AzTrials
AzTrials

Coronary Artery DiseaseNCT01434641

Rapid Stress/Rest Single-Day Tc-99m Sestamibi Myocardial Single Photon Emission Computed Tomography

A study testing low-dose stress MPI SPECT in people with Coronary Artery Disease, run by St. Luke's-Roosevelt Hospital Center at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This protocol details a novel myocardial perfusion Single Photon Emission Computed Tomography (SPECT) protocol wherein patients receive a low-dose (6 mCi) of Tc-99m sestamibi during exercise or regadenoson pharmacologic stress and undergo a full-time SPECT acquisition processed with Wide Beam Reconstruction (WBR). Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Coronary Artery Disease
What is being tested?
low-dose stress MPI SPECT
Could I receive a placebo?
No, everyone receives an active treatment
How many people
102 participants
Where
1 siteUnited States
Study dates
Jul 2011to Mar 2012
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • adult
  • not pregnant
  • suspected coronary artery disease

Who cannot join

  • pregnant
  • under 18 years of age

Trial locations and contacts

1 site in 1 country.

United States1 site
  • 'St. Luke's-Roosevelt Hospital

    New York, New York, 10025

Other trials in United States

About this study

Official title: Rapid Stress/Rest Single-Day Tc-99m Sestamibi Myocardial SPECT

This protocol details a novel myocardial perfusion Single Photon Emission Computed Tomography (SPECT) protocol wherein patients receive a low-dose (6 mCi) of Tc-99m sestamibi during exercise or regadenoson pharmacologic stress and undergo a full-time SPECT acquisition processed with Wide Beam Reconstruction (WBR). Immediately thereafter patients receive a high-dose (30-35 mCi) of Tc-99m sestamibi at rest and undergo a half-time rest scan, also processed with WBR. All enrolled research subjects will undergo both the initial stress and subsequent rest scan.

The radiation exposure associated with this new stress/rest protocol is equivalent to that of the conventional rest/stress protocol presently in routine clinical uses at SLRHC.

Read more

Eventually, when and if this novel stress/rest protocol is adopted in routine clinical practice, patients with normal stress scans would receive only 6 mCi of Tc-99m sestamibi (331 mSv in men, 241 mSv in women) and spend only approximately one hour in the Nuclear Medicine Laboratory.

All patients presenting to the Nuclear Medicine Laboratory for evaluation of known or suspected coronary artery disease will be candidates for enrollment. Fifty patients undergoing treadmill exercise stress and 50 patients undergoing regadenoson pharmacologic stress will be enrolled. Pregnant and breast-feeding patients will not be eligible.

Read the detailed description

Specific Aims:

To validate acceptable image quality and the stress/rest myocardial count density ratio (as defined below) of the Rapid Stress/Rest Protocol

Experimental Design and Methods:

Validation of the stress/rest myocardial count density ratio achieved using a standard rest/stress protocol incorporating a conventional 3:1 stress/rest Tc-99m radiopharmaceutical dose ratio.

Human subjects:

To determine the stress/rest myocardial count density ratio encountered using existing rest/stress imaging protocols in routine clinical practice, 100 consecutive patients undergoing either exercise or pharmacologic stress (dipyridamole or regadenoson) myocardial perfusion SPECT were included. The stress/rest Tc-99m sestamibi/Tc-99m tetrofosmin radiopharmaceutical dose ratio was 3:1 in all patients. Stress and rest maximal myocardial counts were determined from reconstructed tomograms using Evolution software (GE Healthcare).

The Investigational, novel stress/rest protocol:

Human Subjects: Characteristics and Plans for Recruitment 100 patients, who give their consent, presenting for myocardial perfusion SPECT in whom exercise or pharmacologic stress is clinically indicated will be enrolled prospectively. There will be no bias in selection of patients with regard to gender or racial/ethnic composition. 50 patients will be stressed with exercise. 50 additional patients will receive pharmacologic stress with the on-label dose of Regadenoson. All patients will receive the appropriate dose of radiotracer according to their size and weight. Pregnant women and those who are breast feeding will not be enrolled.

Patient Informed Consent:

Written informed consent will be obtained by either the Principal Investigator, the PI's research assistant (a physician), a Nuclear Medicine resident, or a Cardiology fellow (who will supervise and monitor the stress testing).

Methods - Imaging and Data Analysis:

The rapid stress/rest protocol, as described above, will be performed using the GE Ventri, MG or Maxxus dual-head supine scintillation camera and UltraSPECT Wide Beam Reconstruction (WBR) software. Both stress and rest SPECT will be performed in all patients, even if the initial stress images are normal.

Images will be interpreted and reported in the standard fashion for clinical patient management, characterizing perfusion defects in terms of location, extent, severity, reversibility, and function in terms of volume, regional wall motion and wall thickening.

Patient flow:

  1. Upon arrival in the Nuclear Medicine Laboratory, patients will be interviewed regarding their medical history and a limited physical examination will be performed (as routinely performed for all clinically-indicated myocardial perfusion scans), and informed consent will be obtained for enrollment in this research study.
  2. Patients able to perform treadmill exercise to 85% of their age-predicted maximum heart rate will undergo treadmill exercise stress. In the remainder of patients pharmacologic stress will be achieved with intravenous regadenoson. A stress dose of 5-7 mCi (adjusted for patient weight and chest circumference) Tc-99m sestamibi will be administered intravenously.
  3. Post-stress gated SPECT will be acquired 30-60 min. thereafter using a full-time stress (12 min.) acquisition protocol, and processed using "half-time" Wide Beam Reconstruction software (i.e."half-dose" WBR protocol).
  4. Within 60 minutes thereafter patients will receive an additional intravenous dose of 35-42 mCi (adjusted for patient weight and chest circumference) Tc-99m sestamibi at rest.
  5. Resting gated SPECT will be acquired 40-60 minutes thereafter using a half-time resting (7.5 min.) acquisition protocol, and processed using "half-time" Wide Beam Reconstruction software (i.e. half-time" WBR protocol).
  6. The estimated time for the entire study is approximately 3 hrs, which is slightly less than the time fro the standard rest/stress protocol the investigators now use.

Scans will be assessed for image quality using a 5-point subjective scale used in several reports the investigators have published previously (in references #2 and #3 below):

The image quality of the stress and rest perfusion tomograms and the gated tomograms is graded visually using a 5-point scale: 1 (poor) - 5 (excellent). Myocardial count density and uniformity, endocardial and epicardial edge definition, visualization and definition of the right ventricle, and background noise are parameters considered subjectively when grading image quality. In addition to those same attributes considered when grading the summed perfusion tomograms, the definition of the left ventricular cavity at end-systole and the temporal smoothness of the gated frames are also considered when grading the post-stress and rest gated images.

Stress and rest absolute myocardial count density and the stress:rest myocardial count density ratio will be determined from processed tomograms using General Electric Xeleris computer software. Count density is basically the "information density" of the scan. In general, as for all of nuclear imaging, the higher the count density, the better the image quality, the lower the incidence of scan artifacts, and the greater the clinical value of the scan.

The rest/stress myocardial count density ratio achieved using the novel low-dose stress/high-dose rest protocol will be compared to the stress/rest ratios achieved using conventional rest/stress protocols (described above). The unpaired Student's t-test will be used. In addition rest/stress count densities achieved using exercise (50 patients) and regadenoson (50 patients) with the novel protocol will be compared with stress/rest ratios achieved using standard rest/stress imaging in the exercise (59 patients) and regadenoson (29 patients) subgroups.

Primary Endpoint 1: Comparison of the myocardial count density ratio of the test group using the Rapid Protocol vs. the myocardial count density ratio of the Traditional protocol in the control group.

Secondary Endpoints

  1. Image quality
  2. # of patients with normal stress studies that may have had a stress-only study.
  3. Reduction in radiation exposure between Test (Rapid) and Control (Traditional) groups
  4. Comparison of absolute stress and rest myocardial count densities in Test and Control groups 5. Start to finish time, and potential cost savings between the two groups 6. Comparison of total radiopharmaceutical dose between the two groups

Study Duration:

1 year

Statistical Plan:

Primary endpoint: The individual stress and rest, as well as the stress:rest myocardial count density ratio will be determined from test group processed tomograms and compared with control group using UNPAIRED T TEST

Secondary: The image quality of the test group stress and rest perfusion tomograms and the gated tomograms will be graded visually using a 5-point scale: 1 (poor) - 5 (excellent), and compared with the control group using the UNPAIRED T TEST.

The overall reduction in radiation exposure to the test group will be analyzed using, as a comparator, the patient size and weight based radiopharmaceutical dose and imaging time used in a standard Stress/Rest Protocol.

The time and cost savings associated with forgoing the resting study in those patients with a normal stress scan will be calculated.

Based on a control group mean maximum contrast dose (MCD) of 4.4 and standard deviation of 9.5, this study will have greater than 80% power to detect a 0.3 difference in the MCD ratio. (Alpha=5%)

Being tested
low-dose stress MPI SPECT
Keywords
myocardial perfusion SPECT, wide beam reconstruction, Tc-99m sestamibi
Medical subject headings
Coronary Artery Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • low-dose stress MPI SPECTOther

    novel low-dose rest/high-dose Tc-99m sestamibi SPECT protocol with wide beam reconstruction SPECT processing

Study groups in NCT01434641
Study groupRoleWhat they receive
low-dose stress MPI SPECTOtherPatients will receive a low-dose stress/high-dose rest protocol. Subject results are compared to archived patients undergoing a standard protocol./
Receives: Other: low-dose stress MPI SPECT

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Myocardial Perfusion SPECT Image Quality 12 Minutes

    SPECT image quality realized using the stress/rest single-day protocol: 12- minute post-stress acquisitions If myocardial image quality is equivalent or superior to that encountered with standard myocardial perfusion SPECT performed using a standard low-dose rest/high-dose SPECT protocol and OSEM processing and if the rest/stress myocardial count density ratio is > 3.5 the outcome of a particular patient is judged to be favorable (acceptable).If either image quality is "poor" or if the rest/stress count density ratio is less than 3.5, the outcome is judged unfavorable.

    Measured: at 12 minutes

  2. Myocardial Perfusion SPECT Image Quality 16 Minutes

    SPECT image quality realized using the stress/rest single-day protocol: 16- minute post-stress acquisitions If myocardial image quality is equivalent or superior to that encountered with standard myocardial perfusion SPECT performed using a standard low-dose rest/high-dose SPECT protocol and OSEM processing and if the rest/stress myocardial count density ratio is > 3.5 the outcome of a particular patient is judged to be favorable (acceptable).If either image quality is "poor" or if the rest/stress count density ratio is less than 3.5, the outcome is judged unfavorable.

    Measured: at 16 minutes

Secondary outcomes (1)
  1. Rest/Stress Myocardial Count Density Ratio

    The rest and stress myocardial count densities are determined automatically using Evolution software on the GE Healthcare Xeleris Nuclear Medicine computer workstation. The ratio is calculated by simple division.

    Please not that patient outcomes are NOT measured in this research protocol.

    Measured: immediately following SPECT image processing (1 hour after the test)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Sep 2011 (estimated)
  2. Study startJul 2011
  3. Primary completionMar 2012
  4. Study completionMar 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
102 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01434641
Sponsor's protocol ID
REGA-10K09
Status last verified
Mar 2016
First submitted
29 Aug 2011
Last updated
11 Apr 2016
Data monitoring committee
No

Publications

  • DePuey EG, Ata P, Wray R, Friedman M. Very low-activity stress/high-activity rest, single-day myocardial perfusion SPECT with a conventional sodium iodide camera and wide beam reconstruction processing. J Nucl Cardiol. 2012 Oct;19(5):931-44. doi: 10.1007/s12350-012-9596-8. Epub 2012 Jul 10.

    PubMed 22777525

Questions about this trial

What is this clinical trial studying?

A study testing low-dose stress MPI SPECT in people with Coronary Artery Disease, run by St. Luke's-Roosevelt Hospital Center at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 11 Apr 2016. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 11 Apr 2016). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Myocardial Perfusion SPECT Image Quality 12 Minutes (time frame: at 12 minutes). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01434641, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Apr 2016.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in