AzTrials
AzTrials

Other Obstetric Trauma - DeliveredPhase 2SDBNCT01566331

Safe Delivery Using a Belt on the Belly of Pregnant Woman

A Phase 2 study testing Baby-guardTM in people with Other Obstetric Trauma - Delivered, run by University of Padova at 1 site in Italy.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Safety of natural, vaginal labor for parturient, fetus and newborn is one of most important goal among obstetricians, midwifes, scientific society all over the world. Maternal and newborn clinical problems and complications following vaginal delivery cause a big amount of medico-legal problems and high costs in the… Read more about this study

Who is it for?
Ages 23 to 42 years, women onlyHealthy volunteers can take part
Conditions the study is for
Other Obstetric Trauma - Delivered
What is being tested?
Baby-guardTM
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
80 participants
Where
1 siteItaly
Study dates
Jan 2011to Mar 2011
Phase
Phase 2
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 23 to 42 years
  • Women only
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • women in active labor at term in primipara with maternal age ranging from 23 to 42 years, with a singleton fetus in vertex presentation.
  • the onset of second stage was defined as full dilatation of the cervix identified by digital examination

Who cannot join

  • preterm labor (gestational age below 37 weeks)
  • breech or transverse presentation
  • suspected fetal macrosomia
  • gestational diabetes
  • pregnancy-induced hypertension
  • abnormalities of placentation (low lying placenta, abruptio placenta)
Show all 9Show fewer
  • uterine structural abnormalities
  • history of previous uterine scar
  • fetal heart rate abnormalities at the time of enrollment (bradycardia, tachycardia or prolonged variable decelerations).

Trial locations and contacts

1 site in 1 country.

Italy1 site
  • University of Padua

    Padua, Padua, 35128

Other trials in Italy

About this study

Official title: Safe Natural Delivery by Using a New Inflatable Ergonomic Three Chambers Belt

Safety of natural, vaginal labor for parturient, fetus and newborn is one of most important goal among obstetricians, midwifes, scientific society all over the world. Maternal and newborn clinical problems and complications following vaginal delivery cause a big amount of medico-legal problems and high costs in the sanitary field.

Among the maneuvers that are used in the second stage of labor, uterine fundal pressure is one of the most controversial and often diffuse in all over the world, generally not documented, or under reported in medical records . Many Authors affirms that a different new way to push may be of help. This maneuver was introduced by Kristeller, that in 1867 minutely described a procedure to shorten, through the application of a pressure on the uterine fundus whose intensity was quantified by a dynamometer and the duration measured in seconds, the length of the second phase of the labor. Although uterine fundal pressure maneuver was described by Kristeller as the placement of two hands on the uterine fundus and the consequential application of longitudinal steady pressure at a 30- to 45-degree angle directed toward the pelvis, with the avoidance of direct pressure toward the maternal spine, there is no clear definition of the maneuver and no indication for its use has been formally described to date.

The aim of this study was therefore to assess whether the use of the Baby-guardTM system, through its ergonomic, three chamber, inflatable abdominal belt, engineered after studies of biomechanics and biophysics, that follows obstetric semiotics, that applies fundal pressure during the second stage of labor in the direction of the pelvic outlet, may be of maternal and fetus aid for a safe natural childbirth for their better outcomes.

Read the detailed description

A randomized, single blind, controlled, prospective study was performed. Subjects were nulliparous women who delivered at a community setting hospital (U.O.C. Obstetrics and Gynecology, "San Giuseppe" Hospital, Empoli, Italy) between January 24, 2011 and March 24, 2011. Vaginal deliveries were eligible. Patients were therefore divided into two groups by randomly numbered envelopes upon full dilatation of the cervix, and allocated to the following two groups:

  1. The Study Group (n=40 patients) in whom the inflatable belt was applied with the correct pressures (ranging from 80 to 150 mm/Hg, see below the description of the protocol)during Labor and Delivery
  2. The Control Group (n=40 women), in whom the belt was inflated with minimal pressures (from 10 to 20 mm/Hg) During Labor and Delivery To test whether differences between experimental groups are statistically significant, the sample-size should be calculated "a priori". To do this, a primary end-point has been identified: incidence of perineal-cervical lacerations. The sample-size (n > 62 subjects for two groups) will be obtained using STATA program by a two-tailed test [alpha level of 0.05 and 90% of statistical power (1-Beta)], to detect statistically significant reduction from 50% to 10% or less with respect the primary end-point. Therefore a randomized sample size of 40 pregnant women per group was chosen to allow for possible refusals or withdrawals.

Data collected from delivery records, retrospectively obtained and reviewed, will include: patient's age, race, parity, patient's body mass index (BMI, kg/m2) at the time of delivery, and body weight change during pregnancy (defined as the difference between maternal pre-pregnant body weight and body weight at delivery), as part of the ante-partum information. For the intra-partum information, gestational age at delivery, duration of second phase of labor, use of intravenous oxytocin, episiotomy, cervical laceration (as requiring surgical repair for hemostasis), severe perineal lacerations (defined as third- or fourth- laceration, while mild perineal laceration was defend as first- or second- perineal laceration), vacuum extraction, forceps delivery, use of uterine fundal pressure maneuver were abstracted. All The study Group will followed up for 15 days after delivery Fetal weight was estimated by the combination of biparietal diameter, abdominal circumference and femur length. The mean percent difference between the predicted and actual weight was 9.6% corresponding to a mean overestimation of 294 g or underestimation of 314 g. These values are consistent with most reports in the literature.

The study will be performed according to the guidelines of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH); the declaration of Helsinki regarding the Standard operating procedures for clinical investigators (GCP); the General requirements for Clinical investigation of medical devices for human subjects. Finally, the local ethical committee approved the study protocol, and all patients received detailed information about the study and the procedure, to which they gave their written consent.

The inflatable belt (Baby-guardTM ) and study protocol The Baby-guardTM (CABEL s.a.s. Costruzioni Elettroniche, Pistoia, Italy) consists of a disposable, ergonomic, three chambers, inflatable belt, and a detector of electro-physiological signals from maternal abdomen (i.e. fetal heart and maternal heart signals - Figure 1). myographic uterine activity). Three chambers that can be separately swollen one from the other in order to repositioning fetal body compose the inflatable belt. The three belt chambers are filled according to the pressures set by the operator (midwife/MD) and allow to gently positioning of the fetus in the wright position towards the pelvis. Once the correct fetal position has been obtained, all three chambers are inflated in synchronously with uterine contraction. The maternal and fetal monitoring unit is composed by a touch-screen computer, that records electro-physiological signals collected by a signal amplifier deriving from the mother (uterine contractions and the maternal heart rate) and the fetus (fetal heart rate and the possibility of Doppler parameters of fetal heart). All parameters and signals detected by the Baby-guardTM system are storable on the touch-screen computer hard disk, as per request of the European Community rules on safety (UNI EN60601)].

This study reports only the part regarding results and outcomes of parturient and neonates.

At the beginning of the uterine contraction, as referred by the patients and revealed by the electro-physiological signals recorded, the midwife/MD, if necessary, inflated 30-50 mmHg of air pressure into the lateral chambers of the inflatable belt to correctly align the fetus avoiding his malpositioning with respect to the pelvis. After monitoring the duration of spontaneous uterine contractions, the midwife/MD therefore inflated from 80 to 150 mm/Hg (for the Study Group) or from 10 to 20 mm/Hg (for the Control Group) of air into the ergonomic belt for 30 sec. Fundal pressure was applied at a 30-40° angle to the spine in the direction of the pelvic outlet through the inflatable belt, standardizing the force and surface area of application (980 cm2). The frequency of inflation was limited to fewer than 6 times per 20 min. followed by a pause of 10 min. All the women, whether randomized to the Study or the Control group, received standard management of the second stage of labor, which includes one-to-one support, fetal heart rate monitoring, and care from midwife. Operative deliveries were performed if clinically indicated. As a uterine contraction started, the inflatable obstetric belt was inflated synchronously and maintained at the pressure above indicated for 30 sec. by the midwife/MD. The Baby-guardTM was not used for more than 2 hours till delivery. The obstetrician, the midwife and the patients were blind to whether the belt was inflated with sufficient pressure (from 80 to 150 mm/Hg for the Study Group) or not (from 10 to 20 mm/Hg for the Control Group).

Outcomes of the study Outcome measures in this study were the perineal and cervical lacerations incidence, the use of uterine fundal pressure maneuver (Kristeller manouvre), the incidence of vacuum extractions, cesarean section incidence during labor, second stage of labor duration; maternal psychological and physical fatigue, maternal request of cesarean section during labor, and absence of neonatal intensive care unit admissions.

At the time of discharge to home, patients' satisfaction with the inflatable belt was evaluated asking them to score about the degree of psychological and physical fatigue with the Baby-guardTM by marking a 10-cm visual analogue scale (VAS) from 0 (minimal) to 10 (optimal). Patients were also asked about the usefulness of the inflatable belt assistance to delivery. The number of cesarean section requests during the second phase of labor was also evaluated.

Statistical analysis All data were analyzed with the STATA software (StataCorp LP, College Station, Texas, USA), and were expressed as mean ± SD (range) or as number (%) of cases. Comparisons of proportions and means between groups (study vs control) were done using the χ2 test (or Fisher exact test, if suitable) and, independent t-test, respectively.

Being tested
Baby-guardTM
Keywords
Safe Delivery, reduction of pain, reduction stage of labor

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Baby-guardTMDevice

    Also called Safety baby guard

    Baby-guardTM system, through its ergonomic, three chamber, inflatable abdominal belt, engineered after studies of biomechanics and biophysics, that follows obstetric semiotics, that applies fundal pressure during the second stage of labor in the direction of the pelvic outlet, may be of maternal and fetus aid for a safe natural childbirth for their better outcomes

Study groups in NCT01566331
Study groupRoleWhat they receive
Baby-guardTMExperimentalBaby-guardTM system, through its ergonomic, three chamber, inflatable abdominal belt, engineered after studies of biomechanics and biophysics, that follows obstetric semiotics, that applies fundal pressure during the second stage of labor in the direction of the pelvic outlet.
Receives: Device: Baby-guardTM
no interventionNo interventionBaby-guardTM system, without inflation

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Partecipant With Perineal Laceration

    The following types of lacerations were recorded during delivery: cervical laceration; mild perineal lacerations (defined as 1-2 lacerations); severe perineal lacerations (defined as 3-4 lacerations)

    Measured: after delivery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Mar 2012 (estimated)
  2. Study startJan 2011
  3. Primary completionMar 2011
  4. Study completionMar 2011

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 2
Primary purpose
Health services research
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Investigator
Enrolment
80 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01566331
Sponsor's protocol ID
unipd
Acronym
SDB
Status last verified
Oct 2016
First submitted
19 Mar 2012
Last updated
12 Dec 2016
Data monitoring committee
Yes
Individual data sharing
No

Publications

  • Hoogsteder PH, Pijnenborg JM. Use of uterine fundal pressure maneuver at vaginal delivery and risk of severe perineal laceration. Arch Gynecol Obstet. 2010 Mar;281(3):579-80. doi: 10.1007/s00404-009-1229-3. Epub 2009 Sep 23. No abstract available.

    PubMed 19774390
  • Cosner KR. Use of fundal pressure during second-stage labor. A pilot Study. J Nurse Midwifery. 1996 Jul-Aug;41(4):334-7. doi: 10.1016/0091-2182(96)00033-x.

    PubMed 8828318
  • Api O, Api M. Uterine fundal pressure and duration of the second stage of labor: A randomized controlled trial. Acta Obstet Gynecol Scand. 2009;88(11):1297-8. doi: 10.3109/00016340903214999. No abstract available.

    PubMed 19900147
  • Acanfora L, Rampon M, Filippeschi M, Marchi M, Montisci M, Viel G, Cosmi E. An inflatable ergonomic 3-chamber fundal pressure belt to assist vaginal delivery. Int J Gynaecol Obstet. 2013 Jan;120(1):78-81. doi: 10.1016/j.ijgo.2012.07.025. Epub 2012 Oct 16.

    PubMed 23083494

Questions about this trial

What is this clinical trial studying?

A Phase 2 study testing Baby-guardTM in people with Other Obstetric Trauma - Delivered, run by University of Padova at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 12 Dec 2016. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Yes. Results are posted in the registry (first posted 12 Dec 2016). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Partecipant With Perineal Laceration (time frame: after delivery). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01566331, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Dec 2016.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in