Conjunctival Infections, Irritations and InflammationsNCT01441648
Influence of Cosmetic Color Tinted Contact Lenses on the Ocular Surface
An observational study of Conjunctival Infections, Irritations and Inflammations and Hypertrophy; Conjunctiva, run by Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation at 1 site in Taiwan.
Trial summary
More than 1 million people worldwide wear soft contact lenses for refractive error correction. However, severe sight threatening complications due to contact lens wear such as contact lens-related microbial keratitis (CLMK) are about 1 per 2500 persons per year. Read more about this study
- Who is it for?
- Ages 20 to 35 yearsHealthy volunteers can take part
- Conditions the study is for
- Conjunctival Infections, Irritations and Inflammations, Hypertrophy; Conjunctiva, Corneal Pannus
- What is being tested?
- contact lens wear
- How many people
- 14 participants
- Where
- 1 siteTaiwan
- Study dates
- Dec 2011to Dec 2013
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 20 to 35 years
- All sexes
- Healthy volunteers accepted
- Adult
Study population: 1) age 20-35 years old (2) myopia less than -6.00D and astigmatism less than -1.50D (3) previous soft contact lens wear discontinued for at least 2 weeks. Exclusion criteria includes: (1) subjects with previous Rigid Gas Permeable wear (2) any ocular inflammation or infection, dry eye syndrome, glaucoma, ocular trauma or surgery, and topical medication instillation (3) diabetic mellitus (4) pregnancy (5) any corneal disorders or dystrophies.
Who may be able to join
- Age 20-35 years old
- myopia less than -6.00 D, Astigmatism less than 1.50 D
- previous soft contact lens wear discontinued for at least 2 weeks
Who cannot join
- subjects with previous Rigid Gas Permeable wear
- Any ocular surgery or topical medication
- dry eye syndrome
- glaucoma
- ocular trauma
- pregnancy
- any corneal disorders or dystrophies
Trial locations and contacts
1 site in 1 country.
About this study
More than 1 million people worldwide wear soft contact lenses for refractive error correction. However, severe sight threatening complications due to contact lens wear such as contact lens-related microbial keratitis (CLMK) are about 1 per 2500 persons per year. The rate of infection increases drastically to 1 per 500 person per year if lenses were worn overnight. Recently, color tinted cosmetic soft contact lenses, which are essentially soft contact lenses with a color tinted annular ring, are gaining increasing popularity especially among the younger and Asian population desiring a change in iris color or the doll-eyed look. However, studies on the effect of these lenses on the ocular surface have been scarce. Recently, a report of 12 cases of lens-related microbial keratitis due to wear of the color tinted lenses have been reported. Others reported of decreased contrast sensitivity, increased higher order aberrations, and temporary changes in corneal topography due to color tinted lens wear. Nevertheless, comprehensive and prospective study has not yet been done. Thus, the purpose of this study is to conduct a prospective observational study to determine the influence of color tinted cosmetic contact lens wear both on visual performance and ocular surface alterations.
Read the detailed description
- Methods All subjects are required to fill out basic information and take a survey questionnaire before and after contact lens wear. Subjects will be examined and tested before being fitted to color tinted contact lens with slit-lamp biomicroscopy and fluorescein staining (Heig Strait, Germany), intraocular pressure measurement by pneumotonometery (Topcon® CT-80), refractometer (Topcon® KR-8900), uncorrected and best corrected Snellen visual acuity (UCVA and BCVA), Schirmir test 1, tear film break-up time (TBUT), corneal topography (Bausch \& Lomb® Orb IIz), and endothelial cell density measurement by specular microscopy (Konan Noncon Robo-Sp-9000, USA). Exams are also performed at 1 week, 1, 3, and 6 months of lens wear. A special chart for all subjects is filled out during each visit During each exam, subjects will be observed for signs of conjunctival injection, conjunctival papillary hypertrophy, pannus formation, and corneal epitheliopathy. These signs are graded as shown in the table below.
Signs 0=Normal 1=Mild 2=Moderate 3=Severe Conjunctival Injection None Minimal Obvious Diffuse Papillae Size None <0.25mm 0.25-0.5mm >0.5mm Superficial Pannus No pannus 1 quadrant 2 quadrants >=3 quadrants Punctate Epitheliopathy None <1/3 of cornea 1/3-1/2 of cornea Confluent or with epithelial defect
Schirmir test 1 (basal secretion test) is performed for 5 minutes and considered abnormal if the filter strip wets <5 mm in length. TBUT of less than 10 seconds is considered abnormal.
Impression cytology will be performed before lens wear and at 3 and 6 months post lens wear at National Taiwan University. Nitrocellulose filter paper with the pore size of 0.22 μm (Millipore GSWP 04700, Billerica, MA, U.S.A.) are cut into strips (about 4x8 mm). After a drop of topical anesthetic (proparacaine 0.5 %) application, excess tears are gently absorbed by sterile cotton swabs. Nitrocellulose strip are placed on the surface of limbal conjunctiva. After applying light pressure, the paper strips are peeled off and immediately fixed in 95% alcohol. The strips are then stained using periodic acid-Schiff (PAS ; Sigma 395132, Hattiesburg, MS, USA) and examined under light microscopy at 40X magnification and graded by mask observers following Saini et al's criteria21 as follows. Grade 1: Small round epithelial cells with a nucleus to cytoplasm ration of 1:2. Large number of deeply positive cells present. A good confluent sheet of cells is usually obtained. Grade2: A good cell sheet consisting of larger polygonal epithelial cells with a decreased nucleocytoplasmic ration of 1:3. Goblet cells reduced in number, but still deeply PAS-positive. Grade 3: Larger polygonal cells with a further decrease in nucleus to cytoplasm ratio. Reduced number of goblet cells, with reduced staining. Grade 4: Larger polygonal basophilic cells with pyknotic nuclei. Intracellular keratin often demonstrable. Absent goblet cells. Only a few loose clumps were obtainable. Goblet cell density is also graded by counting the average number of cells per 100 epithelial cells in at least four high power fields (HPF). Grade 1: >30 goblet cells/ 4 HPF. Grade 2: 15-30 goblet cells/ 4 HPF. Grade 3: 5-15 goblet cells/ 4 HPF. Grade 4: <5 goblet cells/ 4 HPF.
In vivo confocal microscopy imaging of the cornea will be performed before lens wear and at 3 and 6 months post lens wear by one masked examiner on all subjects at National Taiwan University. One drop of 0.5% proparacaine solution and artificial tears was instilled immediately before each exam. After asking the patients to look straight ahead, an in vivo confocal microscope (Confoscan 3.4.1; Nidek Technologies, Padova, Italy) equipped with a standard 40x water-immersion front lens captured images of the full thickness of the central cornea automatically. Each examination took approximately 1 to 3 minutes and recorded 350 images at a distance of 1.5 and 4 μm on the z-axis between successive images. During each visit, measurements were repeated with 4 um z-interval for 3 times followed by 1.5 um z-interval for 3 times. Analysis of epithelial cells morphology, epithelial thickness, and stromal reaction follows that has been published by Chen et al22-24. Corneal nerve morphology and density will also be recorded and analyzed.
Used contact lenses will be place in the provided storage cases and brought back to check for completeness of lens with no tear or chipped pieces. The lenses are then used for further material analysis by scanning electromicroscopy (SEM) and bacterial adhesion determination with personal funding. For SEM, used lenses were fixed in half strength Karnovskys fixative ( 2% paraformaldehyde and 2.5% glutaraldehyde) after gentle washing. The fixative was removed and distilled water was added for rinsing. Rapid freezing with liquid nitrogen immersion was done before being placed under vacuum overnight. The concave side of samples was mounted on aluminum stubs and sputter-coated with gold for examination under SEM (JEOL Ltd, JSM 5300, Japan) at 15kV under various magnification. For bacterial adhesion determination, used lenses are collected in sterile plates and gently dipped three times in PBS before placement in eppendorf tubes containing 1ml PBS. The lenses are then macerated and serial dilutions up to 105 are done before plating onto Muller-Hinton agar. The agar plates are incubated overnight and colony forming units are counted the next day. Number of colonies multiplied by dilution factor divided by the volume plated will give the CFU/ml/per contact lens.
All data will be entered into Excel spreadsheet (Microsoft, Inc) and analyzed using SPSS software for Windows (11.0, SPSS, Inc.). Paired t-tests will be used to compare all parameters before and after wear of the color tinted contact lenses.
- Conditions
- Conjunctival Infections, Irritations and Inflammations, Hypertrophy; Conjunctiva, Corneal Pannus, Corneal Epithelial Wound
- Being tested
- contact lens wear
- Keywords
- conjunctival injection, conjunctival papillary hypertrophy, pannus formation, corneal epitheliopathy, Schirmer test, Impression cytology, confocal microscopy, Scanning electronmicroscopy (SEM), bacterial adhesion determination
- Medical subject headings
- Inflammation, Hypertrophy
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
contact lens wearOther
Also called cosmetic colored contact lenses, Ciba Vision Freshlook
tinted contact lens wear
| Study group | Role | What they receive |
|---|---|---|
| experimental group | (1) age 20-35 years old (2) myopia less than -6.00D and astigmatism less than -1.50D (3) previous soft contact lens wear discontinued for at least 2 weeks. Exclusion criteria includes: (1) subjects with previous Rigid Gas Permeable (RGP) wear (2) any ocular inflammation or infection, dry eye syndrome, glaucoma, ocular trauma or surgery, and topical medication instillation (3) diabetic mellitus (4) pregnancy (5) any corneal disorders or dystrophies. Receives: Other: contact lens wear |
What is being measured
The primary outcome is the main question the study is designed to answer.
Comfort
Measured: during 6 month weart
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted28 Sep 2011 (estimated)
- Study startDec 2011
- Primary completionDec 2013
- Study completionDec 2013
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Conjunctival Infections, Irritations and InflammationsStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 14 participants (actual)
Sponsor and investigators
- Lead sponsor
- Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation
- Sponsor type
- University, hospital or other
- Collaborators
- National Taiwan University Hospital
- Responsible party
- Sponsor
- Investigators
- Elizabeth P Shen, Principal investigator, Buddhist Tzu Chi General Hospital, Taipei Branch
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01441648
- Sponsor's protocol ID
- 00-IRB-007-XD
- Other IDs
- Shen EP
- Status last verified
- Dec 2011
- First submitted
- 26 Sep 2011
- Last updated
- 20 Jan 2014
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 20 Jan 2014. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Influence of Cosmetic Color Tinted Contact Lenses on the Ocular Surface
- ClinicalTrials.gov ID
- NCT01441648
- Acronym / sponsor ID
- 00-IRB-007-XD
- Conditions
- Conjunctival Infections, Irritations and Inflammations, Hypertrophy; Conjunctiva, Corneal Pannus, Corneal Epithelial Wound
- Keywords
- conjunctival injection, conjunctival papillary hypertrophy, pannus formation, corneal epitheliopathy, Schirmer test, Impression cytology, confocal microscopy, Scanning electronmicroscopy (SEM)
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 14 participants (actual)
- Lead sponsor
- Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical FoundationUniversity, hospital or other
- Collaborators
- National Taiwan University Hospital
- Study start
- Dec 2011
- Primary completion
- Dec 2013 (actual)
- Study completion
- Dec 2013 (actual)
- First posted
- 28 Sep 2011 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
More than 1 million people worldwide wear soft contact lenses for refractive error correction. However, severe sight threatening complications due to contact lens wear such as contact lens-related microbial keratitis (CLMK) are about 1 per 2500 persons per year. The rate of infection increases drastically to 1 per 500 person per year if lenses were worn overnight. Recently, color tinted cosmetic soft contact lenses, which are essentially soft contact lenses with a color tinted annular ring, are gaining increasing popularity especially among the younger and Asian population desiring a change in iris color or the doll-eyed look. However, studies on the effect of these lenses on the ocular surface have been scarce. Recently, a report of 12 cases of lens-related microbial keratitis due to wear of the color tinted lenses have been reported. Others reported of decreased contrast sensitivity, increased higher order aberrations, and temporary changes in corneal topography due to color tinted lens wear. Nevertheless, comprehensive and prospective study has not yet been done. Thus, the purpose of this study is to conduct a prospective observational study to determine the influence of color tinted cosmetic contact lens wear both on visual performance and ocular surface alterations.
Detailed description
- Methods All subjects are required to fill out basic information and take a survey questionnaire before and after contact lens wear. Subjects will be examined and tested before being fitted to color tinted contact lens with slit-lamp biomicroscopy and fluorescein staining (Heig Strait, Germany), intraocular pressure measurement by pneumotonometery (Topcon® CT-80), refractometer (Topcon® KR-8900), uncorrected and best corrected Snellen visual acuity (UCVA and BCVA), Schirmir test 1, tear film break-up time (TBUT), corneal topography (Bausch \& Lomb® Orb IIz), and endothelial cell density measurement by specular microscopy (Konan Noncon Robo-Sp-9000, USA). Exams are also performed at 1 week, 1, 3, and 6 months of lens wear. A special chart for all subjects is filled out during each visit During each exam, subjects will be observed for signs of conjunctival injection, conjunctival papillary hypertrophy, pannus formation, and corneal epitheliopathy. These signs are graded as shown in the table below.
Signs 0=Normal 1=Mild 2=Moderate 3=Severe Conjunctival Injection None Minimal Obvious Diffuse Papillae Size None <0.25mm 0.25-0.5mm >0.5mm Superficial Pannus No pannus 1 quadrant 2 quadrants >=3 quadrants Punctate Epitheliopathy None <1/3 of cornea 1/3-1/2 of cornea Confluent or with epithelial defect
Schirmir test 1 (basal secretion test) is performed for 5 minutes and considered abnormal if the filter strip wets <5 mm in length. TBUT of less than 10 seconds is considered abnormal.
Impression cytology will be performed before lens wear and at 3 and 6 months post lens wear at National Taiwan University. Nitrocellulose filter paper with the pore size of 0.22 μm (Millipore GSWP 04700, Billerica, MA, U.S.A.) are cut into strips (about 4x8 mm). After a drop of topical anesthetic (proparacaine 0.5 %) application, excess tears are gently absorbed by sterile cotton swabs. Nitrocellulose strip are placed on the surface of limbal conjunctiva. After applying light pressure, the paper strips are peeled off and immediately fixed in 95% alcohol. The strips are then stained using periodic acid-Schiff (PAS ; Sigma 395132, Hattiesburg, MS, USA) and examined under light microscopy at 40X magnification and graded by mask observers following Saini et al's criteria21 as follows. Grade 1: Small round epithelial cells with a nucleus to cytoplasm ration of 1:2. Large number of deeply positive cells present. A good confluent sheet of cells is usually obtained. Grade2: A good cell sheet consisting of larger polygonal epithelial cells with a decreased nucleocytoplasmic ration of 1:3. Goblet cells reduced in number, but still deeply PAS-positive. Grade 3: Larger polygonal cells with a further decrease in nucleus to cytoplasm ratio. Reduced number of goblet cells, with reduced staining. Grade 4: Larger polygonal basophilic cells with pyknotic nuclei. Intracellular keratin often demonstrable. Absent goblet cells. Only a few loose clumps were obtainable. Goblet cell density is also graded by counting the average number of cells per 100 epithelial cells in at least four high power fields (HPF). Grade 1: >30 goblet cells/ 4 HPF. Grade 2: 15-30 goblet cells/ 4 HPF. Grade 3: 5-15 goblet cells/ 4 HPF. Grade 4: <5 goblet cells/ 4 HPF.
In vivo confocal microscopy imaging of the cornea will be performed before lens wear and at 3 and 6 months post lens wear by one masked examiner on all subjects at National Taiwan University. One drop of 0.5% proparacaine solution and artificial tears was instilled immediately before each exam. After asking the patients to look straight ahead, an in vivo confocal microscope (Confoscan 3.4.1; Nidek Technologies, Padova, Italy) equipped with a standard 40x water-immersion front lens captured images of the full thickness of the central cornea automatically. Each examination took approximately 1 to 3 minutes and recorded 350 images at a distance of 1.5 and 4 μm on the z-axis between successive images. During each visit, measurements were repeated with 4 um z-interval for 3 times followed by 1.5 um z-interval for 3 times. Analysis of epithelial cells morphology, epithelial thickness, and stromal reaction follows that has been published by Chen et al22-24. Corneal nerve morphology and density will also be recorded and analyzed.
Used contact lenses will be place in the provided storage cases and brought back to check for completeness of lens with no tear or chipped pieces. The lenses are then used for further material analysis by scanning electromicroscopy (SEM) and bacterial adhesion determination with personal funding. For SEM, used lenses were fixed in half strength Karnovskys fixative ( 2% paraformaldehyde and 2.5% glutaraldehyde) after gentle washing. The fixative was removed and distilled water was added for rinsing. Rapid freezing with liquid nitrogen immersion was done before being placed under vacuum overnight. The concave side of samples was mounted on aluminum stubs and sputter-coated with gold for examination under SEM (JEOL Ltd, JSM 5300, Japan) at 15kV under various magnification. For bacterial adhesion determination, used lenses are collected in sterile plates and gently dipped three times in PBS before placement in eppendorf tubes containing 1ml PBS. The lenses are then macerated and serial dilutions up to 105 are done before plating onto Muller-Hinton agar. The agar plates are incubated overnight and colony forming units are counted the next day. Number of colonies multiplied by dilution factor divided by the volume plated will give the CFU/ml/per contact lens.
All data will be entered into Excel spreadsheet (Microsoft, Inc) and analyzed using SPSS software for Windows (11.0, SPSS, Inc.). Paired t-tests will be used to compare all parameters before and after wear of the color tinted contact lenses.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| experimental group | – | Other: contact lens wear(1) age 20-35 years old (2) myopia less than -6.00D and astigmatism less than -1.50D (3) previous soft contact lens wear discontinued for at least 2 weeks. Exclusion criteria includes: (1) subjects with previous Rigid Gas Permeable (RGP) wear (2) any ocular inflammation or infection, dry eye syndrome, glaucoma, ocular trauma or surgery, and topical medication instillation (3) diabetic mellitus (4) pregnancy (5) any corneal disorders or dystrophies. |
Who may qualify
- Ages
- 20 to 35 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult
- Study population
- 1) age 20-35 years old (2) myopia less than -6.00D and astigmatism less than -1.50D (3) previous soft contact lens wear discontinued for at least 2 weeks. Exclusion criteria includes: (1) subjects with previous Rigid Gas Permeable wear (2) any ocular inflammation or infection, dry eye syndrome, glaucoma, ocular trauma or surgery, and topical medication instillation (3) diabetic mellitus (4) pregnancy (5) any corneal disorders or dystrophies.
Key inclusion criteria (3 listed)
- Age 20-35 years old
- myopia less than -6.00 D, Astigmatism less than 1.50 D
- previous soft contact lens wear discontinued for at least 2 weeks
Key exclusion criteria (7 listed)
- subjects with previous Rigid Gas Permeable wear
- Any ocular surgery or topical medication
- dry eye syndrome
- glaucoma
- ocular trauma
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| contact lens wearAlso: cosmetic colored contact lenses, Ciba Vision Freshlooktinted contact lens wear | Other | experimental group |
Primary outcome
Comfort
Time frame: during 6 month weart
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 20 Jan 2014.
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Elizabeth P Shen principal investigator
Buddhist Tzu Chi General Hospital, Taipei Branch
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Conjunctival Infections, Irritations and Inflammations and Hypertrophy; Conjunctiva, run by Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation at 1 site in Taiwan.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 20 Jan 2014. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Taiwan. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Comfort (time frame: during 6 month weart). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Jan 2014.