Prostate CancerKIM GatingNCT01742403
Continuous Monitoring of Prostate Position During Radiotherapy
A study testing R/T gating kV intrafraction monitoring in people with Prostate Cancer, run by Royal North Shore Hospital at 1 site in Australia.
Trial summary
This study is investigating measurement of prostate motion during radiotherapy using the implanted gold markers. If motion is greater than 3mm then the beam will be stopped and position corrected (gating). Read more about this study
- Who is it for?
- Any age, men only
- Conditions the study is for
- Prostate Cancer
- What is being tested?
- R/T gating kV intrafraction monitoring
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 100 participants
- Where
- 1 siteAustralia
- Study dates
- 1 Jan 2013to 30 Jun 2028
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Any age
- Men only
- No healthy volunteers
- Child, Adult, Older adult
Who may be able to join
- Patients undergoing definitive external beam radiotherapy;
- Histological proven prostate adenocarcinoma
- Prostate Specific Antigen (PSA),within 3 months prior to enrolment
- Patient must be able to have gold fiducial markers placed in the prostate (if on anticoagulants, must be approved for procedure by Cardiologist)
- Artificial hips
- Lymph Node irradiation
Show all 9Show fewer
- Patient Dimensions >40cms
- ECOG 0-2
- Ability to understand and willingness to sign informed consent form.
Who cannot join
- Altered fractionation
- Fiducials must be no less than 1cm apart
Trial locations and contacts
1 site in 1 country.
Australia1 site
Department of Radiation Oncology, Northern Sydney Cancer Centre
St Leonards, New South Wales, 2065
About this study
Official title: Phase I Feasibility Study of Prostate Cancer Radiotherapy Gating Using kV Intrafraction Monitoring (KIM)
This study is investigating measurement of prostate motion during radiotherapy using the implanted gold markers. If motion is greater than 3mm then the beam will be stopped and position corrected (gating).
Read the detailed description
Prostate cancer now accounts for one third of all new cancer diagnoses in men and approximately 30% of men will have external beam radiotherapy as their primary local therapy. Prostate motion during radiotherapy can be divided into interfraction and intrafraction motion. Interfraction motion has been well established and has been largely overcome by daily online image verification with either ultrasound, online CT or implanted fiducial markers, however motion during the radiation beam on time (intrafraction motion) is not corrected and can be the cause of significant errors in radiation dose delivery.
Intrafraction motion: Movement of the prostate after initial treatment setup has been termed intrafraction motion. Estimates of the magnitude and frequency of this motion were initially made using continuous Magnetic Resonance (MR) imaging. Padhani et al reported 16% of patients had > 5mm anterior:posterior motion when imaged for 7 minutes with similar results reported in subsequent MR cine studies, Intrafraction motion can be secondary to organ motion such as bladder filling, respiration or moving rectal gas, or can be due to physical patient motion. With the availability of real-time prostate tracking, clinical data is available to quantify the magnitude and frequency of motion. An early report from Kupelian et al using continuous radiotransponder positioning7 described 41% of fractions with >3mm of motion and 15% > 5mm of motion for > 30 seconds. The risk of motion was noted to increase with longer treatment time.
Our own data using offline autosegmentation of the fiducial marker position of 10 patients showed 38% of fractions >1mm, 4.7% of fractions >3mm and 1.7% of fractions >5mm instantaneously during treatment delivery of approximately 2.5 min 8.
Significance of correcting for motion:
If radiation dose is recalculated for each individual fraction and adjusted for intrafraction motion it is possible to estimate the real dose delivered to the target and compare this to the desired dose. This comparison gives a robust model of the potential benefit for real- time tracking and adjustment for the motion. Overview of kilovoltage intrafraction monitoring (KIM): Kilovoltage intrafraction monitoring is a novel real-time tumour localisation modality. It involves a single gantry- mounted kV x-ray imager (which is widely available on most linacs) acquiring 2D projections of implanted fiducial markers. As the treatment gantry rotates around the patient during treatment , the kV imager acquires 2D projections of the prostate . The fiducial markers are segmented using an in-house developed software package. 3D positions are determined via maximum likelihood estimation (MLE) of a 3D probability density.
In previous work (Ng et al, 2012) we have applied the KIM method with offline segmentation to calculate the 3D prostate trajectory after treatment. In the present study we are utilising online marker segmentation to enable live trajectory creation during treatment delivery with a processing time less than 1 second. With the circa real-time trajectories we are able to gate the delivery so to maximise dose to the tumour, or track with Multi-Leaf Collimators (MLC) to follow the prostate motion. The latter involves complex interaction with the beam delivery system and is not part of this study. The treatment can be gated based on a pre-set tolerance. Using our earlier data we modelled several gating criteria 3mm/5s, 3mm/10s and 3mm/15s based on excursions along individual axes and also the radial excursion. Across the 10 patients, a tolerance of 3mm/5s was shown to be efficient, introducing only 24 gating events (from 268 treatments) and safe, with the smallest time for excursion (5s).
The KIM method does introduce extra radiation dose to the patient of approximately 65mSv per treatment localised to the prostate 8. Standard treatment doses for prostate radiotherapy are 80 Gy. The amount of imaging dose will be dependent on the imaging field size, frame rate of acquired images, treatment field size, kV energy used and method of treatment delivery (Volumetric Modulated Arc Therapy [VMAT], Intensity Modulated Radiotherapy [IMRT], Stereotactic Boost Radiotherapy [SBRT]).9 We will minimise the imaging dose from our previous study 8 by:
- reducing the field size to encompass only the fiducials and a small margin per patient so that the imaging dose is delivered inside the treatment volume (expect 20-40% dose saving);
- the beam quality is maximised to 125 kV;
- patient dimensions are limited as the larger patients create more scatter radiation (that decreases image quality) and absorb more radiation. This, combined with treatment field size as below, may allow us to use a lower frame rate for image acquisition, down from 10 fps to 5 fps, which will have a proportional effect on dose;
- patients with nodal areas for treatment are excluded as the treatment fields are larger and this reduces image quality. By excluding these larger patients we may be able to use 5fps rather than 10 fps imaging combined with the patient dimension as above;
- VMAT is shown to require less treatment time than IMRT delivery, and SBRT is shown to require less total time than conventional fractionation (where total treatment time is proportional to imaging dose). We expect to see a dose reduction with the VMAT-SBRT protocol compared to VMAT of 20-40%.
Together with the imaging dose, we need to consider and weight the gains from intrafraction monitoring and gated treatment. These gains include improving the accuracy of delivered dose, so that the planned treatment dose is delivered efficiently to the tumour, and the geometric accuracy that would allow reduction in the safety margin introduced to compensate for treatment. We have demonstrated significant improvements in tumour dose from 60% to 95% of the intended dose distribution by gating with 3mm/5s tolerance as shown in Figure 1.
Verification of KIM clinical dynamic localization accuracy using kV/MV triangulation:
In order to evaluate the dynamic localisation accuracy of the KIM method, 3D positions determined by KIM can be compared to kV/MV triangulation. kV/MV triangulation. Triangulation provides an independent measure of the prostate location.
Failure Mode and Effects Analysis (FMEA) and Quality Assurance (QA) protocol An FMEA has been performed identifying potential failure modes within the additional KIM workflow. The standard workflow has established quality assurance measures in place. All KIM failure modes have been mitigated in numerous layers by quality assurance measures, clear design of user interface, clear designation of staff roles, staff education, and exclusion criteria for patient selection.
- Conditions
- Prostate Cancer
- Being tested
- R/T gating kV intrafraction monitoring
- Keywords
- Prostate, IGRT, VMAT
- Medical subject headings
- Prostatic Neoplasms
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
R/T gating kV intrafraction monitoringRadiation
This is a Phase I Pilot study to assess the feasibility of implementing prostate radiotherapy gating using kV intrafraction monitoring.
| Study group | Role | What they receive |
|---|---|---|
| R/T gating kV intrafraction monitoring | Experimental | Intervention: Recruitment will be performed in 2 phases:
Phase I will include the first 10 patients. All patients will be treated on a standard fractionation protocol with 40 fractions. This will allow 400 potential fractions to be auto-segmented in real time. Once Phase I is successfully completed we will aim to continue recruitment of a further 20 patients as Phase II. For this phase we will open recruitment to patients with lymph node positivity, hypofractionation (as per Department protocols) and intermittent imaging (imaging less frequently than every fraction). Receives: Radiation: R/T gating kV intrafraction monitoring |
What is being measured
The primary outcome is the main question the study is designed to answer.
Feasibility of KIM techique
Technique will be determined as feasible if 90% of treatment fractions are successfully segmented in real time.
Measured: 10 years
Secondary outcomes (1)
Time for procedure
Measurement of time taken to perform KIM gating to guide future department resource questions.
Measured: 10 years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted5 Dec 2012 (estimated)
- Study start1 Jan 2013
- Primary completion30 Jun 2028 (estimated)
- Study completion30 Jun 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Prostate CancerStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 100 participants (actual)
Sponsor and investigators
- Lead sponsor
- Royal North Shore Hospital
- Sponsor type
- University, hospital or other
- Collaborators
- Northern Sydney and Central Coast Area Health Service
- Responsible party
- Sponsor
- Investigators
- Thomas Eade, MBBS, Principal investigator, Royal North Shore Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01742403
- Sponsor's protocol ID
- 12-NSCCRO-P001
- Acronym
- KIM Gating
- Status last verified
- Feb 2026
- First submitted
- 2 Dec 2012
- Last updated
- 6 Feb 2026
- Results posted
- No
- Data monitoring committee
- No
- Individual data sharing
- Yes: With other ethics approved centres using annonymised data.
Publications
Keall PJ, Aun Ng J, O'Brien R, Colvill E, Huang CY, Rugaard Poulsen P, Fledelius W, Juneja P, Simpson E, Bell L, Alfieri F, Eade T, Kneebone A, Booth JT. The first clinical treatment with kilovoltage intrafraction monitoring (KIM): a real-time image guidance method. Med Phys. 2015 Jan;42(1):354-8. doi: 10.1118/1.4904023.
PubMed 25563275Ng JA, Booth JT, O'Brien RT, Colvill E, Huang CY, Poulsen PR, Keall PJ. Quality assurance for the clinical implementation of kilovoltage intrafraction monitoring for prostate cancer VMAT. Med Phys. 2014 Nov;41(11):111712. doi: 10.1118/1.4898119.
PubMed 25370626
Study at a glance
From the registry record, last updated by the sponsor on 6 Feb 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Phase I Feasibility Study of Prostate Cancer Radiotherapy Gating Using kV Intrafraction Monitoring (KIM)
- ClinicalTrials.gov ID
- NCT01742403
- Acronym / sponsor ID
- KIM Gating / 12-NSCCRO-P001
- Conditions
- Prostate Cancer
- Keywords
- Prostate, IGRT, VMAT
- Study type
- Interventional
- Recruitment status
- Active, not recruiting
- Enrolment
- 100 participants (actual)
- Lead sponsor
- Royal North Shore HospitalUniversity, hospital or other
- Collaborators
- Northern Sydney and Central Coast Area Health Service
- Study start
- 1 Jan 2013 (actual)
- Primary completion
- 30 Jun 2028 (estimated)
- Study completion
- 30 Jun 2028 (estimated)
- First posted
- 5 Dec 2012 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study is investigating measurement of prostate motion during radiotherapy using the implanted gold markers. If motion is greater than 3mm then the beam will be stopped and position corrected (gating).
Detailed description
Prostate cancer now accounts for one third of all new cancer diagnoses in men and approximately 30% of men will have external beam radiotherapy as their primary local therapy. Prostate motion during radiotherapy can be divided into interfraction and intrafraction motion. Interfraction motion has been well established and has been largely overcome by daily online image verification with either ultrasound, online CT or implanted fiducial markers, however motion during the radiation beam on time (intrafraction motion) is not corrected and can be the cause of significant errors in radiation dose delivery.
Intrafraction motion: Movement of the prostate after initial treatment setup has been termed intrafraction motion. Estimates of the magnitude and frequency of this motion were initially made using continuous Magnetic Resonance (MR) imaging. Padhani et al reported 16% of patients had > 5mm anterior:posterior motion when imaged for 7 minutes with similar results reported in subsequent MR cine studies, Intrafraction motion can be secondary to organ motion such as bladder filling, respiration or moving rectal gas, or can be due to physical patient motion. With the availability of real-time prostate tracking, clinical data is available to quantify the magnitude and frequency of motion. An early report from Kupelian et al using continuous radiotransponder positioning7 described 41% of fractions with >3mm of motion and 15% > 5mm of motion for > 30 seconds. The risk of motion was noted to increase with longer treatment time.
Our own data using offline autosegmentation of the fiducial marker position of 10 patients showed 38% of fractions >1mm, 4.7% of fractions >3mm and 1.7% of fractions >5mm instantaneously during treatment delivery of approximately 2.5 min 8.
Significance of correcting for motion:
If radiation dose is recalculated for each individual fraction and adjusted for intrafraction motion it is possible to estimate the real dose delivered to the target and compare this to the desired dose. This comparison gives a robust model of the potential benefit for real- time tracking and adjustment for the motion. Overview of kilovoltage intrafraction monitoring (KIM): Kilovoltage intrafraction monitoring is a novel real-time tumour localisation modality. It involves a single gantry- mounted kV x-ray imager (which is widely available on most linacs) acquiring 2D projections of implanted fiducial markers. As the treatment gantry rotates around the patient during treatment , the kV imager acquires 2D projections of the prostate . The fiducial markers are segmented using an in-house developed software package. 3D positions are determined via maximum likelihood estimation (MLE) of a 3D probability density.
In previous work (Ng et al, 2012) we have applied the KIM method with offline segmentation to calculate the 3D prostate trajectory after treatment. In the present study we are utilising online marker segmentation to enable live trajectory creation during treatment delivery with a processing time less than 1 second. With the circa real-time trajectories we are able to gate the delivery so to maximise dose to the tumour, or track with Multi-Leaf Collimators (MLC) to follow the prostate motion. The latter involves complex interaction with the beam delivery system and is not part of this study. The treatment can be gated based on a pre-set tolerance. Using our earlier data we modelled several gating criteria 3mm/5s, 3mm/10s and 3mm/15s based on excursions along individual axes and also the radial excursion. Across the 10 patients, a tolerance of 3mm/5s was shown to be efficient, introducing only 24 gating events (from 268 treatments) and safe, with the smallest time for excursion (5s).
The KIM method does introduce extra radiation dose to the patient of approximately 65mSv per treatment localised to the prostate 8. Standard treatment doses for prostate radiotherapy are 80 Gy. The amount of imaging dose will be dependent on the imaging field size, frame rate of acquired images, treatment field size, kV energy used and method of treatment delivery (Volumetric Modulated Arc Therapy [VMAT], Intensity Modulated Radiotherapy [IMRT], Stereotactic Boost Radiotherapy [SBRT]).9 We will minimise the imaging dose from our previous study 8 by:
- reducing the field size to encompass only the fiducials and a small margin per patient so that the imaging dose is delivered inside the treatment volume (expect 20-40% dose saving);
- the beam quality is maximised to 125 kV;
- patient dimensions are limited as the larger patients create more scatter radiation (that decreases image quality) and absorb more radiation. This, combined with treatment field size as below, may allow us to use a lower frame rate for image acquisition, down from 10 fps to 5 fps, which will have a proportional effect on dose;
- patients with nodal areas for treatment are excluded as the treatment fields are larger and this reduces image quality. By excluding these larger patients we may be able to use 5fps rather than 10 fps imaging combined with the patient dimension as above;
- VMAT is shown to require less treatment time than IMRT delivery, and SBRT is shown to require less total time than conventional fractionation (where total treatment time is proportional to imaging dose). We expect to see a dose reduction with the VMAT-SBRT protocol compared to VMAT of 20-40%.
Together with the imaging dose, we need to consider and weight the gains from intrafraction monitoring and gated treatment. These gains include improving the accuracy of delivered dose, so that the planned treatment dose is delivered efficiently to the tumour, and the geometric accuracy that would allow reduction in the safety margin introduced to compensate for treatment. We have demonstrated significant improvements in tumour dose from 60% to 95% of the intended dose distribution by gating with 3mm/5s tolerance as shown in Figure 1.
Verification of KIM clinical dynamic localization accuracy using kV/MV triangulation:
In order to evaluate the dynamic localisation accuracy of the KIM method, 3D positions determined by KIM can be compared to kV/MV triangulation. kV/MV triangulation. Triangulation provides an independent measure of the prostate location.
Failure Mode and Effects Analysis (FMEA) and Quality Assurance (QA) protocol An FMEA has been performed identifying potential failure modes within the additional KIM workflow. The standard workflow has established quality assurance measures in place. All KIM failure modes have been mitigated in numerous layers by quality assurance measures, clear design of user interface, clear designation of staff roles, staff education, and exclusion criteria for patient selection.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| R/T gating kV intrafraction monitoring | Experimental | Radiation: R/T gating kV intrafraction monitoringIntervention: Recruitment will be performed in 2 phases: Phase I will include the first 10 patients. All patients will be treated on a standard fractionation protocol with 40 fractions. This will allow 400 potential fractions to be auto-segmented in real time. Once Phase I is successfully completed we will aim to continue recruitment of a further 20 patients as Phase II. For this phase we will open recruitment to patients with lymph node positivity, hypofractionation (as per Department protocols) and intermittent imaging (imaging less frequently than every fraction). |
Who may qualify
- Sex
- Male only
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
Key inclusion criteria (9 listed)
- Patients undergoing definitive external beam radiotherapy;
- Histological proven prostate adenocarcinoma
- Prostate Specific Antigen (PSA),within 3 months prior to enrolment
- Patient must be able to have gold fiducial markers placed in the prostate (if on anticoagulants, must be approved for procedure by Cardiologist)
- Artificial hips
Key exclusion criteria (2 listed)
- Altered fractionation
- Fiducials must be no less than 1cm apart
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| R/T gating kV intrafraction monitoringThis is a Phase I Pilot study to assess the feasibility of implementing prostate radiotherapy gating using kV intrafraction monitoring. | Radiation | R/T gating kV intrafraction monitoring |
Primary outcome
Feasibility of KIM techique
Time frame: 10 years
Technique will be determined as feasible if 90% of treatment fractions are successfully segmented in real time.
1 secondary outcome
Time for procedure
Time frame: 10 years
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 Feb 2026.
- Results publication: PubMed 25563275Keall PJ, Aun Ng J, O'Brien R, Colvill E, Huang CY, Rugaard Poulsen P, Fledelius W, Juneja P, Simpson E, Bell L, Alfieri F, Eade T, Kneebone A, Booth JT. The first clinical treatment with kilovoltage intrafraction monitoring (KIM): a real-time image guidance method. Med Phys. 2015 Jan;42(1):354-8. doi: 10.1118/1.4904023.
- Results publication: PubMed 25370626Ng JA, Booth JT, O'Brien RT, Colvill E, Huang CY, Poulsen PR, Keall PJ. Quality assurance for the clinical implementation of kilovoltage intrafraction monitoring for prostate cancer VMAT. Med Phys. 2014 Nov;41(11):111712. doi: 10.1118/1.4898119.
- Individual participant dataSharing planned: Yes. With other ethics approved centres using annonymised data.
Related trials for Prostate Cancer
Active, not recruiting
Streamlined Geriatric and Oncological Evaluation Based On IC Technology
Breast Cancer, Comorbidities and Coexisting Conditions
Active, not recruitingObservational study
MRI Fusion Biopsy vs. Micro-Ultrasound Guided Biopsy
Prostate Cancer
Enrolling by invitationObservational study
Natural History Study of Early Life Exposures in Agriculture (ELEA)
Prostate Cancer, Leukemia
Not yet recruitingPhase 1/2
STAR0602 With Nivolumab in Non Small Cell Lung Cancer and in Metastatic Castrate-Resistant Prostate Cancer, and STAR0602 Alone in Thymic Carcinoma
NSCLC, Non-Small Cell Lung Cancer
Recruiting
Rehabilitation and Sex Therapy to Optimize Recovery After Prostate Cancer Treatment
Prostate Cancer, Urinary Incontinence
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Thomas Eade, MBBS principal investigator
Royal North Shore Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing R/T gating kV intrafraction monitoring in people with Prostate Cancer, run by Royal North Shore Hospital at 1 site in Australia.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 9 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: under way, not looking for participants, as of the sponsor's last update on 6 Feb 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Australia. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Feasibility of KIM techique (time frame: 10 years). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01742403, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Feb 2026.