AzTrials
AzTrials

Aortic Aneurysm, AbdominalAAA 2D/3D IINCT01824654

Enhanced Guidance for Endovascular Repair of Abdominal Aortic Aneurysm

A study testing Validation of the new rigid registration software and Validation of the new elastic registration software in people with Aortic Aneurysm, Abdominal, run by Centre hospitalier de l'Université de Montréal (CHUM) at 2 sites in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

An increasing incidence of abdominal aortic aneurysms (AAA) is observed in our ageing population. Since it is less invasive, endovascular repair (EVAR) by stent-graft (SG) insertion is frequently indicated in patients with intermediate and high-operative risk. Read more about this study

Who is it for?
Any age
Conditions the study is for
Aortic Aneurysm, Abdominal
What is being tested?
Validation of the new rigid registration software and Validation of the new elastic registration software
Could I receive a placebo?
No, everyone receives an active treatment
How many people
25 participants
Where
2 sitesCanada
Study dates
Apr 2013to Jun 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Patients with a clinical indication for EVAR/FEVAR of AAA and meeting anatomic inclusion criteria on preoperative enhanced CT-scan compatible with an endovascular repair.
  • Willing and capable of providing informed consent

Who cannot join

  • Contraindication to endovascular repair
  • Creatinine clearance < 30ml/min
  • History of severe allergy to iodinated contrast (anaphylaxis, bronchospasm)
  • Absence of recent previous thin-slice enhanced CT-scanner examination (stent planning based on MRI examination or non-enhanced CT examination).

Trial locations and contacts

2 sites in 1 country.

Canada2 sites
  • Queen Elizabeth II Health Science Centre

    Halifax, Nova Scotia, B3H 2Y9

  • Centre Hospitalier de l'université de Montréal

    Montreal, Quebec, H2L 4M1

Other trials in Canada

About this study

Official title: Endovascular Repair of Abdominal Aortic Aneurysm: Enhanced Guidance by Elastic Registration Between CT-Scanner and Fluoroscopy

An increasing incidence of abdominal aortic aneurysms (AAA) is observed in our ageing population. Since it is less invasive, endovascular repair (EVAR) by stent-graft (SG) insertion is frequently indicated in patients with intermediate and high-operative risk. Patient selection and stent planning for EVAR is done on CT-scans based on specific anatomic criteria. SG are inserted in the catheterization laboratory under digital substraction angiography (DSA) and fluoroscopic guidance. With this technology, no soft-tissue differentiation is available during the intervention and important information are lacking such as thrombus and aneurysm extension close to proximal and distal landing zones. Our team has recently patented a software allowing the extraction of the AAA (lumen and thrombus) from pre-operative CT-scanner. In collaboration with Siemens medical, the investigators have integrated this technology to the Siemens workstation in the catheterization laboratory. The investigators can now import the aortic lumen and thrombus meshes segmented from pre-operative CT-scans and perform a rigid registration with fluoroscopy and DSA data to enhance visualization of soft tissue during EVAR.

Our preliminary results are encouraging in terms of feasibility and visualization. However, the delivery device of the SG and the guidewire used during the intervention are stiff and induce a deformation of aortic lumen and thrombus. This deformation impairs the accuracy of rigid registration. The investigators propose to improve registration accuracy by implementing an elastic deformation of aortic lumen and wall based on the segmentation of endovascular devices (delivery device, guidewires and catheters) inserted during the procedure and by biomechanical modeling.

Read the detailed description

This project has 3 objectives: 1. To implement and validate a new optimized workflow enabling rigid registration between AAA meshes extracted from preoperative CT-scan with fluoroscopic images. 2. To develop an elastic registration of the AAA meshes based on 2D or 3D modeling of the endovascular device. 3. To validate the accuracy of elastic registration and compare it with the rigid registration.

Experimental protocol: These 3 objectives will be completed in three experimental phases:

  1. Improvement and implementation of the current rigid registration software. In this phase, several new features such as an improved correction system by automatic capture of DSA, an automated 3D/3D rigid registration, recognition of the origin of internal iliac arteries will be implemented. This new beta version will be tested in 20 patients at CHUM Research center and Dalhousie University-QEII Health Sciences Centre.
  2. Implementation of an elastic registration based on endovascular device segmentation and center line corrections. The luminal path of the segmented lumen on preoperative CT-scan will be aligned with the path of the endovascular devices, then an elastic deformation of the aortic lumen and thrombus meshes generated from CT-scanner will be applied and registered to fluoroscopic and DSA images. A workflow allowing a fast recognition and segmentation of endovascular devices from one to three stereotaxic fluoroscopic views will be implemented in the Leonardo workstation and tested off-line on the previous 20 patient database and also in-vitro in realistic phantoms.
  3. Online validation of elastic registration: The best strategy as defined above will be validated clinically on-line. The beta version will be tested in real time in 20 patients requiring SG procedures and compared to the prior cohort having EVAR/FEVAR procedures with rigid registration. The accuracy of rigid and elastic registrations will be compared in the two experimental groups.
Being tested
Validation of the new rigid registration software, Validation of the new elastic registration software
Keywords
Aortic Aneurysm, Abdominal, Imaging, Three-Dimensional, Tomography Scanners, X-Ray Computed, Angiography, Digital Subtraction, Endovascular Procedures, Radiography, Interventional
Medical subject headings
Aortic Aneurysm, Abdominal

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Validation of the new rigid registration softwareOther

    Several new features of this beta software such as an improved correction system by automatic capture of DSA, an automated 3D/3D rigid registration, recognition of the origin of internal iliac arteries will be implemented. This new beta version will be tested in 20 cases of EVAR/FEVAR at CHUM Research center and Dalhousie University-QEII Health Sciences Centre.

  • Validation of the new elastic registration softwareOther

    This software integrating deformation of vasculature induced by insertion of endovascular devices will be tested in real time in 20 patients requiring SG procedures at CHUM Research center and Dalhousie University-QEII Health Sciences Centre and compared to the prior cohort having EVAR/FEVAR procedures with rigid registration.

Study groups in NCT01824654
Study groupRoleWhat they receive
Rigid and Elastic registration softwaresExperimentalNot described
Receives: Other: Validation of the new rigid registration software; Other: Validation of the new elastic registration software

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Clinical validation of the new rigid registration software

    The measure of the mean 2D error in the z axis (cranio-caudal direction) of the renal arteries marker positions on the first DSA acquisition performed after insertion of the main body delivery device (before correction). It will be measured after exportation of the video on the Leonardo screen overlaying DSA and rigid registration of AAA meshes and renal markers.

    Measured: Day 0: On the first DSA acquisition performed after insertion of the main body device (before correction)

  2. Clinical validation of the new elastic registration software

    The measure of the mean 2D error of renal artery marker position (z direction) on the first DSA acquisition performed after insertion of the main body delivery device as describe in the clinical validation of the new rigid registration software.

    Measured: Day 0: On the first DSA acquisition performed after insertion of the main body delivery device (before correction)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Apr 2013 (estimated)
  2. Study startApr 2013
  3. Primary completionJun 2017
  4. Study completionJun 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
25 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01824654
Sponsor's protocol ID
CE12.333
Acronym
AAA 2D/3D II
Status last verified
Sep 2016
First submitted
2 Apr 2013
Last updated
20 Jul 2018
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Validation of the new rigid registration software and Validation of the new elastic registration software in people with Aortic Aneurysm, Abdominal, run by Centre hospitalier de l'Université de Montréal (CHUM) at 2 sites in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 20 Jul 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Clinical validation of the new rigid registration software (time frame: Day 0: On the first DSA acquisition performed after insertion of the main body device (before correction)). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Jul 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in