Hemodynamic InstabilityNCT01569308
Pulse Pressure Variation Helps to Predict Fluid Responsiveness in Patients Ventilated With Low Tidal Volumes
An observational study of Hemodynamic Instability, run by Hospital de Clinicas de Porto Alegre at 1 site in Brazil.
Trial summary
Objective: To determine the value of pulse pressure variation (ΔRESPPP) to predict fluid responsiveness in patients ventilated with low tidal volumes (VT), and to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes. Read more about this study
- Who is it for?
- Ages 16 years and older
- Conditions the study is for
- Hemodynamic Instability
- How many people
- 38 participants
- Where
- 1 siteBrazil
- Study dates
- May 2006to Oct 2009
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 16 years and older
- All sexes
- No healthy volunteers
- Child, Adult, Older adult
Study population: Patients age ≥ 16 years, from both genders, admitted to the HCPA ICU, receiving invasive mechanical ventilation, with hemodynamic instability defined as need for norepinephrine infusion and/or intravascular fluid administration to maintain systolic arterial blood pressure > 90 mm Hg; with arterial line in place (radial or femoral) and pulmonary arterial catheter in place.
Who may be able to join
- Age ≥ 16 years
- Hemodynamic instability defined as need for norepinephrine infusion and/or intravascular fluid administration to maintain systolic arterial blood pressure > 90 mm Hg
- Arterial line in place (radial or femoral)
- Pulmonary arterial catheter in place
Who cannot join
- Presence of cardiac arrhythmias
- Presence of pneumothorax
- Presence of heart valve disease or intracardiac shunt
- Previously diagnosed right ventricular insufficiency
Trial locations and contacts
1 site in 1 country.
Brazil1 site
Hospital de Clinicas de Porto Alegre
Porto Alegre, Rio Grande do Sul, 90035903
About this study
Objective: To determine the value of pulse pressure variation (ΔRESPPP) to predict fluid responsiveness in patients ventilated with low tidal volumes (VT), and to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes.
Methods: This cross-sectional, observational study included 37 critically ill patients with acute circulatory failure requiring fluid challenge. They were sedated and mechanically ventilated with Tidal Volume (VT) 6-7 ml/kg IBW (ideal body weight), monitored by pulmonary artery catheter and arterial line. Mechanical ventilation and hemodynamic parameters, including ΔRESPPP, were measured before and after fluid challenge with 1,000 ml crystalloids or 500 ml colloids. Fluid responsiveness was defined as an increase of at least 15% in cardiac index.
Read more
The present study was designed to (1) determine the value of ΔRESPPP to predict fluid responsiveness in patients ventilated with low tidal volumes, and (2) to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes.
The study hypothesis is not a good predictor of fluid responsiveness in patients ventilated with low tidal volumes.
Read the detailed description
Volume expansion is frequently used to treat critically ill patients with acute circulatory failure. The goal of volume expansion is to increase left ventricular stroke volume and consequently cardiac output. However, about 50% of patients with acute circulatory failure will respond to fluid challenge (preload- dependent patients). Therefore, the ability to predict fluid responsiveness in critically ill patients is crucial, particularly for ARDS patients because of increased alveolar-capillary membrane permeability, and avoiding unnecessary fluid loading has been shown to have a positive effect on patient outcome.Among the dynamic parameters used at the bedside to identify fluid responsiveness, pulse pressure variation (ΔRESPPP) is one of the most accurate in patients with acute circulatory failure receiving invasive mechanical ventilation. However, most studies evaluated patients ventilated with large tidal volumes (≥ 8 ml/kg). Therefore, the validity of ΔRESPPP to identify fluid responsiveness is still debated when lower tidal volumes are used.
The current literature about its performance during ventilation with low tidal volumes is unclear, and opposite conclusions have been drawn. The present study was designed to (1) determine the value of ΔRESPPP to predict fluid responsiveness in patients ventilated with low tidal volumes, and (2) to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes.
Methods: This cross-sectional, observational study included 37 critically ill patients with acute circulatory failure requiring fluid challenge. They were sedated and mechanically ventilated with Tidal Volume (VT) 6-7 ml/kg IBW (ideal body weight), monitored by pulmonary artery catheter and arterial line. Mechanical ventilation and hemodynamic parameters, including ΔRESPPP, were measured before and after fluid challenge with 1,000 ml crystalloids or 500 ml colloids. Fluid responsiveness was defined as an increase of at least 15% in cardiac index.
Patients were followed for 28 days or until discharge from the ICU.
Study Protocol Patients were sedated with midazolan and fentanyl (score of -4 to -5 in the Richmond Agitation Sedation Scale)and ventilated in controlled pressure or controlled volume mode (Servo I system v.12 or Servo 900 C, Siemens, Sweden) with VT < 8 ml/kg IBW (51 + 0.9[height in cm- 152.9] for men and 45.5 + 0.91[height in cm- 152.9] for women). Ventilatory and hemodynamic variables were measured before and after FC with the patients in a supine position. Zero pressure was measured at the midaxillary line. The correct position of the pulmonary artery catheter in West's zone 3 was checked as described in the literature.
Fluid challenge was performed with 1000 ml 0.9% saline solution or lactated Ringer's solution (n=36) or 500 ml hydroxy-ethyl-starch solution 6% 130/0.4 for 30 minutes (n=2).
Hemodynamic Parameters
Variations in arterial pulse pressure were visualized on bedside monitors (HP S66 and PHILIPS IntelliVue, MP60, Germany) and measured with the cursor for each of 5 breathing cycles. ΔRESPPP was calculated using the following equation:
ΔRESPPP (%) = 100 x (PPmax - PPmin) / [(PPmax + PPmin)/2]
where PPmax and PPmin are the maximal pulse pressure at inspiration and the pulse pressure obtained on expiration, respectively.
A pulmonary artery catheter (Edwards Healthcare, Irvine, CA) was used to measure cardiac output according to the thermal dilution method (3 injections of 10ml 0.9% saline solution), systolic, diastolic and mean pulmonary arterial pressures, pulmonary artery occlusion pressure (PAOP, mmHg), central venous pressure (CVP, mmHg), and mixed venous saturation (SvO2). Mean arterial pressure (MAP, mmHg), measured using the arterial line, and heart rate (HR, bpm) were also recorded. All measurements were made at the end of expiration, before and after FC. Patients were defined as fluid responders when cardiac index increased at least 15% of baseline value.
Ventilation Parameters The following ventilatory parameters were measured: inspiratory and expiratory tidal volume, respiratory rate (RR), plateau pressure (cmH2O), peak pressure (cmH2O), total positive end-expiratory pressure (PEEPtot), static compliance (Cst) and driving pressure (DP= Pplat-PEEP). All measurements were made before and after FC.
Statistical Analysis Sample size was defined as 38 patients for estimation of the correlation between CI and ΔRESPPP 0.5 (moderate to high magnitude), with a level of significance of 0.05 and power of 90%.
The effects of FC on hemodynamic parameters were assessed using a paired Student's t-test for normally distributed variables or a nonparametric Wilcoxon Signed Rank test for non-normally distributed variables. The comparison of hemodynamic parameters between both groups at baseline and after FC was assessed using a two sample Student's t-test or a nonparametric Mann-Whitney U test. Results were expressed as mean values±SD or median (25-75 percentiles).
Receiver operating characteristic (ROC) curves were constructed to evaluate the ability of ΔRESPPP, ΔRESPPP/DP, CVP and PAOP to predict fluid responsiveness. The best cut-off value for ΔRESPPP ROC curve was determined for the entire population. In addition, measures of diagnostic performance were calculated: sensitivity, specificity, predictive values and likelihood ratio. Linear correlations were tested using the Spearman rank method. Data were analyzed using SPSS 15.0. A p value <0.05 was considered significant.
- Conditions
- Hemodynamic Instability
- Keywords
- Cardiac output, Pulse pressure variation, Fluid responsiveness, Low tidal volume
What is being measured
The primary outcome is the main question the study is designed to answer.
Increase in cardiac index at least 15% of baseline value.
Patients were sedated and ventilated in controlled pressure or controlled volume mode (Servo I system v.12 or Servo 900 C, Siemens, Sweden) with VT < 8 ml/kg ideal body weight. Ventilatory and hemodynamic variables were measured before and after FC with the patients in a supine position. Fluid challenge was performed with 1000 ml 0.9% saline solution or lactated Ringer's solution or 500 ml hydroxy-ethyl-starch solution 6% 130/0.4 for 30 minutes. The increase in cardiac index was measured immediately after fluid challenge.
Measured: Cardiac index was measured at the end of a 30 minutes fluid challenge.
Secondary outcomes (1)
Mortality
Patients were followed for 28 days or until ICU discharge
Measured: 28 days
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted3 Apr 2012 (estimated)
- Study startMay 2006
- Primary completionOct 2009
- Study completionOct 2009
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Hemodynamic InstabilityStudies of the same condition, open and under way.
- More trials run by Hospital de Clinicas de Porto AlegreThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Cross-sectional
- Enrolment
- 38 participants (actual)
Sponsor and investigators
- Lead sponsor
- Hospital de Clinicas de Porto Alegre
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Gilberto Friedman, Principal investigator, Hospital de Clinicas de Porto Alegre
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01569308
- Sponsor's protocol ID
- 06-109
- Status last verified
- Mar 2012
- First submitted
- 14 Mar 2012
- Last updated
- 3 Apr 2012
- Results posted
- No
- Data monitoring committee
- Yes
Publications
Oliveira-Costa CD, Friedman G, Vieira SR, Fialkow L. Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes. Clinics (Sao Paulo). 2012 Jul;67(7):773-8. doi: 10.6061/clinics/2012(07)12.
PubMed 22892922
Study at a glance
From the registry record, last updated by the sponsor on 3 Apr 2012. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Pulse Pressure Variation Helps to Predict Fluid Responsiveness in Patients Ventilated With Low Tidal Volumes
- ClinicalTrials.gov ID
- NCT01569308
- Acronym / sponsor ID
- 06-109
- Conditions
- Hemodynamic Instability
- Keywords
- Cardiac output, Pulse pressure variation, Fluid responsiveness, Low tidal volume
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 38 participants (actual)
- Lead sponsor
- Hospital de Clinicas de Porto AlegreUniversity, hospital or other
- Study start
- May 2006
- Primary completion
- Oct 2009 (actual)
- Study completion
- Oct 2009 (actual)
- First posted
- 3 Apr 2012 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Objective: To determine the value of pulse pressure variation (ΔRESPPP) to predict fluid responsiveness in patients ventilated with low tidal volumes (VT), and to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes.
Methods: This cross-sectional, observational study included 37 critically ill patients with acute circulatory failure requiring fluid challenge. They were sedated and mechanically ventilated with Tidal Volume (VT) 6-7 ml/kg IBW (ideal body weight), monitored by pulmonary artery catheter and arterial line. Mechanical ventilation and hemodynamic parameters, including ΔRESPPP, were measured before and after fluid challenge with 1,000 ml crystalloids or 500 ml colloids. Fluid responsiveness was defined as an increase of at least 15% in cardiac index.
The present study was designed to (1) determine the value of ΔRESPPP to predict fluid responsiveness in patients ventilated with low tidal volumes, and (2) to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes.
The study hypothesis is not a good predictor of fluid responsiveness in patients ventilated with low tidal volumes.
Detailed description
Volume expansion is frequently used to treat critically ill patients with acute circulatory failure. The goal of volume expansion is to increase left ventricular stroke volume and consequently cardiac output. However, about 50% of patients with acute circulatory failure will respond to fluid challenge (preload- dependent patients). Therefore, the ability to predict fluid responsiveness in critically ill patients is crucial, particularly for ARDS patients because of increased alveolar-capillary membrane permeability, and avoiding unnecessary fluid loading has been shown to have a positive effect on patient outcome.Among the dynamic parameters used at the bedside to identify fluid responsiveness, pulse pressure variation (ΔRESPPP) is one of the most accurate in patients with acute circulatory failure receiving invasive mechanical ventilation. However, most studies evaluated patients ventilated with large tidal volumes (≥ 8 ml/kg). Therefore, the validity of ΔRESPPP to identify fluid responsiveness is still debated when lower tidal volumes are used.
The current literature about its performance during ventilation with low tidal volumes is unclear, and opposite conclusions have been drawn. The present study was designed to (1) determine the value of ΔRESPPP to predict fluid responsiveness in patients ventilated with low tidal volumes, and (2) to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes.
Methods: This cross-sectional, observational study included 37 critically ill patients with acute circulatory failure requiring fluid challenge. They were sedated and mechanically ventilated with Tidal Volume (VT) 6-7 ml/kg IBW (ideal body weight), monitored by pulmonary artery catheter and arterial line. Mechanical ventilation and hemodynamic parameters, including ΔRESPPP, were measured before and after fluid challenge with 1,000 ml crystalloids or 500 ml colloids. Fluid responsiveness was defined as an increase of at least 15% in cardiac index.
Patients were followed for 28 days or until discharge from the ICU.
Study Protocol Patients were sedated with midazolan and fentanyl (score of -4 to -5 in the Richmond Agitation Sedation Scale)and ventilated in controlled pressure or controlled volume mode (Servo I system v.12 or Servo 900 C, Siemens, Sweden) with VT < 8 ml/kg IBW (51 + 0.9[height in cm- 152.9] for men and 45.5 + 0.91[height in cm- 152.9] for women). Ventilatory and hemodynamic variables were measured before and after FC with the patients in a supine position. Zero pressure was measured at the midaxillary line. The correct position of the pulmonary artery catheter in West's zone 3 was checked as described in the literature.
Fluid challenge was performed with 1000 ml 0.9% saline solution or lactated Ringer's solution (n=36) or 500 ml hydroxy-ethyl-starch solution 6% 130/0.4 for 30 minutes (n=2).
Hemodynamic Parameters
Variations in arterial pulse pressure were visualized on bedside monitors (HP S66 and PHILIPS IntelliVue, MP60, Germany) and measured with the cursor for each of 5 breathing cycles. ΔRESPPP was calculated using the following equation:
ΔRESPPP (%) = 100 x (PPmax - PPmin) / [(PPmax + PPmin)/2]
where PPmax and PPmin are the maximal pulse pressure at inspiration and the pulse pressure obtained on expiration, respectively.
A pulmonary artery catheter (Edwards Healthcare, Irvine, CA) was used to measure cardiac output according to the thermal dilution method (3 injections of 10ml 0.9% saline solution), systolic, diastolic and mean pulmonary arterial pressures, pulmonary artery occlusion pressure (PAOP, mmHg), central venous pressure (CVP, mmHg), and mixed venous saturation (SvO2). Mean arterial pressure (MAP, mmHg), measured using the arterial line, and heart rate (HR, bpm) were also recorded. All measurements were made at the end of expiration, before and after FC. Patients were defined as fluid responders when cardiac index increased at least 15% of baseline value.
Ventilation Parameters The following ventilatory parameters were measured: inspiratory and expiratory tidal volume, respiratory rate (RR), plateau pressure (cmH2O), peak pressure (cmH2O), total positive end-expiratory pressure (PEEPtot), static compliance (Cst) and driving pressure (DP= Pplat-PEEP). All measurements were made before and after FC.
Statistical Analysis Sample size was defined as 38 patients for estimation of the correlation between CI and ΔRESPPP 0.5 (moderate to high magnitude), with a level of significance of 0.05 and power of 90%.
The effects of FC on hemodynamic parameters were assessed using a paired Student's t-test for normally distributed variables or a nonparametric Wilcoxon Signed Rank test for non-normally distributed variables. The comparison of hemodynamic parameters between both groups at baseline and after FC was assessed using a two sample Student's t-test or a nonparametric Mann-Whitney U test. Results were expressed as mean values±SD or median (25-75 percentiles).
Receiver operating characteristic (ROC) curves were constructed to evaluate the ability of ΔRESPPP, ΔRESPPP/DP, CVP and PAOP to predict fluid responsiveness. The best cut-off value for ΔRESPPP ROC curve was determined for the entire population. In addition, measures of diagnostic performance were calculated: sensitivity, specificity, predictive values and likelihood ratio. Linear correlations were tested using the Spearman rank method. Data were analyzed using SPSS 15.0. A p value <0.05 was considered significant.
Study design
- Observational model
- Cohort
- Time perspective
- Cross-sectional
Who may qualify
- Ages
- 16 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
- Study population
- Patients age ≥ 16 years, from both genders, admitted to the HCPA ICU, receiving invasive mechanical ventilation, with hemodynamic instability defined as need for norepinephrine infusion and/or intravascular fluid administration to maintain systolic arterial blood pressure > 90 mm Hg; with arterial line in place (radial or femoral) and pulmonary arterial catheter in place.
Key inclusion criteria (4 listed)
- Age ≥ 16 years
- Hemodynamic instability defined as need for norepinephrine infusion and/or intravascular fluid administration to maintain systolic arterial blood pressure > 90 mm Hg
- Arterial line in place (radial or femoral)
- Pulmonary arterial catheter in place
Key exclusion criteria (4 listed)
- Presence of cardiac arrhythmias
- Presence of pneumothorax
- Presence of heart valve disease or intracardiac shunt
- Previously diagnosed right ventricular insufficiency
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
Increase in cardiac index at least 15% of baseline value.
Time frame: Cardiac index was measured at the end of a 30 minutes fluid challenge.
Patients were sedated and ventilated in controlled pressure or controlled volume mode (Servo I system v.12 or Servo 900 C, Siemens, Sweden) with VT < 8 ml/kg ideal body weight. Ventilatory and hemodynamic variables were measured before and after FC with the patients in a supine position. Fluid challenge was performed with 1000 ml 0.9% saline solution or lactated Ringer's solution or 500 ml hydroxy-ethyl-starch solution 6% 130/0.4 for 30 minutes. The increase in cardiac index was measured immediately after fluid challenge.
1 secondary outcome
Mortality
Time frame: 28 days
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 3 Apr 2012.
- Derived from this study: PubMed 22892922Oliveira-Costa CD, Friedman G, Vieira SR, Fialkow L. Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes. Clinics (Sao Paulo). 2012 Jul;67(7):773-8. doi: 10.6061/clinics/2012(07)12.
Related trials for Hemodynamic Instability
RecruitingPhase 4
Effect of Remimazolam Versus Propofol Total Intravenous Anesthesia on Intraoperative Hemodynamic Stability in Patients Undergoing Thoracic or Abdominal Endovascular Aortic Repair
Aortic Aneurysm, Thoracoabdominal, Aortic Aneurysm, Abdominal
Not yet recruiting
Dexametedomidine Ketamine Infusion Versus Dexametedomidine Propofol Infusion in Non-compliant Agitated Patients on Continuous Positive Airway Pressure (CPAP) Mask Ventilation in the Intensive Care Unit
CPAP Ventilation, Sedation
RecruitingObservational study
Machine Learning-Assisted Management of Intraoperative Hypotension for Personalized Treatment
Intraoperative Hypotension, Perioperative Care
Not yet recruitingObservational study
Development and Internal Validation of a Multimodal Prediction Score for Early Hemodynamic Deterioration in Adult Polytrauma Patients
Multiple Trauma, Polytrauma
RecruitingObservational study
Internal Jugular Vein Ultrasound and Acute Kidney Injury After Abdominal Surgery
Intraoperative Hypotension, Jugular Veins
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Gilberto Friedman principal investigator
Hospital de Clinicas de Porto Alegre
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Hemodynamic Instability, run by Hospital de Clinicas de Porto Alegre at 1 site in Brazil.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 3 Apr 2012. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Brazil. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Increase in cardiac index at least 15% of baseline value. (time frame: Cardiac index was measured at the end of a 30 minutes fluid challenge.). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01569308, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 3 Apr 2012.