Type 1 Diabetes MellitusNCT01534013

Clinical Assessment of a Closed-loop Insulin Delivery System

A study testing The Imperial College Closed-Loop Insulin Delivery System and Open loop in people with Type 1 Diabetes Mellitus, run by Imperial College London at 1 site in United Kingdom.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of the study is to assess the safety and efficacy of the Imperial College closed loop insulin delivery system (artificial pancreas) in subjects with type 1 diabetes. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Type 1 Diabetes Mellitus
What is being tested?
The Imperial College Closed-Loop Insulin Delivery System and Open loop
Could I receive a placebo?
No, everyone receives an active treatment
How many people
23 participants
Where
1 siteUnited Kingdom
Study dates
Aug 2011to Aug 2018
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adults over 18 years of age
  • Type 1 diabetes confirmed on the basis of clinical features and a fasting c-peptide <200nmol/L
  • Type 1 diabetes for greater than 1 year
  • Continuous subcutaneous insulin infusion for greater than 6 months
  • HbA1c < 8.5% (69mmol/mol)

Who cannot join

  • Recurrent severe hypoglycaemia
  • Pregnant or planning pregnancy
  • Breastfeeding
  • Enrolled in other clinical trials
  • Have active malignancy or under investigation for malignancy

Trial locations and contacts

1 site in 1 country.

United Kingdom1 site
  • Imperial College London, St Mary's Campus

    London, W2 1NY

Other trials in United Kingdom

About this study

The purpose of the study is to assess the safety and efficacy of the Imperial College closed loop insulin delivery system (artificial pancreas) in subjects with type 1 diabetes.

Read the detailed description

Background:

Type 1 diabetes is caused by antibodies attacking insulin-producing β-cells in the pancreas. Treatment is usually by regular insulin injections, informed by glucose measurements from fingerprick blood samples. However, injections do not mimic the normal behaviour of the β-cell and this leads to suboptimal blood glucose control and complications including kidney failure, blindness, nerve damage and heart disease. Aggressive treatment can help but may lead to potentially-dangerous low blood glucose levels (hypoglycaemia). Glucose control is measured by HbA1c (normal range 4 to 6%), a measure of the amount of haemoglobin exposed to glucose over a period of around 3 months.

Current regimens for treating Type 1 diabetes in clinical practice are mainly based on injections of subcutaneous insulin several times daily in dosages determined by intermittent blood glucose measurements. The DCCT (Diabetes Control and Complications Trial) demonstrated that intensive management using these principles reduced complications by 50-76%. This was at the expense of increased hypoglycaemia, especially at HbA1c levels <7.5%. In other studies, intensive management resulted in people spending 30% of the day with glucose values >10mM and >2 hours/day in hypoglycaemia, often at night.

A closed loop system provides the potential to improve HbA1c while avoiding hypoglycaemia. It requires continuous glucose measurement, a control device and a pump for insulin delivery. The subject has been extensively reviewed. Intelligent control devices have been developed by others, using the principles of feedback control or predictive modelling. These were initially cumbersome e.g. the 'biostator' but more recent systems have been miniaturised and are capable of achieving blood glucose control in the fasting state, when provided with an input of interstitial glucose levels. They have not yet proven robust, may be associated with hypoglycaemia and are not capable of achieving adequate post-prandial control nor of coping with intercurrent illness outside hospital environments.

This clinical trial protocol assesses the Imperial College closed loop insulin delivery system. The closed loop insulin delivery comprises 3 main components: the glucose sensor, the control algorithm and the insulin delivery system.

The glucose sensor that will be used throughout the clinical validation studies is a CE marked, MHRA approved device manufactured by Medtronic. It is a subcutaneous sensor which sits just under the skin and samples interstitial fluid using an enzyme electrode. A small voltage is applied across the sensor and a current is fed back to the sensor instrumentation. This current is proportional to the glucose concentration in interstitial fluid and is calibrated against blood glucose a minimum of 12 hourly.

The control algorithm is derived from physiological experiments carried out by other groups which have demonstrated how the beta cells in the pancreas produce insulin in people without diabetes. Utilising the data from these experiments it has been possible to implement the behaviour of the beta cell in software and we have used a simulator with 200 virtual patients to demonstrate the safety and efficacy of the software. The data from the simulator is attached to this application as an appendix. The simulator was developed from human data and takes into account sensor errors, sensor placement, route of insulin administration and meal-time glucose absorption. It has been approved by the FDA in the United States as a step in the pathway of developing an artificial pancreas and has been validated against human data. In the clinical validation device the control algorithm is implemented on a printed circuit board using a programmable micro-controller.

The insulin pump device used throughout the clinical validation is the Roche Accu-Check Combo Spirit. This is a CE marked MHRA approved device and will be supplied by Roche with capability for direct communication from the motor so that we can verify the pump is doing what the software commands and with a license to use the communications protocol for research purposes. This ensures safe communication between the control algorithm and the pump and provides a fail-safe to ensure that the pump motor is responding appropriately to the control algorithm.

Clinical validation of the closed loop insulin delivery device follows a path of incremental challenges to the algorithm and hardware, starting with a fasting basal study in advisory mode and progressing to ambulatory, meal studies in full closed loop.

The aim of this trial is to assess the safety and efficacy of the closed loop device by applying the technology to participants with type 1 diabetes in a variety of scenarios, starting with a fasting test and progressing to overnight control, mealtime control and, finally, an ambulatory test.

Brief outline of each of the 5 visits within the trial period:

  • Visit 1: Screening including clinical examination, fasting blood tests, completion of diabetes quality of life questionnaire, continuous glucose monitor attached to subject
  • Visit 2: Review of continuous glucose monitoring results after 5 days
  • Visit 3: Short Duration Fasting Closed Loop (6 hours of closed-loop assessment)
  • Visit 4: Long Duration/ Overnight Fasting Closed Loop and Standard Meal Challenge (13 hours of closed-loop assessment)
  • Visit 5: 24 Hour Ambulatory Automatic Closed Loop

During visits 3-5 blood sampling for capillary glucose \& ketones, venous glucose and insulin levels will take place every 15-30 minutes while the closed-loop insulin delivery system is running.

Being tested
The Imperial College Closed-Loop Insulin Delivery System, Open loop
Keywords
Closed loop insulin delivery
Medical subject headings
Diabetes Mellitus, Type 1

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • The Imperial College Closed-Loop Insulin Delivery SystemDevice

    Also called Closed-loop insulin delivery system, Artificial pancreas, Bio-inspired artificial pancreas

    The Imperial College closed-loop insulin delivery system comprises 3 main components: the glucose sensor, the control algorithm and the insulin delivery system.

  • Open loopDevice

    glucose sensor and pump

Study groups in NCT01534013
Study groupRoleWhat they receive
Closed-loop insulin deliveryExperimentalThe closed loop device (bio-inspired artificial pancreas device, subcutaneous glucose monitor and insulin pump) will be applied to participants with type 1 diabetes
Receives: Device: The Imperial College Closed-Loop Insulin Delivery System
Open-loop (Control visit)Active comparatorSubcutaneous glucose monitor and pump will be applied to participants with type 1 diabetes
Receives: Device: Open loop

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Percentage Time in Euglycaemia

    Interstitial blood glucose will be measured every 5 minutes and venous blood glucose every 15 minutes during subject visits 3, 4 and 5 when insulin is being delivered using the closed-loop insulin delivery system. The % time in euglycaemia is to be calculated using these blood glucose values.

    Measured: 18 months

Secondary outcomes (7)
  1. % Time in Hypoglycaemia

    Interstitial blood glucose will be measured every 5 minutes and venous blood glucose every 15 minutes during subject visits 3, 4 and 5 when insulin is being delivered using the closed-loop insulin delivery system. The % time in hypoglycaemia is to be calculated using these blood glucose values.

    Measured: 18 months

  2. % Time Spent in Hyperglycaemia

    Interstitial blood glucose will be measured every 5 minutes and venous blood glucose every 15 minutes during patient visits 3, 4 and 5 when insulin is being delivered using the closed-loop insulin delivery system. The % time in euglycaemia is to be calculated using these blood glucose values.

    Measured: 18 months

  3. Glycaemic Variability as Measured by MAGE and SD

    Glycaemic variability as measured by MAGE and SD Calculation using CGM data

    Measured: 18 months

  4. Glycaemic Risk as Measured by LBGI and HBG

    Glycaemic risk as measured by LBGI and HBG Calculation using CGM data

    Measured: 18 months

  5. Closed Loop Error Grid Analysis

    Closed loop error grid analysis Calculation using CGM data

    Measured: 18 months

  6. Glucose Area Under the Curve

    Glucose area under the curve Calculation using CGM data

    Measured: 18 months

  7. Insulin Requirement in Units/kg/hr

    Calculation using average insulin delivered per hour and bodyweight

    Measured: 18 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 Feb 2012 (estimated)
  2. Study startAug 2011
  3. Primary completionAug 2014
  4. Study completionAug 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Non-randomised
Intervention model
Single group
Masking
None (open label)
Enrolment
23 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01534013
Sponsor's protocol ID
13SM0363
Status last verified
Oct 2020
First submitted
30 Jan 2012
Last updated
30 Oct 2020
Data monitoring committee
Yes

Publications

  • Georgiou P, Toumazou C. A silicon pancreatic Beta cell for diabetes. IEEE Trans Biomed Circuits Syst. 2007 Mar;1(1):39-49. doi: 10.1109/TBCAS.2007.893178.

    PubMed 23851519
  • Georgiou P, Toumazou C. Towards an ultra low power chemically inspired electronic beta cell for diabetes. Circuits and Systems, 2006. ISCAS 2006. Proceedings. 2006 IEEE International Symposium on, p. 173, 2006.

  • Ho M, Georgiou P, Singhal S, Oliver NS, Toumazou C. A bio-inspired closed loop insulin delivery based on the silicon pancreatic beta-cell. Circuits and Systems, 2008. ISCAS 2008. IEEE International Symposium on, pp. 1052-1055, 2008

  • Oliver N, Georgiou P, Johnston D, Toumazou C. A benchtop closed-loop system controlled by a bio-inspired silicon implementation of the pancreatic beta cell. J Diabetes Sci Technol. 2009 Nov 1;3(6):1419-24. doi: 10.1177/193229680900300623.

    PubMed 20144397
  • Hovorka R. Continuous glucose monitoring and closed-loop systems. Diabet Med. 2006 Jan;23(1):1-12. doi: 10.1111/j.1464-5491.2005.01672.x.

    PubMed 16409558
  • Nathan D, Cleary P, Backlund J, Genuth S, Lachin J, Orchard T, Raskin R, Zinman B. Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Study Research Group. Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes,

  • Albisser AM, Leibel BS, Ewart TG, Davidovac Z, Botz CK, Zingg W. An artificial endocrine pancreas. Diabetes. 1974 May;23(5):389-96. doi: 10.2337/diab.23.5.389. No abstract available.

    PubMed 4598089
  • Schaller HC, Schaupp L, Bodenlenz M, Wilinska ME, Chassin LJ, Wach P, Vering T, Hovorka R, Pieber TR. On-line adaptive algorithm with glucose prediction capacity for subcutaneous closed loop control of glucose: evaluation under fasting conditions in patients with Type 1 diabetes. Diabet Med. 2006 Jan;23(1):90-3. doi: 10.1111/j.1464-5491.2006.01695.x.

    PubMed 16409572
  • Kovatchev BP, Breton M, Man CD, Cobelli C. In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes. J Diabetes Sci Technol. 2009 Jan;3(1):44-55. doi: 10.1177/193229680900300106.

    PubMed 19444330
  • Thome-Duret V, Reach G, Gangnerau MN, Lemonnier F, Klein JC, Zhang Y, Hu Y, Wilson GS. Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood. Anal Chem. 1996 Nov 1;68(21):3822-6. doi: 10.1021/ac960069i.

    PubMed 8914483
  • Reddy M, Herrero P, El Sharkawy M, Pesl P, Jugnee N, Thomson H, Pavitt D, Toumazou C, Johnston D, Georgiou P, Oliver N. Feasibility study of a bio-inspired artificial pancreas in adults with type 1 diabetes. Diabetes Technol Ther. 2014 Sep;16(9):550-7. doi: 10.1089/dia.2014.0009. Epub 2014 May 6.

    PubMed 24801544

Questions about this trial

What is this clinical trial studying?

A study testing The Imperial College Closed-Loop Insulin Delivery System and Open loop in people with Type 1 Diabetes Mellitus, run by Imperial College London at 1 site in United Kingdom.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 30 Oct 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 28 Aug 2019). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Percentage Time in Euglycaemia (time frame: 18 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01534013, which also lists 11 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Oct 2020; AzTrials last refreshed its copy on 6 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in