Aortic Aneurysm, ThoracicNCT01357590
Evaluation of Thoraflex in the Treatment of Aneurysm or Penetrating Ulcer of the Descending Thoracic Aorta
A study testing Thoracic Endovascular Stent Graft System (ThoraflexTM) in people with Aortic Aneurysm, Thoracic and Penetrating Aortic Ulcers (PAUs), run by Vascutek Ltd. at 28 sites in 7 countries.
Trial summary
ThoraflexTM is designed for the treatment of aneurysm or penetrating ulcer of the descending thoracic aorta. Each system is advanced from a transfemoral or transiliac approach over a 0.035" guidewire and positioned under fluoroscopic control. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Aortic Aneurysm, Thoracic, Penetrating Aortic Ulcers (PAUs)
- What is being tested?
- Thoracic Endovascular Stent Graft System (ThoraflexTM)
- Type of treatment
- Medical device
- How many people
- 0 participants
- Where
- 28 sitesin 7 countries
- Study dates
- Start not givento not given
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Subject aged > 18 years
- Subject has a life expectancy of at least 12 months
- The Subject must meet at least one of the following:
- Descending thoracic fusiform aneurysm, 50mm in diameter or greater. ONLY FOR FRENCH SITES: Descending thoracic fusiform aneurysm, 5.5cm in diameter or greater.
- Descending thoracic aneurysm that is 4cm or more in diameter that has increased in size by 0.5cm in last 6 months. ONLY FOR FRENCH SITES: Descending thoracic aneurysm that is 4cm or more in diameter that has increased in size by 1cm in the last year
- Descending thoracic aneurysm with a maximum diameter that exceeds two times the diameter of the non-aneurysmal, adjacent aorta
Show all 13Show fewer
- Saccular aneurysm in the descending thoracic aorta or Penetrating Atherosclerotic Ulcers (PAUs). ONLY FOR FRENCH SITES: Saccular aneurysm in the descending thoracic aorta, Penetrating Atherosclerotic Ulcers (PAUs) with associated Intramural Haematoma, or Atherosclerotic Giant PAU
- Subject must have proximal and distal aortic neck suitable for stent graft placement with vessel diameter ranging between 22.0 - 35.0 mm.
- The length of attachment zones will depend on the intended stent graft diameter. For left subclavian artery (LSA) in superior position: The proximal attachment zone should be 10mm for 28mm graft, 11mm for 30mm, 12mm for 32mm - 34mm grafts, 14mm for 36mm - 38mm grafts and 15mm for 40mm graft. For LSA in non-superior position: The proximal attachment zone should be 15mm for 28mm graft, 17mm for 30mm, 20mm for 32mm - 34mm grafts, 23mm for 36mm - 38mm grafts and 25mm for 40mm graft. The distal attachment zone should be 40mm.
- The diagnosis is confirmed as thoracic aortic aneurysm or PAU by contrast enhanced CT obtained within the three months prior to implant.
- Access vessels: Adequate iliac/femoral access -able to accommodate 23 (7.7 mm) or 25 OD French size (8.3 mm) introducer systems, with or without the use of an arterial conduit.
- Subject is able and willing to comply with the protocol and associated follow-up requirements
- Subject or legal representative must have agreed to participate voluntarily and have signed and dated an Ethics Committee/Ethical Review Board approved Patient Informed Consent form.
Who cannot join
- Subject has any of the following conditions in his/her descending thoracic aorta:
- Dissections - acute or chronic, in ascending or descending aorta
- Acute Transection or Acute Traumatic Injury
- Pseudoaneurysm (false aneurysm)
- Symptomatic Aneurysm, including ruptured lesions
- Subject's proximal neck diameter measures < 22.0 or > 35.0 mm.
Show all 29Show fewer
- Subject's distal neck diameter measures < 22.0 or > 35.0 mm.
- Subject has prohibitive calcification (>50% circumferential calcification), occlusive disease, or tortuosity of intended fixation sites.
- Subject has circumferential thrombus (>50%) in region of intended fixation sites.
- Subject has an increasing tapered proximal neck with ≥3mm increase in diameter from proximal fixation site to the aneurysm.
- Subject has a decreasing tapered distal neck with ≥3 mm increase in diameter from distal fixation site to the aneurysm.
- Subject's aneurysm or distal thoracic aortic neck angle precludes advancement of the introduction system and device.
- Subject has an anatomical variance which would compromise circulation to the carotids, vertebral, or innominate arteries after device placement that is not amenable to subclavian revascularisation. This would not apply to Subjects with occluded celiac arteries.
- Subject is pregnant.
- Subject is morbidly obese preventing adequate x-ray visualization of the aorta.
- Subject has known or suspected connective tissue disorder (e.g., Marfan's syndrome, Ehlers-Danlos syndrome).
- Subject has a blood coagulation disorder or bleeding diathesis in which the treatment cannot be suspended for one week pre and post repair.
- Subject has coronary artery disease with unstable angina and who has not received coronary revascularisation within the last 3 months.
- Subject has chronic obstructive pulmonary disease requiring the routine need for oxygen therapy outside the hospital setting (e.g., daily or nightly home use).
- Subject is in acute renal failure or renal insufficiency with a creatinine ≥ 2.5 mg/dL and is not on renal replacement therapy or dialysis.
- Subject has active systemic infection and/or mycotic aneurysms.
- Subject has had a stroke within 3 months of the treatment date.
- Subject has less than one-year life expectancy as evidenced by factors prohibiting major medical intervention (e.g., presence of malignant tumour, advanced age, etc.).
- Subject is participating in another research study.
- Subject has a co-existing abdominal aortic aneurysm (AAA) in which the investigator believes requires concomitant treatment within 45 days.
- Subject has had a prior AAA repair (endovascular or surgical) that was performed less than 6 months prior to enrolment.
- Subject has had a prior endovascular repair (e.g., stent, stent-graft) in the descending thoracic aorta. The device may not be placed within any prior surgical graft.
- Subject has an untreatable allergy or sensitivity to contrast media or device components.
- Subject has been admitted to the hospital for a major surgical or medical procedure within45 days of the planned procedure or is planning to undergo other major surgical or medical procedure within 45 days post implantation (e.g., coronary artery bypass graft [CABG], organ transplantation, etc.). This excludes any planned procedures for the prospective stent-graft placement (e.g. common carotid to left subclavian transposition/bypass, left carotid to axillary bypass, etc. are acceptable. Carotid-carotid bypasses are not permitted).
Trial locations and contacts
28 sites in 7 countries.
28 sites in 7 countries
Germany6 sites
RWTH Aachen, University Hospital Aachen
Aachen, 52074
Harzzentru der Universitatsklinik Koln
Cologne, 50924
Universitatsklinikum Freiburg
Freiburg im Breisgau, 79106
Department of Vascular Medicine
Hamburg, 20246
MH Hannover
Hanover, 30625
Klinikum rechts der Isar
Munich, 81675
Netherlands5 sites
VUmc, Department of Surgery
Amsterdam, 1081 HV
Academic Medical Centre (AMC), Department of Surgery
Amsterdam, 1105 AZ
Medisch Specturm Twente, Department of Surgery
Enschede, 7513 ER
University of Maastricht, Department of Surgery
Maastricht, 6229 HX
Erasmus Medical Centre, Department of Surgery
Rotterdam, 3015 CE
Canada4 sites
Peter Lougheed Centre
Calgary, AB T1Y 6J4
Institute University de Cardiologie et de
Québec, G1V 4G5
Sunnybrook Health Sciences Centre
Toronto, M4N 3M5
St Michael's Hospital
Toronto, ON M5B 1W
United Kingdom4 sites
Royal Infirmary of Edinburgh
Edinburgh, Scotland, ED16 4SA
Western Infirmary
Glasgow, G11 6NT
Leeds General Infirmary
Leeds, England, LS1 3EX
St Thomas' Hospital
London, SE1 7EH
Belgium3 sites
Cliniques Universitaires Saint-Luc (UCL)
Brussels, B-1200
UZ Gent
Ghent, B-9000
UZ (Universitair Ziekenhuis) Leuven
Leuven, 3000 Leuven
France3 sites
Service de Chirurgie Cardaque et Vasculaire
Bordeaux, 33 604
Hopital Europeen Georges Pompidou
Paris, 75908
Service de Radiologie
Toulouse, 31403
Italy3 sites
Universita di Bologna
Bologna, 41038
University of Florence
Florence, 50134
Dipartimento Cardioscienze
Rome, 00152
About this study
Official title: Evaluation of the Vascutek Ltd. Thoracic Endovascular Stent Graft System (ThoraflexTM)in the Treatment of Aneurysm or Penetrating Ulcer of the Descending Thoracic Aorta
ThoraflexTM is designed for the treatment of aneurysm or penetrating ulcer of the descending thoracic aorta. Each system is advanced from a transfemoral or transiliac approach over a 0.035" guidewire and positioned under fluoroscopic control. If necessary, an arterial conduit technique may be required to allow access to the arterial system. The soft tapered tip allows atraumatic insertion into the vessel, while the catheter and sheath are designed to provide excellent flexibility and control through tortuous arterial anatomy.
Each individual stent graft device is supplied sterile and pre-loaded in a single-use delivery system. The stent graft is a self-expanding endoprosthesis constructed of a thin wall woven polyester and nitinol ring stents, which are attached to the fabric with braided polyester sutures. The delivery system central catheter is a stainless steel braided co-extrusion of polytetrafluoroethylene (PTFE) and polyester elastomer, designed to provide significant torque control and strength, while also maintaining superior flexibility. The outer sheath is made in a tri-layer construction consisting of a PTFE liner, a stainless steel flat braid layer and a polyester elastomer outer jacket with a hydrophilic lubricant coating. These materials provide very low friction force during device insertion and deployment together with enhanced flexibility of the delivery system. The handle components are moulded from thermoplastic polyurethane.
Read more
The materials of the endoprosthesis are identical to those of the current Conformité Européenne (CE) marked Vascutek Ltd. AnacondaTM Stent Graft System intended for abdominal aortic aneurysm repair. The materials of the delivery system are well established in medical applications. The design of ThoraflexTM is based on the same principles as other clinically established thoracic endovascular devices. The endoprosthesis is constructed of self-expanding nitinol stents and a polyester tube graft. Four proximal hooks anchor the endoprosthesis within the aorta. Unlike existing thoracic endovascular devices, the delivery system of ThoraflexTM allows repositioning of the endoprosthesis so that the optimal deployment position can be enhanced.
The intended use of ThoraflexTM is the treatment of aneurysm or penetrating ulcer of the descending thoracic aorta, which is identical to other CE approved thoracic endovascular devices.
- Being tested
- Thoracic Endovascular Stent Graft System (ThoraflexTM)
- Keywords
- aneurysm, penetrating ulcer, descending thoracic aorta
- Medical subject headings
- Aortic Aneurysm, Thoracic, Penetrating Atherosclerotic Ulcer, Aneurysm
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Thoracic Endovascular Stent Graft System (ThoraflexTM)Device
Thoracic Endovascular Stent Graft System
What is being measured
The primary outcome is the main question the study is designed to answer.
Successful aneurysm/PAU treatment, defined as a composite endpoint of Subjects who have successful delivery and deployment of the ThoraflexTM at the initial procedure and are free from the following;
- Aneurysm growth (greater than or equal to) 5mm from baseline measurement
- Post-operative interventions to correct type I or III endoleaks
- Conversion to open surgical repair
- Failed patency of the stent graft
- Migration requiring secondary intervention
- Significant failure of stent graft integrity
- Aneurysm rupture
Measured: (less than or equal to) 365 days post-procedure
Secondary outcomes (3)
Incidence of type I or III endoleak. The incidence of Subjects with freedom from type I and III endoleaks will be the focus of assessments; however type II and IV endoleaks will be recorded and evaluated for rates of occurrence
Measured: First 24 hour post-operative period (defined on procedural angiography)
Stent graft patency, described as the presence of blood flow within the graft as determined through imaging analysis
Measured: First 24 hour post-operative period (defined on procedural angiography)
Conversion to surgical repair
Measured: First 24 hour post-operative period (defined on procedural angiography)
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted20 May 2011 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Aortic Aneurysm, ThoracicStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 0 participants (actual)
Sponsor and investigators
- Lead sponsor
- Vascutek Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01357590
- Sponsor's protocol ID
- TAA-001
- Status last verified
- Mar 2012
- First submitted
- 17 May 2011
- Last updated
- 2 Mar 2012
- Results posted
- No
- Data monitoring committee
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 2 Mar 2012. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of the Vascutek Ltd. Thoracic Endovascular Stent Graft System (ThoraflexTM)in the Treatment of Aneurysm or Penetrating Ulcer of the Descending Thoracic Aorta
- ClinicalTrials.gov ID
- NCT01357590
- Acronym / sponsor ID
- TAA-001
- Keywords
- aneurysm, penetrating ulcer, descending thoracic aorta
- Study type
- Interventional
- Recruitment status
- Withdrawn
- Enrolment
- 0 participants (actual)
- Lead sponsor
- Vascutek Ltd.Industry (pharma, biotech, devices)
- First posted
- 20 May 2011 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
ThoraflexTM is designed for the treatment of aneurysm or penetrating ulcer of the descending thoracic aorta. Each system is advanced from a transfemoral or transiliac approach over a 0.035" guidewire and positioned under fluoroscopic control. If necessary, an arterial conduit technique may be required to allow access to the arterial system. The soft tapered tip allows atraumatic insertion into the vessel, while the catheter and sheath are designed to provide excellent flexibility and control through tortuous arterial anatomy.
Each individual stent graft device is supplied sterile and pre-loaded in a single-use delivery system. The stent graft is a self-expanding endoprosthesis constructed of a thin wall woven polyester and nitinol ring stents, which are attached to the fabric with braided polyester sutures. The delivery system central catheter is a stainless steel braided co-extrusion of polytetrafluoroethylene (PTFE) and polyester elastomer, designed to provide significant torque control and strength, while also maintaining superior flexibility. The outer sheath is made in a tri-layer construction consisting of a PTFE liner, a stainless steel flat braid layer and a polyester elastomer outer jacket with a hydrophilic lubricant coating. These materials provide very low friction force during device insertion and deployment together with enhanced flexibility of the delivery system. The handle components are moulded from thermoplastic polyurethane.
The materials of the endoprosthesis are identical to those of the current Conformité Européenne (CE) marked Vascutek Ltd. AnacondaTM Stent Graft System intended for abdominal aortic aneurysm repair. The materials of the delivery system are well established in medical applications. The design of ThoraflexTM is based on the same principles as other clinically established thoracic endovascular devices. The endoprosthesis is constructed of self-expanding nitinol stents and a polyester tube graft. Four proximal hooks anchor the endoprosthesis within the aorta. Unlike existing thoracic endovascular devices, the delivery system of ThoraflexTM allows repositioning of the endoprosthesis so that the optimal deployment position can be enhanced.
The intended use of ThoraflexTM is the treatment of aneurysm or penetrating ulcer of the descending thoracic aorta, which is identical to other CE approved thoracic endovascular devices.
Study design
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Single group
- Masking
- None (open label)
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (13 listed)
- Subject aged > 18 years
- Subject has a life expectancy of at least 12 months
- The Subject must meet at least one of the following:
- Subject must have proximal and distal aortic neck suitable for stent graft placement with vessel diameter ranging between 22.0 - 35.0 mm.
- The length of attachment zones will depend on the intended stent graft diameter. For left subclavian artery (LSA) in superior position: The proximal attachment zone should be 10mm for 28mm graft, 11mm for 30mm, 12mm for 32mm - 34mm grafts, 14mm for 36mm - 38mm grafts and 15mm for 40mm graft. For LSA in non-superior position: The proximal attachment zone should be 15mm for 28mm graft, 17mm for 30mm, 20mm for 32mm - 34mm grafts, 23mm for 36mm - 38mm grafts and 25mm for 40mm graft. The distal attachment zone should be 40mm.
Key exclusion criteria (29 listed)
- Subject has any of the following conditions in his/her descending thoracic aorta:
- Subject's proximal neck diameter measures < 22.0 or > 35.0 mm.
- Subject's distal neck diameter measures < 22.0 or > 35.0 mm.
- Subject has prohibitive calcification (>50% circumferential calcification), occlusive disease, or tortuosity of intended fixation sites.
- Subject has circumferential thrombus (>50%) in region of intended fixation sites.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Thoracic Endovascular Stent Graft System (ThoraflexTM)Thoracic Endovascular Stent Graft System | Device | – |
Primary outcome
Successful aneurysm/PAU treatment, defined as a composite endpoint of Subjects who have successful delivery and deployment of the ThoraflexTM at the initial procedure and are free from the following;
Time frame: (less than or equal to) 365 days post-procedure
1. Aneurysm growth (greater than or equal to) 5mm from baseline measurement 2. Post-operative interventions to correct type I or III endoleaks 3. Conversion to open surgical repair 4. Failed patency of the stent graft 5. Migration requiring secondary intervention 6. Significant failure of stent graft integrity 7. Aneurysm rupture
3 secondary outcomes
Incidence of type I or III endoleak. The incidence of Subjects with freedom from type I and III endoleaks will be the focus of assessments; however type II and IV endoleaks will be recorded and evaluated for rates of occurrence
Time frame: First 24 hour post-operative period (defined on procedural angiography)
Stent graft patency, described as the presence of blood flow within the graft as determined through imaging analysis
Time frame: First 24 hour post-operative period (defined on procedural angiography)
Conversion to surgical repair
Time frame: First 24 hour post-operative period (defined on procedural angiography)
Results and safety
The study was withdrawn before enrolling participants, so there are no results.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 2 Mar 2012.
Related trials for Aortic Aneurysm, Thoracic
Recruiting
Treatment in Thoracic Aortic Aneurysm: Surgery vs Surveillance
Ascending Aortic Aneurysm Enlargement, Ascending Aorta Aneurysm
Recruiting
GORE® TAG® Thoracic Branch Endoprosthesis Zone 0/1 Post-Approval Study
Aortic Arch Dissection, Aortic Arch Aneurysm
RecruitingPhase 4
Effect of Remimazolam Versus Propofol Total Intravenous Anesthesia on Intraoperative Hemodynamic Stability in Patients Undergoing Thoracic or Abdominal Endovascular Aortic Repair
Aortic Aneurysm, Thoracoabdominal, Aortic Aneurysm, Abdominal
Not yet recruitingPhase 4
Effects of Remimazolam on Postoperative Cognitive Dysfunction and Neuroinflammatory Biomarkers in Patients Undergoing Aortic Arch Surgery
Aortic Aneurysm of the Proximal Arch, Aortic Aneurysms Arch
Enrolling by invitation
Endovascular Treatment of Thoracic Aortic Disease
Thoracic Aortic Aneurysms, Dissecting, Aneurysm
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
28 sites in 7 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Thoracic Endovascular Stent Graft System (ThoraflexTM) in people with Aortic Aneurysm, Thoracic and Penetrating Aortic Ulcers (PAUs), run by Vascutek Ltd. at 28 sites in 7 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 13 inclusion and 29 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: withdrawn, as of the sponsor's last update on 2 Mar 2012. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 28 sites in Germany, Netherlands, Canada, United Kingdom, Belgium and 2 more countries. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was withdrawn before enrolling participants, so there are no results.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Successful aneurysm/PAU treatment, defined as a composite endpoint of Subjects who have successful delivery and deployment of the ThoraflexTM at the initial procedure and are free from the following; (time frame: (less than or equal to) 365 days post-procedure). It is what the study was designed to measure, not a finding.