AzTrials
AzTrials

Aneurysmal Disease of the Ascending Aorta, the Arch and the Proximal Descending AortaPhase 1/2NCT01541410

Evaluation of the Vascutek Hybrid Graft for Use in the Replacement of the Aortic Arch and Concomitant Treatment of an Aneurysm/Dissection of the Descending Aorta in the Frozen Elephant Trunk Procedure

A Phase 1/2 study testing Vascutek Hybrid Graft in people with Aneurysmal Disease of the Ascending Aorta, the Arch and the Proximal Descending Aorta, run by Vascutek Ltd. at 1 site in Germany.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this feasibility study is to investigate the clinical performance of the Vascutek Hybrid Device in the treatment of subjects with aneurysm and/or dissection of the thoracic aorta. Read more about this study

Who is it for?
Ages 29 to 79 years
What is being tested?
Vascutek Hybrid Graft
Type of treatment
Medical device
How many people
34 participants
Where
1 siteGermany
Study dates
May 2010to Aug 2011
Phase
Phase 1/2
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 29 to 79 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients with aneurysm and/or dissection of the aortic arch and/or descending aorta
  • Patient must have agreed to participate voluntarily and have signed and dated an Ethics Committee approved Patient Informed Consent
  • Patient is able and willing to comply with the protocol and associated follow-up requirements

Who cannot join

  • Patients unfit for open surgical repair involving circulatory arrest
  • Endocarditis or active infective disorder of the aorta
  • Patients unwilling to give informed consent

Trial locations and contacts

1 site in 1 country.

Germany1 site
  • Division of Thoracic and Cardiovascular Surgery, Hannover Medical School

    Hanover, 30625

Other trials in Germany

About this study

The purpose of this feasibility study is to investigate the clinical performance of the Vascutek Hybrid Device in the treatment of subjects with aneurysm and/or dissection of the thoracic aorta.

Read the detailed description

The Vascutek Hybrid device is designed for use during a frozen elephant trunk procedure. Each system is comprised of a fully sealed traditional prosthesis which is stented at the distal end. A minimum of 10 and a maximum of 30 patients with aneurysmal disease of the ascending aorta, the arch and the proximal descending aorta will receive a hybrid prosthesis implanted without the use of the delivery system and a minimum of 10 patients and a maximum of 20 patients will be implanted with a hybrid device using the delivery system.

The traditional prosthesis component is representative of current Gelweave™ product. It is a woven polyester graft, crimped to maintain the lumen and gel coated to ensure that it will seal immediately. The stented section of the graft is a self-expanding endoprosthesis constructed of a thin wall woven polyester and Nitinol ring stents, which are attached to fabric with braided polyester sutures.

The delivery system is a central catheter comprised of a stainless steel braided, Isoplast-Pebax co-extrusion which has been locally strengthened to provide adequate guidewire lumen and sufficient stiffness to deploy the device. The outer sheath is 24Fr extruded PTFE with a groove to provide a localised splitting during deployment. The handle components are moulded in K-Resin \& thermoplastic polyurethane to fulfil the functional requirements of the product.

The compacted endoprosthesis is placed through the opened aortic arch and deployed leaving the stented section positioned inside the descending aorta. The device is then released from the delivery system and the handle components removed leaving the full graft in situ and correctly positioned. This allows the surgeon to complete the aortic arch repair as required.

The materials of the endoprosthesis section, and of the traditional prosthesis section of the Hybrid Device are identical to those of current Vascutek product (Anaconda™ Stent Graft System - endoprosthesis; and Gelweave™ - standard vascular graft). All materials used in the delivery system are well established in medical applications.

The Vascutek Ltd. Hybrid Device is produced using established manufacturing and Quality Control methodologies in an ISO 9001 and ISO 13485 certified system. The Hybrid Device is provided sterile for single use only. The method of sterilisation is ethylene oxide.

Being tested
Vascutek Hybrid Graft

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Vascutek Hybrid GraftDevice

    Single Group Assignment

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Primary Safety Endpoint

    The primary safety endpoint will be the proportion of subjects free from paraplegia, secondary conversion to conventional open surgical repair and death due to device or procedure related complications ≤30 days post-procedure.

    Measured: ≤30 days

  2. Primary Effectiveness Endpoint

    The primary effectiveness endpoint will be successful aneurysm treatment, defined as a composite endpoint of subjects who have successful delivery and deployment of the Vascutek Hybrid Device at the initial procedure and at ≤365 days post-procedure.

    Measured: ≤365 days

Secondary outcomes (2)
  1. Technical Success

    Technical success is defined as the placement and deployment of a Vascutek Hybrid Device in the absence of mortality, conversion to conventional open surgical repair, failed patency, evidence of an unanticipated distal type I or a type III endoleak on pre-discharge CT scan.

    Measured: Pre-discharge, 6 and 12 months

  2. Assessment of Stent Graft Migration and Integrity

    Stent graft migration will be defined as stent graft migration in excess of 10mm which requires secondary intervention. Structural integrity will be assessed primarily from plain x-ray and CT scan images and will be represented in binomial fashion.

    Measured: Pre-discharge, 6 and 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 Mar 2012 (estimated)
  2. Study startMay 2010
  3. Primary completionAug 2011

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 1/2
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
34 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01541410
Sponsor's protocol ID
HYBRID-001
Status last verified
Jul 2013
First submitted
13 Feb 2012
Last updated
15 Jul 2013
Results posted
No
Data monitoring committee
Yes

Questions about this trial

What is this clinical trial studying?

A Phase 1/2 study testing Vascutek Hybrid Graft in people with Aneurysmal Disease of the Ascending Aorta, the Arch and the Proximal Descending Aorta, run by Vascutek Ltd. at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 15 Jul 2013. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this combined phase mean?

Phase 1 studies test a treatment in a small group of people for the first time or in a new way, mainly to check safety and find the right dose.

Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Primary Safety Endpoint (time frame: ≤30 days). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Jul 2013.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in