Heart DiseasesNCT01484249
Carotid Filtration During Endovascular Aortic Valve Implantation
A study testing CE Pro System in people with Heart Diseases, run by Claret Medical.
Trial summary
This study was designed as a First In Man (FIM) trial to evaluate the feasibility and technical capability of the Claret CE Pro System in delivering two embolic filters to the brachiocephalic artery and the left common carotid artery during a Transcatheter aortic valve implantation (TAVI) procedure in order to protect… Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Heart Diseases
- What is being tested?
- CE Pro System
- Type of treatment
- Medical device
- How many people
- 38 participants
- Where
- No sites listed yet
- Study dates
- Feb 2010to May 2011
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Subject must be scheduled to undergo an endovascular aortic valve prosthesis implant procedure with the femoral artery as the intended access site for the valve delivery system.
- Female subjects of child bearing potential must have a negative pregnancy test within 48 hours prior to the study procedure.
- Subject's left carotid artery and innominate artery diameters must be compatible with the Claret CE Pro System sizes available for the procedure (refer to package labeling for appropriate sizing information).
- Subject must have been informed of the nature of the study, agree to its provisions, and provide written informed consent.
Who cannot join
- Subject requires an emergent procedure.
- Subject has carotid artery stenosis >70% in either carotid artery.
- Subject innominate or left carotid artery reveals significant stenosis, ectasia, dissection or aneurysm at the ostium or within 3 cm of the ostium.
- Subject has allergy to materials from which the device is constructed (Nitinol, fluorinated ethylene-propylene, polyamide, polyimide, platinum, iridium, stainless steel, cyanoacrylate adhesives, polycarbonate, polyethylene, polyester, polyurethane, PTFE [poly-tetrafluoroethylene], polydimethylsiloxane [lubricant coating], silicone, polyetheretherketone, tin-silver [solder] or acrylated urethane adhesives)
- Subject has a history of bleeding diatheses or coagulopathy or will refuse blood transfusion in cases of emergency.
- Subject has renal insufficiency, defined as a creatinine level > 2.5 mg/dl at the time of treatment, unless subject is on chronic hemodialysis.
Show all 11Show fewer
- Subject has hyperthyroidism.
- Subject suffered recent (within the past 3 months) stroke with permanent deficit.
- Subject suffered recent (within the past 6 months) significant gastrointestinal (GI) bleed.
- Subject is involved in another clinical study or has other medical illnesses that may cause the subject to be non-compliant with the protocol or confound the data interpretation.
- Subject history of intolerance, allergic reaction or contraindication to any of the study medications, including heparin, aspirin, Clopidogrel, or a sensitivity to contrast media or anesthesia which cannot be adequately pre-treated.
About this study
This study was designed as a First In Man (FIM) trial to evaluate the feasibility and technical capability of the Claret CE Pro System in delivering two embolic filters to the brachiocephalic artery and the left common carotid artery during a Transcatheter aortic valve implantation (TAVI) procedure in order to protect the neurovasculature from debris liberated during the procedure.
Read the detailed description
Transcatheter aortic valve implantation (TAVI) is a recently developed procedure whereby a prosthetic aortic valve is implanted percutaneously, and the procedure has demonstrated promising results in high risk surgical populations.
TAVI currently requires the use of large bore (18-26F) catheter delivery systems that are often difficult to deliver to over the aortic arch to the aortic annulus. Available data indicate that TAVI is associated with a 4-12% procedural stroke rate and approximately 10% procedural mortality. It has been suggested that these strokes are most likely caused by the liberation of embolic debris either when the TAVI delivery catheter is advanced over the aortic arch or during the actual valve deployment. Given this situation, the availability of devices able to protect both hemispheres of the brain from potentially embolic debris during the TAVI procedure is an emerging clinical need.
Claret Medical has developed a technology to provide protection to the neurovascular system during TAVI and other valve repair procedures.
- Conditions
- Heart Diseases
- Being tested
- CE Pro System
- Keywords
- embolic, filters, brachiocephalic, neurovasculature, debris
- Medical subject headings
- Heart Diseases
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
CE Pro SystemDevice
Also called Gen 2.0, Gen 2.1, Gen 2.2
The CE Pro System consists of a delivery catheter with an integrated proximal filter intended to be deployed in the brachiocephalic artery. In addition, the device has an articulating distal tip and a through lumen to allow a commercial intravascular filter to be back-loaded into the CE Pro System and be deployed into and retrieved from the left carotid artery.
What is being measured
The primary outcome is the main question the study is designed to answer.
Primary endpoint is technical success of the CE Pro System to deliver, retrieve proximal & distal filters during an endovascular procedure such as Transcatheter aortic valve implantation (TAVI).
Technical success defined as, successful delivery \& retrieval of the proximal \& distal filters.
The following Operator feedback was collected \& used to evaluate the primary endpoint.
Operators are asked to record, the indwelling time for the CE Pro System was used. Calculated as duration from the CE Pro System Insertion Start Time to Final Retrieval Stop Time.
Operators are asked to rate the CE Pro Systems performance based on a scale of 1 to 5, with 5 being the highest rating.
Measured: From the CE Pro System Insertion Start Time to Final Retrieval Stop Time
Secondary outcomes (1)
Transient Ischemia Attack (TIA) Rates
The secondary endpoints for this trial are safety endpoints and are presented as adverse events.
Measured: 30 day follow up
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted2 Dec 2011 (estimated)
- Study startFeb 2010
- Primary completionMay 2011
- Study completionMay 2011
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Heart DiseasesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Supportive care
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 38 participants (actual)
Sponsor and investigators
- Lead sponsor
- Claret Medical
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- Meditrial Europe Ltd.
- Responsible party
- Sponsor
- Investigators
- Eberhard Grube, MD, Ph D, Principal investigator, Professor of Medicine, Medizinishce Klinik und Poliklinik II, Universitätsklinikum Bonn
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01484249
- Sponsor's protocol ID
- CMP 001b
- Status last verified
- Dec 2011
- First submitted
- 24 Nov 2011
- Last updated
- 5 Dec 2011
- Results posted
- No
- Data monitoring committee
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 5 Dec 2011. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Carotid Filtration During Endovascular Aortic Valve Implantation
- ClinicalTrials.gov ID
- NCT01484249
- Acronym / sponsor ID
- CMP 001b
- Conditions
- Heart Diseases
- Keywords
- embolic, filters, brachiocephalic, neurovasculature, debris
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 38 participants (actual)
- Lead sponsor
- Claret MedicalIndustry (pharma, biotech, devices)
- Collaborators
- Meditrial Europe Ltd.
- Study start
- Feb 2010
- Primary completion
- May 2011 (actual)
- Study completion
- May 2011 (actual)
- First posted
- 2 Dec 2011 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study was designed as a First In Man (FIM) trial to evaluate the feasibility and technical capability of the Claret CE Pro System in delivering two embolic filters to the brachiocephalic artery and the left common carotid artery during a Transcatheter aortic valve implantation (TAVI) procedure in order to protect the neurovasculature from debris liberated during the procedure.
Detailed description
Transcatheter aortic valve implantation (TAVI) is a recently developed procedure whereby a prosthetic aortic valve is implanted percutaneously, and the procedure has demonstrated promising results in high risk surgical populations.
TAVI currently requires the use of large bore (18-26F) catheter delivery systems that are often difficult to deliver to over the aortic arch to the aortic annulus. Available data indicate that TAVI is associated with a 4-12% procedural stroke rate and approximately 10% procedural mortality. It has been suggested that these strokes are most likely caused by the liberation of embolic debris either when the TAVI delivery catheter is advanced over the aortic arch or during the actual valve deployment. Given this situation, the availability of devices able to protect both hemispheres of the brain from potentially embolic debris during the TAVI procedure is an emerging clinical need.
Claret Medical has developed a technology to provide protection to the neurovascular system during TAVI and other valve repair procedures.
Study design
- Primary purpose
- Supportive care
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Subject must be scheduled to undergo an endovascular aortic valve prosthesis implant procedure with the femoral artery as the intended access site for the valve delivery system.
- Female subjects of child bearing potential must have a negative pregnancy test within 48 hours prior to the study procedure.
- Subject's left carotid artery and innominate artery diameters must be compatible with the Claret CE Pro System sizes available for the procedure (refer to package labeling for appropriate sizing information).
- Subject must have been informed of the nature of the study, agree to its provisions, and provide written informed consent.
Key exclusion criteria (11 listed)
- Subject requires an emergent procedure.
- Subject has carotid artery stenosis >70% in either carotid artery.
- Subject innominate or left carotid artery reveals significant stenosis, ectasia, dissection or aneurysm at the ostium or within 3 cm of the ostium.
- Subject has allergy to materials from which the device is constructed (Nitinol, fluorinated ethylene-propylene, polyamide, polyimide, platinum, iridium, stainless steel, cyanoacrylate adhesives, polycarbonate, polyethylene, polyester, polyurethane, PTFE [poly-tetrafluoroethylene], polydimethylsiloxane [lubricant coating], silicone, polyetheretherketone, tin-silver [solder] or acrylated urethane adhesives)
- Subject has a history of bleeding diatheses or coagulopathy or will refuse blood transfusion in cases of emergency.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| CE Pro SystemAlso: Gen 2.0, Gen 2.1, Gen 2.2The CE Pro System consists of a delivery catheter with an integrated proximal filter intended to be deployed in the brachiocephalic artery. In addition, the device has an articulating distal tip and a through lumen to allow a commercial intravascular filter to be back-loaded into the CE Pro System and be deployed into and retrieved from the left carotid artery. | Device | – |
Primary outcome
Primary endpoint is technical success of the CE Pro System to deliver, retrieve proximal & distal filters during an endovascular procedure such as Transcatheter aortic valve implantation (TAVI).
Time frame: From the CE Pro System Insertion Start Time to Final Retrieval Stop Time
Technical success defined as, successful delivery \& retrieval of the proximal \& distal filters. The following Operator feedback was collected \& used to evaluate the primary endpoint. Operators are asked to record, the indwelling time for the CE Pro System was used. Calculated as duration from the CE Pro System Insertion Start Time to Final Retrieval Stop Time. Operators are asked to rate the CE Pro Systems performance based on a scale of 1 to 5, with 5 being the highest rating.
1 secondary outcome
Transient Ischemia Attack (TIA) Rates
Time frame: 30 day follow up
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 5 Dec 2011.
Related trials for Heart Diseases
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
RecruitingObservational study
AI-powered ECG Analysis Using Willem™ Software in High-risk Cardiac Patients (WILLEM)
Cardiomyopathies, Cardiac Arrest
RecruitingPhase 4
The Effects of Ferric Derisomaltose in Patients With Acute Heart Failure and Iron Deficiency on Exercise Capacity and Quality of Life(COREVIVE-HFrEF)
Heart Failure With Reduced Ejection Fraction, Iron Deficiency
Recruiting
Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR
Aortic Stenosis Treated With TAVI, Aortic Diseases
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Eberhard Grube, MD, Ph D principal investigator
Professor of Medicine, Medizinishce Klinik und Poliklinik II, Universitätsklinikum Bonn
Questions about this trial
What is this clinical trial studying?
A study testing CE Pro System in people with Heart Diseases, run by Claret Medical.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 5 Dec 2011. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Primary endpoint is technical success of the CE Pro System to deliver, retrieve proximal & distal filters during an endovascular procedure such as Transcatheter aortic valve implantation (TAVI). (time frame: From the CE Pro System Insertion Start Time to Final Retrieval Stop Time). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Dec 2011.