AzTrials
AzTrials

EV71NCT01388049

e- Ab Sensor - Based Real-time Diagnosis of Enterovirus Type 71

A study testing Electrosensing antibody probing system (e- Ab sensor) in people with EV71, run by National Taiwan University Hospital at 1 site in Taiwan.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

To develop a real-time diagnostic technique with e- Ab sensor for Entervirus 71 detection, the investigators conduct a prospective clinical study. In comparison with results from direct sequencing of Entervirus 71, the investigators evaluate the performance of e- Ab sensor, including reproducibility, sensitivity… Read more about this study

Who is it for?
Any age
Conditions the study is for
EV71
What is being tested?
Electrosensing antibody probing system (e- Ab sensor)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
72 participants
Where
1 siteTaiwan
Study dates
Jul 2010to Jul 2013
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • A: The patients with confirmed or suspected infection.
  • B: The patients without disease.

Who cannot join

  • Patients will be excluded if they couldn't sign the consent.

Trial locations and contacts

1 site in 1 country.

Taiwan1 site, 1 recruiting
  • National Taiwan University Hospital

    Taipei, 10051

    Luan-Yin Chang, MD,PhD, 886-2-2312-3456 ext. 71528, lychang@ntu.edu.tw

    Luan-Yin Chang, MD/PhD

    Recruiting

Other trials in Taiwan

About this study

To develop a real-time diagnostic technique with e- Ab sensor for Entervirus 71 detection, the investigators conduct a prospective clinical study. In comparison with results from direct sequencing of Entervirus 71, the investigators evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction. The potential factors which may interfere with the results would be investigated. With such technique, the investigators hope to make early diagnosis and give EV71 patients early treatment to reduce the complications and case-fatality rate.

Read the detailed description

Entervirus 71 is one of the most important infectious diseases in children and the important concern in public health. Since 1998, EV71 has become an endemic disease in Taiwan and caused hundreds of severe cases and dozens of fatal cases each year due to lack of EV71 vaccine. Family transmission study also showed that it is highly contagious among households as well as in daycares or kindergartens. Therefore, a rapid diagnosis is clinically necessary and can provide clinicians the rapid answers and make early treatment possible to reduce the complications and case-fatality rate. In addition, early diagnosis of the patients will alert parents and public health workers to prevent the contacts earlier and to limit the EV71 spread.

Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins or viral antigen in medical samples, will be used for analyzing the interaction kinetics between Q.anti-EV71 and its antigen EV71 present in EV71 patients and normal sample. The system incorporates the use of engineered semiconductive antibodies or virus in vertical and lateral chip (eVchip) or lateral flow through (eVsignal) formats. In electrosensing virus probing, semiconductive antibodies are bound as a suitable electrosensing probe which specifically and selectively binds EV71 epitope target molecules in the test serum. In comparison with results from direct sequencing of EV71, the investigators evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction. The potential factors which may interfere with the results would be investigated. e- Ab sensor threshold decisions must maximize its sensitivity. Therefore, the threshold value in the test group is to find the decision could have 90% sensitivity and 90% specificity. With such technique, the investigators hope to make early diagnosis and give EV71 patients early treatment to reduce the complications and case-fatality rate.

Conditions
EV71
Being tested
Electrosensing antibody probing system (e- Ab sensor)
Keywords
EV71

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Electrosensing antibody probing system (e- Ab sensor)Device

    Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins, or viral antigen in medical samples, will be used for analyzing the interaction kinetics between anti-EV71 antibody and its antigen (EV71) present in patients. The system incorporates the use of engineered semiconducive antibodies or virus in vertical and lateral chip (eAbchip) or lateral flow through (eAbsignal) formats. In electrosensing antibody probing, semiconductive antibodies are bound as a suitable electrosensing probe, which specifically and selectively binds targeted molecules (EV71) in the test specimens. From assessment of the electric signature of semiconductive anti-EV71 antibodies, the eABprobe could offer sensitive detection and precise quantification of EV71.

Study groups in NCT01388049
Study groupRoleWhat they receive
virus detectionExperimentalNot described
Receives: Device: Electrosensing antibody probing system (e- Ab sensor)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The performance of e- Ab sensor

    In comparison with results from direct sequencing of EV71, we evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction.

    Measured: 1 Day

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Jul 2011 (estimated)
  2. Study startJul 2010
  3. Primary completionJul 2013 (estimated)
  4. Study completionJul 2013 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
Double blind
Who is masked
Investigator, Outcomes assessor
Enrolment
72 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01388049
Sponsor's protocol ID
201007053R
Status last verified
Nov 2011
First submitted
1 Jul 2011
Last updated
27 Dec 2012
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Electrosensing antibody probing system (e- Ab sensor) in people with EV71, run by National Taiwan University Hospital at 1 site in Taiwan.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 27 Dec 2012. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Taiwan. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Shiming Lin, PhD (886-2-23123456 ext. 88458, til@ntu.edu.tw), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The performance of e- Ab sensor (time frame: 1 Day). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Dec 2012; AzTrials last refreshed its copy on 30 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in