Type 1 Diabetes MellitusNCT01534013
Clinical Assessment of a Closed-loop Insulin Delivery System
A study testing The Imperial College Closed-Loop Insulin Delivery System and Open loop in people with Type 1 Diabetes Mellitus, run by Imperial College London at 1 site in United Kingdom.
Trial summary
The purpose of the study is to assess the safety and efficacy of the Imperial College closed loop insulin delivery system (artificial pancreas) in subjects with type 1 diabetes. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Type 1 Diabetes Mellitus
- What is being tested?
- The Imperial College Closed-Loop Insulin Delivery System and Open loop
- Type of treatment
- Injection or infusion, Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 23 participants
- Where
- 1 siteUnited Kingdom
- Study dates
- Aug 2011to Aug 2018
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Adults over 18 years of age
- Type 1 diabetes confirmed on the basis of clinical features and a fasting c-peptide <200nmol/L
- Type 1 diabetes for greater than 1 year
- Continuous subcutaneous insulin infusion for greater than 6 months
- HbA1c < 8.5% (69mmol/mol)
Who cannot join
- Recurrent severe hypoglycaemia
- Pregnant or planning pregnancy
- Breastfeeding
- Enrolled in other clinical trials
- Have active malignancy or under investigation for malignancy
Trial locations and contacts
1 site in 1 country.
United Kingdom1 site
Imperial College London, St Mary's Campus
London, W2 1NY
About this study
The purpose of the study is to assess the safety and efficacy of the Imperial College closed loop insulin delivery system (artificial pancreas) in subjects with type 1 diabetes.
Read the detailed description
Background:
Type 1 diabetes is caused by antibodies attacking insulin-producing β-cells in the pancreas. Treatment is usually by regular insulin injections, informed by glucose measurements from fingerprick blood samples. However, injections do not mimic the normal behaviour of the β-cell and this leads to suboptimal blood glucose control and complications including kidney failure, blindness, nerve damage and heart disease. Aggressive treatment can help but may lead to potentially-dangerous low blood glucose levels (hypoglycaemia). Glucose control is measured by HbA1c (normal range 4 to 6%), a measure of the amount of haemoglobin exposed to glucose over a period of around 3 months.
Current regimens for treating Type 1 diabetes in clinical practice are mainly based on injections of subcutaneous insulin several times daily in dosages determined by intermittent blood glucose measurements. The DCCT (Diabetes Control and Complications Trial) demonstrated that intensive management using these principles reduced complications by 50-76%. This was at the expense of increased hypoglycaemia, especially at HbA1c levels <7.5%. In other studies, intensive management resulted in people spending 30% of the day with glucose values >10mM and >2 hours/day in hypoglycaemia, often at night.
A closed loop system provides the potential to improve HbA1c while avoiding hypoglycaemia. It requires continuous glucose measurement, a control device and a pump for insulin delivery. The subject has been extensively reviewed. Intelligent control devices have been developed by others, using the principles of feedback control or predictive modelling. These were initially cumbersome e.g. the 'biostator' but more recent systems have been miniaturised and are capable of achieving blood glucose control in the fasting state, when provided with an input of interstitial glucose levels. They have not yet proven robust, may be associated with hypoglycaemia and are not capable of achieving adequate post-prandial control nor of coping with intercurrent illness outside hospital environments.
This clinical trial protocol assesses the Imperial College closed loop insulin delivery system. The closed loop insulin delivery comprises 3 main components: the glucose sensor, the control algorithm and the insulin delivery system.
The glucose sensor that will be used throughout the clinical validation studies is a CE marked, MHRA approved device manufactured by Medtronic. It is a subcutaneous sensor which sits just under the skin and samples interstitial fluid using an enzyme electrode. A small voltage is applied across the sensor and a current is fed back to the sensor instrumentation. This current is proportional to the glucose concentration in interstitial fluid and is calibrated against blood glucose a minimum of 12 hourly.
The control algorithm is derived from physiological experiments carried out by other groups which have demonstrated how the beta cells in the pancreas produce insulin in people without diabetes. Utilising the data from these experiments it has been possible to implement the behaviour of the beta cell in software and we have used a simulator with 200 virtual patients to demonstrate the safety and efficacy of the software. The data from the simulator is attached to this application as an appendix. The simulator was developed from human data and takes into account sensor errors, sensor placement, route of insulin administration and meal-time glucose absorption. It has been approved by the FDA in the United States as a step in the pathway of developing an artificial pancreas and has been validated against human data. In the clinical validation device the control algorithm is implemented on a printed circuit board using a programmable micro-controller.
The insulin pump device used throughout the clinical validation is the Roche Accu-Check Combo Spirit. This is a CE marked MHRA approved device and will be supplied by Roche with capability for direct communication from the motor so that we can verify the pump is doing what the software commands and with a license to use the communications protocol for research purposes. This ensures safe communication between the control algorithm and the pump and provides a fail-safe to ensure that the pump motor is responding appropriately to the control algorithm.
Clinical validation of the closed loop insulin delivery device follows a path of incremental challenges to the algorithm and hardware, starting with a fasting basal study in advisory mode and progressing to ambulatory, meal studies in full closed loop.
The aim of this trial is to assess the safety and efficacy of the closed loop device by applying the technology to participants with type 1 diabetes in a variety of scenarios, starting with a fasting test and progressing to overnight control, mealtime control and, finally, an ambulatory test.
Brief outline of each of the 5 visits within the trial period:
- Visit 1: Screening including clinical examination, fasting blood tests, completion of diabetes quality of life questionnaire, continuous glucose monitor attached to subject
- Visit 2: Review of continuous glucose monitoring results after 5 days
- Visit 3: Short Duration Fasting Closed Loop (6 hours of closed-loop assessment)
- Visit 4: Long Duration/ Overnight Fasting Closed Loop and Standard Meal Challenge (13 hours of closed-loop assessment)
- Visit 5: 24 Hour Ambulatory Automatic Closed Loop
During visits 3-5 blood sampling for capillary glucose \& ketones, venous glucose and insulin levels will take place every 15-30 minutes while the closed-loop insulin delivery system is running.
- Conditions
- Type 1 Diabetes Mellitus
- Being tested
- The Imperial College Closed-Loop Insulin Delivery System, Open loop
- Keywords
- Closed loop insulin delivery
- Medical subject headings
- Diabetes Mellitus, Type 1
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
The Imperial College Closed-Loop Insulin Delivery SystemDevice
Also called Closed-loop insulin delivery system, Artificial pancreas, Bio-inspired artificial pancreas
The Imperial College closed-loop insulin delivery system comprises 3 main components: the glucose sensor, the control algorithm and the insulin delivery system.
Open loopDevice
glucose sensor and pump
| Study group | Role | What they receive |
|---|---|---|
| Closed-loop insulin delivery | Experimental | The closed loop device (bio-inspired artificial pancreas device, subcutaneous glucose monitor and insulin pump) will be applied to participants with type 1 diabetes Receives: Device: The Imperial College Closed-Loop Insulin Delivery System |
| Open-loop (Control visit) | Active comparator | Subcutaneous glucose monitor and pump will be applied to participants with type 1 diabetes Receives: Device: Open loop |
What is being measured
The primary outcome is the main question the study is designed to answer.
Percentage Time in Euglycaemia
Interstitial blood glucose will be measured every 5 minutes and venous blood glucose every 15 minutes during subject visits 3, 4 and 5 when insulin is being delivered using the closed-loop insulin delivery system. The % time in euglycaemia is to be calculated using these blood glucose values.
Measured: 18 months
Secondary outcomes (7)
% Time in Hypoglycaemia
Interstitial blood glucose will be measured every 5 minutes and venous blood glucose every 15 minutes during subject visits 3, 4 and 5 when insulin is being delivered using the closed-loop insulin delivery system. The % time in hypoglycaemia is to be calculated using these blood glucose values.
Measured: 18 months
% Time Spent in Hyperglycaemia
Interstitial blood glucose will be measured every 5 minutes and venous blood glucose every 15 minutes during patient visits 3, 4 and 5 when insulin is being delivered using the closed-loop insulin delivery system. The % time in euglycaemia is to be calculated using these blood glucose values.
Measured: 18 months
Glycaemic Variability as Measured by MAGE and SD
Glycaemic variability as measured by MAGE and SD Calculation using CGM data
Measured: 18 months
Glycaemic Risk as Measured by LBGI and HBG
Glycaemic risk as measured by LBGI and HBG Calculation using CGM data
Measured: 18 months
Closed Loop Error Grid Analysis
Closed loop error grid analysis Calculation using CGM data
Measured: 18 months
Glucose Area Under the Curve
Glucose area under the curve Calculation using CGM data
Measured: 18 months
Insulin Requirement in Units/kg/hr
Calculation using average insulin delivered per hour and bodyweight
Measured: 18 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted16 Feb 2012 (estimated)
- Study startAug 2011
- Primary completionAug 2014
- Study completionAug 2018
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (11)Papers the sponsor has linked to this study.
- Other trials for Type 1 Diabetes MellitusStudies of the same condition, open and under way.
- More trials run by Imperial College LondonThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 23 participants (actual)
Sponsor and investigators
- Lead sponsor
- Imperial College London
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Desmond Johnston, MBChB,PhD,FRCP, Principal investigator, Imperial College London
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01534013
- Sponsor's protocol ID
- 13SM0363
- Status last verified
- Oct 2020
- First submitted
- 30 Jan 2012
- Last updated
- 30 Oct 2020
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
Publications
Georgiou P, Toumazou C. A silicon pancreatic Beta cell for diabetes. IEEE Trans Biomed Circuits Syst. 2007 Mar;1(1):39-49. doi: 10.1109/TBCAS.2007.893178.
PubMed 23851519Georgiou P, Toumazou C. Towards an ultra low power chemically inspired electronic beta cell for diabetes. Circuits and Systems, 2006. ISCAS 2006. Proceedings. 2006 IEEE International Symposium on, p. 173, 2006.
Ho M, Georgiou P, Singhal S, Oliver NS, Toumazou C. A bio-inspired closed loop insulin delivery based on the silicon pancreatic beta-cell. Circuits and Systems, 2008. ISCAS 2008. IEEE International Symposium on, pp. 1052-1055, 2008
Oliver N, Georgiou P, Johnston D, Toumazou C. A benchtop closed-loop system controlled by a bio-inspired silicon implementation of the pancreatic beta cell. J Diabetes Sci Technol. 2009 Nov 1;3(6):1419-24. doi: 10.1177/193229680900300623.
PubMed 20144397Hovorka R. Continuous glucose monitoring and closed-loop systems. Diabet Med. 2006 Jan;23(1):1-12. doi: 10.1111/j.1464-5491.2005.01672.x.
PubMed 16409558Nathan D, Cleary P, Backlund J, Genuth S, Lachin J, Orchard T, Raskin R, Zinman B. Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Study Research Group. Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes,
Albisser AM, Leibel BS, Ewart TG, Davidovac Z, Botz CK, Zingg W. An artificial endocrine pancreas. Diabetes. 1974 May;23(5):389-96. doi: 10.2337/diab.23.5.389. No abstract available.
PubMed 4598089Schaller HC, Schaupp L, Bodenlenz M, Wilinska ME, Chassin LJ, Wach P, Vering T, Hovorka R, Pieber TR. On-line adaptive algorithm with glucose prediction capacity for subcutaneous closed loop control of glucose: evaluation under fasting conditions in patients with Type 1 diabetes. Diabet Med. 2006 Jan;23(1):90-3. doi: 10.1111/j.1464-5491.2006.01695.x.
PubMed 16409572Kovatchev BP, Breton M, Man CD, Cobelli C. In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes. J Diabetes Sci Technol. 2009 Jan;3(1):44-55. doi: 10.1177/193229680900300106.
PubMed 19444330Thome-Duret V, Reach G, Gangnerau MN, Lemonnier F, Klein JC, Zhang Y, Hu Y, Wilson GS. Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood. Anal Chem. 1996 Nov 1;68(21):3822-6. doi: 10.1021/ac960069i.
PubMed 8914483Reddy M, Herrero P, El Sharkawy M, Pesl P, Jugnee N, Thomson H, Pavitt D, Toumazou C, Johnston D, Georgiou P, Oliver N. Feasibility study of a bio-inspired artificial pancreas in adults with type 1 diabetes. Diabetes Technol Ther. 2014 Sep;16(9):550-7. doi: 10.1089/dia.2014.0009. Epub 2014 May 6.
PubMed 24801544
Study at a glance
From the registry record, last updated by the sponsor on 30 Oct 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Clinical Assessment of a Closed-loop Insulin Delivery System
- ClinicalTrials.gov ID
- NCT01534013
- Acronym / sponsor ID
- 13SM0363
- Conditions
- Type 1 Diabetes Mellitus
- Keywords
- Closed loop insulin delivery
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 23 participants (actual)
- Lead sponsor
- Imperial College LondonUniversity, hospital or other
- Study start
- Aug 2011
- Primary completion
- Aug 2014 (actual)
- Study completion
- Aug 2018 (actual)
- First posted
- 16 Feb 2012 (estimated)
- Results
- Posted 28 Aug 2019
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of the study is to assess the safety and efficacy of the Imperial College closed loop insulin delivery system (artificial pancreas) in subjects with type 1 diabetes.
Detailed description
Background:
Type 1 diabetes is caused by antibodies attacking insulin-producing β-cells in the pancreas. Treatment is usually by regular insulin injections, informed by glucose measurements from fingerprick blood samples. However, injections do not mimic the normal behaviour of the β-cell and this leads to suboptimal blood glucose control and complications including kidney failure, blindness, nerve damage and heart disease. Aggressive treatment can help but may lead to potentially-dangerous low blood glucose levels (hypoglycaemia). Glucose control is measured by HbA1c (normal range 4 to 6%), a measure of the amount of haemoglobin exposed to glucose over a period of around 3 months.
Current regimens for treating Type 1 diabetes in clinical practice are mainly based on injections of subcutaneous insulin several times daily in dosages determined by intermittent blood glucose measurements. The DCCT (Diabetes Control and Complications Trial) demonstrated that intensive management using these principles reduced complications by 50-76%. This was at the expense of increased hypoglycaemia, especially at HbA1c levels <7.5%. In other studies, intensive management resulted in people spending 30% of the day with glucose values >10mM and >2 hours/day in hypoglycaemia, often at night.
A closed loop system provides the potential to improve HbA1c while avoiding hypoglycaemia. It requires continuous glucose measurement, a control device and a pump for insulin delivery. The subject has been extensively reviewed. Intelligent control devices have been developed by others, using the principles of feedback control or predictive modelling. These were initially cumbersome e.g. the 'biostator' but more recent systems have been miniaturised and are capable of achieving blood glucose control in the fasting state, when provided with an input of interstitial glucose levels. They have not yet proven robust, may be associated with hypoglycaemia and are not capable of achieving adequate post-prandial control nor of coping with intercurrent illness outside hospital environments.
This clinical trial protocol assesses the Imperial College closed loop insulin delivery system. The closed loop insulin delivery comprises 3 main components: the glucose sensor, the control algorithm and the insulin delivery system.
The glucose sensor that will be used throughout the clinical validation studies is a CE marked, MHRA approved device manufactured by Medtronic. It is a subcutaneous sensor which sits just under the skin and samples interstitial fluid using an enzyme electrode. A small voltage is applied across the sensor and a current is fed back to the sensor instrumentation. This current is proportional to the glucose concentration in interstitial fluid and is calibrated against blood glucose a minimum of 12 hourly.
The control algorithm is derived from physiological experiments carried out by other groups which have demonstrated how the beta cells in the pancreas produce insulin in people without diabetes. Utilising the data from these experiments it has been possible to implement the behaviour of the beta cell in software and we have used a simulator with 200 virtual patients to demonstrate the safety and efficacy of the software. The data from the simulator is attached to this application as an appendix. The simulator was developed from human data and takes into account sensor errors, sensor placement, route of insulin administration and meal-time glucose absorption. It has been approved by the FDA in the United States as a step in the pathway of developing an artificial pancreas and has been validated against human data. In the clinical validation device the control algorithm is implemented on a printed circuit board using a programmable micro-controller.
The insulin pump device used throughout the clinical validation is the Roche Accu-Check Combo Spirit. This is a CE marked MHRA approved device and will be supplied by Roche with capability for direct communication from the motor so that we can verify the pump is doing what the software commands and with a license to use the communications protocol for research purposes. This ensures safe communication between the control algorithm and the pump and provides a fail-safe to ensure that the pump motor is responding appropriately to the control algorithm.
Clinical validation of the closed loop insulin delivery device follows a path of incremental challenges to the algorithm and hardware, starting with a fasting basal study in advisory mode and progressing to ambulatory, meal studies in full closed loop.
The aim of this trial is to assess the safety and efficacy of the closed loop device by applying the technology to participants with type 1 diabetes in a variety of scenarios, starting with a fasting test and progressing to overnight control, mealtime control and, finally, an ambulatory test.
Brief outline of each of the 5 visits within the trial period:
- Visit 1: Screening including clinical examination, fasting blood tests, completion of diabetes quality of life questionnaire, continuous glucose monitor attached to subject
- Visit 2: Review of continuous glucose monitoring results after 5 days
- Visit 3: Short Duration Fasting Closed Loop (6 hours of closed-loop assessment)
- Visit 4: Long Duration/ Overnight Fasting Closed Loop and Standard Meal Challenge (13 hours of closed-loop assessment)
- Visit 5: 24 Hour Ambulatory Automatic Closed Loop
During visits 3-5 blood sampling for capillary glucose \& ketones, venous glucose and insulin levels will take place every 15-30 minutes while the closed-loop insulin delivery system is running.
Study design
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Closed-loop insulin delivery | Experimental | Device: The Imperial College Closed-Loop Insulin Delivery SystemThe closed loop device (bio-inspired artificial pancreas device, subcutaneous glucose monitor and insulin pump) will be applied to participants with type 1 diabetes |
| Open-loop (Control visit) | Active comparator | Device: Open loopSubcutaneous glucose monitor and pump will be applied to participants with type 1 diabetes |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Adults over 18 years of age
- Type 1 diabetes confirmed on the basis of clinical features and a fasting c-peptide <200nmol/L
- Type 1 diabetes for greater than 1 year
- Continuous subcutaneous insulin infusion for greater than 6 months
- HbA1c < 8.5% (69mmol/mol)
Key exclusion criteria (5 listed)
- Recurrent severe hypoglycaemia
- Pregnant or planning pregnancy
- Breastfeeding
- Enrolled in other clinical trials
- Have active malignancy or under investigation for malignancy
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| The Imperial College Closed-Loop Insulin Delivery SystemAlso: Closed-loop insulin delivery system, Artificial pancreas, Bio-inspired artificial pancreasThe Imperial College closed-loop insulin delivery system comprises 3 main components: the glucose sensor, the control algorithm and the insulin delivery system. | Device | Closed-loop insulin delivery |
| Open loopglucose sensor and pump | Device | Open-loop (Control visit) |
Primary outcome
Percentage Time in Euglycaemia
Time frame: 18 months
Interstitial blood glucose will be measured every 5 minutes and venous blood glucose every 15 minutes during subject visits 3, 4 and 5 when insulin is being delivered using the closed-loop insulin delivery system. The % time in euglycaemia is to be calculated using these blood glucose values.
7 secondary outcomes
% Time in Hypoglycaemia
Time frame: 18 months
% Time Spent in Hyperglycaemia
Time frame: 18 months
Glycaemic Variability as Measured by MAGE and SD
Time frame: 18 months
Glycaemic Risk as Measured by LBGI and HBG
Time frame: 18 months
Closed Loop Error Grid Analysis
Time frame: 18 months
Glucose Area Under the Curve
Time frame: 18 months
Insulin Requirement in Units/kg/hr
Time frame: 18 months
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 30 Oct 2020.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Background: PubMed 23851519Georgiou P, Toumazou C. A silicon pancreatic Beta cell for diabetes. IEEE Trans Biomed Circuits Syst. 2007 Mar;1(1):39-49. doi: 10.1109/TBCAS.2007.893178.
- BackgroundGeorgiou P, Toumazou C. Towards an ultra low power chemically inspired electronic beta cell for diabetes. Circuits and Systems, 2006. ISCAS 2006. Proceedings. 2006 IEEE International Symposium on, p. 173, 2006.
- BackgroundHo M, Georgiou P, Singhal S, Oliver NS, Toumazou C. A bio-inspired closed loop insulin delivery based on the silicon pancreatic beta-cell. Circuits and Systems, 2008. ISCAS 2008. IEEE International Symposium on, pp. 1052-1055, 2008
- Background: PubMed 20144397Oliver N, Georgiou P, Johnston D, Toumazou C. A benchtop closed-loop system controlled by a bio-inspired silicon implementation of the pancreatic beta cell. J Diabetes Sci Technol. 2009 Nov 1;3(6):1419-24. doi: 10.1177/193229680900300623.
- Background: PubMed 16409558Hovorka R. Continuous glucose monitoring and closed-loop systems. Diabet Med. 2006 Jan;23(1):1-12. doi: 10.1111/j.1464-5491.2005.01672.x.
- BackgroundNathan D, Cleary P, Backlund J, Genuth S, Lachin J, Orchard T, Raskin R, Zinman B. Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Study Research Group. Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes,
- Background: PubMed 4598089Albisser AM, Leibel BS, Ewart TG, Davidovac Z, Botz CK, Zingg W. An artificial endocrine pancreas. Diabetes. 1974 May;23(5):389-96. doi: 10.2337/diab.23.5.389. No abstract available.
- Background: PubMed 16409572Schaller HC, Schaupp L, Bodenlenz M, Wilinska ME, Chassin LJ, Wach P, Vering T, Hovorka R, Pieber TR. On-line adaptive algorithm with glucose prediction capacity for subcutaneous closed loop control of glucose: evaluation under fasting conditions in patients with Type 1 diabetes. Diabet Med. 2006 Jan;23(1):90-3. doi: 10.1111/j.1464-5491.2006.01695.x.
- Background: PubMed 19444330Kovatchev BP, Breton M, Man CD, Cobelli C. In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes. J Diabetes Sci Technol. 2009 Jan;3(1):44-55. doi: 10.1177/193229680900300106.
- Background: PubMed 8914483Thome-Duret V, Reach G, Gangnerau MN, Lemonnier F, Klein JC, Zhang Y, Hu Y, Wilson GS. Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood. Anal Chem. 1996 Nov 1;68(21):3822-6. doi: 10.1021/ac960069i.
- Derived from this study: PubMed 24801544Reddy M, Herrero P, El Sharkawy M, Pesl P, Jugnee N, Thomson H, Pavitt D, Toumazou C, Johnston D, Georgiou P, Oliver N. Feasibility study of a bio-inspired artificial pancreas in adults with type 1 diabetes. Diabetes Technol Ther. 2014 Sep;16(9):550-7. doi: 10.1089/dia.2014.0009. Epub 2014 May 6.
Related trials for Type 1 Diabetes Mellitus
Not yet recruitingPhase 3
A Study to Evaluate the Effectiveness and Safety of the Drug AZD6234 for Managing Weight in Adults Who Are Obese or Overweight. These Participants May or May Not Also Have Type 2 Diabetes
Obesity, Overweight
RecruitingPhase 1
Pharmacokinetics, Safety, and Immunogenicity Comparison of Bmab1700 and Opdivo® as Adjuvant Monotherapy in Participants With Melanoma
Melanoma
Active, not recruitingPhase 2
A Study of Botensilimab and Balstilimab for the Treatment of Colorectal Cancer
Metastatic Colorectal Cancer
Not yet recruiting
Inter-Arm Differences in Continuous Glucose Monitor Readings in Adults With Diabetes
Continuous Glucose Monitoring, Type 1 Diabetes
RecruitingObservational study
Estimated Risk of Preeclampsia in the First Trimester and Its Association With Subclinical Atherosclerosis and Cardiovascular Risk in Women With Type 1 Diabetes
Type 1 Diabetes, Preeclampsia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Desmond Johnston, MBChB,PhD,FRCP principal investigator
Imperial College London
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing The Imperial College Closed-Loop Insulin Delivery System and Open loop in people with Type 1 Diabetes Mellitus, run by Imperial College London at 1 site in United Kingdom.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 30 Oct 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 28 Aug 2019). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Percentage Time in Euglycaemia (time frame: 18 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01534013, which also lists 11 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Oct 2020; AzTrials last refreshed its copy on 6 Nov 2026.