AzTrials
AzTrials

Living-Donor Kidney TransplantsNCT01545713

Correlation of Donor-specific Anti-endothelial Cells

An observational study of Living-Donor Kidney Transplants, run by Northwestern University at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Antibody Mediated Rejection (AMR) is a major complication of solid organ transplantation. The main reason for AMR is pre-formed, or de-novo, donor specific antibodies against the donor human leukocyte antigens (HLA). Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Living-Donor Kidney Transplants
How many people
16 participants
Where
1 siteUnited States
Study dates
Jun 2011to Dec 2017
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Living-Donor kidney transplant recipients at Northwestern Memorial Hospital 18 year of age or older.

Who may be able to join

  • patients older than 18 years of age
  • patients undergoing living-donor kidney transplant at NMH who have a positive XM-One AbSorber® positive test result

Who cannot join

  • patients undergoing deceased donor kidney transplant
  • patients younger than 18 years of age

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Northwestern Memorial Hospital

    Chicago, Illinois, 60611

Other trials in United States

About this study

Official title: A Phase II, Prospective, Single-center Study: Correlation of Donor-specific Anti-precursor Endothelial Cells With Transplant Outcome for Recipients of Living-donor Kidney Transplants, Are Auto-antibodies Important.

Antibody Mediated Rejection (AMR) is a major complication of solid organ transplantation. The main reason for AMR is pre-formed, or de-novo, donor specific antibodies against the donor human leukocyte antigens (HLA). Additional potential targets are antibodies against MIC-A antigens or antibodies against targets expressed on the donor endothelial cells.

Until recently, no specific means were available to test for the presence of donor-specific endothelial cell antibodies. The newly introduced XM-One AbSorber® assay allows isolating precursor endothelial cells from donor peripheral blood, and thus assessing the presence of donor-specific endothelial cell antibodies.

Read more

XM-One AbSorber® is an in-vitro assay that allows for the specific enrichment of precursor endothelial cells which in turn promotes endothelial cells specific cross match testing.

This assay is currently being used in an on-going Northwestern University (NU) research study (STU#00029988). The preliminary results of this study indicate that indeed some of the patients test positive against their respective donors. One potential explanation for this observation, that was not previously entertained, is that the antibodies causing the positive cross match response are actually of autoimmune nature. In order to rule-out such a potential explanation the investigators would like to further test these patients by performing an autologous XM-One AbSorber® assay in which the recipient sera will be incubated with the patients' own cells (as opposed to the respective donor cells in the parental study). This information is crucial for proper analysis of the data obtained in the NU STU#00029988 study.

Read the detailed description

Antibody Mediated Rejection (AMR) is a major complication of solid organ transplantation. The main reason for AMR is pre-formed, or de-novo, donor specific antibodies against the donor HLA antigens. Additional potential targets are antibodies against MIC-A antigens or antibodies against targets expressed on the donor endothelial cells.

Until recently, no specific means were available to test for the presence of donor-specific endothelial cell antibodies. The newly introduced XM-One AbSorber® assay allows isolating precursor endothelial cells from donor peripheral blood, and thus assessing the presence of donor-specific endothelial cell antibodies.

XM-One AbSorber® is an in-vitro assay that allows for the specific enrichment of precursor endothelial cells which in turn promotes endothelial cells specific cross match testing.

This assay is currently being used in an on-going Northwestern University (NU) research study (STU#00029988). The preliminary results of this study indicate that indeed some of the patients test positive against their respective donors. One potential explanation for this observation, that was not previously entertained, is that the antibodies causing the positive cross match response are actually of autoimmune nature. In order to rule-out such a potential explanation we would like to further test these patients by performing an autologous XM-One AbSorber® assay in which the recipient sera will be incubated with the patients' own cells (as opposed to the respective donor cells in the parental study). This information is crucial for proper analysis of the data obtained in the NU STU#00029988 study.

Initial data from our laboratory indicates that the antigens identified by the XM-One Absorber® assay differ from the HLA antigens usually identified by routine cross match assays. Moreover, we were able to document that this is a polymorphic system and therefore identifying a donor-specific source is critical.

Of the 150 patients already studied under NU research protocol STU#00029988 we found that 19 patients exhibited a positive response in a donor-specific XM-One AbSorber® assay. In this current research protocol study we want to follow-up on the specimens that exhibited a positive response in a donor-specific XM-One AbSorber® assay and perform an autologous XM-One AbSorber® assay to validate the clinical significance of our results.

There has been one multicenter study reported indicating the "XM-One AbSorber® is a quick, easy to perform on whole blood samples and identifies patients at risk for rejection and reduced graft function not identified by conventional lymphocyte cross matches" The primary objective is to complete additional testing for accuracy to determine whether antibodies directed at donor-specific endothelial cell effect transplant outcome.

The secondary objective is to assess the frequency of autologous antibodies that may be falsely reported as donor-specific anti-endothelial antibodies in our patient population. The single center research study we here at Northwestern University have been working on since May 19, 2010 thus far has resulted in 19 out of 150 specimens tested, have positive results based on the XM-One AbSorber® assay.

In this prospective study we plan to include all XM-One AbSorber® positive test results from all recipients of living-donor kidney transplants performed at Northwestern Memorial Hospital (NMH) since May 19, 2010 initial Institutional Review Board (IRB) approval until 250 transplants are performed. For this research protocol we will be targeting patients to consent only these individuals who have received a XM-One AbSorber® positive test result.

Each donor / recipient pair are required to send peripheral blood samples to the HLA laboratory prior to the scheduled transplant in order to perform lymphocyte cross match (to detect donor specific HLA antibodies; this is (SOC) standard of care). Left over serum and cells from these tests are being used to isolate an enriched precursor endothelial cell population and perform the XM-One AbSorber® assay (NU research protocol #STU00029988).

XM-One AbSorber® assay results - both autologous and allogeneic - will be captured and compared with graft outcome measurements at 3, 6, and 12 months post-transplant. Transplant outcome will be recorded as creatinine levels at the specific time points, protocol and for-cause biopsy results within the first year post transplant, diagnosis of acute cellular or humoral rejection, variation in immunosuppression levels, and any other complications.

Patients that exhibit a positive XM-One AbSorber® allogeneic cross match result will be requested to donate 4 green top tubes of peripheral blood. Cells obtained from this blood will be used in an autologous XM-One AbSorber® cross match assay using the original serum sample used for the allogeneic XM-One AbSorber® cross match assay.

Keywords
renal, kidney, transplant, living donor

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

Study groups in NCT01545713
Study groupRoleWhat they receive
Renal Transplant RecipientsPatients undergoing living-donor kidney transplant at NMH who have a positive XM-One AbSorber® positive test result.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. To complete additional testing for accuracy

    The primary objective is to complete additional testing for accuracy to determine whether antibodies directed at donor-specific endothelial cell effect transplant outcome.

    Measured: June 2011 - February 2012

Secondary outcomes (1)
  1. To assess the frequency of autologous antibodies.

    To assess the frequency of autologous antibodies that may be falsely reported as donor-specific anti-endothelial antibodies in our patient population. The single center research study we here at Northwestern University have been working on since May 19, 2010 thus far has resulted in 19 out of 150 specimens tested, have positive results based on the XM-One AbSorber® assay.

    Measured: June 2011 - February 2012

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Mar 2012 (estimated)
  2. Study startJun 2011
  3. Primary completionFeb 2012
  4. Study completionDec 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Prospective
Enrolment
16 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01545713
Sponsor's protocol ID
XM-One AbSorber
Status last verified
Aug 2018
First submitted
1 Mar 2012
Last updated
23 Aug 2018
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

An observational study of Living-Donor Kidney Transplants, run by Northwestern University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 23 Aug 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

To complete additional testing for accuracy (time frame: June 2011 - February 2012). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Aug 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in