stent patency rate. The purpose of this initial investigation is to determine if the SRM Embolic Protection System enables flow reversal of the carotid artery, is compatible with the techniques, devices and equipment used during a carotid artery stenting CAS procedure, and does not present any additional safety risks to the patient.
- Conditions
- Carotid Artery Diseases
- Being tested
- Silk Road Embolic Protection System
- Medical subject headings
- Carotid Artery Diseases
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Silk Road Embolic Protection SystemDevice
System that delivers a carotid artery stent, via transcervical access using reverse flow cerebral protection, as treatment for high-grade extracranial carotid artery disease
| Study group | Role | What they receive |
|---|---|---|
| Silk Road Embolic Protection System | Experimental | Eligible subjects who are to receive a carotid artery stent, via transcervical access using reverse flow cerebral protection, as treatment for high-grade extracranial carotid artery disease Receives: Device: Silk Road Embolic Protection System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Safety Evaluation as Composite of Occurrences of Major Stroke, Myocardial Infarction and Death
Safety will be evaluated as a composite of major stroke, myocardial infarction and death during the 30-day post procedural period.
Measured: 0 days post-procedure to 30 days post-procedure
Secondary outcomes (1)
Number of Participants Demonstrating Acute Device Success, Procedural Success, and Tolerance to Reverse Flow
Acute Device Success is calculated by tabulating the number of subjects in whom reverse flow could be established AND who received at least 1 stent; Procedural Success is the freedom from MAEs at 30 days post-procedure, where MAEs are defined in the protocol as "A composite rate of death, major stroke, and myocardial infarction (Q wave and non-Q wave)"; Tolerance to Reverse flow is measured as the absence of "any temporary occurrence of procedure related neurological symptoms following the establishment of the cerebral reverse flow circuit that resolves within 20 minutes of flow manipulation". The number of subjects included in "Tolerance to Reverse Flow" were those subjects for whom reverse flow could be both established and measured.
Measured: peri-operative to 30 days post-procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted21 Dec 2010 (estimated)
- Study startMar 2009
- Primary completionJun 2012
- Study completionJul 2012
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Carotid Artery DiseasesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 75 participants (actual)
Sponsor and investigators
- Lead sponsor
- Silk Road Medical
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Sumaira Macdonald, MD, PhD, Study chair, Chief Medical Officer
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01264419
- Sponsor's protocol ID
- SRM-2008-01
- Acronym
- PROOF
- Status last verified
- Jan 2020
- First submitted
- 17 Dec 2010
- Last updated
- 17 Feb 2020
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
Publications
Pinter L, Ribo M, Loh C, Lane B, Roberts T, Chou TM, Kolvenbach RR. Safety and feasibility of a novel transcervical access neuroprotection system for carotid artery stenting in the PROOF Study. J Vasc Surg. 2011 Nov;54(5):1317-23. doi: 10.1016/j.jvs.2011.04.040. Epub 2011 Jun 12.
PubMed 21658889Alpaslan A, Wintermark M, Pinter L, Macdonald S, Ruedy R, Kolvenbach R. Transcarotid Artery Revascularization With Flow Reversal. J Endovasc Ther. 2017 Apr;24(2):265-270. doi: 10.1177/1526602817693607. Epub 2017 Feb 17.
PubMed 28335706
Study at a glance
From the registry record, last updated by the sponsor on 17 Feb 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- SILK ROAD™ MEDICAL EMBOLIC PROTECTION SYSTEM: FIRST IN MAN STUDY "The PROOF Study"
- ClinicalTrials.gov ID
- NCT01264419
- Acronym / sponsor ID
- PROOF / SRM-2008-01
- Conditions
- Carotid Artery Diseases
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 75 participants (actual)
- Lead sponsor
- Silk Road MedicalIndustry (pharma, biotech, devices)
- Study start
- Mar 2009
- Primary completion
- Jun 2012 (actual)
- Study completion
- Jul 2012 (actual)
- First posted
- 21 Dec 2010 (estimated)
- Results
- Posted 8 Jul 2019
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Cerebral embolization during carotid artery stenting (CAS) can often precipitate severe adverse neurological effects. Most major clinical studies of CAS have used distal filters for cerebral protection and have compared the neurologic complication rates with those of carotid endarterectomy (CEA). Many currently available embolic protection devices, however, have limited efficacy in capturing microembolic debris that is liberated during stenting, pre-dilatation and post-dilatation. Distal protection systems are furthermore limited by the need to cross the lesion prior to deployment. Some studies have shown a relatively high incidence of cerebral infarction even when distal protection devices are employed.
Cerebral protection with carotid flow reversal is a method that was developed by Parodi, et al., as an alternative to the use of distal protection devices. While novel in its approach, this method too has its limitations. Criado, et al., developed a derivative technique that employs carotid flow reversal prior to traversing the stenosis and can be accomplished by directly accessing carotid anatomy without the use of the transfemoral approach. Major benefits to this method include the ability to perform the procedure on patients with severe carotid tortuosity and difficult aortic arch anatomy.
Detailed description
Carotid artery disease is known to increase the risk of neurologic consequences such as transient ischemic attacks (TIA), ischemic stroke, or death due to the release of embolic particles in the vessels supplying the brain. Two principal treatments, carotid endarterectomy (CEA), and carotid artery stenting (CAS), are used to treat this disease. Embolic protection devices, both distal filters and occlusive devices, are employed during the CAS procedure to reduce the risk of carotid plaque embolus secondary to instrumentation during carotid intervention. Existing embolic protection devices are placed using a transfemoral approach and thus have potential for particle embolization while crossing the aortic arch, supraaortic trunk and the carotid lesion before cerebral protection is in place. Other limitations of these devices include the potential for carotid intimal injury, dissection or spasm during deployment, and release of emboli during retrieval.
Noting that carotid embolization remains the "Achilles heel" of carotid artery stenting, an alternative approach to embolic protection was developed by Juan Parodi. The system works by balloon occlusion of the common carotid artery and external carotid artery. An arteriovenous fistula is created with sheaths and catheters and provides retrograde (reverse) blood flow from the internal carotid artery (ICA) and the common carotid artery (CCA) to the femoral vein.
Embolic particles released during CAS pass retrograde through a catheter into a 180 micron filter before the blood re-enters the venous system. (Parodi, Ferreira et al. 2005) A variation of the reverse flow approach utilizing a surgical, transcervical approach to the carotid artery was developed to address challenges and risks associated with the placement and use of existing embolic protection devices. Criado et al. (2004) describe the use of flow reversal during CAS via a transcervical surgical cutdown, access and proximal occlusion of the CCA and establishment of a carotid artery - internal jugular (IJ) vein fistula. (Criado, Doblas et al. 2004).
A difference between the transfemoral-based Parodi approach and the transcervical-based Criado approach is the removal by Criado of the ECA occlusion step. In the Criado approach, the procedure is designed such that the flow is reversed in both the internal and the external carotid arteries, whereas in the Parodi procedure, flow reversal occurs only in the ICA. Another difference in the Criado system is the shorter length and larger diameter tubing afforded by the transcervical approach. The rate of flow reversal enabled by the Criado arteriovenous shunt is higher and is designed to overcome the potential for antegrade flow from the ECA to the ICA.
However, as reported by both Parodi and Criado, active aspiration is often utilized during critical periods of the procedure, to guarantee robust reversal of flow in the ICA.
Similarly in 2004, Chang, et al., reported the use of a direct transcervical approach through a 2cm incision at the base of the neck in 21 CAS patients with a 0% technical failure rate and a 0% thirty-day combined stroke or mortality rate. A similar approach of direct access to the low common carotid artery and the creation of a shunt to the internal jugular was used with carotid occlusion leading to a state of flow reversal. In some cases in this series, a balloon was placed in the external carotid artery. (Chang et al, 2004) Subsequently, Criado et al reported in the Journal of Vascular Surgery in 2004 on a series of fifty patients who underwent carotid artery stenting via this transcervical approach. Using the technique described above, flow was reversed in the ICA by occluding the CCA and establishing a carotid-jugular vein fistula. There was technical success in all 50 procedures and no strokes or deaths occurred. The procedure was tolerated by all but two (4%) of patients. Complications included major and minor carotid artery dissections, which resolved after stent placement. Two transient ischemic attacks (TIA) occurred, one in a patient in whom flow reversal was not successful, and one patient with a contralateral ICA occlusion who suffered a contralateral TIA.(Criado, Doblas et al. 2004).
Criado et al. further report in the Journal of Vascular Surgery in 2004 on a series of 10 awake patients undergoing transcervical carotid artery stenting with flow reversal. Procedural success was achieved in all 10 cases and flow reversal was well tolerated. Cerebral oxygenation during ICA flow reversal was comparable to that during CCA occlusion. ICA angioplasty balloon inflation produced a decrease in SVO2 significantly greater than that occurring during ICA flow reversal. (Criado, Doblas et al. 2004) Finally, Criado et al report on the perioperative and 3 year follow up results of 103 consecutive carotid artery stenting procedures done with a transcervical approach using carotid flow reversal for cerebral protection performed over a 28 month period in 97 patients. Technical success was achieved in 100 cases (97%). No major strokes or deaths occurred. Three awake patients (4%) did not tolerate flow reversal and complications included one ipsilateral TIA, one contralateral TIA, and two minor strokes. There were two wound complications and one major arterial complication. Mean flow reversal time was 21 minutes. At 40 months, the stent patency rate on an intention-to-treat basis was 95%, and the stroke-free survival was 91%. (Criado, Fontcuberta et al. 2007).
In 2006, Ribo and colleagues monitored transcranial doppler (TCD) as part of their standard carotid practice where 23 of 65 patients underwent transcervical carotid stenting using Criado's technique. Mean reversal time was about 15 minutes and well tolerated. TCD monitoring showed an absence of air/solid emboli during stent deployment and angioplasty confirming the presence of reverse flow. Baseline middle cerebral artery (MCA) flow by TCD of 47 cm/sec was substantially decreased with clamping of the common carotid (representing reversal of internal carotid flow). Initial mean antegrade MCA velocity of 30 cm/sec was present post clamping suggesting that there was adequate hemispheric blood flow to be clinically tolerated (Ribo et al. 2006).
Silk Road Medical has developed a system of sheaths, shunts and flow regulators, called the SRM Embolic Protection System, to apply the demonstrated benefits of the Criado and Chang approaches and improve further on ease of use and effectiveness. Silk Road Medical has provided an arteriovenous shunt with the ability to regulate from a low, baseline flow to a higher flow rate. This is accomplished by modulating the flow resistance of a shunt line which connects an arterial and a venous sheath. Because of potential patient intolerance to long periods of high reverse flow, the flow controller enables the user the set the shunt high flow only during periods of the procedure which are high risk for embolic debris (angiography, angioplasty, stent placement). This system eliminates the need for an active aspiration step, and theoretically enables the user to balance patient tolerance needs with optimal embolic protection.
The conclusion from the series of above literature is that transcervical CAS with carotid flow reversal can be accomplished with a high rate of technical success, a very low rate of major adverse events, and an excellent 3 year stroke free survival and stent patency rate. The purpose of this initial investigation is to determine if the SRM Embolic Protection System enables flow reversal of the carotid artery, is compatible with the techniques, devices and equipment used during a carotid artery stenting CAS procedure, and does not present any additional safety risks to the patient.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Silk Road Embolic Protection System | Experimental | Device: Silk Road Embolic Protection SystemEligible subjects who are to receive a carotid artery stent, via transcervical access using reverse flow cerebral protection, as treatment for high-grade extracranial carotid artery disease |
Who may qualify
- Ages
- 21 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (7 listed)
- Subject must be > 21 years of age.
- Subject has the ability to understand and cooperate with study procedures and agrees to return for all required follow-up visits, tests and exams.
- Subjects taking warfarin may be included if their dosage is reduced before the procedure to result in an International Normalized Ratio (INR) of 1.5 or less. Warfarin may be restarted to therapeutic dose after the procedure.
- The subject must sign a written informed consent prior to the procedure, using a form that is approved by the local medical ethics committee (EC).
- The life expectancy of the subject is at least one year.
Key exclusion criteria (30 listed)
- The subject was participating in another investigational trial that would interfere with the conduct or result of this study.
- The subject had dementia or a neurological illness that may confound the neurological evaluation.
- Presence of any one of the following anatomic risk factors:
- A total occlusion of the target vessel.
- There was an existing, previously placed stent in the target artery.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Silk Road Embolic Protection SystemSystem that delivers a carotid artery stent, via transcervical access using reverse flow cerebral protection, as treatment for high-grade extracranial carotid artery disease | Device | Silk Road Embolic Protection System |
Primary outcome
Safety Evaluation as Composite of Occurrences of Major Stroke, Myocardial Infarction and Death
Time frame: 0 days post-procedure to 30 days post-procedure
Safety will be evaluated as a composite of major stroke, myocardial infarction and death during the 30-day post procedural period.
1 secondary outcome
Number of Participants Demonstrating Acute Device Success, Procedural Success, and Tolerance to Reverse Flow
Time frame: peri-operative to 30 days post-procedure
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 17 Feb 2020.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Background: PubMed 21658889Pinter L, Ribo M, Loh C, Lane B, Roberts T, Chou TM, Kolvenbach RR. Safety and feasibility of a novel transcervical access neuroprotection system for carotid artery stenting in the PROOF Study. J Vasc Surg. 2011 Nov;54(5):1317-23. doi: 10.1016/j.jvs.2011.04.040. Epub 2011 Jun 12.
- Results publication: PubMed 28335706Alpaslan A, Wintermark M, Pinter L, Macdonald S, Ruedy R, Kolvenbach R. Transcarotid Artery Revascularization With Flow Reversal. J Endovasc Ther. 2017 Apr;24(2):265-270. doi: 10.1177/1526602817693607. Epub 2017 Feb 17.
- Transcarotid Artery Revascularization With Flow Reversal: The PROOF StudyLink provided by the sponsor.
- Safety and feasibility of a novel transcervical access neuroprotection system for carotid artery stenting in the PROOF Study.Link provided by the sponsor.
Related trials for Carotid Artery Diseases
Not yet recruitingObservational study
CAROTID DOPPLER AND CEREBRAL OXIMERY IN POST CARDIAC ARREST ICU PATIENTS
Cardiac Arrest (CA), Carotid Doppler
Active, not recruitingObservational study
Symptomatic Carotid Outcomes Registry
Carotid Stenosis, Ischemic Stroke
RecruitingObservational study
Estimated Risk of Preeclampsia in the First Trimester and Its Association With Subclinical Atherosclerosis and Cardiovascular Risk in Women With Type 1 Diabetes
Type 1 Diabetes, Preeclampsia
Not yet recruitingObservational study
PET-MR Imaging of Natriuretic Peptide Receptor C (NPR-C) in Carotid Atherosclerosis With 64Cu-NODAGA-CANF (Multisite)
Carotid Atherosclerosis, Carotid Artery Stenosis Asymptomatic
Not yet recruiting
UltraTrac for Cardiac Output Monitoring in Congenital Heart Disease
Congenital Heart Disease, Cardiac Output
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Sumaira Macdonald, MD, PhD study chair
Chief Medical Officer
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Silk Road Embolic Protection System in people with Carotid Artery Diseases, run by Silk Road Medical at 1 site in Germany.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 7 inclusion and 30 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 17 Feb 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 8 Jul 2019). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Safety Evaluation as Composite of Occurrences of Major Stroke, Myocardial Infarction and Death (time frame: 0 days post-procedure to 30 days post-procedure). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01264419, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Feb 2020.