Coronary Artery DiseasePhase 3NCT01635881
Evaluation of Coronary Luminal Diameter Enlargement With Emerge™ 1.20 mm PTCA Dilatation Catheter
A Phase 3 study testing Emerge™ 1.20 mm PTCA Dilatation Catheter in people with Coronary Artery Disease, run by Boston Scientific Corporation at 1 site in United States.
Trial summary
To evaluate the acute safety and device procedural success of the Emerge 1.20 mm PTCA dilatation catheter when used as a pre-dilatation device in the stenotic portion of coronary arteries or bypass grafts. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Coronary Artery Disease
- What is being tested?
- Emerge™ 1.20 mm PTCA Dilatation Catheter
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 60 participants
- Where
- 1 siteUnited States
- Study dates
- Jul 2012to Dec 2012
- Phase
- Phase 3
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
None listed.
Who cannot join
- Subject with a known hypersensitivity or contraindication to Aspirin, Heparin, Bivalirudin, anti-platelet medications, or sensitivity to contrast media which cannot be adequately pre-medicated.
- Subject with known diagnosis of an acute myocardial infarction (AMI) within 72 hours prior to index procedure.
- Subject with known pregnancy or is nursing. Women of childbearing potential should have a documented negative pregnancy test within 7 days before index procedure.
- Planned or actual target lesion treatment with an unapproved device, atherectomy, laser, cutting balloon or thrombectomy during the index procedure.
- A serum creatinine level > 2.0 mg/dl within seven days prior to index procedure.
- Cerebrovascular accident (CVA) within the past 6 months.
Show all 21Show fewer
- Active peptic ulcer or active gastrointestinal (GI) bleeding within the past 6 months.
- Subject has a known left ventricular ejection fraction (LVEF) <30% (LVEF may be obtained at the time of the index procedure if the value is unknown, if necessary).
- Angiographic Exclusion Criteria
- More than two lesions requiring treatment.
- Unprotected left main coronary artery disease.
- Coronary artery spasm of the target vessel in the absence of a significant stenosis.
- Target lesion with angiographic presence of probable or definite thrombus.
- Untreated lesions with >50% diameter stenosis remaining in any coronary artery.
- Target lesion involves a bifurcation requiring treatment with more than one stent or pre-dilatation of a side branch >2.0 mm in diameter.
- Non-target lesion to be treated during the index procedure meets any of the following criteria:
- Located within a bypass graft (venous or arterial)
- Left main location
- Chronic total occlusion
- Involves a bifurcation (e.g., bifurcations requiring treatment with more than 1 stent)
- Treatment not deemed a clinical angiographic success
Trial locations and contacts
1 site in 1 country.
About this study
Official title: EMERGE: Evaluation of Coronary Luminal Diameter Enlargement With Emerge™ 1.20 mm Percutaneous Transluminal Coronary Angioplasty (PTCA) Dilatation Catheter
To evaluate the acute safety and device procedural success of the Emerge 1.20 mm PTCA dilatation catheter when used as a pre-dilatation device in the stenotic portion of coronary arteries or bypass grafts.
- Conditions
- Coronary Artery Disease
- Being tested
- Emerge™ 1.20 mm PTCA Dilatation Catheter
- Medical subject headings
- Coronary Artery Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Emerge™ 1.20 mm PTCA Dilatation CatheterDevice
The Emerge 1.20 mm device is the next-generation Boston Scientific PTCA dilatation catheter. It is a sterile, single-use, intravascular medical device used to improve lumen diameter.
The catheter consists of a shaft with a balloon near the distal tip. The balloon is designed to provide an inflatable segment of known diameter and length at recommended pressures.
| Study group | Role | What they receive |
|---|---|---|
| Emerge | Experimental | Single arm with investigational Emerge™ 1.20 mm PTCA Dilatation Catheter Receives: Device: Emerge™ 1.20 mm PTCA Dilatation Catheter |
What is being measured
The primary outcome is the main question the study is designed to answer.
Device Procedural Success
Device procedural success consisting of the following:
- Successful delivery, inflation, deflation and withdrawal of the study balloon.
- No evidence of vessel perforation, flow limiting dissection (grade C or higher) or reduction in TIMI flow from baseline related to the study balloon.
- Final TIMI flow grade of 3 at the conclusion of the percutaneous coronary intervention procedure
Measured: Peri-procedural
Secondary outcomes (1)
In-hospital Major Adverse Cardiac Events (MACE)
In-hospital MACE:
- All death (cardiac and non-cardiac)
- Myocardial infarction (MI)
- Target Vessel Revascularization (TVR)
- In-hospital Stent Thrombosis (ST) within the target vessel
- Clinically significant arrhythmias (requiring intervention)
Measured: Participants will be followed for the duration of hospital stay (an expected average of 24 hours)
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted10 Jul 2012 (estimated)
- Study startJul 2012
- Primary completionDec 2012
- Study completionDec 2012
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- More trials run by Boston Scientific CorporationThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 3
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 60 participants (actual)
Sponsor and investigators
- Lead sponsor
- Boston Scientific Corporation
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- David E Kandzari, MD, Principal investigator, Director, Interventional Cardiology, Chief Scientific Officer, Piedmont Heart Institute
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01635881
- Sponsor's protocol ID
- S2228
- Status last verified
- Oct 2013
- First submitted
- 25 May 2012
- Last updated
- 6 Nov 2013
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 6 Nov 2013. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- EMERGE: Evaluation of Coronary Luminal Diameter Enlargement With Emerge™ 1.20 mm Percutaneous Transluminal Coronary Angioplasty (PTCA) Dilatation Catheter
- ClinicalTrials.gov ID
- NCT01635881
- Acronym / sponsor ID
- S2228
- Conditions
- Coronary Artery Disease
- Phase
- Phase 3
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 60 participants (actual)
- Lead sponsor
- Boston Scientific CorporationIndustry (pharma, biotech, devices)
- Study start
- Jul 2012
- Primary completion
- Dec 2012 (actual)
- Study completion
- Dec 2012 (actual)
- First posted
- 10 Jul 2012 (estimated)
- Results
- Posted 6 Nov 2013
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
To evaluate the acute safety and device procedural success of the Emerge 1.20 mm PTCA dilatation catheter when used as a pre-dilatation device in the stenotic portion of coronary arteries or bypass grafts.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Emerge | Experimental | Device: Emerge™ 1.20 mm PTCA Dilatation CatheterSingle arm with investigational Emerge™ 1.20 mm PTCA Dilatation Catheter |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (0 listed)
Key exclusion criteria (21 listed)
- Subject with a known hypersensitivity or contraindication to Aspirin, Heparin, Bivalirudin, anti-platelet medications, or sensitivity to contrast media which cannot be adequately pre-medicated.
- Subject with known diagnosis of an acute myocardial infarction (AMI) within 72 hours prior to index procedure.
- Subject with known pregnancy or is nursing. Women of childbearing potential should have a documented negative pregnancy test within 7 days before index procedure.
- Planned or actual target lesion treatment with an unapproved device, atherectomy, laser, cutting balloon or thrombectomy during the index procedure.
- A serum creatinine level > 2.0 mg/dl within seven days prior to index procedure.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Emerge™ 1.20 mm PTCA Dilatation CatheterThe Emerge 1.20 mm device is the next-generation Boston Scientific PTCA dilatation catheter. It is a sterile, single-use, intravascular medical device used to improve lumen diameter. The catheter consists of a shaft with a balloon near the distal tip. The balloon is designed to provide an inflatable segment of known diameter and length at recommended pressures. | Device | Emerge |
Primary outcome
Device Procedural Success
Time frame: Peri-procedural
Device procedural success consisting of the following: 1. Successful delivery, inflation, deflation and withdrawal of the study balloon. 2. No evidence of vessel perforation, flow limiting dissection (grade C or higher) or reduction in TIMI flow from baseline related to the study balloon. 3. Final TIMI flow grade of 3 at the conclusion of the percutaneous coronary intervention procedure
1 secondary outcome
In-hospital Major Adverse Cardiac Events (MACE)
Time frame: Participants will be followed for the duration of hospital stay (an expected average of 24 hours)
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 Nov 2013.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
Related trials for Coronary Artery Disease
Active, not recruiting
The OCTOBER Trial - European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction (OCTOBER)
Ischaemic Heart Disease, Ischemic Heart Disease
RecruitingEarly Phase 1
Thiamine Intervention and Coronary Artery Bypass Grafting
Coronary Heart Disease, Coronary Artery Bypass Grafting
RecruitingPhase 4
The Bridging Antiplatelet Therapy With Cangrelor 2 Study
Coronary Arterial Disease (CAD)
Recruiting
Randomized Prospective Trial on the Cost-Effectiveness of Photon-Counting CT Versus Energy-Integrating Detector CT in Suspected Chronic Coronary Syndrome
Computed Tomography Angiography, Coronary Artery Disease
RecruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
David E Kandzari, MD principal investigator
Director, Interventional Cardiology, Chief Scientific Officer, Piedmont Heart Institute
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 3 study testing Emerge™ 1.20 mm PTCA Dilatation Catheter in people with Coronary Artery Disease, run by Boston Scientific Corporation at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 0 inclusion and 21 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 6 Nov 2013. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 3 studies compare the treatment with the current standard treatment or a placebo in a large group, to confirm how well it works and watch for side effects.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
Yes. Results are posted in the registry (first posted 6 Nov 2013). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Device Procedural Success (time frame: Peri-procedural). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?