Aortic Aneurysm, ThoracoabdominalSTRATONCT01756911
Evaluation of the Safety and Efficacy of the Multilayer Stent
A study testing MFM in people with Aortic Aneurysm, Thoracoabdominal and Thoracoabdominal Aortic Aneurysm, run by Cardiatis at 9 sites in France.
Trial summary
Evaluation of the Multilayer Flow Modulator (MFM) for Endovascular Thoracoabdominal Aneurysm Repair. The objectives of the study is to determine the efficacy, safety and performance of the MFM and its delivery system in patients at high surgical risk presenting with a type II, III thoracoabdominal aneurysm, below the… Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Aortic Aneurysm, Thoracoabdominal, Thoracoabdominal Aortic Aneurysm, Aortic Aneurysm, Thoracic
- What is being tested?
- MFM
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 23 participants
- Where
- 9 sitesFrance
- Study dates
- Mar 2010to Apr 2012
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age >18 years
- Life expectancy ≥ 12 months
- The patient or his legal representative has signed the informed consent form
- Thoracoabdominal aneurysm type 2 or 3 with vital collaterals and requiring intervention to prevent its rupture according to the criteria defined by consensus ("Expert Consensus Document on the Treatment of Descending Thoracic Aortic Disease Using Endovascular Stent-Grafts", Ann Thorac Surg 2008;85:S1-41)
- Contraindicated for open surgery, declared inoperable by the surgeon and anesthetist (statement signed by each doctor) and must have at least one of the following:
- Age > 80 years
Show all 21Show fewer
- ASA (American Society of Anesthesiologists) score ≥ 3
- History of thoracic surgery or surgery of the abdominal aorta
- Coronary artery disease (history of angina or myocardial infarction) with positive functional testing and coronary lesions for which revascularization is impossible or not indicated
- Heart failure
- Inoperable aortic stenosis
- LVEF (Left Ventricular Ejection Fraction) <40%;
- chronic respiratory failure defined by one of the following criteria:
- FEV (Forced expiratory volume) <1.2 l / sec;
- VC (Vital Capacity) <50% of the predicted value according to age, sex and weight;
- arterial blood gas analysis in the absence of oxygen: PaCO2 (Pression artérielle en CO2) > 45 mmHg or PaO2 (Pression artérielle en O2) <60 mmHg
- Oxygen therapy
- renal insufficiency if creatininaemia> 200 micromol / l before injection of contrast product;
- hostile abdomen, including presence of ascites or other signs of portal hypertension;
- obesity.
- adequate arterial anatomy of aneurismal lesion access.
Who cannot join
- medical contraindications to a local or general anesthesia and angiography;
- Life expectancy less than one year, or clinical follow-up impossible;
- congenital disorders of blood coagulation;
- intercurrent infection;
- allergy to aspirin, clopidogrel, or contrast agents;
- patient(s) included in another clinical study;
- patient pregnant or breastfeeding
Trial locations and contacts
9 sites in 1 country.
9 sites in 1 country
France9 sites
Hopital Jean Minjoz
Besançon, 25030
Hopital Neurocardiologique
Bron, 69677
Centre Hospitalier de La Région D'Annecy
Metz-Tessy, 74370
Chu Brabois Nancy
Nancy, 54511
Hopital Europeen Georges-Pompidou
Paris, 75015
Pitie-Salpetriere
Paris, 75651
CMC Parly II
Paris, 78150
Institut Cardio-Vasculaire Paris Sud Hôpital Claude Galien À Quincy
Quincy-sous-Sénart, 91480
Hopital Universitaire Rangueil
Toulouse, 31059
About this study
Official title: Evaluation du Stent Multicouches Dans le Traitement Des anévrismes de l'Aorte Thoraco-abdominale
Evaluation of the Multilayer Flow Modulator (MFM) for Endovascular Thoracoabdominal Aneurysm Repair.
The objectives of the study is to determine the efficacy, safety and performance of the MFM and its delivery system in patients at high surgical risk presenting with a type II, III thoracoabdominal aneurysm, below the left subclavian and above the iliac bifurcation, according to the Crawford classification.
Read the detailed description
Conventional treatments of thoracoabdominal aneurysm are medical treatments (based on hypertension control) on one hand and surgical treatment on the other hand.
The standard treatment is surgery consisting of an exclusion of the aneurysm with restoration of continuity by means of a prosthesis usually made of Dacron.
- The rates of surgical morbidity and mortality differ according to whether the patient is treated electively or in an emergency setting. The most feared complication is spinal cord ischemia inducing paraplegia.
- In elective surgery, operative mortality is estimated to be between 6% and 15% depending on the series, and around 50% to 60% of patients are treated in an emergency setting. The rate of neurological complications such as paraparesis or paraplegia is estimated to be between 3% and 15%.
- In addition to the above, the following major complications have been shown to have an impact on the morbidity of this major surgery (5% each):
- Bleeding requiring surgical hemostasis
- Respiratory distress syndrome requiring prolonged ventilation support
- Acute renal failure
- Infections
- Central neurological events (stroke and coma)
- Peripheral neurological events (sensory-motor deficits, paraparesis, paraplegia)
Analyses identify risk factors increasing the morbidity and mortality:
- Patients over 80 years
- Chronic obstructive pulmonary disease
- Renal failure
- Coronary artery disease
- Comorbidities (malignancy, etc.)
Compared to surgery, endovascular stenting reduces:
- Pulmonary morbidity (suppression of thoracotomy and ventilation), in patients with impaired lung function;
- Renal dysfunction;
- Myocardial failure;
- Risk of spinal cord ischemia and paraplegia.
However, this treatment has a number of limitations
- Availability of device in case of emergency
- Topography of the neck must be far enough from the left subclavian artery to allow satisfactory fixation of the stent and exclusion of the lesion;
- Obstruction of the branches near the aneurysm.
In the current available treatment for this pathology, there are still some disadvantages such as the difficulty of precise positioning of the prosthesis and its branches which must cover the aneurysm tissue without endoleaks. Each lesion having anatomical specificities, the device must be designed for each individual patient, and the operator's technical ability must be extreme. So, the current technique is difficult to reproduce, and any emergency treatment is impossible.
The multilayer flow modulator (non-covered) is the device used in this trial The complications mentioned above are inherent in the concept of covered stent treatment plus endoleaks that continues to fuel the aneurismal sac untreated, thus subject to the persistent risk of rupture. With this technique, the visceral arteries are occluded or have a retrograde flow (which pressurizes the aneurysm again).
The multilayer flow modulator (non-covered) treatment approach avoids the major problems mentioned above:
- It allows the aneurismal sac to thrombose whilst maintaining the patency of collateral branches arising from the aneurysm;
- It improves the flow in the collateral branches, which becomes laminar flow through a mechanism of hemodynamic pressure drop from layer to layer and an increase in speed by rolling;
- Deployment is easier and it is not different from peripheral stent deployment;
- The device is available in all sizes and all lengths that can be stored, allowing the management of emergencies.
The space-age 3D geometrical design of a Cardiatis multilayer flow modulator modifies flow within the aorta in a way that reduces pressure within the aneurysm thus collapsing the aneurismal sac while preserving any vital collateral circulation.
- Conditions
- Aortic Aneurysm, Thoracoabdominal, Thoracoabdominal Aortic Aneurysm, Aortic Aneurysm, Thoracic
- Being tested
- MFM
- Keywords
- MFM, Multilayer Flow Modulator, Multilayer stent, Thoracoabdominal Aortic Aneurysm
- Medical subject headings
- Aortic Aneurysm, Thoracoabdominal, Aortic Aneurysm, Thoracic
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
MFMDevice
Also called Multilayer Flow Modulator, Multilayer stent
Implantation of the MFM
| Study group | Role | What they receive |
|---|---|---|
| Thotaco-abdominal aneurysm | Experimental | MFM Receives: Device: MFM |
What is being measured
The primary outcome is the main question the study is designed to answer.
Number of patients with aneurysm exclusion
Measured: 12 months
Secondary outcomes (2)
Number of covered branches permeable
Measured: 12 months
Number of patients with Serious Adverse Events
Measured: 12 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted28 Dec 2012 (estimated)
- Study startMar 2010
- Primary completionApr 2012
- Study completionApr 2012
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Aortic Aneurysm, ThoracoabdominalStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 23 participants (actual)
Sponsor and investigators
- Lead sponsor
- Cardiatis
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Jean-Noël Fabiani, Pr, Principal investigator, HEGP
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01756911
- Sponsor's protocol ID
- IC_0308_FRA
- Other IDs
- 2009-013678-42, 2009
- Acronym
- STRATO
- Status last verified
- Apr 2014
- First submitted
- 14 Dec 2012
- Last updated
- 14 Apr 2014
- Results posted
- No
- Data monitoring committee
- Yes
Publications
Vaislic CD, Fabiani JN, Chocron S, Robin J, Costache VS, Villemot JP, Alsac JM, Leprince PN, Unterseeh T, Portocarrero E, Glock Y, Rousseau H; STRATO Investigators Group. One-year outcomes following repair of thoracoabdominal aneurysms with the multilayer flow modulator: report from the STRATO trial. J Endovasc Ther. 2014 Feb;21(1):85-95. doi: 10.1583/13-4553R.1.
PubMed 24502488Vaislic CD, Fabiani JN, Chocron S, Robin J, Costache VS, Villemot JP, Alsac JM, Leprince PN, Unterseeh T, Portocarrero E, Glock Y, Rousseau H; STRATO Investigators Group. Three-Year Outcomes With the Multilayer Flow Modulator for Repair of Thoracoabdominal Aneurysms: A Follow-up Report From the STRATO Trial. J Endovasc Ther. 2016 Oct;23(5):762-72. doi: 10.1177/1526602816653095. Epub 2016 Jun 8.
PubMed 27280802
Study at a glance
From the registry record, last updated by the sponsor on 14 Apr 2014. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation du Stent Multicouches Dans le Traitement Des anévrismes de l'Aorte Thoraco-abdominale
- ClinicalTrials.gov ID
- NCT01756911
- Acronym / sponsor ID
- STRATO / IC_0308_FRA
- Conditions
- Aortic Aneurysm, Thoracoabdominal, Thoracoabdominal Aortic Aneurysm, Aortic Aneurysm, Thoracic
- Keywords
- MFM, Multilayer Flow Modulator, Multilayer stent, Thoracoabdominal Aortic Aneurysm
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 23 participants (actual)
- Lead sponsor
- CardiatisIndustry (pharma, biotech, devices)
- Study start
- Mar 2010
- Primary completion
- Apr 2012 (actual)
- Study completion
- Apr 2012 (actual)
- First posted
- 28 Dec 2012 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Evaluation of the Multilayer Flow Modulator (MFM) for Endovascular Thoracoabdominal Aneurysm Repair.
The objectives of the study is to determine the efficacy, safety and performance of the MFM and its delivery system in patients at high surgical risk presenting with a type II, III thoracoabdominal aneurysm, below the left subclavian and above the iliac bifurcation, according to the Crawford classification.
Detailed description
Conventional treatments of thoracoabdominal aneurysm are medical treatments (based on hypertension control) on one hand and surgical treatment on the other hand.
The standard treatment is surgery consisting of an exclusion of the aneurysm with restoration of continuity by means of a prosthesis usually made of Dacron.
- The rates of surgical morbidity and mortality differ according to whether the patient is treated electively or in an emergency setting. The most feared complication is spinal cord ischemia inducing paraplegia.
- In elective surgery, operative mortality is estimated to be between 6% and 15% depending on the series, and around 50% to 60% of patients are treated in an emergency setting. The rate of neurological complications such as paraparesis or paraplegia is estimated to be between 3% and 15%.
- In addition to the above, the following major complications have been shown to have an impact on the morbidity of this major surgery (5% each):
- Bleeding requiring surgical hemostasis
- Respiratory distress syndrome requiring prolonged ventilation support
- Acute renal failure
- Infections
- Central neurological events (stroke and coma)
- Peripheral neurological events (sensory-motor deficits, paraparesis, paraplegia)
Analyses identify risk factors increasing the morbidity and mortality:
- Patients over 80 years
- Chronic obstructive pulmonary disease
- Renal failure
- Coronary artery disease
- Comorbidities (malignancy, etc.)
Compared to surgery, endovascular stenting reduces:
- Pulmonary morbidity (suppression of thoracotomy and ventilation), in patients with impaired lung function;
- Renal dysfunction;
- Myocardial failure;
- Risk of spinal cord ischemia and paraplegia.
However, this treatment has a number of limitations
- Availability of device in case of emergency
- Topography of the neck must be far enough from the left subclavian artery to allow satisfactory fixation of the stent and exclusion of the lesion;
- Obstruction of the branches near the aneurysm.
In the current available treatment for this pathology, there are still some disadvantages such as the difficulty of precise positioning of the prosthesis and its branches which must cover the aneurysm tissue without endoleaks. Each lesion having anatomical specificities, the device must be designed for each individual patient, and the operator's technical ability must be extreme. So, the current technique is difficult to reproduce, and any emergency treatment is impossible.
The multilayer flow modulator (non-covered) is the device used in this trial The complications mentioned above are inherent in the concept of covered stent treatment plus endoleaks that continues to fuel the aneurismal sac untreated, thus subject to the persistent risk of rupture. With this technique, the visceral arteries are occluded or have a retrograde flow (which pressurizes the aneurysm again).
The multilayer flow modulator (non-covered) treatment approach avoids the major problems mentioned above:
- It allows the aneurismal sac to thrombose whilst maintaining the patency of collateral branches arising from the aneurysm;
- It improves the flow in the collateral branches, which becomes laminar flow through a mechanism of hemodynamic pressure drop from layer to layer and an increase in speed by rolling;
- Deployment is easier and it is not different from peripheral stent deployment;
- The device is available in all sizes and all lengths that can be stored, allowing the management of emergencies.
The space-age 3D geometrical design of a Cardiatis multilayer flow modulator modifies flow within the aorta in a way that reduces pressure within the aneurysm thus collapsing the aneurismal sac while preserving any vital collateral circulation.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Thotaco-abdominal aneurysm | Experimental | Device: MFMMFM |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (21 listed)
- Age >18 years
- Life expectancy ≥ 12 months
- The patient or his legal representative has signed the informed consent form
- Thoracoabdominal aneurysm type 2 or 3 with vital collaterals and requiring intervention to prevent its rupture according to the criteria defined by consensus ("Expert Consensus Document on the Treatment of Descending Thoracic Aortic Disease Using Endovascular Stent-Grafts", Ann Thorac Surg 2008;85:S1-41)
- Contraindicated for open surgery, declared inoperable by the surgeon and anesthetist (statement signed by each doctor) and must have at least one of the following:
Key exclusion criteria (7 listed)
- medical contraindications to a local or general anesthesia and angiography;
- Life expectancy less than one year, or clinical follow-up impossible;
- congenital disorders of blood coagulation;
- intercurrent infection;
- allergy to aspirin, clopidogrel, or contrast agents;
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| MFMAlso: Multilayer Flow Modulator, Multilayer stentImplantation of the MFM | Device | Thotaco-abdominal aneurysm |
Primary outcome
Number of patients with aneurysm exclusion
Time frame: 12 months
2 secondary outcomes
Number of covered branches permeable
Time frame: 12 months
Number of patients with Serious Adverse Events
Time frame: 12 months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 14 Apr 2014.
- Results publication: PubMed 24502488Vaislic CD, Fabiani JN, Chocron S, Robin J, Costache VS, Villemot JP, Alsac JM, Leprince PN, Unterseeh T, Portocarrero E, Glock Y, Rousseau H; STRATO Investigators Group. One-year outcomes following repair of thoracoabdominal aneurysms with the multilayer flow modulator: report from the STRATO trial. J Endovasc Ther. 2014 Feb;21(1):85-95. doi: 10.1583/13-4553R.1.
- Derived from this study: PubMed 27280802Vaislic CD, Fabiani JN, Chocron S, Robin J, Costache VS, Villemot JP, Alsac JM, Leprince PN, Unterseeh T, Portocarrero E, Glock Y, Rousseau H; STRATO Investigators Group. Three-Year Outcomes With the Multilayer Flow Modulator for Repair of Thoracoabdominal Aneurysms: A Follow-up Report From the STRATO Trial. J Endovasc Ther. 2016 Oct;23(5):762-72. doi: 10.1177/1526602816653095. Epub 2016 Jun 8.
- One-year outcomes following repair of thoracoabdominal aneurysms with the multilayer flow modulator: report from the STRATO trialLink provided by the sponsor.
Related trials for Aortic Aneurysm, Thoracoabdominal
RecruitingPhase 4
Effect of Remimazolam Versus Propofol Total Intravenous Anesthesia on Intraoperative Hemodynamic Stability in Patients Undergoing Thoracic or Abdominal Endovascular Aortic Repair
Aortic Aneurysm, Thoracoabdominal, Aortic Aneurysm, Abdominal
Not yet recruitingObservational study
Real-World Data Collection of GORE Devices Used In the Endovascular Treatment of Aortic Aneurysms Which Incorporate Visceral Arteries.
Complex Aortic Aneurysms, Thoracoabdominal Aneurysm
Enrolling by invitation
Endovascular Treatment of Thoracic Aortic Disease
Thoracic Aortic Aneurysms, Dissecting, Aneurysm
Recruiting
PMEG for Repair of Pararenal and Thoracoabdominal Aortic Aneurysm
Pararenal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm
Recruiting
Clinical Trial of BAO-G Technique in Complex Aortic Aneurysm Endovascular Repair (BAO-G-02)
Thoracoabdominal Aortic Aneurysm, Endovascular Repair
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Jean-Noël Fabiani, Pr principal investigator
HEGP
9 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing MFM in people with Aortic Aneurysm, Thoracoabdominal and Thoracoabdominal Aortic Aneurysm, run by Cardiatis at 9 sites in France.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 21 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 14 Apr 2014. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 9 sites in France. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Number of patients with aneurysm exclusion (time frame: 12 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01756911, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Apr 2014.