Solid NeoplasmsNCT01543282
Endoscopic Ultrasonography (EUS) Guided Fine Needle Aspiration Using Free Stylet 22g and 25 g Needles
A study testing Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific) in people with Solid Neoplasms, run by Centre hospitalier de l'Université de Montréal (CHUM) at 1 site in Canada.
Trial summary
This is a randomized controlled study comparing EUS-FNA with 22 gauge and 25 gauge needles in consecutive patients. Summary Background: three needle sizes for endoscopic ultrasonography guided fine needle aspiration (EUS-FNA) are currently available: 22 Gauge (G), 25 G and 19 G. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Solid Neoplasms
- What is being tested?
- Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 120 participants
- Where
- 1 siteCanada
- Study dates
- 10 Dec 2011to Jul 2017
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Consecutive patients referred for EUS-FNA of a solid lesion.
Who cannot join
- Age < 18 years
- Patients with suspected diagnosis of lymphoma, GIST, sarcoidosis or other lesions in which a large amount of tissue will be required for diagnosis
- Significant coagulopathy (INR > 1.5, platelets < 50000/mm3
- Use of low molecular weight heparin, use of clopidogrel within 7 days of EUS)
- Cystic lesions
- Inability or refusal to sign the informed consent
Trial locations and contacts
1 site in 1 country.
Canada1 site
Hopital Saint Luc (Centre Hopitalier de l´Université du Montreal)
Montreal, Quebec, H2X3J4
About this study
Official title: Randomized Controlled Study Comparing Endoscopic Ultrasonography Guided Fine Needle Aspiration Using Free Stylet 22g and 25 g Needles in Solid Lesions
This is a randomized controlled study comparing EUS-FNA with 22 gauge and 25 gauge needles in consecutive patients.
Summary
Read more
Background: three needle sizes for endoscopic ultrasonography guided fine needle aspiration (EUS-FNA) are currently available: 22 Gauge (G), 25 G and 19 G. However, well design studies comparing them regarding efficacy and feasibility are lacking.
Aims: to investigate diagnostic yield, specimen adequacy, feasibility and complications of the conventional 22 G compared with the 25 G needle.
Methods: patients ≥ 18 years, referred to EUS-FNA for a solid lesion will be considered for inclusion. Patients with suspected diagnosis of lymphoma, GIST, sarcoidosis, significant coagulopathy (APT < 50% or platelets < 50000/mm3), use of warfarin or other anticoagulants, use of clopidogrel within 7 days of EUS, inability or refusal to sign the informed consent and pregnancy or suspected pregnancy will be excluded.
Participants will be randomized to 22 G needle and 25 G FNA. Chi-square test will be used to compare proportions. Continuous variables will be compared using Student´s t test. A two-tailed P values of less than 0.05 will be considered statistically significant. The diagnostic yield of 25 G and 22 G needle will be evaluated by four criteria: sensitivity, specificity, positive predictive value and negative predictive value. An expected rate of 85% diagnostic yield from EUS guided FNA by using 22G needle will be considered. By using a power of 80% and an α value of 0.05 would be necessary 120 patients per group to detect a 15% difference in the rate of diagnostic yield.
Read the detailed description
- Objectives
PRIMARY To compare diagnostic yield of stylet-free, solid lesion EUS-FNA using the 22 G FNA vs the 25 G FNA needle, in consecutive patients referred to EUS-FNA.
SECONDARY
To investigate:
- specimen adequacy,
- number of FNA passes,
- ease of puncture,
- failure of the FNA needle and
- complications
- Methods
3.1. Design: prospective randomized trial.
3.2. Inclusion: Consecutive patients referred for EUS-FNA of a solid lesion will be considered for inclusion.
3.3. Exclusion: Age < 18 years, patients with suspected diagnosis of lymphoma, GIST, sarcoidosis or other lesions in which a large amount of tissue will be required for diagnosis, significant coagulopathy (INR > 1.5, platelets < 50000/mm3, use of low molecular weight heparin, use of clopidogrel within 7 days of EUS), cystic lesions, or inability or refusal to sign the informed consent.
3.4. Endoscopic procedures: Informed consent will be obtained before each procedure by one of the researchers. Patients will not receive economic compensation or reimbursement of their expenses for coming to the exploration, since it is a procedure previously indicated. Then, potential candidates will be randomized to 22 G or 25 G FNA using a computer generated random sequence. There will be block randomization for a) pancreatic masses, 2) lymph nodes, or 3) all other lesions.
All examinations will be performed by two experienced endosonographers with a lineal echoendoscope (AS and SP). EUS procedures will be carried out with the patient, in left lateral position under conscious sedation using midazolam (2.5-5 mg) plus meperidine (50-100 mg) and droperidol (2.5-5 mg). Before performing the EUS-FNA biopsy, a complete examination of the pancreas, liver as well as other vicinity organs will be performed.
EUS-FNA passes will be performed without stylet until sample adequacy or until a maximum of 5 FNA passes in pancreatic lesions or 3 FNA passes in other lesions. In case of inadequate sample after 3 passes, or needle failure, cross over to the other type of needle is allowed. Ease of puncture will be scored qualitatively as poor (scored 1), good (scored 2) or excellent (scored 3).[14] FNA failure will be also reported. All procedures will be digitally videotaped. The examinations will be reviewed by a endosonographer blinded to the type of needle used and visibility of the needle will be scored (score 1 "poor", score 2 "good", score 3 "excellent").[14] After the procedure, patients will be monitored in the recovery room at least 60 minutes before discharge. Immediate complications will be assessed and recorded by nurses and/or physicians during and after the procedure while the patient was recovering from sedation.
3.5. Cytological analysis: All passes will be read by one experienced cytopathologist on-site utilizing microscopic evaluation of air-dried slides stained with Diff-Quik (International Reagents Co., Ltd., Kobe, Japan). The cytopathologist will be blinded to the type of needle used. The final cytological diagnosis was made using a standard Papanicolaou stain. For each lesion, the cytologist assessed sample adequacy: cellularity (score 1 "poor", score 2 "good", score 3 "excellent"),[14] and bloodiness (score 1 "minimal", score 2 "moderate", score 3 "significant")[21] and the presence or absence of malignancy ("positive"/"negative"/"suspicious"/ inconclusive).
3.6. Follow up Lesions will be considered malignant in the following cases: positive cytological diagnosis, positive histological diagnosis and clinical or radiological progression in the next 6 months. In case of negative results in the cytological diagnosis absence of clinical worsening and radiologic progression at least in the following 6 months after FNA will be required.
3.7. Data collection Clinical data will be prospectively collected and saved in a database including: demographic information (age and gender), size and location of the target lesion (pancreas, lymph node, liver, adrenal gland, others) and technical and procedure variables: FNA path (esophagus, stomach, duodenum), number of needle passes, needle visibility, ease to puncture, needle failure, cellularity, bloodiness, cytological diagnosis, final diagnosis, immediate complications.
- Statistical analysis Results for continuous variables will be expressed as means and standard deviations. Categorical variables will be expressed as frequencies and percentages. Chi-square test will be used to compare proportions. Continuous variables will be compared using Student´s t test. A two-tailed P values of less than 0.05 will be considered statistically significant. Data were analyzed with the Statistical Package for Social Sciences v. 15.0 (SPSS Inc., Chicago, IL, USA). The diagnostic yield of 15 G and 22 G needle will be evaluated by four criteria: sensitivity, specificity, positive predictive value and negative predictive value.
Sample size An expected rate of diagnostic yield from EUS guided FNA by using 22G needle of 85% will be considered. By using a power of 80% and an α value of 0.05 would be necessary 120 patients per group to detect a 15% difference in the rate of diagnostic yield.
- Conditions
- Solid Neoplasms
- Being tested
- Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific)
- Keywords
- endoscopic ultrasonography, fine needle aspiration cytology, 22 gauge, 25 gauge
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific)Device
Also called Cook Medical, Boston Scientific
Patients will be randomized either to receive EUS-FNA with a 22 g needle or 25 g needle. EUS-FNA passes will be performed without stylet until sample adequacy or until a maximum of 5 FNA passes in pancreatic lesions or 3 FNA passes in other lesions. In case of inadequate sample after 3 passes, or needle failure, cross over to the other type of needle is allowed.
| Study group | Role | What they receive |
|---|---|---|
| EUS 22 gauge needle | Active comparator | EUS 22 g needle is the most common needle used in clinical practice. EUS-FNA passes will be performed without stylet until sample adequacy or until a maximum of 5 FNA passes in pancreatic lesions or 3 FNA passes in other lesions. In case of inadequate sample after 3 passes, or needle failure, cross over to the other type of needle is allowed. Receives: Device: Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific) |
| EUS 25 gauge needle | Experimental | 25 gauge needle is usually used less frequently but nowadays is increasingly used and is as well a valid option. EUS-FNA passes will be performed without stylet until sample adequacy or until a maximum of 5 FNA passes in pancreatic lesions or 3 FNA passes in other lesions. In case of inadequate sample after 3 passes, or needle failure, cross over to the other type of needle is allowed. Receives: Device: Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific) |
What is being measured
The primary outcome is the main question the study is designed to answer.
Accuracy of stylet-free, solid lesion EUS-FNA using the 22 G FNA vs the 25 G FNA needle, in consecutive patients referred to EUS-FNA.
Measured: 6 months
Secondary outcomes (1)
Specimen adequacy, number of FNA passes, ease of puncture, failure of the FNA needle and complications
Measured: 6 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted2 Mar 2012 (estimated)
- Study start10 Dec 2011
- Primary completionJul 2017
- Study completionJul 2017
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (7)Papers the sponsor has linked to this study.
- Other trials for Solid NeoplasmsStudies of the same condition, open and under way.
- More trials run by Centre hospitalier de l'Université de Montréal (CHUM)The sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 120 participants (actual)
Sponsor and investigators
- Sponsor type
- University, hospital or other
- Collaborators
- Centre de Recherche du Centre Hospitalier de l'Université de Montréal
- Responsible party
- Sponsor
- Investigators
- Anand V Sahai, MD, Principal investigator, Hopital Saint Luc (Centre Hopitalier de l´Université du Montreal) Montreal, Quebec, Canada
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01543282
- Sponsor's protocol ID
- CE 11.150
- Status last verified
- May 2020
- First submitted
- 15 Dec 2011
- Last updated
- 22 May 2020
- Results posted
- No
- Data monitoring committee
- Yes
Publications
Yusuf TE, Ho S, Pavey DA, Michael H, Gress FG. Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience. Endoscopy. 2009 May;41(5):445-8. doi: 10.1055/s-0029-1214643. Epub 2009 May 5.
PubMed 19418399Imazu H, Uchiyama Y, Kakutani H, Ikeda K, Sumiyama K, Kaise M, Omar S, Ang TL, Tajiri H. A prospective comparison of EUS-guided FNA using 25-gauge and 22-gauge needles. Gastroenterol Res Pract. 2009;2009:546390. doi: 10.1155/2009/546390. Epub 2009 Nov 17.
PubMed 19997511Lee JH, Stewart J, Ross WA, Anandasabapathy S, Xiao L, Staerkel G. Blinded prospective comparison of the performance of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of the pancreas and peri-pancreatic lesions. Dig Dis Sci. 2009 Oct;54(10):2274-81. doi: 10.1007/s10620-009-0906-1. Epub 2009 Aug 11.
PubMed 19669880Sakamoto H, Kitano M, Komaki T, Noda K, Chikugo T, Dote K, Takeyama Y, Das K, Yamao K, Kudo M. Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge Trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses. J Gastroenterol Hepatol. 2009 Mar;24(3):384-90. doi: 10.1111/j.1440-1746.2008.05636.x. Epub 2008 Nov 20.
PubMed 19032453Camellini L, Carlinfante G, Azzolini F, Iori V, Cavina M, Sereni G, Decembrino F, Gallo C, Tamagnini I, Valli R, Piana S, Campari C, Gardini G, Sassatelli R. A randomized clinical trial comparing 22G and 25G needles in endoscopic ultrasound-guided fine-needle aspiration of solid lesions. Endoscopy. 2011 Aug;43(8):709-15. doi: 10.1055/s-0030-1256482. Epub 2011 May 24.
PubMed 21611946Fabbri C, Polifemo AM, Luigiano C, Cennamo V, Baccarini P, Collina G, Fornelli A, Macchia S, Zanini N, Jovine E, Fiscaletti M, Alibrandi A, D'Imperio N. Endoscopic ultrasound-guided fine needle aspiration with 22- and 25-gauge needles in solid pancreatic masses: a prospective comparative study with randomisation of needle sequence. Dig Liver Dis. 2011 Aug;43(8):647-52. doi: 10.1016/j.dld.2011.04.005. Epub 2011 May 17.
PubMed 21592873Wani S, Gupta N, Gaddam S, Singh V, Ulusarac O, Romanas M, Bansal A, Sharma P, Olyaee MS, Rastogi A. A comparative study of endoscopic ultrasound guided fine needle aspiration with and without a stylet. Dig Dis Sci. 2011 Aug;56(8):2409-14. doi: 10.1007/s10620-011-1608-z. Epub 2011 Feb 17.
PubMed 21327919
Study at a glance
From the registry record, last updated by the sponsor on 22 May 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Randomized Controlled Study Comparing Endoscopic Ultrasonography Guided Fine Needle Aspiration Using Free Stylet 22g and 25 g Needles in Solid Lesions
- ClinicalTrials.gov ID
- NCT01543282
- Acronym / sponsor ID
- CE 11.150
- Conditions
- Solid Neoplasms
- Keywords
- endoscopic ultrasonography, fine needle aspiration cytology, 22 gauge, 25 gauge
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 120 participants (actual)
- Lead sponsor
- Centre hospitalier de l'Université de Montréal (CHUM)University, hospital or other
- Collaborators
- Centre de Recherche du Centre Hospitalier de l'Université de Montréal
- Study start
- 10 Dec 2011 (actual)
- Primary completion
- Jul 2017 (actual)
- Study completion
- Jul 2017 (actual)
- First posted
- 2 Mar 2012 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is a randomized controlled study comparing EUS-FNA with 22 gauge and 25 gauge needles in consecutive patients.
Summary
Background: three needle sizes for endoscopic ultrasonography guided fine needle aspiration (EUS-FNA) are currently available: 22 Gauge (G), 25 G and 19 G. However, well design studies comparing them regarding efficacy and feasibility are lacking.
Aims: to investigate diagnostic yield, specimen adequacy, feasibility and complications of the conventional 22 G compared with the 25 G needle.
Methods: patients ≥ 18 years, referred to EUS-FNA for a solid lesion will be considered for inclusion. Patients with suspected diagnosis of lymphoma, GIST, sarcoidosis, significant coagulopathy (APT < 50% or platelets < 50000/mm3), use of warfarin or other anticoagulants, use of clopidogrel within 7 days of EUS, inability or refusal to sign the informed consent and pregnancy or suspected pregnancy will be excluded.
Participants will be randomized to 22 G needle and 25 G FNA. Chi-square test will be used to compare proportions. Continuous variables will be compared using Student´s t test. A two-tailed P values of less than 0.05 will be considered statistically significant. The diagnostic yield of 25 G and 22 G needle will be evaluated by four criteria: sensitivity, specificity, positive predictive value and negative predictive value. An expected rate of 85% diagnostic yield from EUS guided FNA by using 22G needle will be considered. By using a power of 80% and an α value of 0.05 would be necessary 120 patients per group to detect a 15% difference in the rate of diagnostic yield.
Detailed description
- Objectives
PRIMARY To compare diagnostic yield of stylet-free, solid lesion EUS-FNA using the 22 G FNA vs the 25 G FNA needle, in consecutive patients referred to EUS-FNA.
SECONDARY
To investigate:
- specimen adequacy,
- number of FNA passes,
- ease of puncture,
- failure of the FNA needle and
- complications
- Methods
3.1. Design: prospective randomized trial.
3.2. Inclusion: Consecutive patients referred for EUS-FNA of a solid lesion will be considered for inclusion.
3.3. Exclusion: Age < 18 years, patients with suspected diagnosis of lymphoma, GIST, sarcoidosis or other lesions in which a large amount of tissue will be required for diagnosis, significant coagulopathy (INR > 1.5, platelets < 50000/mm3, use of low molecular weight heparin, use of clopidogrel within 7 days of EUS), cystic lesions, or inability or refusal to sign the informed consent.
3.4. Endoscopic procedures: Informed consent will be obtained before each procedure by one of the researchers. Patients will not receive economic compensation or reimbursement of their expenses for coming to the exploration, since it is a procedure previously indicated. Then, potential candidates will be randomized to 22 G or 25 G FNA using a computer generated random sequence. There will be block randomization for a) pancreatic masses, 2) lymph nodes, or 3) all other lesions.
All examinations will be performed by two experienced endosonographers with a lineal echoendoscope (AS and SP). EUS procedures will be carried out with the patient, in left lateral position under conscious sedation using midazolam (2.5-5 mg) plus meperidine (50-100 mg) and droperidol (2.5-5 mg). Before performing the EUS-FNA biopsy, a complete examination of the pancreas, liver as well as other vicinity organs will be performed.
EUS-FNA passes will be performed without stylet until sample adequacy or until a maximum of 5 FNA passes in pancreatic lesions or 3 FNA passes in other lesions. In case of inadequate sample after 3 passes, or needle failure, cross over to the other type of needle is allowed. Ease of puncture will be scored qualitatively as poor (scored 1), good (scored 2) or excellent (scored 3).[14] FNA failure will be also reported. All procedures will be digitally videotaped. The examinations will be reviewed by a endosonographer blinded to the type of needle used and visibility of the needle will be scored (score 1 "poor", score 2 "good", score 3 "excellent").[14] After the procedure, patients will be monitored in the recovery room at least 60 minutes before discharge. Immediate complications will be assessed and recorded by nurses and/or physicians during and after the procedure while the patient was recovering from sedation.
3.5. Cytological analysis: All passes will be read by one experienced cytopathologist on-site utilizing microscopic evaluation of air-dried slides stained with Diff-Quik (International Reagents Co., Ltd., Kobe, Japan). The cytopathologist will be blinded to the type of needle used. The final cytological diagnosis was made using a standard Papanicolaou stain. For each lesion, the cytologist assessed sample adequacy: cellularity (score 1 "poor", score 2 "good", score 3 "excellent"),[14] and bloodiness (score 1 "minimal", score 2 "moderate", score 3 "significant")[21] and the presence or absence of malignancy ("positive"/"negative"/"suspicious"/ inconclusive).
3.6. Follow up Lesions will be considered malignant in the following cases: positive cytological diagnosis, positive histological diagnosis and clinical or radiological progression in the next 6 months. In case of negative results in the cytological diagnosis absence of clinical worsening and radiologic progression at least in the following 6 months after FNA will be required.
3.7. Data collection Clinical data will be prospectively collected and saved in a database including: demographic information (age and gender), size and location of the target lesion (pancreas, lymph node, liver, adrenal gland, others) and technical and procedure variables: FNA path (esophagus, stomach, duodenum), number of needle passes, needle visibility, ease to puncture, needle failure, cellularity, bloodiness, cytological diagnosis, final diagnosis, immediate complications.
- Statistical analysis Results for continuous variables will be expressed as means and standard deviations. Categorical variables will be expressed as frequencies and percentages. Chi-square test will be used to compare proportions. Continuous variables will be compared using Student´s t test. A two-tailed P values of less than 0.05 will be considered statistically significant. Data were analyzed with the Statistical Package for Social Sciences v. 15.0 (SPSS Inc., Chicago, IL, USA). The diagnostic yield of 15 G and 22 G needle will be evaluated by four criteria: sensitivity, specificity, positive predictive value and negative predictive value.
Sample size An expected rate of diagnostic yield from EUS guided FNA by using 22G needle of 85% will be considered. By using a power of 80% and an α value of 0.05 would be necessary 120 patients per group to detect a 15% difference in the rate of diagnostic yield.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| EUS 22 gauge needle | Active comparator | Device: Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific)EUS 22 g needle is the most common needle used in clinical practice. EUS-FNA passes will be performed without stylet until sample adequacy or until a maximum of 5 FNA passes in pancreatic lesions or 3 FNA passes in other lesions. In case of inadequate sample after 3 passes, or needle failure, cross over to the other type of needle is allowed. |
| EUS 25 gauge needle | Experimental | Device: Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific)25 gauge needle is usually used less frequently but nowadays is increasingly used and is as well a valid option. EUS-FNA passes will be performed without stylet until sample adequacy or until a maximum of 5 FNA passes in pancreatic lesions or 3 FNA passes in other lesions. In case of inadequate sample after 3 passes, or needle failure, cross over to the other type of needle is allowed. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- Consecutive patients referred for EUS-FNA of a solid lesion.
Key exclusion criteria (6 listed)
- Age < 18 years
- Patients with suspected diagnosis of lymphoma, GIST, sarcoidosis or other lesions in which a large amount of tissue will be required for diagnosis
- Significant coagulopathy (INR > 1.5, platelets < 50000/mm3
- Use of low molecular weight heparin, use of clopidogrel within 7 days of EUS)
- Cystic lesions
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific)Also: Cook Medical, Boston ScientificPatients will be randomized either to receive EUS-FNA with a 22 g needle or 25 g needle. EUS-FNA passes will be performed without stylet until sample adequacy or until a maximum of 5 FNA passes in pancreatic lesions or 3 FNA passes in other lesions. In case of inadequate sample after 3 passes, or needle failure, cross over to the other type of needle is allowed. | Device | EUS 22 gauge needle, EUS 25 gauge needle |
Primary outcome
Accuracy of stylet-free, solid lesion EUS-FNA using the 22 G FNA vs the 25 G FNA needle, in consecutive patients referred to EUS-FNA.
Time frame: 6 months
1 secondary outcome
Specimen adequacy, number of FNA passes, ease of puncture, failure of the FNA needle and complications
Time frame: 6 months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 22 May 2020.
- Results publication: PubMed 19418399Yusuf TE, Ho S, Pavey DA, Michael H, Gress FG. Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience. Endoscopy. 2009 May;41(5):445-8. doi: 10.1055/s-0029-1214643. Epub 2009 May 5.
- Results publication: PubMed 19997511Imazu H, Uchiyama Y, Kakutani H, Ikeda K, Sumiyama K, Kaise M, Omar S, Ang TL, Tajiri H. A prospective comparison of EUS-guided FNA using 25-gauge and 22-gauge needles. Gastroenterol Res Pract. 2009;2009:546390. doi: 10.1155/2009/546390. Epub 2009 Nov 17.
- Results publication: PubMed 19669880Lee JH, Stewart J, Ross WA, Anandasabapathy S, Xiao L, Staerkel G. Blinded prospective comparison of the performance of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of the pancreas and peri-pancreatic lesions. Dig Dis Sci. 2009 Oct;54(10):2274-81. doi: 10.1007/s10620-009-0906-1. Epub 2009 Aug 11.
- Results publication: PubMed 19032453Sakamoto H, Kitano M, Komaki T, Noda K, Chikugo T, Dote K, Takeyama Y, Das K, Yamao K, Kudo M. Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge Trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses. J Gastroenterol Hepatol. 2009 Mar;24(3):384-90. doi: 10.1111/j.1440-1746.2008.05636.x. Epub 2008 Nov 20.
- Results publication: PubMed 21611946Camellini L, Carlinfante G, Azzolini F, Iori V, Cavina M, Sereni G, Decembrino F, Gallo C, Tamagnini I, Valli R, Piana S, Campari C, Gardini G, Sassatelli R. A randomized clinical trial comparing 22G and 25G needles in endoscopic ultrasound-guided fine-needle aspiration of solid lesions. Endoscopy. 2011 Aug;43(8):709-15. doi: 10.1055/s-0030-1256482. Epub 2011 May 24.
- Results publication: PubMed 21592873Fabbri C, Polifemo AM, Luigiano C, Cennamo V, Baccarini P, Collina G, Fornelli A, Macchia S, Zanini N, Jovine E, Fiscaletti M, Alibrandi A, D'Imperio N. Endoscopic ultrasound-guided fine needle aspiration with 22- and 25-gauge needles in solid pancreatic masses: a prospective comparative study with randomisation of needle sequence. Dig Liver Dis. 2011 Aug;43(8):647-52. doi: 10.1016/j.dld.2011.04.005. Epub 2011 May 17.
- Results publication: PubMed 21327919Wani S, Gupta N, Gaddam S, Singh V, Ulusarac O, Romanas M, Bansal A, Sharma P, Olyaee MS, Rastogi A. A comparative study of endoscopic ultrasound guided fine needle aspiration with and without a stylet. Dig Dis Sci. 2011 Aug;56(8):2409-14. doi: 10.1007/s10620-011-1608-z. Epub 2011 Feb 17.
Related trials for Solid Neoplasms
RecruitingPhase 2
A Study of Amivantamab in Participants With Advanced or Metastatic Solid Tumors Including Epidermal Growth Factor Receptor (EGFR)-Mutated Non-Small Cell Lung Cancer
Carcinoma, Non-small-Cell Lung
RecruitingPhase 1
A Study of JNJ-95437446 in Participants With Advanced-Stage Solid Tumors
Advanced Stage Solid Tumors
RecruitingPhase 1/2
A Phase 1 and 2 Study of VMD-102 in Hepatocellular Carcinoma and Other Solid Tumors
Hepatocellular Carcinoma (HCC), Metastatic Uveal Melanoma
RecruitingPhase 1
A Study of JNJ-1761981 in Participants With Solid Tumors
Neoplasms
Not yet recruitingPhase 1
GD2IL18CART Combined With Bevacizumab for Relapsed and Refractory GD2-positive Solid Tumors
Neuroblastoma (NBL), Ewing Sarcoma
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Anand V Sahai, MD principal investigator
Hopital Saint Luc (Centre Hopitalier de l´Université du Montreal) Montreal, Quebec, Canada
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific) in people with Solid Neoplasms, run by Centre hospitalier de l'Université de Montréal (CHUM) at 1 site in Canada.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 22 May 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Accuracy of stylet-free, solid lesion EUS-FNA using the 22 G FNA vs the 25 G FNA needle, in consecutive patients referred to EUS-FNA. (time frame: 6 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01543282, which also lists 7 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 May 2020.