AzTrials
AzTrials

Arteriovenous FistulaNCT01512927

Electro Stethoscope in Detect Arteriovenous Fistula (AVF) Stenosis

An observational study of Arteriovenous Fistula, run by National Taiwan University Hospital at 1 site in Taiwan.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The incidence and prevalence of end-stage renal disease (ESRD) in Taiwan are both the highest worldwide from 2001 to 2008. In Taiwan, more than 90% of the ESRD patients are hemodialysis patients. Read more about this study

Who is it for?
Ages 20 to 90 years
Conditions the study is for
Arteriovenous Fistula
How many people
150 participants
Where
1 siteTaiwan
Study dates
Jan 2012to Dec 2012
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: 150

Who may be able to join

  • Age is more than 20 year-old.
  • End-stage renal disease with regular hemodialysis for more than one year

Who cannot join

  • 1. AVF/ AV graft is not located in upper arm.

Trial locations and contacts

1 site in 1 country.

DONG-FENG YEIH, Ph.D. contact

886-2-23123456 ext. 63738

Taiwan1 site, 1 recruiting
  • National Taiwan University Hospital

    Taipei, Taiwan, 100

    DONG-FENG YEIH, OPh.D., 886-2-23123456 ext. 63738, 601126@ntuh.gov.tw

    DONG-FENG YEIH, Ph.D.

    Recruiting

Other trials in Taiwan

About this study

Official title: Electronic Stethoscope and Computer-aided Diagnostic System in Detecting Arteriovenous Fistula (AVF) Stenosis

The incidence and prevalence of end-stage renal disease (ESRD) in Taiwan are both the highest worldwide from 2001 to 2008. In Taiwan, more than 90% of the ESRD patients are hemodialysis patients. Either arteriovenous fistula (AVF) or arteriovenous graft (AV graft) is essential for the vascular access of these patients. However, frequent AVF stenosis or thrombosis occurs in 10-30% hemodialytic patients, and the rates are even higher, around 30-70%, in those who has a past history of AVF/AV graft stenosis. Therefore, early detection of AVF stenosis is essential in caring for these hemodialysis patients in terms of medical economics and psychological impact. Unfortunately, angiographic study is expensive and invasive and needs contrast medium injection. The diagnostic accuracy of color duplex ultrasound in AVF stenosis remains satisfactory, but it is not always available when decreased AVF flow or an acute thrombotic event occurs. Continuous AVF/ AV graft flow monitoring by patient himself is a better option in terms of long-term care. Previous study indicated that stethoscope waveform analysis could be used as an alternative to diagnosis of vascular stenosis. Therefore, we aim to investigate AVF/ AV graft stenosis by using the electronic stethoscope (3M Littmann) for AVF sound recording, followed by software analysis by using waveform decomposition, principle component analysis (PCA) and sequential forward selection algorithm [xx]. Our study results will provide a new diagnostic option, which is low cost, non-invasive and self-monitoring, of AVF stenosis in ESRD patients.

Read the detailed description

Hemodialysis is a well-established method for removal of fluid and uremic toxins and prolonging survival in patients with end-stage renal disease (ESRD). The most common permanent vascular assesses are autogenous and non-autogenous arteriovenous (AV) fistula, referred as AV fistula and AV graft, respectively. In Taiwan, both incidence and prevalence of ESRD remain highest worldwide. However, frequent vascular stenosis/ thrombosis events occurred because of repeated needle punctures. These will exert a large economic burden to our society and psychological impacts on ESRD patients [1]. Therefore, it is essential to develop an easy and patient-centered method to monitor the flow status in either AV fistula or AV graft.

Physical examination and auscultation are simple monitoring methods to assess the vascular access. There were several signs reported to be associated vascular stenosis, such as prolonged bleeding, arm edema, and changes in pulse characteristics of the vascular access, but they need a high level of skill and experience from the operator, such as doctors and nurses [2].

Unfortunately, angiographic study is expensive and invasive and needs contrast medium injection. The diagnostic accuracy of color duplex ultrasound in AVF stenosis remains satisfactory, but it is not always available when decreased AVF flow or an acute thrombotic event occurs. Continuous AVF/ AV graft flow monitoring by patient himself is a better option in terms of long-term care. Previous study indicated that stethoscope waveform analysis could be used as an alternative to diagnosis of vascular stenosis. Previous acoustic studies indicated that increased sound intensity, extra sounds, and higher spectral energy infrequency domain, ranging between 300 Hz and 1000 Hz. These findings are associated with the change from laminar flow to turbulent flow downstream the site of vascular stenosis [3]. In addition, phonoangiography studies pointed out that the systolic peak of stenotic segment is higher and narrower in the time domain compared to non-stenotic segment Methods: This is an observational cohort study. We plan to recruit 150 eligible patients with ESRD under regular hemodialysis for at least one year in national Taiwan University Hospital.

  1. Data gathering A. The first group of patients (study group) will be recruited from hose referred to endovascular intervention, e.g. angioplasty, due to vascular access dysfunction (n=30). An electronic stethoscope (3M-Littmann) will be used to record digital sound signals at 5 points with 30 seconds each, including AV junction, proximal and distal to both needle puncture sites, respectively. All data will be transferred to a computer for further anlaysis.
  2. The second group (validation cohort) will be recruited from patients with regular hemodialysis (HD) and received angioplasty at National Taiwan University Hospital (n=120). Those patients who received angioplasty for AVF or AV graft stenosis will also received follow-up angiography 12 weeks after angioplasty. We will record digital AVF/AV graft sound signals as mentioned above. In addition, blood pressure and AVF/AVG venous pressure, heart rate will be recorded. Diameter stenosis of restenotic segment will also be recorded and a diameter stenosis of 50% is regarded as significant.
  3. Post-processing The proposed method is based on the analysis of the envelope of the sound signals. Before, calculating the envelope, all signals will be down-sampled to 2k Hz, followed by a linear-phase, finite impulse response low-pass filter. PCA will then be applied to analysis as described previously [1-4]. PCA (principal components analysis)
  4. Analysis Sensitivity, specificity and diagnostic accuracy will be calculated based on each diagnostic criteria or basal function. Area under ROC curve will be calculated based on each diagnostic criteria derived from PCA method.
Keywords
electronic stethoscope, arteriovenous fistula, hemodialysis,
Medical subject headings
Arteriovenous Fistula

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

Study groups in NCT01512927
Study groupRoleWhat they receive
ESRD with regular hemodialysisNot described

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Jan 2012 (estimated)
  2. Study startJan 2012
  3. Primary completionNov 2012 (estimated)
  4. Study completionDec 2012 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
150 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01512927
Sponsor's protocol ID
201112015RIC
Status last verified
Jan 2012
First submitted
15 Jan 2012
Last updated
19 Jan 2012
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

An observational study of Arteriovenous Fistula, run by National Taiwan University Hospital at 1 site in Taiwan.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 19 Jan 2012. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Taiwan. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact DONG-FENG YEIH, Ph.D. (886-2-23123456 ext. 63738), or a site near the patient. AzTrials does not enrol participants or take referrals.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Jan 2012.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in