AzTrials
AzTrials

Solid NeoplasmsNCT01543282

Endoscopic Ultrasonography (EUS) Guided Fine Needle Aspiration Using Free Stylet 22g and 25 g Needles

A study testing Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific) in people with Solid Neoplasms, run by Centre hospitalier de l'Université de Montréal (CHUM) at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This is a randomized controlled study comparing EUS-FNA with 22 gauge and 25 gauge needles in consecutive patients. Summary Background: three needle sizes for endoscopic ultrasonography guided fine needle aspiration (EUS-FNA) are currently available: 22 Gauge (G), 25 G and 19 G. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Solid Neoplasms
What is being tested?
Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
120 participants
Where
1 siteCanada
Study dates
10 Dec 2011to Jul 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Consecutive patients referred for EUS-FNA of a solid lesion.

Who cannot join

  • Age < 18 years
  • Patients with suspected diagnosis of lymphoma, GIST, sarcoidosis or other lesions in which a large amount of tissue will be required for diagnosis
  • Significant coagulopathy (INR > 1.5, platelets < 50000/mm3
  • Use of low molecular weight heparin, use of clopidogrel within 7 days of EUS)
  • Cystic lesions
  • Inability or refusal to sign the informed consent

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • Hopital Saint Luc (Centre Hopitalier de l´Université du Montreal)

    Montreal, Quebec, H2X3J4

Other trials in Canada

About this study

Official title: Randomized Controlled Study Comparing Endoscopic Ultrasonography Guided Fine Needle Aspiration Using Free Stylet 22g and 25 g Needles in Solid Lesions

This is a randomized controlled study comparing EUS-FNA with 22 gauge and 25 gauge needles in consecutive patients.

Summary

Read more

Background: three needle sizes for endoscopic ultrasonography guided fine needle aspiration (EUS-FNA) are currently available: 22 Gauge (G), 25 G and 19 G. However, well design studies comparing them regarding efficacy and feasibility are lacking.

Aims: to investigate diagnostic yield, specimen adequacy, feasibility and complications of the conventional 22 G compared with the 25 G needle.

Methods: patients ≥ 18 years, referred to EUS-FNA for a solid lesion will be considered for inclusion. Patients with suspected diagnosis of lymphoma, GIST, sarcoidosis, significant coagulopathy (APT < 50% or platelets < 50000/mm3), use of warfarin or other anticoagulants, use of clopidogrel within 7 days of EUS, inability or refusal to sign the informed consent and pregnancy or suspected pregnancy will be excluded.

Participants will be randomized to 22 G needle and 25 G FNA. Chi-square test will be used to compare proportions. Continuous variables will be compared using Student´s t test. A two-tailed P values of less than 0.05 will be considered statistically significant. The diagnostic yield of 25 G and 22 G needle will be evaluated by four criteria: sensitivity, specificity, positive predictive value and negative predictive value. An expected rate of 85% diagnostic yield from EUS guided FNA by using 22G needle will be considered. By using a power of 80% and an α value of 0.05 would be necessary 120 patients per group to detect a 15% difference in the rate of diagnostic yield.

Read the detailed description
  1. Objectives

PRIMARY To compare diagnostic yield of stylet-free, solid lesion EUS-FNA using the 22 G FNA vs the 25 G FNA needle, in consecutive patients referred to EUS-FNA.

SECONDARY

To investigate:

  1. specimen adequacy,
  2. number of FNA passes,
  3. ease of puncture,
  4. failure of the FNA needle and
  5. complications
  6. Methods

3.1. Design: prospective randomized trial.

3.2. Inclusion: Consecutive patients referred for EUS-FNA of a solid lesion will be considered for inclusion.

3.3. Exclusion: Age < 18 years, patients with suspected diagnosis of lymphoma, GIST, sarcoidosis or other lesions in which a large amount of tissue will be required for diagnosis, significant coagulopathy (INR > 1.5, platelets < 50000/mm3, use of low molecular weight heparin, use of clopidogrel within 7 days of EUS), cystic lesions, or inability or refusal to sign the informed consent.

3.4. Endoscopic procedures: Informed consent will be obtained before each procedure by one of the researchers. Patients will not receive economic compensation or reimbursement of their expenses for coming to the exploration, since it is a procedure previously indicated. Then, potential candidates will be randomized to 22 G or 25 G FNA using a computer generated random sequence. There will be block randomization for a) pancreatic masses, 2) lymph nodes, or 3) all other lesions.

All examinations will be performed by two experienced endosonographers with a lineal echoendoscope (AS and SP). EUS procedures will be carried out with the patient, in left lateral position under conscious sedation using midazolam (2.5-5 mg) plus meperidine (50-100 mg) and droperidol (2.5-5 mg). Before performing the EUS-FNA biopsy, a complete examination of the pancreas, liver as well as other vicinity organs will be performed.

EUS-FNA passes will be performed without stylet until sample adequacy or until a maximum of 5 FNA passes in pancreatic lesions or 3 FNA passes in other lesions. In case of inadequate sample after 3 passes, or needle failure, cross over to the other type of needle is allowed. Ease of puncture will be scored qualitatively as poor (scored 1), good (scored 2) or excellent (scored 3).[14] FNA failure will be also reported. All procedures will be digitally videotaped. The examinations will be reviewed by a endosonographer blinded to the type of needle used and visibility of the needle will be scored (score 1 "poor", score 2 "good", score 3 "excellent").[14] After the procedure, patients will be monitored in the recovery room at least 60 minutes before discharge. Immediate complications will be assessed and recorded by nurses and/or physicians during and after the procedure while the patient was recovering from sedation.

3.5. Cytological analysis: All passes will be read by one experienced cytopathologist on-site utilizing microscopic evaluation of air-dried slides stained with Diff-Quik (International Reagents Co., Ltd., Kobe, Japan). The cytopathologist will be blinded to the type of needle used. The final cytological diagnosis was made using a standard Papanicolaou stain. For each lesion, the cytologist assessed sample adequacy: cellularity (score 1 "poor", score 2 "good", score 3 "excellent"),[14] and bloodiness (score 1 "minimal", score 2 "moderate", score 3 "significant")[21] and the presence or absence of malignancy ("positive"/"negative"/"suspicious"/ inconclusive).

3.6. Follow up Lesions will be considered malignant in the following cases: positive cytological diagnosis, positive histological diagnosis and clinical or radiological progression in the next 6 months. In case of negative results in the cytological diagnosis absence of clinical worsening and radiologic progression at least in the following 6 months after FNA will be required.

3.7. Data collection Clinical data will be prospectively collected and saved in a database including: demographic information (age and gender), size and location of the target lesion (pancreas, lymph node, liver, adrenal gland, others) and technical and procedure variables: FNA path (esophagus, stomach, duodenum), number of needle passes, needle visibility, ease to puncture, needle failure, cellularity, bloodiness, cytological diagnosis, final diagnosis, immediate complications.

  1. Statistical analysis Results for continuous variables will be expressed as means and standard deviations. Categorical variables will be expressed as frequencies and percentages. Chi-square test will be used to compare proportions. Continuous variables will be compared using Student´s t test. A two-tailed P values of less than 0.05 will be considered statistically significant. Data were analyzed with the Statistical Package for Social Sciences v. 15.0 (SPSS Inc., Chicago, IL, USA). The diagnostic yield of 15 G and 22 G needle will be evaluated by four criteria: sensitivity, specificity, positive predictive value and negative predictive value.

Sample size An expected rate of diagnostic yield from EUS guided FNA by using 22G needle of 85% will be considered. By using a power of 80% and an α value of 0.05 would be necessary 120 patients per group to detect a 15% difference in the rate of diagnostic yield.

Conditions
Solid Neoplasms
Being tested
Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific)
Keywords
endoscopic ultrasonography, fine needle aspiration cytology, 22 gauge, 25 gauge

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific)Device

    Also called Cook Medical, Boston Scientific

    Patients will be randomized either to receive EUS-FNA with a 22 g needle or 25 g needle. EUS-FNA passes will be performed without stylet until sample adequacy or until a maximum of 5 FNA passes in pancreatic lesions or 3 FNA passes in other lesions. In case of inadequate sample after 3 passes, or needle failure, cross over to the other type of needle is allowed.

Study groups in NCT01543282
Study groupRoleWhat they receive
EUS 22 gauge needleActive comparatorEUS 22 g needle is the most common needle used in clinical practice. EUS-FNA passes will be performed without stylet until sample adequacy or until a maximum of 5 FNA passes in pancreatic lesions or 3 FNA passes in other lesions. In case of inadequate sample after 3 passes, or needle failure, cross over to the other type of needle is allowed.
Receives: Device: Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific)
EUS 25 gauge needleExperimental25 gauge needle is usually used less frequently but nowadays is increasingly used and is as well a valid option. EUS-FNA passes will be performed without stylet until sample adequacy or until a maximum of 5 FNA passes in pancreatic lesions or 3 FNA passes in other lesions. In case of inadequate sample after 3 passes, or needle failure, cross over to the other type of needle is allowed.
Receives: Device: Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of stylet-free, solid lesion EUS-FNA using the 22 G FNA vs the 25 G FNA needle, in consecutive patients referred to EUS-FNA.

    Measured: 6 months

Secondary outcomes (1)
  1. Specimen adequacy, number of FNA passes, ease of puncture, failure of the FNA needle and complications

    Measured: 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted2 Mar 2012 (estimated)
  2. Study start10 Dec 2011
  3. Primary completionJul 2017
  4. Study completionJul 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Crossover
Masking
Single blind
Who is masked
Participant
Enrolment
120 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01543282
Sponsor's protocol ID
CE 11.150
Status last verified
May 2020
First submitted
15 Dec 2011
Last updated
22 May 2020
Results posted
No
Data monitoring committee
Yes

Publications

  • Yusuf TE, Ho S, Pavey DA, Michael H, Gress FG. Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience. Endoscopy. 2009 May;41(5):445-8. doi: 10.1055/s-0029-1214643. Epub 2009 May 5.

    PubMed 19418399
  • Imazu H, Uchiyama Y, Kakutani H, Ikeda K, Sumiyama K, Kaise M, Omar S, Ang TL, Tajiri H. A prospective comparison of EUS-guided FNA using 25-gauge and 22-gauge needles. Gastroenterol Res Pract. 2009;2009:546390. doi: 10.1155/2009/546390. Epub 2009 Nov 17.

    PubMed 19997511
  • Lee JH, Stewart J, Ross WA, Anandasabapathy S, Xiao L, Staerkel G. Blinded prospective comparison of the performance of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of the pancreas and peri-pancreatic lesions. Dig Dis Sci. 2009 Oct;54(10):2274-81. doi: 10.1007/s10620-009-0906-1. Epub 2009 Aug 11.

    PubMed 19669880
  • Sakamoto H, Kitano M, Komaki T, Noda K, Chikugo T, Dote K, Takeyama Y, Das K, Yamao K, Kudo M. Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge Trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses. J Gastroenterol Hepatol. 2009 Mar;24(3):384-90. doi: 10.1111/j.1440-1746.2008.05636.x. Epub 2008 Nov 20.

    PubMed 19032453
  • Camellini L, Carlinfante G, Azzolini F, Iori V, Cavina M, Sereni G, Decembrino F, Gallo C, Tamagnini I, Valli R, Piana S, Campari C, Gardini G, Sassatelli R. A randomized clinical trial comparing 22G and 25G needles in endoscopic ultrasound-guided fine-needle aspiration of solid lesions. Endoscopy. 2011 Aug;43(8):709-15. doi: 10.1055/s-0030-1256482. Epub 2011 May 24.

    PubMed 21611946
  • Fabbri C, Polifemo AM, Luigiano C, Cennamo V, Baccarini P, Collina G, Fornelli A, Macchia S, Zanini N, Jovine E, Fiscaletti M, Alibrandi A, D'Imperio N. Endoscopic ultrasound-guided fine needle aspiration with 22- and 25-gauge needles in solid pancreatic masses: a prospective comparative study with randomisation of needle sequence. Dig Liver Dis. 2011 Aug;43(8):647-52. doi: 10.1016/j.dld.2011.04.005. Epub 2011 May 17.

    PubMed 21592873
  • Wani S, Gupta N, Gaddam S, Singh V, Ulusarac O, Romanas M, Bansal A, Sharma P, Olyaee MS, Rastogi A. A comparative study of endoscopic ultrasound guided fine needle aspiration with and without a stylet. Dig Dis Sci. 2011 Aug;56(8):2409-14. doi: 10.1007/s10620-011-1608-z. Epub 2011 Feb 17.

    PubMed 21327919

Questions about this trial

What is this clinical trial studying?

A study testing Endosonography guided fine needle aspiration cytology ( Cook Medical, Boston Scientific) in people with Solid Neoplasms, run by Centre hospitalier de l'Université de Montréal (CHUM) at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 22 May 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy of stylet-free, solid lesion EUS-FNA using the 22 G FNA vs the 25 G FNA needle, in consecutive patients referred to EUS-FNA. (time frame: 6 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01543282, which also lists 7 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 May 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in