AzTrials
AzTrials

Atrial FibrillationPhase 4NCT01587404

Catheter Contact Force and Electrograms

A Phase 4 study testing THERMOCOOL® SMARTTOUCH™ Catheter (including Surround Flow) in people with Atrial Fibrillation, run by Barts & The London NHS Trust at 1 site in United Kingdom.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Until recently, there was no way of telling how firmly the tip of the catheter was in contact with the heart and how this contact was orientated. The electrical signals measured through the catheters, known as electrograms, are used to guide the sites and duration of ablation, but the effect of catheter contact and… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Atrial Fibrillation
What is being tested?
THERMOCOOL® SMARTTOUCH™ Catheter (including Surround Flow)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
55 participants
Where
1 siteUnited Kingdom
Study dates
Apr 2012to 21 Aug 2018
Phase
Phase 4
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Persistent or paroxysmal atrial fibrillation
  • Listed for ablation of atrial fibrillation on clinical grounds

Who cannot join

  • Contraindication to catheter ablation
  • Contraindication to anticoagulation
  • Contraindication to TOE

Trial locations and contacts

1 site in 1 country.

United Kingdom1 site
  • St Bartholomew's Hospital

    London, EC1A 7BE

Other trials in United Kingdom

About this study

Official title: Relationship Between Catheter Contact Force and Electrogram Characteristics in Fibrillating Human Atrial Myocardium

Until recently, there was no way of telling how firmly the tip of the catheter was in contact with the heart and how this contact was orientated. The electrical signals measured through the catheters, known as electrograms, are used to guide the sites and duration of ablation, but the effect of catheter contact and orientation on these signals in human heart muscle that is fibrillating is not known. New catheters have now been developed which can measure the force of contact at their tip: using these, the investigators will examine how contact force affects the electrical behaviour of heart muscle tissue in atrial fibrillation. The effect the force of contact has on the electrogram recorded will also be investigated. In so doing we hope to gain a better understanding of the relationship between tissue contact and the electrograms we measure and in so doing improve the safety and effectiveness of ablation procedures.

Hypothesis: Catheter contact force and orientation have a significant impact on the characteristics of bipolar electrograms in the fibrillating human atrium.

Being tested
THERMOCOOL® SMARTTOUCH™ Catheter (including Surround Flow)
Keywords
Atrial Fibrillation, Electrogram, Ablation, Contact Force
Medical subject headings
Atrial Fibrillation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • THERMOCOOL® SMARTTOUCH™ Catheter (including Surround Flow)Device

    Variable contact force as measured at the catheter tip within the left atrium

Study groups in NCT01587404
Study groupRoleWhat they receive
Constant Catheter Contact ForceExperimentalNo alteration of catheter contact force during recording period
Receives: Device: THERMOCOOL® SMARTTOUCH™ Catheter (including Surround Flow)
Variable catheter contact forceExperimentalchange in contact force from low to high after 30seconds of recording.
Receives: Device: THERMOCOOL® SMARTTOUCH™ Catheter (including Surround Flow)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Electrogram characteristics

    Effect of changes in contact force and orientation on: slew rate, local mean cycle length, electrogram complexity and fractionation index, dominant frequency, organisation index, CFAE grade, interval confidence level, shortest complex interval and average complex interval

    Measured: Baseline and 30 seconds

Secondary outcomes (4)
  1. Electrogram amplitude

    Measured: Baseline and 30 seconds

  2. Electrogram responses to ablation

    Slew rate, local mean cycle length, electrogram complexity and fractionation index, dominant frequency, organisation index, CFAE grade, interval confidence level, shortest complex interval and average complex interval, amplitude change, AF cycle length, catheter impedance.

    Measured: Baseline and 30 seconds

  3. Ablation Power (Watts)

    The interaction between catheter contact force and orientation and the power attained during power limited ablation

    Measured: Baseline and 30 seconds

  4. Electrogram Contact Mapping

    Use of contact catheters - Constellation and/or PentaRay Catheter to record fibrillatory electrograms and identify areas of interest

    Measured: During Study

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted30 Apr 2012 (estimated)
  2. Study startApr 2012
  3. Primary completion31 May 2017
  4. Study completion21 Aug 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
55 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01587404
Sponsor's protocol ID
007856 BLT
Status last verified
Sep 2019
First submitted
23 Apr 2012
Last updated
30 Sep 2019
Results posted
No

Publications

  • Ullah W, Hunter RJ, Baker V, Ling LH, Dhinoja MB, Sporton S, Earley MJ, Schilling RJ. Impact of Catheter Contact Force on Human Left Atrial Electrogram Characteristics in Sinus Rhythm and Atrial Fibrillation. Circ Arrhythm Electrophysiol. 2015 Oct;8(5):1030-9. doi: 10.1161/CIRCEP.114.002483. Epub 2015 Jul 7.

    PubMed 26152560
  • Ullah W, Hunter RJ, Baker V, Dhinoja MB, Sporton S, Earley MJ, Schilling RJ. Target indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram, and biophysical parameter analysis. Circ Arrhythm Electrophysiol. 2014 Feb;7(1):63-8. doi: 10.1161/CIRCEP.113.001137. Epub 2014 Jan 18.

    PubMed 24443504

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing THERMOCOOL® SMARTTOUCH™ Catheter (including Surround Flow) in people with Atrial Fibrillation, run by Barts & The London NHS Trust at 1 site in United Kingdom.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 30 Sep 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Electrogram characteristics (time frame: Baseline and 30 seconds). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01587404, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Sep 2019.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in