Living-Donor Kidney TransplantsNCT01545713
Correlation of Donor-specific Anti-endothelial Cells
An observational study of Living-Donor Kidney Transplants, run by Northwestern University at 1 site in United States.
Trial summary
Antibody Mediated Rejection (AMR) is a major complication of solid organ transplantation. The main reason for AMR is pre-formed, or de-novo, donor specific antibodies against the donor human leukocyte antigens (HLA). Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Living-Donor Kidney Transplants
- How many people
- 16 participants
- Where
- 1 siteUnited States
- Study dates
- Jun 2011to Dec 2017
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Living-Donor kidney transplant recipients at Northwestern Memorial Hospital 18 year of age or older.
Who may be able to join
- patients older than 18 years of age
- patients undergoing living-donor kidney transplant at NMH who have a positive XM-One AbSorber® positive test result
Who cannot join
- patients undergoing deceased donor kidney transplant
- patients younger than 18 years of age
Trial locations and contacts
1 site in 1 country.
United States1 site
Northwestern Memorial Hospital
Chicago, Illinois, 60611
About this study
Official title: A Phase II, Prospective, Single-center Study: Correlation of Donor-specific Anti-precursor Endothelial Cells With Transplant Outcome for Recipients of Living-donor Kidney Transplants, Are Auto-antibodies Important.
Antibody Mediated Rejection (AMR) is a major complication of solid organ transplantation. The main reason for AMR is pre-formed, or de-novo, donor specific antibodies against the donor human leukocyte antigens (HLA). Additional potential targets are antibodies against MIC-A antigens or antibodies against targets expressed on the donor endothelial cells.
Until recently, no specific means were available to test for the presence of donor-specific endothelial cell antibodies. The newly introduced XM-One AbSorber® assay allows isolating precursor endothelial cells from donor peripheral blood, and thus assessing the presence of donor-specific endothelial cell antibodies.
Read more
XM-One AbSorber® is an in-vitro assay that allows for the specific enrichment of precursor endothelial cells which in turn promotes endothelial cells specific cross match testing.
This assay is currently being used in an on-going Northwestern University (NU) research study (STU#00029988). The preliminary results of this study indicate that indeed some of the patients test positive against their respective donors. One potential explanation for this observation, that was not previously entertained, is that the antibodies causing the positive cross match response are actually of autoimmune nature. In order to rule-out such a potential explanation the investigators would like to further test these patients by performing an autologous XM-One AbSorber® assay in which the recipient sera will be incubated with the patients' own cells (as opposed to the respective donor cells in the parental study). This information is crucial for proper analysis of the data obtained in the NU STU#00029988 study.
Read the detailed description
Antibody Mediated Rejection (AMR) is a major complication of solid organ transplantation. The main reason for AMR is pre-formed, or de-novo, donor specific antibodies against the donor HLA antigens. Additional potential targets are antibodies against MIC-A antigens or antibodies against targets expressed on the donor endothelial cells.
Until recently, no specific means were available to test for the presence of donor-specific endothelial cell antibodies. The newly introduced XM-One AbSorber® assay allows isolating precursor endothelial cells from donor peripheral blood, and thus assessing the presence of donor-specific endothelial cell antibodies.
XM-One AbSorber® is an in-vitro assay that allows for the specific enrichment of precursor endothelial cells which in turn promotes endothelial cells specific cross match testing.
This assay is currently being used in an on-going Northwestern University (NU) research study (STU#00029988). The preliminary results of this study indicate that indeed some of the patients test positive against their respective donors. One potential explanation for this observation, that was not previously entertained, is that the antibodies causing the positive cross match response are actually of autoimmune nature. In order to rule-out such a potential explanation we would like to further test these patients by performing an autologous XM-One AbSorber® assay in which the recipient sera will be incubated with the patients' own cells (as opposed to the respective donor cells in the parental study). This information is crucial for proper analysis of the data obtained in the NU STU#00029988 study.
Initial data from our laboratory indicates that the antigens identified by the XM-One Absorber® assay differ from the HLA antigens usually identified by routine cross match assays. Moreover, we were able to document that this is a polymorphic system and therefore identifying a donor-specific source is critical.
Of the 150 patients already studied under NU research protocol STU#00029988 we found that 19 patients exhibited a positive response in a donor-specific XM-One AbSorber® assay. In this current research protocol study we want to follow-up on the specimens that exhibited a positive response in a donor-specific XM-One AbSorber® assay and perform an autologous XM-One AbSorber® assay to validate the clinical significance of our results.
There has been one multicenter study reported indicating the "XM-One AbSorber® is a quick, easy to perform on whole blood samples and identifies patients at risk for rejection and reduced graft function not identified by conventional lymphocyte cross matches" The primary objective is to complete additional testing for accuracy to determine whether antibodies directed at donor-specific endothelial cell effect transplant outcome.
The secondary objective is to assess the frequency of autologous antibodies that may be falsely reported as donor-specific anti-endothelial antibodies in our patient population. The single center research study we here at Northwestern University have been working on since May 19, 2010 thus far has resulted in 19 out of 150 specimens tested, have positive results based on the XM-One AbSorber® assay.
In this prospective study we plan to include all XM-One AbSorber® positive test results from all recipients of living-donor kidney transplants performed at Northwestern Memorial Hospital (NMH) since May 19, 2010 initial Institutional Review Board (IRB) approval until 250 transplants are performed. For this research protocol we will be targeting patients to consent only these individuals who have received a XM-One AbSorber® positive test result.
Each donor / recipient pair are required to send peripheral blood samples to the HLA laboratory prior to the scheduled transplant in order to perform lymphocyte cross match (to detect donor specific HLA antibodies; this is (SOC) standard of care). Left over serum and cells from these tests are being used to isolate an enriched precursor endothelial cell population and perform the XM-One AbSorber® assay (NU research protocol #STU00029988).
XM-One AbSorber® assay results - both autologous and allogeneic - will be captured and compared with graft outcome measurements at 3, 6, and 12 months post-transplant. Transplant outcome will be recorded as creatinine levels at the specific time points, protocol and for-cause biopsy results within the first year post transplant, diagnosis of acute cellular or humoral rejection, variation in immunosuppression levels, and any other complications.
Patients that exhibit a positive XM-One AbSorber® allogeneic cross match result will be requested to donate 4 green top tubes of peripheral blood. Cells obtained from this blood will be used in an autologous XM-One AbSorber® cross match assay using the original serum sample used for the allogeneic XM-One AbSorber® cross match assay.
- Conditions
- Living-Donor Kidney Transplants
- Keywords
- renal, kidney, transplant, living donor
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
| Study group | Role | What they receive |
|---|---|---|
| Renal Transplant Recipients | Patients undergoing living-donor kidney transplant at NMH who have a positive XM-One AbSorber® positive test result. |
What is being measured
The primary outcome is the main question the study is designed to answer.
To complete additional testing for accuracy
The primary objective is to complete additional testing for accuracy to determine whether antibodies directed at donor-specific endothelial cell effect transplant outcome.
Measured: June 2011 - February 2012
Secondary outcomes (1)
To assess the frequency of autologous antibodies.
To assess the frequency of autologous antibodies that may be falsely reported as donor-specific anti-endothelial antibodies in our patient population. The single center research study we here at Northwestern University have been working on since May 19, 2010 thus far has resulted in 19 out of 150 specimens tested, have positive results based on the XM-One AbSorber® assay.
Measured: June 2011 - February 2012
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted7 Mar 2012 (estimated)
- Study startJun 2011
- Primary completionFeb 2012
- Study completionDec 2017
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Living-Donor Kidney TransplantsStudies of the same condition, open and under way.
- More trials run by Northwestern UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Prospective
- Enrolment
- 16 participants (actual)
Sponsor and investigators
- Lead sponsor
- Northwestern University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, John Friedewald, Northwestern University
- Investigators
- John Friedewald, MD, Principal investigator, Northwestern University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01545713
- Sponsor's protocol ID
- XM-One AbSorber
- Status last verified
- Aug 2018
- First submitted
- 1 Mar 2012
- Last updated
- 23 Aug 2018
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 23 Aug 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Phase II, Prospective, Single-center Study: Correlation of Donor-specific Anti-precursor Endothelial Cells With Transplant Outcome for Recipients of Living-donor Kidney Transplants, Are Auto-antibodies Important.
- ClinicalTrials.gov ID
- NCT01545713
- Acronym / sponsor ID
- XM-One AbSorber
- Conditions
- Living-Donor Kidney Transplants
- Keywords
- renal, kidney, transplant, living donor
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 16 participants (actual)
- Lead sponsor
- Northwestern UniversityUniversity, hospital or other
- Study start
- Jun 2011 (actual)
- Primary completion
- Feb 2012 (actual)
- Study completion
- Dec 2017 (actual)
- First posted
- 7 Mar 2012 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Antibody Mediated Rejection (AMR) is a major complication of solid organ transplantation. The main reason for AMR is pre-formed, or de-novo, donor specific antibodies against the donor human leukocyte antigens (HLA). Additional potential targets are antibodies against MIC-A antigens or antibodies against targets expressed on the donor endothelial cells.
Until recently, no specific means were available to test for the presence of donor-specific endothelial cell antibodies. The newly introduced XM-One AbSorber® assay allows isolating precursor endothelial cells from donor peripheral blood, and thus assessing the presence of donor-specific endothelial cell antibodies.
XM-One AbSorber® is an in-vitro assay that allows for the specific enrichment of precursor endothelial cells which in turn promotes endothelial cells specific cross match testing.
This assay is currently being used in an on-going Northwestern University (NU) research study (STU#00029988). The preliminary results of this study indicate that indeed some of the patients test positive against their respective donors. One potential explanation for this observation, that was not previously entertained, is that the antibodies causing the positive cross match response are actually of autoimmune nature. In order to rule-out such a potential explanation the investigators would like to further test these patients by performing an autologous XM-One AbSorber® assay in which the recipient sera will be incubated with the patients' own cells (as opposed to the respective donor cells in the parental study). This information is crucial for proper analysis of the data obtained in the NU STU#00029988 study.
Detailed description
Antibody Mediated Rejection (AMR) is a major complication of solid organ transplantation. The main reason for AMR is pre-formed, or de-novo, donor specific antibodies against the donor HLA antigens. Additional potential targets are antibodies against MIC-A antigens or antibodies against targets expressed on the donor endothelial cells.
Until recently, no specific means were available to test for the presence of donor-specific endothelial cell antibodies. The newly introduced XM-One AbSorber® assay allows isolating precursor endothelial cells from donor peripheral blood, and thus assessing the presence of donor-specific endothelial cell antibodies.
XM-One AbSorber® is an in-vitro assay that allows for the specific enrichment of precursor endothelial cells which in turn promotes endothelial cells specific cross match testing.
This assay is currently being used in an on-going Northwestern University (NU) research study (STU#00029988). The preliminary results of this study indicate that indeed some of the patients test positive against their respective donors. One potential explanation for this observation, that was not previously entertained, is that the antibodies causing the positive cross match response are actually of autoimmune nature. In order to rule-out such a potential explanation we would like to further test these patients by performing an autologous XM-One AbSorber® assay in which the recipient sera will be incubated with the patients' own cells (as opposed to the respective donor cells in the parental study). This information is crucial for proper analysis of the data obtained in the NU STU#00029988 study.
Initial data from our laboratory indicates that the antigens identified by the XM-One Absorber® assay differ from the HLA antigens usually identified by routine cross match assays. Moreover, we were able to document that this is a polymorphic system and therefore identifying a donor-specific source is critical.
Of the 150 patients already studied under NU research protocol STU#00029988 we found that 19 patients exhibited a positive response in a donor-specific XM-One AbSorber® assay. In this current research protocol study we want to follow-up on the specimens that exhibited a positive response in a donor-specific XM-One AbSorber® assay and perform an autologous XM-One AbSorber® assay to validate the clinical significance of our results.
There has been one multicenter study reported indicating the "XM-One AbSorber® is a quick, easy to perform on whole blood samples and identifies patients at risk for rejection and reduced graft function not identified by conventional lymphocyte cross matches" The primary objective is to complete additional testing for accuracy to determine whether antibodies directed at donor-specific endothelial cell effect transplant outcome.
The secondary objective is to assess the frequency of autologous antibodies that may be falsely reported as donor-specific anti-endothelial antibodies in our patient population. The single center research study we here at Northwestern University have been working on since May 19, 2010 thus far has resulted in 19 out of 150 specimens tested, have positive results based on the XM-One AbSorber® assay.
In this prospective study we plan to include all XM-One AbSorber® positive test results from all recipients of living-donor kidney transplants performed at Northwestern Memorial Hospital (NMH) since May 19, 2010 initial Institutional Review Board (IRB) approval until 250 transplants are performed. For this research protocol we will be targeting patients to consent only these individuals who have received a XM-One AbSorber® positive test result.
Each donor / recipient pair are required to send peripheral blood samples to the HLA laboratory prior to the scheduled transplant in order to perform lymphocyte cross match (to detect donor specific HLA antibodies; this is (SOC) standard of care). Left over serum and cells from these tests are being used to isolate an enriched precursor endothelial cell population and perform the XM-One AbSorber® assay (NU research protocol #STU00029988).
XM-One AbSorber® assay results - both autologous and allogeneic - will be captured and compared with graft outcome measurements at 3, 6, and 12 months post-transplant. Transplant outcome will be recorded as creatinine levels at the specific time points, protocol and for-cause biopsy results within the first year post transplant, diagnosis of acute cellular or humoral rejection, variation in immunosuppression levels, and any other complications.
Patients that exhibit a positive XM-One AbSorber® allogeneic cross match result will be requested to donate 4 green top tubes of peripheral blood. Cells obtained from this blood will be used in an autologous XM-One AbSorber® cross match assay using the original serum sample used for the allogeneic XM-One AbSorber® cross match assay.
Study design
- Observational model
- Case only
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Renal Transplant Recipients | – | –Patients undergoing living-donor kidney transplant at NMH who have a positive XM-One AbSorber® positive test result. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Living-Donor kidney transplant recipients at Northwestern Memorial Hospital 18 year of age or older.
Key inclusion criteria (2 listed)
- patients older than 18 years of age
- patients undergoing living-donor kidney transplant at NMH who have a positive XM-One AbSorber® positive test result
Key exclusion criteria (2 listed)
- patients undergoing deceased donor kidney transplant
- patients younger than 18 years of age
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
To complete additional testing for accuracy
Time frame: June 2011 - February 2012
The primary objective is to complete additional testing for accuracy to determine whether antibodies directed at donor-specific endothelial cell effect transplant outcome.
1 secondary outcome
To assess the frequency of autologous antibodies.
Time frame: June 2011 - February 2012
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 23 Aug 2018.
Related trials for Living-Donor Kidney Transplants
Not yet recruitingPhase 1
ECP-DL Cell Infusion for Induction in Living Donor Kidney (LDK) Transplants
Kidney Transplant Failure and Rejection, Kidney Transplant; Complications
Not yet recruiting
Technology-enabled Social Network Intervention to Increase Live Donor Kidney Transplantation
End-Stage Renal Disease, Chronic Kidney Diseases
Active, not recruitingPhase 1/2
Cell Therapy for Immunomodulation in Kidney Transplantation
Kidney Transplantation
Active, not recruiting
Strategies to Transform Kidney Care and Improve Pursuit of Transplant
Kidney Disease, Kidney Transplant
Active, not recruitingObservational study
Transforming Curiosity Into Donation
Kidney Transplant, Kidney Donor
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
John Friedewald, MD principal investigator
Northwestern University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Living-Donor Kidney Transplants, run by Northwestern University at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 23 Aug 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
To complete additional testing for accuracy (time frame: June 2011 - February 2012). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Aug 2018.