Coronary Artery DiseaseBIOHELIX-IINCT01811927
The Treatment of Coronary Artery Lesions Using the PRO-Kinetic Energy Cobalt-Chromium, Bare-Metal Stent
A study testing PRO-Kinetic Energy Stent in people with Coronary Artery Disease, run by Biotronik AG at 3 sites in 2 countries.
Trial summary
The purpose of this study is to the assess the clinical performance of the BIOTRONIK PRO-Kinetic Energy stent in subjects with atherosclerotic disease of native coronary arteries. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Coronary Artery Disease
- What is being tested?
- PRO-Kinetic Energy Stent
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 43 participants
- Where
- 3 sitesin 2 countries
- Study dates
- Mar 2013to Oct 2014
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age > or = 18 years
- Willingness to comply with study follow-up requirements
- Candidate for a PCI procedure
- Candidate for coronary artery bypass graft surgery
- Documented evidence of stable or unstable angina pectoris or positive functional ischemia study (e.g. exercise treadmill test, thallium stress test, SPECT, stress echocardiogram or cardiac CT)
- Written informed consent
Show all 14Show fewer
- De novo or restenotic lesion in a native coronary artery; restenotic lesions must have been previously treated with only standard PTCA (treatment must be > 12 months prior to the index procedure)
- Target lesion must be in a major coronary artery (target vessel). The target vessel includes the entire territory of the left anterior descending artery, left circumflex artery or right coronary artery and any major side branch of the artery.
- A maximum of one target lesion and one non-target lesion may be treated per subject. The lesions must be located in separate coronary arteries, with treatment of the non-target lesion occurring first using commercially available therapy (with exception of brachytherapy).
- Lesions may be one solid lesion or a series of multiple, smaller lesions to be treated as one lesion
- Target lesion must be treatable with a single investigational stent; an additional stent may be used when treating a vessel dissection or another similar intra-procedure complication (use of investigational stent preferred)
- Angiographic evidence of ≥ 50% and < 100% stenosis (by operator visual estimate) with a TIMI flow > 1
- Target lesion length of ≤ 31 mm by operator visual estimate
- Target vessel reference diameter of 2.25 mm to 4.0 mm by operator visual estimate
Who cannot join
- Baseline LVEF of < 30%; LVEF may be measured and assessed by standard-of-care echocardiography procedures within 90 days of the index procedure or by a left ventriculogram prior to the index procedure (operator visual assessment)
- PCI in any vessel 30 days prior to the index procedure or planned for within 30 days after the index procedure
- Stroke or transient ischemic attack within the last 6 months prior to enrollment
- Intolerance to contrast agents that cannot be medically managed and/or intolerance to antiplatelet, anticoagulant or thrombolytic medications
- Refusal of blood transfusions
- Any other medical condition, that in the opinion of the investigator, poses an unacceptable risk for implant of a stent according to the study indications
Show all 36Show fewer
- Pregnant, planning to become pregnant or nursing during the course of the study. Women of child-bearing potential must have a negative blood pregnancy (beta hCG) test. Female subjects who are surgically sterile or post-menopausal are exempt from having a pregnancy test.
- Known allergy to L-605 CoCr alloy (cobalt, chromium, tungsten and nickel) or amorphous silicon carbide
- Life expectancy of less than one year
- Participation in any other clinical investigational device or drug study. Subjects may be concurrently enrolled in a post-market study, as long as the post-market study device, drug or protocol does not interfere with the investigational treatment or protocol of this study.
- Documented diagnosis of an acute MI within 72 hours of the index procedure and an elevation of Troponin or CKMB above the URL (CKMB measurement is not required if CK is normal) at the time of the index procedure (99th percentile of the individual investigative site's normal reference population)
- For subjects with stable angina and elevated Troponin, CKMB <99% URL is required
- ECG changes consistent with an acute MI within 72 hours of the index procedure. ECG changes consistent with an acute MI include:
- > 1 mm ST segment elevation or depression in consecutive leads
- New LBBB
- Development of pathological Q-waves in two contiguous leads of the ECG
- Acute coronary syndrome with baseline Troponin > 99% URL
- INR ≥ 1.6
- Concomitant renal failure with serum creatinine level > 2.5 mg/dL
- Unresolved neutropenia (white blood cell count < 3,000 / SL), thrombocytopenia (platelet count < 100,000 / SL) or thrombocytosis (platelet count > 700,000 / SL)
- Unprotected left main CAD (> 50% diameter stenosis by operator visual estimate)
- Target vessel has been treated with any PCI procedure (e.g. PTCA, stent, cutting balloon, atherectomy, etc.) within 12 months prior to the index procedure
- Target lesion has been treated with a stent, cutting balloon or atherectomy any time prior to the index procedure or has been treated with PTCA within 12 months prior to the index procedure
- Target vessel treated with brachytherapy anytime prior to index procedure
- Planned PCI in the target vessel within 9 months after the index procedure
- Target vessel has a non-target lesion with a > 50% stenosis that requires treatment during the index procedure
- Lesions preventing distal perfusion (TIMI flow 0 and 1) prior to wire crossing
- Target lesion is in the left main coronary artery or within 2 mm of the origin of the left anterior descending artery or left circumflex artery by operator visual estimate
- Target lesion is located within a saphenous vein graft or arterial graft
- Target lesion involves a bifurcation - lesion is located in a major coronary artery and involves a side branch with a diameter > 2 mm (by operator visual estimate)
- Presence of a complication following pre-dilatation of target lesion
- Presence of a complication following treatment of a non-target lesion (if applicable)
- Presence of a target vessel/lesion that has excessive tortuousity/angulation or is severely calcified preventing complete inflation of an angioplasty balloon
- Angiographic evidence of thrombus within the target lesion
- Target lesion is located within an aneurysm or associated with an aneurysm in the vessel segment either proximal or distal to the target lesion
- Use of cutting balloons, atherectomy or ablative devices immediately prior to investigational stent placement
Trial locations and contacts
3 sites in 2 countries.
3 sites in 2 countries
Switzerland2 sites
University Hospital of Basel
Basel, 4031
Kantonsspital St. Gallen
Sankt Gallen, 9007
About this study
Official title: The Treatment of Coronary Artery Lesions Using the PRO-Kinetic Energy Cobalt-Chromium, Bare-Metal Stent (BIOHELIX-II)
The purpose of this study is to the assess the clinical performance of the BIOTRONIK PRO-Kinetic Energy stent in subjects with atherosclerotic disease of native coronary arteries.
- Conditions
- Coronary Artery Disease
- Being tested
- PRO-Kinetic Energy Stent
- Medical subject headings
- Coronary Artery Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
PRO-Kinetic Energy StentDevice
Bare-metal stent
| Study group | Role | What they receive |
|---|---|---|
| PRO-Kinetic Energy Stent | Experimental | PRO-Kinetic Energy Stent Receives: Device: PRO-Kinetic Energy Stent |
What is being measured
The primary outcome is the main question the study is designed to answer.
In-stent late lumen loss
Measured: 9-months post procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted15 Mar 2013 (estimated)
- Study startMar 2013
- Primary completionOct 2014
- Study completionOct 2014
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 43 participants (actual)
Sponsor and investigators
- Lead sponsor
- Biotronik AG
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Christoph Kaiser, Prof, Principal investigator, University Hospital of Basel
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01811927
- Sponsor's protocol ID
- C1210
- Acronym
- BIOHELIX-II
- Status last verified
- Mar 2015
- First submitted
- 13 Mar 2013
- Last updated
- 24 Mar 2015
- Results posted
- No
- Data monitoring committee
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 24 Mar 2015. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- The Treatment of Coronary Artery Lesions Using the PRO-Kinetic Energy Cobalt-Chromium, Bare-Metal Stent (BIOHELIX-II)
- ClinicalTrials.gov ID
- NCT01811927
- Acronym / sponsor ID
- BIOHELIX-II / C1210
- Conditions
- Coronary Artery Disease
- Study type
- Interventional
- Recruitment status
- Terminated
- Enrolment
- 43 participants (actual)
- Lead sponsor
- Biotronik AGIndustry (pharma, biotech, devices)
- Study start
- Mar 2013
- Primary completion
- Oct 2014 (actual)
- Study completion
- Oct 2014 (actual)
- First posted
- 15 Mar 2013 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to the assess the clinical performance of the BIOTRONIK PRO-Kinetic Energy stent in subjects with atherosclerotic disease of native coronary arteries.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| PRO-Kinetic Energy Stent | Experimental | Device: PRO-Kinetic Energy StentPRO-Kinetic Energy Stent |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (14 listed)
- Age > or = 18 years
- Willingness to comply with study follow-up requirements
- Candidate for a PCI procedure
- Candidate for coronary artery bypass graft surgery
- Documented evidence of stable or unstable angina pectoris or positive functional ischemia study (e.g. exercise treadmill test, thallium stress test, SPECT, stress echocardiogram or cardiac CT)
Key exclusion criteria (36 listed)
- Baseline LVEF of < 30%; LVEF may be measured and assessed by standard-of-care echocardiography procedures within 90 days of the index procedure or by a left ventriculogram prior to the index procedure (operator visual assessment)
- PCI in any vessel 30 days prior to the index procedure or planned for within 30 days after the index procedure
- Stroke or transient ischemic attack within the last 6 months prior to enrollment
- Intolerance to contrast agents that cannot be medically managed and/or intolerance to antiplatelet, anticoagulant or thrombolytic medications
- Refusal of blood transfusions
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| PRO-Kinetic Energy StentBare-metal stent | Device | PRO-Kinetic Energy Stent |
Primary outcome
In-stent late lumen loss
Time frame: 9-months post procedure
Results and safety
The study was stopped early. Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 24 Mar 2015.
Related trials for Coronary Artery Disease
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
Not yet recruitingPhase 4
Roxadustat and Myocardial Injury After Off-Pump Coronary Artery Bypass Surgery
Coronary Artery Disease, Coronary Artery Bypass Grafting
RecruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
Active, not recruiting
The OCTOBER Trial - European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction (OCTOBER)
Ischaemic Heart Disease, Ischemic Heart Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Christoph Kaiser, Prof principal investigator
University Hospital of Basel
3 sites in 2 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing PRO-Kinetic Energy Stent in people with Coronary Artery Disease, run by Biotronik AG at 3 sites in 2 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 14 inclusion and 36 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: stopped early, as of the sponsor's last update on 24 Mar 2015. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 3 sites in Switzerland, Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was stopped early. Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
In-stent late lumen loss (time frame: 9-months post procedure). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Mar 2015.