Pregnant Woman With Premature Rupture of Amnion MembranesNCT01668472
A Comparison of Rapid Immunoassay Tests for the Detection of Ruptured Membranes
An observational study of Pregnant Woman With Premature Rupture of Amnion Membranes, run by University of Colombo at 1 site in Sri Lanka.
Trial summary
Specific objectives include analysis of performance of ROM Plus® in diagnosing ROM, as compared to Amnisure® and the conventional clinical assessment confirmed by a thorough chart review after delivery. Read more about this study
- Who is it for?
- Any age, women onlyHealthy volunteers can take part
- Conditions the study is for
- Pregnant Woman With Premature Rupture of Amnion Membranes
- How many people
- 0 participants
- Where
- 1 siteSri Lanka
- Study dates
- Aug 2012to Dec 2013
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Any age
- Women only
- Healthy volunteers accepted
- Child, Adult, Older adult
Study population: Any pregnant woman who presents with alleged leakage of amniotic fluid is eligible for recruitment
Who may be able to join
- Any woman who presents with alleged leakage of amniotic fluid is eligible for recruitment
Who cannot join
- Known placental previa
- Active vaginal bleeding
Trial locations and contacts
1 site in 1 country.
Sri Lanka1 site
University of Colombo, Department of Obstetrics and Gynecology, Labor and Delivery
Sri Jayewardenepura Kotte, Nubegeda, 168/12
About this study
Specific objectives include analysis of performance of ROM Plus® in diagnosing ROM, as compared to Amnisure® and the conventional clinical assessment confirmed by a thorough chart review after delivery.
Read the detailed description
Premature rupture of membranes (PROM), defined as spontaneous rupture of membranes (ROM) before the onset of uterine contractions, is one of the most common diagnostic dilemmas in contemporary obstetric practice. Premature rupture of membranes can occur at any gestational age, and preterm PROM (PPROM, defined as PROM before 37 weeks) is responsible for 20-40% of preterm births. Early and accurate diagnosis of PROM would allow for gestational age-specific obstetric interventions designed to optimize perinatal outcome and minimize serious complications such as cord prolapse, preterm delivery, fetal distress and infectious morbidity (chorioamnionitis, neonatal sepsis). Conversely, a false-positive diagnosis of PROM may lead to unnecessary obstetric interventions, including hospitalization, administration of antibiotics and corticosteroids, and even induction of labor. Therefore, the correct and timely diagnosis of this disorder is of critical importance to the clinician because PROM and PPROM may be associated with serious maternal and neonatal consequences.
The diagnosis of fetal membrane rupture is conventionally made using a clinical assessment. First, by speculum examination, the clinician looks for amniotic fluid leaking from the cervical os. If clear fluid is visualized leaking from the cervical os, the diagnosis is positive for fetal membrane rupture. More commonly, leaking is absent, and a more extensive workup is required, which includes nitrazine/pH testing, visual inspection of pooling of fluid in the posterior fornix, and a microscopic evaluation of the collected specimen (ferning). Although this approach is considered the standard of care, it is fraught with inaccuracies, requires an intrusive examination and may not provide a rapid diagnosis.
Rapid, point of care, qualitative immunochromatographic tests (ie., Amnisure®, ActimProm®, Amnioquick®) that detect proteins found in amniotic fluid at high concentrations, have been used to diagnose the rupture of membranes (ROM) for several years. In many hospitals, Amnisure® has replaced the sterile speculum exam as the standard of care for diagnosing ROM. It identifies Placental Alpha Microglobulin-1 (PAMG-1), a 34 kd fetal glycoprotein, in cervicovaginal secretions.
Recently a new, rapid, point of care, qualitative immunochromatographic test was introduced to the market, ROM Plus®. Unlike the other immunoassay tests, ROM Plus® uses a unique monoclonal/polyclonal antibody approach to detect two different proteins found in amniotic fluid at high concentrations. ROM Plus® detects Placental Protein-12 (also known as Insulin-like Growth Factor Binding Protein-1) as well as Alpha Fetoprotein (AFP). The combination of PP12 and AFP were chosen not only because of their robust historical literature support as ideal protein markers for amniotic fluid5-22, but also their unique characteristics. PP12 is synthesized by the decidua of the placenta and reaches a very high concentration level in the amniotic fluid early in the first trimester and stays at that level until delivery. However, AFP, synthesized by the fetal liver and yolk sac, reaches its peak concentration late in the second trimester/early third trimester. This increases the chance that the proteins will be detected, especially in the preterm patients, when the diagnosis of ROM is most crucial.
This study is designed to assess the performance (sensitivity, specificity, PPV, NPV) of ROM Plus® and Amnisure®.
- Keywords
- Pregnant, leaking fluid
What is being measured
The primary outcome is the main question the study is designed to answer.
This study is designed to determine number of participants with rupture of membranes from clinical assessment.
The standard of care is to perform a sterile speculum exam and noting the evidence of leakage of fluid from the cervical os, and if necessary, pooling of fluid in the posterior fornix, assessing the fluid with nitrazine/pH and ferning under the microscope. The following chart review criteria will be assessed:
Major Criteria
- the results of the initial SSE (leaking, pooling, ferning, nitrazine) and any follow-up SSE
- the AFI using ultrasound assessment
- the number of hours from the initial exam to delivery (<48 hours will be considered suggestive of ROM)
- evidence of chorioamnionitis and/or endomyometritis
Measured: From hospital presentation on complaint of leaking fluid to delivery estimated to be less than 30 days. (up to 30 days)
Secondary outcomes (2)
Results of AmniSure test.
Amnisure® relies on the detection of PAMG-1 found in amniotic fluid. To perform the Amnisure® test a sample of cervicovaginal secretions is collected using swab placed 5-7cm into the vagina for 1 minute. The swab is then placed into a plastic vial containing a solvent and swirled for 1 minute. The vaginal swab is then removed and discarded. The Amnisure® strip is then placed into the vial for 10 minutes. The test strip is then removed if two lines are clearly visible or after 10 minutes sharp. The results are read by placing the strip on a clean, dry, flat surface. One line indicates a negative result. Two lines indicate a positive result. External controls for both positive and negative samples will be provided and run for every new Amnisure® lot number or shipment received by the hospital.
Measured: From hospital presentation on complaint of leaking fluid to delivery estimated to be less than 30 days. (up to 30 days)
Results of ROM PLus Test
ROM Plus® relies on the detection of PP12 and/or AFP found in amniotic fluid. To perform the ROM Plus® test a sample of cervicovaginal secretions is collected by placing a swab 5-7cm in the vagina for 15 seconds. The swab tip is then placed into the plastic vial containing a buffer solution and mix for 15 seconds. The vaginal swab is then broken off in the vial and the attached dropper-top is placed onto the vial. 4-6 drops are then applied to the "sample" well on the ROM Plus® test cassette. The built-in timer is activated by firmly pressing the finger and rolling the thumb over the timer button from left to right. The test result is interpreted visually by the presence of one or two lines. The presence of one line in the 'C' region indicates a negative result, but that the test device has worked correctly. The presence of two lines (one in the 'AF' region and one in the 'C' region) indicates a positive result and a properly functioning test.
Measured: From hospital presentation on complaint of leaking fluid to delivery estimated to be less than 30 days. (up to 30 days)
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted20 Aug 2012 (estimated)
- Study startAug 2012
- Primary completionAug 2013 (estimated)
- Study completionDec 2013 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Pregnant Woman With Premature Rupture of Amnion MembranesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 0 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Colombo
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Professor Hemantha M. Senanayake, University of Colombo
- Investigators
- Dr. M. Rajapaksha, MD, Study chair, De Soysa Maternity Hospital, Kynsey Road, Colombo 08, Sri Lanka
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01668472
- Sponsor's protocol ID
- SriLankaROMStudy062012
- Status last verified
- Dec 2013
- First submitted
- 19 Jul 2012
- Last updated
- 23 Dec 2013
- Results posted
- No
- Data monitoring committee
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 23 Dec 2013. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Comparison of Rapid Immunoassay Tests for the Detection of Ruptured Membranes
- ClinicalTrials.gov ID
- NCT01668472
- Acronym / sponsor ID
- SriLankaROMStudy062012
- Keywords
- Pregnant, leaking fluid
- Study type
- Observational
- Recruitment status
- Withdrawn
- Enrolment
- 0 participants (actual)
- Lead sponsor
- University of ColomboUniversity, hospital or other
- Study start
- Aug 2012
- Primary completion
- Aug 2013 (estimated)
- Study completion
- Dec 2013 (estimated)
- First posted
- 20 Aug 2012 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Specific objectives include analysis of performance of ROM Plus® in diagnosing ROM, as compared to Amnisure® and the conventional clinical assessment confirmed by a thorough chart review after delivery.
Detailed description
Premature rupture of membranes (PROM), defined as spontaneous rupture of membranes (ROM) before the onset of uterine contractions, is one of the most common diagnostic dilemmas in contemporary obstetric practice. Premature rupture of membranes can occur at any gestational age, and preterm PROM (PPROM, defined as PROM before 37 weeks) is responsible for 20-40% of preterm births. Early and accurate diagnosis of PROM would allow for gestational age-specific obstetric interventions designed to optimize perinatal outcome and minimize serious complications such as cord prolapse, preterm delivery, fetal distress and infectious morbidity (chorioamnionitis, neonatal sepsis). Conversely, a false-positive diagnosis of PROM may lead to unnecessary obstetric interventions, including hospitalization, administration of antibiotics and corticosteroids, and even induction of labor. Therefore, the correct and timely diagnosis of this disorder is of critical importance to the clinician because PROM and PPROM may be associated with serious maternal and neonatal consequences.
The diagnosis of fetal membrane rupture is conventionally made using a clinical assessment. First, by speculum examination, the clinician looks for amniotic fluid leaking from the cervical os. If clear fluid is visualized leaking from the cervical os, the diagnosis is positive for fetal membrane rupture. More commonly, leaking is absent, and a more extensive workup is required, which includes nitrazine/pH testing, visual inspection of pooling of fluid in the posterior fornix, and a microscopic evaluation of the collected specimen (ferning). Although this approach is considered the standard of care, it is fraught with inaccuracies, requires an intrusive examination and may not provide a rapid diagnosis.
Rapid, point of care, qualitative immunochromatographic tests (ie., Amnisure®, ActimProm®, Amnioquick®) that detect proteins found in amniotic fluid at high concentrations, have been used to diagnose the rupture of membranes (ROM) for several years. In many hospitals, Amnisure® has replaced the sterile speculum exam as the standard of care for diagnosing ROM. It identifies Placental Alpha Microglobulin-1 (PAMG-1), a 34 kd fetal glycoprotein, in cervicovaginal secretions.
Recently a new, rapid, point of care, qualitative immunochromatographic test was introduced to the market, ROM Plus®. Unlike the other immunoassay tests, ROM Plus® uses a unique monoclonal/polyclonal antibody approach to detect two different proteins found in amniotic fluid at high concentrations. ROM Plus® detects Placental Protein-12 (also known as Insulin-like Growth Factor Binding Protein-1) as well as Alpha Fetoprotein (AFP). The combination of PP12 and AFP were chosen not only because of their robust historical literature support as ideal protein markers for amniotic fluid5-22, but also their unique characteristics. PP12 is synthesized by the decidua of the placenta and reaches a very high concentration level in the amniotic fluid early in the first trimester and stays at that level until delivery. However, AFP, synthesized by the fetal liver and yolk sac, reaches its peak concentration late in the second trimester/early third trimester. This increases the chance that the proteins will be detected, especially in the preterm patients, when the diagnosis of ROM is most crucial.
This study is designed to assess the performance (sensitivity, specificity, PPV, NPV) of ROM Plus® and Amnisure®.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
Who may qualify
- Sex
- Female only
- Healthy volunteers
- Accepted
- Age groups
- Child, Adult, Older adult
- Study population
- Any pregnant woman who presents with alleged leakage of amniotic fluid is eligible for recruitment
Key inclusion criteria (1 listed)
- Any woman who presents with alleged leakage of amniotic fluid is eligible for recruitment
Key exclusion criteria (2 listed)
- Known placental previa
- Active vaginal bleeding
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
This study is designed to determine number of participants with rupture of membranes from clinical assessment.
Time frame: From hospital presentation on complaint of leaking fluid to delivery estimated to be less than 30 days. (up to 30 days)
The standard of care is to perform a sterile speculum exam and noting the evidence of leakage of fluid from the cervical os, and if necessary, pooling of fluid in the posterior fornix, assessing the fluid with nitrazine/pH and ferning under the microscope. The following chart review criteria will be assessed: Major Criteria * the results of the initial SSE (leaking, pooling, ferning, nitrazine) and any follow-up SSE * the AFI using ultrasound assessment * the number of hours from the initial exam to delivery (<48 hours will be considered suggestive of ROM) * evidence of chorioamnionitis and/or endomyometritis
2 secondary outcomes
Results of AmniSure test.
Time frame: From hospital presentation on complaint of leaking fluid to delivery estimated to be less than 30 days. (up to 30 days)
Results of ROM PLus Test
Time frame: From hospital presentation on complaint of leaking fluid to delivery estimated to be less than 30 days. (up to 30 days)
Results and safety
The study was withdrawn before enrolling participants, so there are no results.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 23 Dec 2013.
Related trials for Pregnant Woman With Premature Rupture of Amnion Membranes
Recruiting
Microbiological and Biochemical Profiling of Amniotic Fluid in Women With Short Cervix or Premature Rupture of Membranes
Short Cervix, PROM, Preterm (Pregnancy)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Dr. M. Rajapaksha, MD study chair
De Soysa Maternity Hospital, Kynsey Road, Colombo 08, Sri Lanka
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Pregnant Woman With Premature Rupture of Amnion Membranes, run by University of Colombo at 1 site in Sri Lanka.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: withdrawn, as of the sponsor's last update on 23 Dec 2013. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Sri Lanka. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was withdrawn before enrolling participants, so there are no results.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
This study is designed to determine number of participants with rupture of membranes from clinical assessment. (time frame: From hospital presentation on complaint of leaking fluid to delivery estimated to be less than 30 days. (up to 30 days)). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Dec 2013.