Other Obstetric Trauma - DeliveredPhase 2SDBNCT01566331
Safe Delivery Using a Belt on the Belly of Pregnant Woman
A Phase 2 study testing Baby-guardTM in people with Other Obstetric Trauma - Delivered, run by University of Padova at 1 site in Italy.
Trial summary
Safety of natural, vaginal labor for parturient, fetus and newborn is one of most important goal among obstetricians, midwifes, scientific society all over the world. Maternal and newborn clinical problems and complications following vaginal delivery cause a big amount of medico-legal problems and high costs in the… Read more about this study
- Who is it for?
- Ages 23 to 42 years, women onlyHealthy volunteers can take part
- Conditions the study is for
- Other Obstetric Trauma - Delivered
- What is being tested?
- Baby-guardTM
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 80 participants
- Where
- 1 siteItaly
- Study dates
- Jan 2011to Mar 2011
- Phase
- Phase 2
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 23 to 42 years
- Women only
- Healthy volunteers accepted
- Adult
Who may be able to join
- women in active labor at term in primipara with maternal age ranging from 23 to 42 years, with a singleton fetus in vertex presentation.
- the onset of second stage was defined as full dilatation of the cervix identified by digital examination
Who cannot join
- preterm labor (gestational age below 37 weeks)
- breech or transverse presentation
- suspected fetal macrosomia
- gestational diabetes
- pregnancy-induced hypertension
- abnormalities of placentation (low lying placenta, abruptio placenta)
Show all 9Show fewer
- uterine structural abnormalities
- history of previous uterine scar
- fetal heart rate abnormalities at the time of enrollment (bradycardia, tachycardia or prolonged variable decelerations).
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Safe Natural Delivery by Using a New Inflatable Ergonomic Three Chambers Belt
Safety of natural, vaginal labor for parturient, fetus and newborn is one of most important goal among obstetricians, midwifes, scientific society all over the world. Maternal and newborn clinical problems and complications following vaginal delivery cause a big amount of medico-legal problems and high costs in the sanitary field.
Among the maneuvers that are used in the second stage of labor, uterine fundal pressure is one of the most controversial and often diffuse in all over the world, generally not documented, or under reported in medical records . Many Authors affirms that a different new way to push may be of help. This maneuver was introduced by Kristeller, that in 1867 minutely described a procedure to shorten, through the application of a pressure on the uterine fundus whose intensity was quantified by a dynamometer and the duration measured in seconds, the length of the second phase of the labor. Although uterine fundal pressure maneuver was described by Kristeller as the placement of two hands on the uterine fundus and the consequential application of longitudinal steady pressure at a 30- to 45-degree angle directed toward the pelvis, with the avoidance of direct pressure toward the maternal spine, there is no clear definition of the maneuver and no indication for its use has been formally described to date.
The aim of this study was therefore to assess whether the use of the Baby-guardTM system, through its ergonomic, three chamber, inflatable abdominal belt, engineered after studies of biomechanics and biophysics, that follows obstetric semiotics, that applies fundal pressure during the second stage of labor in the direction of the pelvic outlet, may be of maternal and fetus aid for a safe natural childbirth for their better outcomes.
Read the detailed description
A randomized, single blind, controlled, prospective study was performed. Subjects were nulliparous women who delivered at a community setting hospital (U.O.C. Obstetrics and Gynecology, "San Giuseppe" Hospital, Empoli, Italy) between January 24, 2011 and March 24, 2011. Vaginal deliveries were eligible. Patients were therefore divided into two groups by randomly numbered envelopes upon full dilatation of the cervix, and allocated to the following two groups:
- The Study Group (n=40 patients) in whom the inflatable belt was applied with the correct pressures (ranging from 80 to 150 mm/Hg, see below the description of the protocol)during Labor and Delivery
- The Control Group (n=40 women), in whom the belt was inflated with minimal pressures (from 10 to 20 mm/Hg) During Labor and Delivery To test whether differences between experimental groups are statistically significant, the sample-size should be calculated "a priori". To do this, a primary end-point has been identified: incidence of perineal-cervical lacerations. The sample-size (n > 62 subjects for two groups) will be obtained using STATA program by a two-tailed test [alpha level of 0.05 and 90% of statistical power (1-Beta)], to detect statistically significant reduction from 50% to 10% or less with respect the primary end-point. Therefore a randomized sample size of 40 pregnant women per group was chosen to allow for possible refusals or withdrawals.
Data collected from delivery records, retrospectively obtained and reviewed, will include: patient's age, race, parity, patient's body mass index (BMI, kg/m2) at the time of delivery, and body weight change during pregnancy (defined as the difference between maternal pre-pregnant body weight and body weight at delivery), as part of the ante-partum information. For the intra-partum information, gestational age at delivery, duration of second phase of labor, use of intravenous oxytocin, episiotomy, cervical laceration (as requiring surgical repair for hemostasis), severe perineal lacerations (defined as third- or fourth- laceration, while mild perineal laceration was defend as first- or second- perineal laceration), vacuum extraction, forceps delivery, use of uterine fundal pressure maneuver were abstracted. All The study Group will followed up for 15 days after delivery Fetal weight was estimated by the combination of biparietal diameter, abdominal circumference and femur length. The mean percent difference between the predicted and actual weight was 9.6% corresponding to a mean overestimation of 294 g or underestimation of 314 g. These values are consistent with most reports in the literature.
The study will be performed according to the guidelines of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH); the declaration of Helsinki regarding the Standard operating procedures for clinical investigators (GCP); the General requirements for Clinical investigation of medical devices for human subjects. Finally, the local ethical committee approved the study protocol, and all patients received detailed information about the study and the procedure, to which they gave their written consent.
The inflatable belt (Baby-guardTM ) and study protocol The Baby-guardTM (CABEL s.a.s. Costruzioni Elettroniche, Pistoia, Italy) consists of a disposable, ergonomic, three chambers, inflatable belt, and a detector of electro-physiological signals from maternal abdomen (i.e. fetal heart and maternal heart signals - Figure 1). myographic uterine activity). Three chambers that can be separately swollen one from the other in order to repositioning fetal body compose the inflatable belt. The three belt chambers are filled according to the pressures set by the operator (midwife/MD) and allow to gently positioning of the fetus in the wright position towards the pelvis. Once the correct fetal position has been obtained, all three chambers are inflated in synchronously with uterine contraction. The maternal and fetal monitoring unit is composed by a touch-screen computer, that records electro-physiological signals collected by a signal amplifier deriving from the mother (uterine contractions and the maternal heart rate) and the fetus (fetal heart rate and the possibility of Doppler parameters of fetal heart). All parameters and signals detected by the Baby-guardTM system are storable on the touch-screen computer hard disk, as per request of the European Community rules on safety (UNI EN60601)].
This study reports only the part regarding results and outcomes of parturient and neonates.
At the beginning of the uterine contraction, as referred by the patients and revealed by the electro-physiological signals recorded, the midwife/MD, if necessary, inflated 30-50 mmHg of air pressure into the lateral chambers of the inflatable belt to correctly align the fetus avoiding his malpositioning with respect to the pelvis. After monitoring the duration of spontaneous uterine contractions, the midwife/MD therefore inflated from 80 to 150 mm/Hg (for the Study Group) or from 10 to 20 mm/Hg (for the Control Group) of air into the ergonomic belt for 30 sec. Fundal pressure was applied at a 30-40° angle to the spine in the direction of the pelvic outlet through the inflatable belt, standardizing the force and surface area of application (980 cm2). The frequency of inflation was limited to fewer than 6 times per 20 min. followed by a pause of 10 min. All the women, whether randomized to the Study or the Control group, received standard management of the second stage of labor, which includes one-to-one support, fetal heart rate monitoring, and care from midwife. Operative deliveries were performed if clinically indicated. As a uterine contraction started, the inflatable obstetric belt was inflated synchronously and maintained at the pressure above indicated for 30 sec. by the midwife/MD. The Baby-guardTM was not used for more than 2 hours till delivery. The obstetrician, the midwife and the patients were blind to whether the belt was inflated with sufficient pressure (from 80 to 150 mm/Hg for the Study Group) or not (from 10 to 20 mm/Hg for the Control Group).
Outcomes of the study Outcome measures in this study were the perineal and cervical lacerations incidence, the use of uterine fundal pressure maneuver (Kristeller manouvre), the incidence of vacuum extractions, cesarean section incidence during labor, second stage of labor duration; maternal psychological and physical fatigue, maternal request of cesarean section during labor, and absence of neonatal intensive care unit admissions.
At the time of discharge to home, patients' satisfaction with the inflatable belt was evaluated asking them to score about the degree of psychological and physical fatigue with the Baby-guardTM by marking a 10-cm visual analogue scale (VAS) from 0 (minimal) to 10 (optimal). Patients were also asked about the usefulness of the inflatable belt assistance to delivery. The number of cesarean section requests during the second phase of labor was also evaluated.
Statistical analysis All data were analyzed with the STATA software (StataCorp LP, College Station, Texas, USA), and were expressed as mean ± SD (range) or as number (%) of cases. Comparisons of proportions and means between groups (study vs control) were done using the χ2 test (or Fisher exact test, if suitable) and, independent t-test, respectively.
- Conditions
- Other Obstetric Trauma - Delivered
- Being tested
- Baby-guardTM
- Keywords
- Safe Delivery, reduction of pain, reduction stage of labor
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Baby-guardTMDevice
Also called Safety baby guard
Baby-guardTM system, through its ergonomic, three chamber, inflatable abdominal belt, engineered after studies of biomechanics and biophysics, that follows obstetric semiotics, that applies fundal pressure during the second stage of labor in the direction of the pelvic outlet, may be of maternal and fetus aid for a safe natural childbirth for their better outcomes
| Study group | Role | What they receive |
|---|---|---|
| Baby-guardTM | Experimental | Baby-guardTM system, through its ergonomic, three chamber, inflatable abdominal belt, engineered after studies of biomechanics and biophysics, that follows obstetric semiotics, that applies fundal pressure during the second stage of labor in the direction of the pelvic outlet. Receives: Device: Baby-guardTM |
| no intervention | No intervention | Baby-guardTM system, without inflation |
What is being measured
The primary outcome is the main question the study is designed to answer.
Partecipant With Perineal Laceration
The following types of lacerations were recorded during delivery: cervical laceration; mild perineal lacerations (defined as 1-2 lacerations); severe perineal lacerations (defined as 3-4 lacerations)
Measured: after delivery
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted29 Mar 2012 (estimated)
- Study startJan 2011
- Primary completionMar 2011
- Study completionMar 2011
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (4)Papers the sponsor has linked to this study.
- Other trials for Other Obstetric Trauma - DeliveredStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 2
- Primary purpose
- Health services research
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Investigator
- Enrolment
- 80 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Padova
- Sponsor type
- University, hospital or other
- Collaborators
- University of Florence
- Responsible party
- Principal investigator, Erich Cosmi MD, PhD, University of Padova
- Investigators
- luisa Acanfora, MD, Study chair, University of Florence
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01566331
- Sponsor's protocol ID
- unipd
- Acronym
- SDB
- Status last verified
- Oct 2016
- First submitted
- 19 Mar 2012
- Last updated
- 12 Dec 2016
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
- Individual data sharing
- No
Publications
Hoogsteder PH, Pijnenborg JM. Use of uterine fundal pressure maneuver at vaginal delivery and risk of severe perineal laceration. Arch Gynecol Obstet. 2010 Mar;281(3):579-80. doi: 10.1007/s00404-009-1229-3. Epub 2009 Sep 23. No abstract available.
PubMed 19774390Cosner KR. Use of fundal pressure during second-stage labor. A pilot Study. J Nurse Midwifery. 1996 Jul-Aug;41(4):334-7. doi: 10.1016/0091-2182(96)00033-x.
PubMed 8828318Api O, Api M. Uterine fundal pressure and duration of the second stage of labor: A randomized controlled trial. Acta Obstet Gynecol Scand. 2009;88(11):1297-8. doi: 10.3109/00016340903214999. No abstract available.
PubMed 19900147Acanfora L, Rampon M, Filippeschi M, Marchi M, Montisci M, Viel G, Cosmi E. An inflatable ergonomic 3-chamber fundal pressure belt to assist vaginal delivery. Int J Gynaecol Obstet. 2013 Jan;120(1):78-81. doi: 10.1016/j.ijgo.2012.07.025. Epub 2012 Oct 16.
PubMed 23083494
Study at a glance
From the registry record, last updated by the sponsor on 12 Dec 2016. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Safe Natural Delivery by Using a New Inflatable Ergonomic Three Chambers Belt
- ClinicalTrials.gov ID
- NCT01566331
- Acronym / sponsor ID
- SDB / unipd
- Conditions
- Other Obstetric Trauma - Delivered
- Keywords
- Safe Delivery, reduction of pain, reduction stage of labor
- Phase
- Phase 2
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 80 participants (actual)
- Lead sponsor
- University of PadovaUniversity, hospital or other
- Collaborators
- University of Florence
- Study start
- Jan 2011
- Primary completion
- Mar 2011 (actual)
- Study completion
- Mar 2011 (actual)
- First posted
- 29 Mar 2012 (estimated)
- Results
- Posted 12 Dec 2016
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Safety of natural, vaginal labor for parturient, fetus and newborn is one of most important goal among obstetricians, midwifes, scientific society all over the world. Maternal and newborn clinical problems and complications following vaginal delivery cause a big amount of medico-legal problems and high costs in the sanitary field.
Among the maneuvers that are used in the second stage of labor, uterine fundal pressure is one of the most controversial and often diffuse in all over the world, generally not documented, or under reported in medical records . Many Authors affirms that a different new way to push may be of help. This maneuver was introduced by Kristeller, that in 1867 minutely described a procedure to shorten, through the application of a pressure on the uterine fundus whose intensity was quantified by a dynamometer and the duration measured in seconds, the length of the second phase of the labor. Although uterine fundal pressure maneuver was described by Kristeller as the placement of two hands on the uterine fundus and the consequential application of longitudinal steady pressure at a 30- to 45-degree angle directed toward the pelvis, with the avoidance of direct pressure toward the maternal spine, there is no clear definition of the maneuver and no indication for its use has been formally described to date.
The aim of this study was therefore to assess whether the use of the Baby-guardTM system, through its ergonomic, three chamber, inflatable abdominal belt, engineered after studies of biomechanics and biophysics, that follows obstetric semiotics, that applies fundal pressure during the second stage of labor in the direction of the pelvic outlet, may be of maternal and fetus aid for a safe natural childbirth for their better outcomes.
Detailed description
A randomized, single blind, controlled, prospective study was performed. Subjects were nulliparous women who delivered at a community setting hospital (U.O.C. Obstetrics and Gynecology, "San Giuseppe" Hospital, Empoli, Italy) between January 24, 2011 and March 24, 2011. Vaginal deliveries were eligible. Patients were therefore divided into two groups by randomly numbered envelopes upon full dilatation of the cervix, and allocated to the following two groups:
- The Study Group (n=40 patients) in whom the inflatable belt was applied with the correct pressures (ranging from 80 to 150 mm/Hg, see below the description of the protocol)during Labor and Delivery
- The Control Group (n=40 women), in whom the belt was inflated with minimal pressures (from 10 to 20 mm/Hg) During Labor and Delivery To test whether differences between experimental groups are statistically significant, the sample-size should be calculated "a priori". To do this, a primary end-point has been identified: incidence of perineal-cervical lacerations. The sample-size (n > 62 subjects for two groups) will be obtained using STATA program by a two-tailed test [alpha level of 0.05 and 90% of statistical power (1-Beta)], to detect statistically significant reduction from 50% to 10% or less with respect the primary end-point. Therefore a randomized sample size of 40 pregnant women per group was chosen to allow for possible refusals or withdrawals.
Data collected from delivery records, retrospectively obtained and reviewed, will include: patient's age, race, parity, patient's body mass index (BMI, kg/m2) at the time of delivery, and body weight change during pregnancy (defined as the difference between maternal pre-pregnant body weight and body weight at delivery), as part of the ante-partum information. For the intra-partum information, gestational age at delivery, duration of second phase of labor, use of intravenous oxytocin, episiotomy, cervical laceration (as requiring surgical repair for hemostasis), severe perineal lacerations (defined as third- or fourth- laceration, while mild perineal laceration was defend as first- or second- perineal laceration), vacuum extraction, forceps delivery, use of uterine fundal pressure maneuver were abstracted. All The study Group will followed up for 15 days after delivery Fetal weight was estimated by the combination of biparietal diameter, abdominal circumference and femur length. The mean percent difference between the predicted and actual weight was 9.6% corresponding to a mean overestimation of 294 g or underestimation of 314 g. These values are consistent with most reports in the literature.
The study will be performed according to the guidelines of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH); the declaration of Helsinki regarding the Standard operating procedures for clinical investigators (GCP); the General requirements for Clinical investigation of medical devices for human subjects. Finally, the local ethical committee approved the study protocol, and all patients received detailed information about the study and the procedure, to which they gave their written consent.
The inflatable belt (Baby-guardTM ) and study protocol The Baby-guardTM (CABEL s.a.s. Costruzioni Elettroniche, Pistoia, Italy) consists of a disposable, ergonomic, three chambers, inflatable belt, and a detector of electro-physiological signals from maternal abdomen (i.e. fetal heart and maternal heart signals - Figure 1). myographic uterine activity). Three chambers that can be separately swollen one from the other in order to repositioning fetal body compose the inflatable belt. The three belt chambers are filled according to the pressures set by the operator (midwife/MD) and allow to gently positioning of the fetus in the wright position towards the pelvis. Once the correct fetal position has been obtained, all three chambers are inflated in synchronously with uterine contraction. The maternal and fetal monitoring unit is composed by a touch-screen computer, that records electro-physiological signals collected by a signal amplifier deriving from the mother (uterine contractions and the maternal heart rate) and the fetus (fetal heart rate and the possibility of Doppler parameters of fetal heart). All parameters and signals detected by the Baby-guardTM system are storable on the touch-screen computer hard disk, as per request of the European Community rules on safety (UNI EN60601)].
This study reports only the part regarding results and outcomes of parturient and neonates.
At the beginning of the uterine contraction, as referred by the patients and revealed by the electro-physiological signals recorded, the midwife/MD, if necessary, inflated 30-50 mmHg of air pressure into the lateral chambers of the inflatable belt to correctly align the fetus avoiding his malpositioning with respect to the pelvis. After monitoring the duration of spontaneous uterine contractions, the midwife/MD therefore inflated from 80 to 150 mm/Hg (for the Study Group) or from 10 to 20 mm/Hg (for the Control Group) of air into the ergonomic belt for 30 sec. Fundal pressure was applied at a 30-40° angle to the spine in the direction of the pelvic outlet through the inflatable belt, standardizing the force and surface area of application (980 cm2). The frequency of inflation was limited to fewer than 6 times per 20 min. followed by a pause of 10 min. All the women, whether randomized to the Study or the Control group, received standard management of the second stage of labor, which includes one-to-one support, fetal heart rate monitoring, and care from midwife. Operative deliveries were performed if clinically indicated. As a uterine contraction started, the inflatable obstetric belt was inflated synchronously and maintained at the pressure above indicated for 30 sec. by the midwife/MD. The Baby-guardTM was not used for more than 2 hours till delivery. The obstetrician, the midwife and the patients were blind to whether the belt was inflated with sufficient pressure (from 80 to 150 mm/Hg for the Study Group) or not (from 10 to 20 mm/Hg for the Control Group).
Outcomes of the study Outcome measures in this study were the perineal and cervical lacerations incidence, the use of uterine fundal pressure maneuver (Kristeller manouvre), the incidence of vacuum extractions, cesarean section incidence during labor, second stage of labor duration; maternal psychological and physical fatigue, maternal request of cesarean section during labor, and absence of neonatal intensive care unit admissions.
At the time of discharge to home, patients' satisfaction with the inflatable belt was evaluated asking them to score about the degree of psychological and physical fatigue with the Baby-guardTM by marking a 10-cm visual analogue scale (VAS) from 0 (minimal) to 10 (optimal). Patients were also asked about the usefulness of the inflatable belt assistance to delivery. The number of cesarean section requests during the second phase of labor was also evaluated.
Statistical analysis All data were analyzed with the STATA software (StataCorp LP, College Station, Texas, USA), and were expressed as mean ± SD (range) or as number (%) of cases. Comparisons of proportions and means between groups (study vs control) were done using the χ2 test (or Fisher exact test, if suitable) and, independent t-test, respectively.
Study design
- Primary purpose
- Health services research
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (investigator)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Baby-guardTM | Experimental | Device: Baby-guardTMBaby-guardTM system, through its ergonomic, three chamber, inflatable abdominal belt, engineered after studies of biomechanics and biophysics, that follows obstetric semiotics, that applies fundal pressure during the second stage of labor in the direction of the pelvic outlet. |
| no intervention | No intervention | –Baby-guardTM system, without inflation |
Who may qualify
- Ages
- 23 to 42 years
- Sex
- Female only
- Healthy volunteers
- Accepted
- Age groups
- Adult
Key inclusion criteria (2 listed)
- women in active labor at term in primipara with maternal age ranging from 23 to 42 years, with a singleton fetus in vertex presentation.
- the onset of second stage was defined as full dilatation of the cervix identified by digital examination
Key exclusion criteria (9 listed)
- preterm labor (gestational age below 37 weeks)
- breech or transverse presentation
- suspected fetal macrosomia
- gestational diabetes
- pregnancy-induced hypertension
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Baby-guardTMAlso: Safety baby guardBaby-guardTM system, through its ergonomic, three chamber, inflatable abdominal belt, engineered after studies of biomechanics and biophysics, that follows obstetric semiotics, that applies fundal pressure during the second stage of labor in the direction of the pelvic outlet, may be of maternal and fetus aid for a safe natural childbirth for their better outcomes | Device | Baby-guardTM |
Primary outcome
Partecipant With Perineal Laceration
Time frame: after delivery
The following types of lacerations were recorded during delivery: cervical laceration; mild perineal lacerations (defined as 1-2 lacerations); severe perineal lacerations (defined as 3-4 lacerations)
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 12 Dec 2016.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Background: PubMed 19774390Hoogsteder PH, Pijnenborg JM. Use of uterine fundal pressure maneuver at vaginal delivery and risk of severe perineal laceration. Arch Gynecol Obstet. 2010 Mar;281(3):579-80. doi: 10.1007/s00404-009-1229-3. Epub 2009 Sep 23. No abstract available.
- Background: PubMed 8828318Cosner KR. Use of fundal pressure during second-stage labor. A pilot Study. J Nurse Midwifery. 1996 Jul-Aug;41(4):334-7. doi: 10.1016/0091-2182(96)00033-x.
- Background: PubMed 19900147Api O, Api M. Uterine fundal pressure and duration of the second stage of labor: A randomized controlled trial. Acta Obstet Gynecol Scand. 2009;88(11):1297-8. doi: 10.3109/00016340903214999. No abstract available.
- Derived from this study: PubMed 23083494Acanfora L, Rampon M, Filippeschi M, Marchi M, Montisci M, Viel G, Cosmi E. An inflatable ergonomic 3-chamber fundal pressure belt to assist vaginal delivery. Int J Gynaecol Obstet. 2013 Jan;120(1):78-81. doi: 10.1016/j.ijgo.2012.07.025. Epub 2012 Oct 16.
- Individual participant dataSharing planned: No
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
luisa Acanfora, MD study chair
University of Florence
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 2 study testing Baby-guardTM in people with Other Obstetric Trauma - Delivered, run by University of Padova at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 12 Dec 2016. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
Yes. Results are posted in the registry (first posted 12 Dec 2016). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Partecipant With Perineal Laceration (time frame: after delivery). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01566331, which also lists 4 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Dec 2016.