ENHANCED Device Programming to Reduce Therapies and Improve Quality of Life in Implantable Cardioverter Defibrillator (ICD) Patients

A study testing Enhanced ICD programming in people with Cardiac Arrhythmias, run by M. Meine at 1 site in Netherlands.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The purpose of this study is to determine whether Enhanced device programming to reduce therapies (i.e. anti tachycardia pacing (ATP) episodes and shocks (both appropriate and inappropriate)) is safe for patients implanted with an Implantable Cardioverter-Defibrillator (ICD). Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Cardiac Arrhythmias
What is being tested?
Enhanced ICD programming
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
1 siteNetherlands
Study dates
Apr 2013to Apr 2016
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • a primary or secondary prophylactic indication for ICD therapy according to the current European guidelines
  • implanted with a Medtronic ProtectaTM ICD/CRT-D device or any future CE-approved and market-released Medtronic ICD/CRT-D devices with SmartShock technology
  • between 18-80 years of age
  • speaking and understanding Dutch
  • providing written informed consent

Who cannot join

  • a life expectancy less than 1 year
  • a history of psychiatric illness other than affective/anxiety disorders
  • on the waiting list for heart transplantation
  • insufficient knowledge of the Dutch language

Trial locations and contacts

1 site in 1 country.

Mathias Meine, MD, PhD contact

+31(0)884666184

m.meine@umcutrecht.nl

Susanne S Pedersen, PhD contact

+ 31(0)134662067

s.s.pedersen@uvt.nl

Netherlands1 site, 1 recruiting
  • University Medical Center

    Utrecht, 3508 GA

    Mathias Meine, MD, PhD

    Recruiting

Other trials in Netherlands

About this study

Official title: ENHANCED Device Programming to Reduce Therapies and Improve Quality of Life in Implantable Cardioverter Defibrillator Patients: A Prospective, Single-arm Safety Monitoring Study (ENHANCED-ICD Study)

The purpose of this study is to determine whether Enhanced device programming to reduce therapies (i.e. anti tachycardia pacing (ATP) episodes and shocks (both appropriate and inappropriate)) is safe for patients implanted with an Implantable Cardioverter-Defibrillator (ICD). The secondary objective is to examine the impact of Enhanced programming on (i) ATPs and shocks (both appropriate and inappropriate) and (ii) quality of life and distress.

Read the detailed description

ICD therapy has become the first-line treatment for the prevention of sudden cardiac death both as primary and secondary prevention due to its proven survival benefits as compared to anti-arrhythmic drugs. However, ICD therapy is associated with a number of complications and shocks that may impair patient quality of life and well being but also influence mortality. Hence, reduction of ICD shocks by means of alternative programming of the device is paramount for improving patient-centered outcomes and mortality.

The ENHANCED-ICD study will be a prospective, single-arm safety monitoring study. All patients will receive Enhanced programming. Furthermore, patients will be asked to complete a set of standardized and validated self-report questionnaires prior to ICD implantation, at 3-, 6-, and 12 months post implantation.

Being tested
Enhanced ICD programming
Keywords
Cardiac arrhythmias, Implantable Cardioverter-Defibrillator, Patient Safety, Quality of life
Medical subject headings
Arrhythmias, Cardiac

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Enhanced ICD programmingDevice

    • VT monitor: > 166/min
    • fVT: > 182/min; via VF 60/80 intervals (number of intervals to start ATP after approximately 20 s); 3 x ATP (8 stimuli, 88%, scan 20 ms); shock 1-5: 35 J; redetection 30/40 intervals.
    • VF: > 250/min; via VF 60/80 intervals (number of intervals to start therapy after approximately 15 s); 1 x ATP (8 stimuli, 88%) during charging; all shocks: 35 J; redetection 30/40 intervals
    • SVT/VT discrimination is turned on, high rate time out is "OFF"
    • SVT/VT discrimination single chamber: stability, wavelet; SVT upper rate limit: 222/min
    • SVT/VT discrimination dual/triple chamber: P/R logic, wavelet; SVT upper rate limit: 222/min
    • T wave-oversensing and lead noise discrimination is turned on in all devices.
Study groups in NCT01715116
Study groupRoleWhat they receive
Enhanced ICD programmingExperimentalNot described
Receives: Device: Enhanced ICD programming

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of intervention-related safety events

    Combined safety endpoint: arrhythmic syncope/hospitalization/death/other serious adverse event.

    Measured: up to 12 months

Secondary outcomes (11)
  1. Number of ATPs/shocks

    ATPs/shocks shall be further classified based on: appropriate/inappropriate; successful/unsuccessful.

    Measured: 2 months post implantation

  2. Number of ATPs/shocks

    ATPs/shocks shall be further classified based on: appropriate/inappropriate; successful/unsuccessful.

    Measured: 6 months post implantation

  3. Number of ATPs/shocks

    ATPs/shocks shall be further classified based on: appropriate/inappropriate; successful/unsuccessful.

    Measured: 12 months post implantation

  4. Quality of life

    EuroQol 5D (EQ-5D)and Short Form Health Survey 12 (SF-12)

    Measured: Baseline

  5. Quality of life

    EuroQol 5D (EQ-5D)and Short Form Health Survey 12 (SF-12)

    Measured: 3 months post implantation

  6. Quality of life

    EuroQol 5D (EQ-5D)and Short Form Health Survey 12 (SF-12)

    Measured: 6 months post implantation

  7. Quality of life

    EuroQol 5D (EQ-5D) and Short Form Health Survey 12 (SF-12)

    Measured: 12 months post implantation

  8. Distress

    Hospital Anxiety and Depression Scale (HADS) and Patient Health Questionnaire (PHQ-9)

    Measured: Baseline

  9. Distress

    Hospital Anxiety and Depression Scale (HADS)and Patient Health Questionnaire (PHQ-9)

    Measured: 3 months post implantation

  10. Distress

    Hospital Anxiety and Depression Scale (HADS)and Patient Health Questionnaire (PHQ-9)

    Measured: 6 months post implantation

  11. Distress

    Hospital Anxiety and Depression Scale (HADS)and Patient Health Questionnaire (PHQ-9)

    Measured: 12 months post implantation

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Oct 2012 (estimated)
  2. Study startApr 2013
  3. Primary completionApr 2016 (estimated)
  4. Study completionApr 2016 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
60 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01715116
Sponsor's protocol ID
12/301
Acronym
ENHANCED-ICD
Status last verified
Apr 2013
First submitted
10 Oct 2012
Last updated
17 Apr 2013
Results posted
No
Data monitoring committee
Yes

Publications

  • Chiu CSL, van Dijkhuizen A, Gerrits W, Cramer MJ, Tuinenburg AE, van der Harst P, Meine M. Reducing Unnecessary Implantable Cardioverter-Defibrillator Therapy With ENHANCED Programming: Long-Term Outcomes of the ENHANCED-ICD Study. J Cardiovasc Electrophysiol. 2025 Nov;36(11):2861-2869. doi: 10.1111/jce.70060. Epub 2025 Aug 18.

    PubMed 40820765
  • Mastenbroek MH, Pedersen SS, van der Tweel I, Doevendans PA, Meine M. Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study). Am J Cardiol. 2016 Feb 15;117(4):596-604. doi: 10.1016/j.amjcard.2015.11.052. Epub 2015 Dec 7.

    PubMed 26732419

Questions about this trial

What is this clinical trial studying?

A study testing Enhanced ICD programming in people with Cardiac Arrhythmias, run by M. Meine at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 17 Apr 2013. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Mathias Meine, MD, PhD (+31(0)884666184, m.meine@umcutrecht.nl), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of intervention-related safety events (time frame: up to 12 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01715116, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Apr 2013.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in