AzTrials
AzTrials

Colonic NeoplasmsNCT01438645

ScopeGuide-assisted Colonoscopy Versus Conventional Colonoscopy

A study testing Olympus ScopeGuide in people with Colonic Neoplasms and Iron Deficiency Anemia, run by Christopher Teshima at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Colonoscopy is an established technology that enables doctors to obtain live video from inside patients' large intestines, which is essential for the diagnosis of numerous intestinal illnesses. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Olympus ScopeGuide
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
250 participants
Where
1 siteCanada
Study dates
Sep 2011to Dec 2012
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adult patient 18 years or older.
  • Able to read \& write English.
  • Undergoing colonoscopy at University of Alberta Hospital for any indication.

Who cannot join

  • Colonoscopy performed without prior purgative bowel prep.
  • Patient with active, ongoing lower GI bleeding.
  • Colonoscopy performed to attempt colonic decompression in acute colonic pseudo-obstruction (Ogilvie's syndrome).
  • Colonoscopy for which propofol sedation is required.
  • Inpatient colonoscopy performed by a trainee under staff supervision.
  • Patient with previous colonic surgery.
  • Patient with pacemaker or implantable cardioverter-defibrillator (ICD).

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • University of Alberta Hospital

    Edmonton, Alberta, T6G 2X8

Other trials in Canada

About this study

Official title: ScopeGuide-assisted Colonoscopy Versus Conventional Colonoscopy for Improved Endoscopic Performance and Enhanced Patient Experience

Colonoscopy is an established technology that enables doctors to obtain live video from inside patients' large intestines, which is essential for the diagnosis of numerous intestinal illnesses. It consists of a long, flexible tube fitted with a light-source and small video camera that transmits the images onto a display monitor. The doctor inserts the scope into the anus, moves it into the rectum and then guides it slowly through the entire colon. Because of the various twists and turns that are part of normal bowel anatomy, advancing the scope through the entire colon is not always successful and can become challenging when the scope forms loops inside the abdomen. Unfortunately, there is no way for the doctor to see the shape of the scope inside the body other than what is seen from the video at its front end, and so navigating the colon relies on instinct accumulated with experience and the "feel" of the scope as loops begin to form. This is important because not only can this loop formation cause pain, but it can also increase the likelihood of an incomplete test. Incomplete tests matter because a major reason for performing colonoscopy is colon cancer screening and surveillance; detecting early cancers at treatable stages and looking for polyps that may be pre-cancerous growths. When colonoscopy does not advance through the entire colon, parts are left unexamined where cancer may develop. A new technology called "ScopeGuide" has been developed that uses magnetic coils embedded within the scope to create a 3D image of the shape of the entire scope inside the body that is projected onto the monitor for the doctor to see. This will show if loops are forming and will provide information about how to eliminate loops once they have formed. In this research study, the investigators will compare colonoscopy with the assistance of ScopeGuide to colonoscopy performed in the standard fashion, to see if ScopeGuide results in more successful procedures that are easier for the doctor and more comfortable for patients.

Read the detailed description

Summary of Research Proposal

Background:

Colon and rectal cancer (CRC) is a leading cause of cancer-related morbidity and mortality in Canada. Colonoscopy is the preferred screening modality for CRC and has been shown to decrease the likelihood of developing CRC as well as CRC-related mortality, particularly through the detection and removal of potentially pre-cancerous polyps, with the aim of preventing colon cancer, and for the diagnosis of early stage CRC that is more likely to be treatable and result in long-term survival. However, recent evidence suggests that colonoscopy has not been as universally protective against CRC as had been previously hoped, particularly for proximal cancers located in the right colon. Theories as to why this might be the case include speculation about altered biology of cancers that develop in the proximal colon and technical issues relating to the performance of colonoscopy itself. In particular, one of the problems is incomplete colonoscopy that fails to examine the entire colon to the cecum, which may occur in 10-20% of cases. Furthermore, from a public health standpoint, a considerable proportion of the population remain averse to undergoing colonoscopy, particularly because of fears of procedure discomfort, decreasing the potential impact for overall CRC reduction. Thus, optimizing the technical performance of colonoscopy and improving its acceptance among patients is important for maximizing the possible benefits to society.

One of the most common reasons for incomplete colonoscopy is excessive internal looping of the endoscope. This looping has also been shown to be the major cause of patient discomfort during the procedure. Experts agree that colonoscopy is most successful at reaching the cecum and most comfortable for patients when the endoscope is kept in a straight position by minimizing loop formation and reducing loops once they have formed. Thus, identification and reduction of endoscope loops is critically important for the successful and comfortable completion of colonoscopy. Over the years, several techniques have emerged to overcome loop formation, including withdrawal of the endoscope with torque, abdominal wall pressure and patient position changes, yet these are all done in a "trial and error" fashion. Despite this limitation, these maneuvers form the cornerstones of current colonoscopy technique. Technological innovations such as smaller caliber "pediatric" colonoscopes and "variable stiffness" colonoscopes with adjustable rigidity have been introduced that have had moderate success in diminishing patient discomfort and increasing rates of colonoscopy completion. Yet despite these efforts to improve colonoscopy practice, the reality is that many procedures are still done poorly. An audit of all colonoscopies performed in Winnipeg from 2004 to 2006 demonstrated a dismal completion rate of only 65%. Thus, something more clearly needs to be done. In an effort to help improve colonoscopy from both the technical standpoint of the endoscopist and also the comfort level of patients, Olympus has redesigned a previously developed real-time imaging system that enables visualization of the shape of the entire endoscope while it is inside the patient's body. This technology, called ScopeGuide (Olympus America, Center Valley, PA), consists of electromagnetic coils embedded within the endoscope that are detected by an external receiver dish, generating a 3D representation of the endoscope that is displayed on a monitor. It is anticipated that by visualizing the entire scope as it moves through the body, endoscopists will gain useful visual information about loop formation and scope position that will enable greater technical success while creating a more comfortable patient experience.

Study Objectives:

The purpose of this project is to perform a randomized, non-blinded colonoscopy study to determine if real time visualization of the colonoscope using the new Olympus ScopeGuide system is superior to conventional colonoscopy for the achievement of endoscopic procedural outcomes and for an improved patient experience in terms of reduced discomfort and decreased sedation requirements.

Methods:

Consecutive patients referred for colonoscopy at the University of Alberta Hospital (UAH) will be considered for study enrollment. Eligible patients who meet the inclusion and exclusion criteria and who provide informed consent will be randomized to undergo conventional colonoscopy or colonoscopy with the assistance of the ScopeGuide system. The control group will use Olympus CF-H180AL variable-stiffness, high-definition colonoscopes that do not differ from the usual procedure and the investigational group will use Olympus CF-H180DL variable-stiffness, high-definition colonoscopes equipped with ScopeGuide capabilities. ScopeGuide will provide the endoscopist with a 3-dimensional image on the monitor depicting the shape of the colonoscope inside the patient's body as it moves through the colon.

The colonoscopy will be performed as clinically indicated, either with or without the aid of the ScopeGuide system. All patients will undergo a purgative bowel preparation followed by an overnight fast prior to their colonoscopy according to standard clinical practice at UAH. At the start of the colonoscopy, all patients will initially be given standardized doses of conscious sedation medications consisting of midazolam 2 mg IV and fentanyl 25 mcg IV. However, the procedure may be initiated without any sedation upon patient request. Additional doses of sedative medications may be given at patient request or when the nurse or physician believes that the patient is uncomfortable. In all cases, the endoscopist will attempt to minimize the formation of loops within the colon and will straighten those loops whenever possible. This will be achieved by conventional methods that rely on "feel" and "instinct" in the control group and will be directed by the ScopeGuide visualization in the investigational group. The endoscopist may use any technical maneuvers deemed necessary to facilitate completion of the procedure, including the application of external abdominal pressure by the nurse, the repositioning of the patient, or tightening of the variable-stiffness setting of the colonoscope. Upon intubation of the cecum, the insertion distance of the colonoscope from the anus to the cecal pole will be recorded as a marker of the straightness of the endoscope. Any abnormalities detected during colonoscope insertion will be more closely inspected, photographed and biopsied during subsequent colonoscope withdrawal. Furthermore, polyps will also be preferentially removed during colonoscope withdrawal, which is the existing standard-of-care. Any diagnostic or therapeutic applications that are required during the colonoscopy are permitted as clinically indicated.

Relevant demographic and clinical information will be recorded prior to the procedure. Additional data regarding procedural metrics, technical maneuvers, and sedation doses will be recorded during the colonoscopy. At the conclusion of the colonoscopy, the endoscopist will rate the procedural difficulty as "usual" or "difficult" and will also note the procedural diagnosis.

After the procedure, the patient will be kept in the post-endoscopy recovery area in the usual fashion. Prior to discharge home from the recovery area, participants will complete a visual analogue scale reflecting their degree of discomfort experienced during the procedure.

Being tested
Olympus ScopeGuide
Keywords
Colonoscopy, Colon cancer screening
Medical subject headings
Colonic Neoplasms, Anemia, Iron-Deficiency, Diarrhea

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Olympus ScopeGuideDevice

    Also called Magnetic endoscopy imaging

    ScopeGuide-assisted colonoscopy using Olympus CF-H180DL variable-stiffness colonoscopes equipped with ScopeGuide capabilities. ScopeGuide will provide the endoscopist with a 3-dimensional image on the monitor depicting the shape of the colonoscope inside the patient's body as it moves through the colon.

Study groups in NCT01438645
Study groupRoleWhat they receive
ScopeGuide-assisted colonoscopyExperimentalThese patients will undergo colonoscopy with the assistance of the Olympus ScopeGuide system.
Receives: Device: Olympus ScopeGuide
Conventional colonoscopyNo interventionThese patients will undergo colonoscopy identical to that in the intervention arm, except with endoscopes lacking the ScopeGuide system.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Sedation Score

    The main efficacy parameter is the amount of sedation used during colonoscopy, expressed as the mean for each group. Since our conscious sedation consists of two different drugs, the doses of each will be converted into a numerical score, such that typical 1 mg dose increments of midazolam and 25 mcg increments of fentanyl will each be assigned a score of '1,' and the two will be added together to give the sedation score.

    Measured: 1 day (immediate outcome assessment at time of endoscopy procedure)

Secondary outcomes (4)
  1. Patient comfort

    Patients wil complete a 10 cm visual analogue pain scale (VAS) that will be converted to a numerical score (0-100) with each number representing 1 mm on the 10 cm VAS from 0 at its left extreme (representing 'no pain') to 100 on its right extreme (representing 'unbearably severe pain'). The mean pain score will then be determined for each of the groups.

    Measured: 1 day (immediate outcome assessment after recovery from endoscopy procedure)

  2. Time-to-cecum

    Time from initial insertion of colonoscope until successful intubation of the cecum (min)

    Measured: 1 day (immediate outcome assessment at time of endoscopy procedure)

  3. Cecal intubation rate

    Proportion of colonoscopy procedures resulting in successful intubation of the cecum.

    Measured: 1 day (immediate outcome assessment at time of endoscopy procedure)

  4. Ancillary maneuvers to facilitate procedure

    Number of added maneuvers, including abdominal pressure, repositioning of patient, endoscope loop reduction techniques, used to facilitate advancement of endoscope during procedure.

    Measured: 1 day (immediate outcome assessment at time of endoscopy procedure)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Sep 2011 (estimated)
  2. Study startSep 2011
  3. Primary completionOct 2012
  4. Study completionDec 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
250 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01438645
Sponsor's protocol ID
ScopeGuide 01
Status last verified
Jan 2013
First submitted
14 Sep 2011
Last updated
17 Jan 2013
Results posted
No
Data monitoring committee
No

Publications

  • Shah SG, Brooker JC, Williams CB, Thapar C, Saunders BP. Effect of magnetic endoscope imaging on colonoscopy performance: a randomised controlled trial. Lancet. 2000 Nov 18;356(9243):1718-22. doi: 10.1016/S0140-6736(00)03205-0.

    PubMed 11095259
  • Shah SG, Brooker JC, Thapar C, Suzuki N, Williams CB, Saunders BP. Effect of magnetic endoscope imaging on patient tolerance and sedation requirements during colonoscopy: a randomized controlled trial. Gastrointest Endosc. 2002 Jun;55(7):832-7. doi: 10.1067/mge.2002.124097.

    PubMed 12024136
  • Teshima CW, Zepeda-Gomez S, AlShankiti SH, Sandha GS. Magnetic imaging-assisted colonoscopy vs conventional colonoscopy: a randomized controlled trial. World J Gastroenterol. 2014 Sep 28;20(36):13178-84. doi: 10.3748/wjg.v20.i36.13178.

    PubMed 25278714

Questions about this trial

What is this clinical trial studying?

A study testing Olympus ScopeGuide in people with Colonic Neoplasms and Iron Deficiency Anemia, run by Christopher Teshima at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 17 Jan 2013. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Sedation Score (time frame: 1 day (immediate outcome assessment at time of endoscopy procedure)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01438645, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Jan 2013; AzTrials last refreshed its copy on 28 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in