Knee Meniscus TearNCT01270919

A Prospective, Post-market, Multi-center Feasibility Study of the BioDuct® Meniscal Repair Device

A study testing BioDuct Meniscal Repair Device in people with Knee Meniscus Tear, run by Stryker Orthopaedics at 3 sites in United States.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

To demonstrate repair of the meniscus at 6 months, as evaluated by MRI, will be observed; and clinical qualitative assessments will improve from preoperative to postoperative time points with the BioDuct® Meniscal Repair Device. Read more about this study

Who is it for?
Ages 18 to 45 years
Conditions the study is for
Knee Meniscus Tear
What is being tested?
BioDuct Meniscal Repair Device
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
1 participants
Where
3 sitesUnited States
Study dates
Nov 2010to May 2011
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 45 years
  • All sexes
  • No healthy volunteers
  • Adult

Who may be able to join

  • A. Patient has signed an IRB approved, study specific Informed Patient Consent Form.
  • B. Patient is a male or non-pregnant female age 45 years or younger at time of study device implantation.
  • C. Patient is a candidate for repair of one longitudinal vertical tear (bucket handle) fully located in the red-white (vascular-avascular) zone of the meniscus (3-5 mm from the synovial-meniscus junction) or repair of one longitudinal vertical tear (bucket handle) primarily located in the red-white zone of the meniscus, but partially (< 30% of total length) extending into the red zone (< 3 mm from the synovial-meniscus junction) and/or into the white zone (> 5 mm from the synovial-meniscus junction).
  • D. Patient does not require more than three BioDuct® Meniscal Repair Devices for the meniscal tear.
  • E. Patient requires suture only for fixation at the site where the study device will be used.
  • F. Patient is willing and able to comply with postoperative scheduled MRI and clinical evaluations and rehabilitation.

Who cannot join

  • G. Patient has a Body Mass Index (BMI) > 35.
  • H. Patient has an active or suspected latent infection in or about the affected knee joint at time of study device implantation.
  • I. Patient has horizontal, transverse, degenerative complex tears.
  • J. Patient has ACL and/or PCL deficiencies within the operative knee and is not undergoing concomitant repair of these deficiencies.
  • K. Patient requires bilateral meniscal repair.
  • L. Patient requires meniscectomy.
Show all 11Show fewer
  • M. Patient presents with abnormal degenerative osteoarthritis of the joint [e.g. International Cartilage Repair Society (ICRS) Grade III or higher and/or Modified Outerbridge Grade III or higher].
  • N. Patient has undergone previous meniscal repair to the operative knee.
  • O. Patient has a knee joint with greater than 5º anatomic axis misalignment.
  • P. Patient has active synovitis.
  • Q. Patient is a prisoner.

Trial locations and contacts

3 sites in 1 country.

United States3 sites
  • Jack Farr, M.D.

    Indianapolis, Indiana, 46237

  • Randall Holcomb

    Memphis, Tennessee, 38120

  • Jason Scopp, M.D.

    Salisbury, Maryland, 21804

Other trials in United States

About this study

Official title: This Study Will be a Prospective, Non-randomized Evaluation of the Change Between Preoperative and Postoperative Outcomes for Those Who Receive the BioDuct® Device Meniscal Repair Device.

To demonstrate repair of the meniscus at 6 months, as evaluated by MRI, will be observed; and clinical qualitative assessments will improve from preoperative to postoperative time points with the BioDuct® Meniscal Repair Device.

Read the detailed description

To demonstrate repair of the meniscus 6 months postimplantation of the BioDuct® Meniscal Repair Device, utilizing MRI.

To evaluate clinical success by comparing the following qualitative criteria at 2 years postoperative to preoperative findings: effusion, swelling, pain, catching, locking, focal joint line pain and mechanical symptoms, if present preoperative. Clinical success is defined as no worsening for any of these criteria and improvement in at least one of these criteria.

Being tested
BioDuct Meniscal Repair Device

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • BioDuct Meniscal Repair DeviceDevice

    The BioDuct® Meniscal Repair Device is a small, cannulated, arthroscopically implanted, bioabsorbable conduit that has length sizes of 5, 7 and 9 mm. Based on the concept of trephination for treating meniscal tears in the red-white zone, the BioDuct® Meniscal Repair Device is designed to create a vascular access channel between the vascular-rich and cell-rich synovium and the meniscal tear. This channel allows for the flow of blood from the vascular to the avascular tissue to promote repair of the meniscus.

    The BioDuct® Meniscal Repair Device is not used across meniscal tears, like other fixation devices. The BioDuct® Meniscal Repair Device is used in conjunction with suturing and helps provide vascular access, while the sutures help provide fixation. Based on the Inclusion Criteria of this protocol, there can be a maximum of three BioDuct® Meniscal Repair Devices utilized for the meniscal tear.

Study groups in NCT01270919
Study groupRoleWhat they receive
BioDuct Meniscal Repair DeviceOtherBioDuct Meniscal Repair Device
Receives: Device: BioDuct Meniscal Repair Device

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. To Demonstrate Repair of the Meniscus 6 Months Post-implantation of the BioDuct® Meniscal Repair Device, Utilizing MRI. To Evaluate Clinical Success Using Postoperative Qualitative Criteria, as Compared to Preoperative Findings.

    Measured: 2 years

Secondary outcomes (1)
  1. To Evaluate the Change in Outcomes From the Preoperative Time Point to Postoperative Time Points in Cases Implanted With the BioDuct® Meniscal Repair Device Using the SF-12, VAS Pain, WOMET and IKDC Subjective Knee Evaluation.

    Measured: Postoperative compared to preoperative

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Jan 2011 (estimated)
  2. Study startNov 2010
  3. Primary completionMay 2011
  4. Study completionMay 2011

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
1 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01270919
Sponsor's protocol ID
73
Status last verified
May 2014
First submitted
4 Jan 2011
Last updated
24 Jun 2014
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing BioDuct Meniscal Repair Device in people with Knee Meniscus Tear, run by Stryker Orthopaedics at 3 sites in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 24 Jun 2014. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 24 Jun 2014). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

To Demonstrate Repair of the Meniscus 6 Months Post-implantation of the BioDuct® Meniscal Repair Device, Utilizing MRI. To Evaluate Clinical Success Using Postoperative Qualitative Criteria, as Compared to Preoperative Findings. (time frame: 2 years). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Jun 2014; AzTrials last refreshed its copy on 6 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in